Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 221
Filtrar
1.
Front Surg ; 11: 1333670, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38586241

RESUMO

Introduction: Bicortical screw fixation, which penetrates and fixes the near and far cortex of bone, has been conventionally used to achieve compressive fixation for fracture using screws. Open reduction and internal fixation using the locking plate are widely used for treating proximal humerus fractures. However, minimal contact between the bone and the locking plate can lead to an insufficient reduction. Theoretically, a dual-lead locking screw with different leads for the screw head and body could enhance the reduction and fixation stability of fragments in proximal humeral fractures without bicortical fixation, and achieve additional compression at the bone-plate-screw interface. This study assessed the insertion mechanics of the lead ratio of the dual-lead locking screw and its effect on the fixation stability of the proximal humerus fracture. Methods: A Multi-Fix® locking plating system composed of ∅ 3.5 mm locking screws and a locking plate was used to make a locked plating for Sawbone bone blocks and fourth-generation composite humeri. Two different types of Sawbone bone blocks were used to simulate the osteoporotic (10 PCF) and normal cancellous (20 PCF) bones. The lead of the screw head thread (Lhead) was 0.8 mm, and that of the screw body (Lbody) was 0.8, 1.25, 1.6, 2.0, and 2.4 mm, whose lead ratios (Rlead=Lbody/Lhead) were 1.0, 1.56, 2.0, 2.5, and 3.0, respectively. Results: The dual-lead locking screw elevated the compression between the locking plate and the bone. The elevation in the compression due to the dual-lead thread became weaker for the cancellous bone when the lead of the screw body was more than twice that of the screw head. The plate/humerus compression with strong bone quality withstood higher dual-lead-driven compression. Discussion: A dual-lead locking screw of Lbody=1.25mm (Rlead=1.56) is recommended for maximum rotational stability for the locked humerus plating. The screws with over Lbody=1.6mm (Rlead=2) have no advantage in terms of the failure torque and maximum torsional deformation. Any locking dual-lead screw with a body thread lead of <1.6 mm (Rlead=2) can be used without the risk of bone crush when surgeons require additional compression to the locked cancellous bone plating.

2.
Nat Rev Dis Primers ; 10(1): 8, 2024 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-38332156

RESUMO

Rotator cuff tears are the most common upper extremity condition seen by primary care and orthopaedic surgeons, with a spectrum ranging from tendinopathy to full-thickness tears with arthritic change. Some tears are traumatic, but most rotator cuff problems are degenerative. Not all tears are symptomatic and not all progress, and many patients in whom tears become more extensive do not experience symptom worsening. Hence, a standard algorithm for managing patients is challenging. The pathophysiology of rotator cuff tears is complex and encompasses an interplay between the tendon, bone and muscle. Rotator cuff tears begin as degenerative changes within the tendon, with matrix disorganization and inflammatory changes. Subsequently, tears progress to partial-thickness and then full-thickness tears. Muscle quality, as evidenced by the overall size of the muscle and intramuscular fatty infiltration, also influences symptoms, tear progression and the outcomes of surgery. Treatment depends primarily on symptoms, with non-operative management sufficient for most patients with rotator cuff problems. Modern arthroscopic repair techniques have improved recovery, but outcomes are still limited by a lack of understanding of how to improve tendon to bone healing in many patients.


Assuntos
Lesões do Manguito Rotador , Humanos , Lesões do Manguito Rotador/cirurgia , Artroscopia/métodos , Manguito Rotador/cirurgia , Resultado do Tratamento
3.
Artigo em Inglês | MEDLINE | ID: mdl-38237721

RESUMO

BACKGROUND: Spontaneous resolution of a spinoglenoid notch ganglion cyst (SGC) without surgical treatment has been rarely reported; however, we have encountered this phenomenon occasionally. Therefore, we aimed to describe a case series of consecutive patients with SGC in whom it spontaneously resolved without surgical treatment. METHODS: We retrospectively reviewed 12 patients with magnetic resonance imaging (MRI)-confirmed SGC in whom it resolved without surgical treatment between January 2011 and March 2023. We included patients without abnormally increased signal intensity or muscle atrophy due to denervation from suprascapular neuropathy on MRI. Resolution of the SGC was confirmed via MRI or ultrasound at the follow-up visit, and suprascapular neuropathy was assessed using electromyography and nerve conduction studies when needed. For functional assessments, the visual analog scale for pain and active range of motion of the shoulder were used to compare pre and postresolution follow-ups. RESULTS: Eleven men and 1 woman with a median age of 54.0 years (interquartile range [IQR] 37.0-65.3) were included in this study. The SGCs resolved spontaneously at a median of 13.2 months with an IQR of 8.2-23.0 after initial evaluation using MRI. The SGCs were multiloculated cysts with superior labrum anterior and posterior II-IX lesions, with a median diameter of 2.5 cm (IQR 2.0-2.8). The median visual analog scale for pain (pre-resolution 5.0 [IQR 4.0-7.0] vs postresolution 1.0 [IQR 0.0-1.0], P = .002) and internal rotation at the back (preresolution 8.0 [IQR 7.0-10.3] vs postresolution 7.5 [IQR 7.0-8.0], P = .034) were significantly improved after the resolution. CONCLUSIONS: Surgical treatment may not be necessary in all cases of SGC. Nonsurgical treatment may be a viable option in the absence of suprascapular nerve involvement or superior labrum anterior and posterior-related physical findings.

4.
Arthroscopy ; 40(4): 1093-1104.e2, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38000485

RESUMO

PURPOSE: To investigate the effect of recombinant human parathyroid hormone (rhPTH) biocomposite on bone-to-tendon interface (BTI) healing for surgical repair of a chronic rotator cuff tear (RCT) model of rabbit, focusing on genetic, histologic, biomechanical and micro-computed tomography (CT) evaluations. METHODS: Sixty-four rabbits were equally assigned to the 4 groups: saline injection (group A), nanofiber sheet alone (group B), rhPTH-soaked nanofiber sheet (nanofiber sheet was soaked with rhPTH, group C), and rhPTH biocomposite (rhPTH permeated the nanofiber sheet by coaxial electrospinning, group D). The release kinetics of rhPTH (groups C and D) was examined for 6 weeks in vitro. Nanofiber scaffolds were implanted on the surface of the repair site 6 weeks after the induction of chronic RCT. Genetic and histologic analyses were conducted 4 weeks after surgery. Furthermore, genetic, histologic, biomechanical, micro-CT, and serologic analyses were performed 12 weeks after surgery. RESULTS: In vivo, group D showed the highest collagen type I alpha 1 (COL1A1), collagen type III alpha 1 (COL3A1), and bone morphogenetic protein 2 (BMP-2) messenger RNA (mRNA) expression levels (all P < .001) 4 weeks after surgery; however, there were no differences between groups at 12 weeks postsurgery. After 12 weeks postsurgery, group D showed better collagen fiber continuity and orientation, denser collagen fibers, more mature bone-to-tendon junction, and greater fibrocartilage layer formation compared with the other groups (all P < .05). Furthermore, group D showed the highest load-to-failure rate (28.9 ± 2.0 N/kg for group A, 30.1 ± 3.3 N/kg for group B, 39.7 ± 2.7 N/kg for group C, and 48.2 ± 4.5 N/kg for group D, P < .001) and micro-CT outcomes, including bone and tissue mineral density, and bone volume/total volume rate (all P < .001) at 12 weeks postsurgery. CONCLUSIONS: In comparison to rhPTH-soaked nanofiber sheet and the other control groups, rhPTH biocomposite effectively accelerated BTI healing by enhancing the mRNA expression levels of COL1A1, COL3A1, and BMP-2 at an early stage and achieving tenogenesis, chondrogenesis, and osteogenesis at 12 weeks after surgical repair of a chronic RCT model of rabbit. CLINICAL RELEVANCE: The present study might be a transitional study to demonstrate the efficacy of rhPTH biocomposites on BTI healing for surgical repair of chronic RCTs as an adaptable polymer biomaterial in humans.


Assuntos
Lesões do Manguito Rotador , Animais , Humanos , Coelhos , Lesões do Manguito Rotador/cirurgia , Lesões do Manguito Rotador/patologia , Osteogênese , Condrogênese , Cicatrização , Modelos Animais de Doenças , Tendões/cirurgia , Hormônio Paratireóideo/farmacologia , Hormônio Paratireóideo/uso terapêutico , Colágeno/farmacologia , RNA Mensageiro , Fenômenos Biomecânicos
5.
Front Bioeng Biotechnol ; 11: 1229646, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38130822

RESUMO

Massive irreparable rotator cuff tears (RCTs) affect the clinical outcomes of reverse shoulder arthroplasty (RSA). However, the effects of subscapularis repair on the outcomes of RSA, based on the degree of posterior-superior RCTs, are unclear. This study aimed to examine the effect of subscapularis repair on three-dimensional joint contact forces (JCFs) based on the degree of posterior-superior RCT severity in RSA. Ten human in vivo experimental data were used as input to the musculoskeletal model. A six-degrees-of-freedom (DOF) anatomical shoulder model was developed and validated against three-dimensional JCFs. The 6-DOF musculoskeletal shoulder model of RSA was then developed by importing the reverse shoulder implant into the validated anatomical shoulder model. Based on the various types of posterior-superior RCT severity, inverse dynamic simulations of subscapularis-torn and subscapularis-repaired models of RSA were performed: from isolated supraspinatus tears to partial or massive tears of the infraspinatus and teres minor. The intact rotator cuff model of RSA was also simulated for comparison with the different types of models. Our results showed that the more posterior-superior RCTs progressed in RSA, the more superior JCFs were observed at 90°, 105°, and 120° abduction in the subscapularis-torn model. However, subscapularis repair decreased the superior JCF at those angles sufficiently. In addition, the teres minor muscle-tendon force increased as infraspinatus bundle tears progressed in both the subscapularis-torn and -repaired models, in order to compensate for the reduced force during abduction. However, the teres minor muscle-tendon force was not as high as that of the infraspinatus muscle-tendon, which could result in muscle force imbalance between repaired subscapularis and teres minor. Therefore, our results suggest that repairing the subscapularis and the repairable infraspinatus during RSA can improve glenohumeral joint stability in the superior-inferior direction by restoring muscle force balance between the anterior cuff (i.e., subscapularis) and posterior cuff (i.e., infraspinatus and teres minor). The findings of this study can help clinician decide whether to repair the rotator cuff during RSA to enhance joint stability.

6.
BMC Musculoskelet Disord ; 24(1): 878, 2023 Nov 11.
Artigo em Inglês | MEDLINE | ID: mdl-37951880

RESUMO

BACKGROUNDS: The humeral head is the second most common site of osteonecrosis, after the femoral head. However, compared to osteonecrosis of the femoral head (ONFH), epidemiological information on osteonecrosis of the humeral head (ONHH) is scarce. We hypothesised that different biomechanical properties of the shoulder from the hip joint might present different epidemiological characteristics of ONHH from those of the ONFH. To evaluate epidemiological differences, we compared trends in the surgical treatment of ONHH and ONFH using the nationwide medical claims database of the Republic of Korea (ROK). METHODS: We analysed epidemiological data from the Health Insurance Review and Assessment (HIRA) database of the ROK between 2008 and 2018. HIRA database contains almost all medical information in an anonymised form, including demographics, diagnoses, and types of surgical procedures, generated through healthcare practices in ROK. The annual incidence rates of ONHH and ONFH were calculated based on the total number of the general population. Demographics, annual incidence, and the proportion of post-traumatic osteonecrosis and surgical procedures were compared according to the anatomical site and the affected year. RESULTS: The total number of patients treated for ONHH and ONFH during the study period was 1,028 and 66,260, respectively. Although the incidence of ONHH increased, it is a relatively rare disease compared to ONFH. ONHH occurred more frequently in females, while ONFH occurred predominantly in male patients (p < 0.001). Surgical treatment for ONHH was most frequently performed in older patients (63.7%), whereas middle-aged patients had the largest proportion of ONFH (48.9%, p < 0.001). The proportion of post-traumatic osteonecrosis was significantly higher in the ONHH (5.1%) than in the ONFH (1.9%, p < 0.001). Arthroplasty was performed more frequently in the ONHH (96.0%) than in the ONFH (92.9%, p < 0.001). CONCLUSION: Despite the anatomical similarities between the hip and shoulder joints, the different biomechanical properties, such as weight-bearing functions, might cause epidemiological differences between ONHH and ONFH.


Assuntos
Necrose da Cabeça do Fêmur , Cabeça do Fêmur , Pessoa de Meia-Idade , Feminino , Humanos , Masculino , Idoso , Articulação do Quadril , Necrose da Cabeça do Fêmur/cirurgia , Cabeça do Úmero/cirurgia , República da Coreia/epidemiologia
7.
Clin Orthop Surg ; 15(5): 826-833, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37811506

RESUMO

Background: The efficacy of far-infrared radiation (FIR) after rotator cuff repair has not been demonstrated yet. The aim of this study was to evaluate the effects of postoperatively applied FIR with regard to early pain, range of motion (ROM), and tendon-to-bone healing after arthroscopic rotator cuff repair. Methods: A total of 64 consecutive patients who underwent arthroscopic rotator cuff repair with small- to medium-sized tears were enrolled in this prospective comparative study and randomly divided into an FIR group (n = 31) and a control group (n = 33). In the FIR group, FIR using a radiator device (Aladdin-H) was applied for 30 minutes per session twice daily from the first postoperative day. This application lasted for 10 weeks during the postoperative period. Clinical outcomes were assessed using a visual analog scale for pain (pVAS) at 5 weeks and ROM at 3 and 6 months postoperatively. Functional scores were evaluated at 6 months postoperatively. Healing of the repaired rotator cuff was also evaluated using ultrasonography at 3 months and magnetic resonance imaging at 6 months postoperatively. Results: In both groups, clinical and functional outcomes were improved up to 6 months compared with preoperative values. At 5 weeks and 3 months postoperatively, the average pVAS was significantly lower in the FIR group than in the control group (1.7 ± 1.0 vs. 2.8 ± 1.4; p = 0.002 at 5 weeks, 2.4 ± 1.3 vs. 3.2 ± 1.8; p = 0.041 at 3 months). However, there was no significant difference in ROM, functional score, or healing rate between two groups at each follow-up time point. Conclusions: The application of FIR after arthroscopic rotator cuff repair could be a safe and effective procedure to decrease postoperative pain, especially in the early postoperative period. This effective application of FIR can be considered to facilitate painless rehabilitation in the postoperative period after arthroscopic rotator cuff repair.


Assuntos
Lesões do Manguito Rotador , Manguito Rotador , Humanos , Artroscopia/métodos , Imageamento por Ressonância Magnética , Dor Pós-Operatória , Estudos Prospectivos , Amplitude de Movimento Articular , Manguito Rotador/diagnóstico por imagem , Manguito Rotador/cirurgia , Lesões do Manguito Rotador/cirurgia , Resultado do Tratamento
8.
JSES Int ; 7(5): 756-762, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37719831

RESUMO

Background: Common magnetic resonance imaging (MRI) findings in adhesive capsulitis are not often evident in rotator cuff tear concomitant with shoulder stiffness. This study aimed to determine the most predictive MRI finding of rotator cuff tear with shoulder stiffness to differentiate from that without stiffness. Materials and methods: The data of patients who underwent arthroscopic rotator cuff repair between January 2014 and October 2019 were retrospectively reviewed. Stiffness was defined as forward flexion <120°, external rotation at side <30°, and internal rotation at back 

9.
Am J Sports Med ; 51(12): 3243-3250, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37681499

RESUMO

BACKGROUND: The incidence of rotator cuff tears is rapidly increasing, and operative techniques for rotator cuff repair have been developed. However, the rates of postoperative retear remain high. PURPOSE/HYPOTHESIS: The purpose was to determine the effects of human dermal fibroblasts (HDFs) with hyaluronic acid (HA) on tendon-to-bone healing in a rabbit model of chronic rotator cuff tear injury. It was hypothesized that HA would enhance HDF proliferation and that a combination of HA and HDFs would produce a synergistic effect on the healing of repaired rotator cuff tendons of rabbits. STUDY DESIGN: Controlled laboratory study. METHODS: For in vitro study, HDFs were plated on a 24-well plate. After 1 day, 2 wells were designated as the test group and treated with 0.75% HA in phenol red-free Dulbecco's modified Eagle medium (DMEM). An other 2 wells served as control groups and were treated with the same volume of phenol red-free DMEM without HA. Each group was duplicated, resulting in a total of 4 wells, with 2 wells in each group for replication purposes. The cells were incubated for 24 hours, followed by 72-hour cultivation. Absorbance ratios at 96 and 24 hours were compared to evaluate cell proliferation. For the in vivo study, a total of 24 rabbits were randomly allocated to groups A, B, and C (n = 8 each). Supraspinatus tendons were detached bilaterally and left for 6 weeks to establish a chronic rotator tear model. Torn tendons were subsequently repaired using the following injections: group A, 0.5 × 106 HDFs with HA; group B, HA only; and group C, saline only. At 12 weeks after repair, biomechanical tests and histological evaluation were performed. RESULTS: In vitro study showed that HDF proliferation significantly increased with HA (HDFs with HA vs HDFs without HA; 3.96 ± 0.09 vs 2.53 ± 0.15; P < .01). In vivo, group A showed significantly higher load-to-failure values than the other groups (53.8 ± 6.9 N/kg for group A, 30.6 ± 6.4 N/kg for group B, and 24.3 ± 7.6 N/kg for group C; P < .001). Histological evaluation confirmed that group A showed higher collagen fiber density and better collagen fiber continuity, tendon-to-bone interface maturation, and nuclear shape than the other groups (all P < .05). CONCLUSION: This controlled laboratory study verified the potential of the combination of HDFs and HA in enhancing healing in a chronic rotator cuff tear rabbit model. CLINICAL RELEVANCE: A potential synergistic effect on rotator cuff tendon healing may be expected from a combination of HDFs and HA.


Assuntos
Lesões do Manguito Rotador , Animais , Humanos , Coelhos , Lesões do Manguito Rotador/cirurgia , Lesões do Manguito Rotador/patologia , Ácido Hialurônico/farmacologia , Ácido Hialurônico/uso terapêutico , Cicatrização , Modelos Animais de Doenças , Tendões/cirurgia , Ruptura/cirurgia , Fibroblastos , Colágeno/farmacologia , Fenóis/farmacologia , Fenômenos Biomecânicos
10.
Clin Shoulder Elb ; 26(3): 276-286, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37559521

RESUMO

BACKGROUND: The transosseous anchorless repair (ToR) technique was recently introduced to avoid suture anchor-related problems. While favorable outcomes of the ToR technique have been reported, no previous studies on peri-implant cyst formation with the ToR technique exist. Therefore, this study compared the clinical outcomes and prevalence of peri-implant cyst formation between the ToR technique and the conventional transosseous equivalent technique using suture anchors (SA). METHODS: Cases with arthroscopic rotator cuff repair (ARCR) between 2016 and 2018 treated with the double-row suture bridge technique were retrospectively reviewed. Patients were divided into ToR and SA groups. To compare clinical outcomes, 19 ToR and 57 SA cases without intraoperative implant failure were selected using propensity score matching (PSM). While intraoperative implant failure rate was analyzed before PSM, retear rate, peri-implant cyst formation rate, and functional outcomes were compared after PSM. RESULTS: The intraoperative implant failure rate (ToR, 8% vs. SA, 15.3%) and retear rate (ToR, 5.3% vs. SA, 19.3%) did not differ between the two groups (all P>0.05). However, peri-implant cysts were not observed in the ToR group, while they were observed in 16.7% of the SA group (P=0.008). Postoperative functional outcomes were not significantly different between the two groups (all P>0.05). CONCLUSIONS: The ToR technique produced comparable clinical outcomes to conventional techniques. Considering the prospect of potential additional surgeries, the absence of peri-implant cyst formation might be an advantage of ToR. Furthermore, ToR might reduce the medical costs related to suture anchors and, thereby, could be a useful option for ARCR. Level of evidence: III.

11.
BMC Surg ; 23(1): 193, 2023 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-37407984

RESUMO

BACKGROUND: Anatomical total shoulder arthroplasty (aTSA) has been used to manage degenerative diseases such as primary osteoarthritis. An increase in the use of this procedure has led to several developments in humeral and glenoid components to improve patient outcomes. This study aimed to compare clinical and radiological outcomes of the newly-introduced convertible metal-backed glenoid components with cemented polyethylene glenoid components in aTSA, and to determine whether the new component would be comparable to a conventional one for reducing the burden of future revision or conversion surgeries. METHODS: Medical records of fifty patients who underwent aTSA with at least two years of follow-up were retrospectively reviewed. Eighteen patients received convertible metal-backed glenoid components with vitamin E1-coated liner (MB group), while thirty-two patients received conventional cemented polyethylene glenoid components (PE group). Pre- and postoperative clinical and radiological outcomes (acromion-greater tuberosity angle [AGA] and humeral lateral offset [LO]) at final follow-up were assessed. Radiolucent lines (RLLs) and loosening around the humeral and glenoid components were also evaluated. RESULTS: Clinical outcomes improved after surgery in both groups (all p < 0.001). The arc of rotation measured by AGA improved postoperatively in both groups (all p < 0.001), and AGA and LO were not different according to the type of glenoid components (all p > 0.05). Overall complication rates including RLLs of PE and MB groups were 43.8% (14/32) and 16.7% (3/18), respectively (p = 0.031). Although the PE group had more RLLs than did the MB group (p < 0.05), related symptoms and/or glenoid implant loosening were not observed in both groups. Subscapularis failure occurred in two patients in the PE group and in one in the MB group. CONCLUSION: The convertible metal-backed glenoid implant with vitamin E1-coated liner may be a good alternative for considering the potential for an easier conversion to reverse total shoulder arthroplasty.


Assuntos
Artroplastia do Ombro , Prótese Articular , Osteoartrite , Articulação do Ombro , Humanos , Polietileno , Articulação do Ombro/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Osteoartrite/cirurgia , Desenho de Prótese , Seguimentos
12.
J Orthop Sci ; 2023 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-37365077

RESUMO

BACKGROUND: Although various treatment options are available for spinoglenoid cyst, including conservative and surgical methods, there is no standard guideline for its surgical decompression. Thus, the purpose of the study was to correlate the size of the spinoglenoid notch ganglion cyst (GC) as revealed by magnetic resonance imaging (MRI) with electrophysiological alterations, muscle power, and pain severity, and to estimate a cut-off value of cyst size to perform a decompression. METHODS: Between January 2010 and January 2018, the patients with a GC at the spinoglenoid notch diagnosed on MRI, and who had a minimum follow-up of 2 years after the decompression were included. Maximum cyst diameter as measured on MRI was used for comparison. Electromyography (EMG) and nerve conduction velocity (NCV) studies were performed before the surgery. Peak torque deficit (PTD) percentage compared to opposite shoulder was calculated preoperatively and at 1 year after surgery. Pain severity was estimated using visual analogue scale (VAS) preoperatively. RESULTS: Ten (50%) of 20 patients with GC > 2.2 cm and 1 (5.9%) of 17 patients with GC < 2.2 cm showed EMG/NCV abnormalities (p = 0.019). There was a correlation between the cyst size and the positive EMG/NCV findings (Correlation coefficient (CC) = 0.535, p < 0.001). The preoperative peak torque deficit on the external rotation was correlated with the positive EMG/NCV findings (CC = 0.373, p = 0.021). The PTD was improved significantly at 1 year postoperatively in patients with a GC size >2.2 cm (p = 0.029). The cyst size was not related to the preoperative pain VAS and muscle power. CONCLUSIONS: The spinoglenoid cyst size >2.2 cm, but not pain severity or muscle power, correlates with the positive finding of EMG for compressive suprascapular neuropathy. The GC size >2.2 cm can be a reference to decide the need of decompression surgery. LEVEL OF EVIDENCE: IV, case series.

13.
Am J Sports Med ; 51(9): 2431-2442, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37345646

RESUMO

BACKGROUND: Functional restoration of the bone-to-tendon interface (BTI) after rotator cuff repair is a challenge. Therefore, numerous biocompatible biomaterials for promoting BTI healing have been investigated. PURPOSE: To determine the efficacy of scaffolds with spatiotemporal delivery of growth factors (GFs) to accelerate BTI healing after rotator cuff repair. STUDY DESIGN: Controlled laboratory study. METHODS: An advanced 3-dimensional printing technique was used to fabricate bioactive scaffolds with spatiotemporal delivery of multiple GFs targeting the tendon, fibrocartilage, and bone regions. In total, 50 rabbits were used: 2 nonoperated controls and 48 rabbits with induced chronic rotator cuff tears (RCTs). The animals with RCTs were divided into 3 groups: (A) saline injection, (B) scaffold without GF, and (C) scaffold with GF. To induce chronic models, RCTs were left unrepaired for 6 weeks; then, surgical repairs with or without bioactive scaffolds were performed. For groups B and C, each scaffold was implanted between the bony footprint and the supraspinatus tendon. Four weeks after repair, quantitative real-time polymerase chain reaction and immunofluorescence analyses were performed to evaluate early signs of regenerative healing. Histological, biomechanical, and micro-computed tomography analyses were performed 12 weeks after repair. RESULTS: Group C had the highest mRNA expression of collagen type I alpha 1, collagen type III alpha 1, and aggrecan. Immunofluorescence analysis showed the formation of an aggrecan+/collagen II+ fibrocartilaginous matrix at the BTI when repaired with scaffold with GFs. Histologic analysis revealed greater collagen fiber continuity, denser collagen fibers, and a more mature tendon-to-bone junction in GF-embedded scaffolds than those in the other groups. Group C demonstrated the highest load-to-failure ratio, and modulus mapping showed that the distribution of the micromechanical properties of the BTI repaired with GF-embedded scaffolds was comparable with that of the native BTI. Micro-computed tomography analysis identified the highest bone mineral density and bone volume/total volume ratio in group C. CONCLUSION: Bioactive scaffolds with spatially embedded GFs have significant potential to promote the BTI healing of chronic RCTs in a rabbit model. CLINICAL RELEVANCE: The scaffolds with spatiotemporal delivery of GF may serve as an off-the-shelf biomaterial graft to promote the healing of RCTs.


Assuntos
Lesões do Manguito Rotador , Animais , Coelhos , Lesões do Manguito Rotador/cirurgia , Cicatrização , Agrecanas , Tendões/cirurgia , Colágeno , Materiais Biocompatíveis , Fenômenos Biomecânicos , Modelos Animais de Doenças
14.
NPJ Digit Med ; 6(1): 95, 2023 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-37221303

RESUMO

A digital healthcare system based on augmented reality (AR) has promising uses for postoperative rehabilitation. We compare effectiveness of AR-based and conventional rehabilitation in patients after rotator cuff repair (RCR). This study randomly allocates 115 participants who underwent RCR to digital healthcare rehabilitation group (DR group) and conventional rehabilitation group (CR group). The DR group performs AR-based home exercises using UINCARE Home+, whereas the CR group performs brochure-based home exercises. The primary outcome is a change in the Simple Shoulder Test (SST) score between baseline and 12 weeks postoperatively. The secondary outcomes are the Disabilities of the Arm, Shoulder and Hand (DASH) score; Shoulder Pain And Disability Index (SPADI) score; EuroQoL 5-Dimension 5-Level (EQ5D5L) questionnaire score; pain; range of motion (ROM); muscle strength; and handgrip strength. The outcomes are measured at baseline, and at 6, 12, and 24 weeks postoperatively. The change in SST score between baseline and 12 weeks postoperatively is significantly greater in the DR group than in the CR group (p = 0.025). The SPADI, DASH, and EQ5D5L scores demonstrate group×time interactions (p = 0.001, = 0.04, and = 0.016, respectively). However, no significant differences over time are observed between the groups in terms of pain, ROM, muscle strength, and handgrip strength. The outcomes show significant improvement in both groups (all p < 0.001). No adverse events are reported during the interventions. AR-based rehabilitation shows better improvement in terms of shoulder function after RCR compared to conventional rehabilitation. Therefore, as an alternative to the conventional rehabilitation, the digital healthcare system is effective for postoperative rehabilitation.

15.
J Shoulder Elbow Surg ; 32(8): 1662-1672, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37044302

RESUMO

BACKGROUND: The objective of our study was to quantify the biomechanical effectiveness of lateralization in RTSA with respect to glenoid and humeral component configurations. METHODS: Eight cadaveric shoulders were tested in a custom shoulder testing system. Three parameters, including the glenosphere thickness, humeral tray offset, and insert thickness, were assessed by implanting 8 configurations on each specimen. Humeral position, maximum internal rotation, and maximum external rotation (ER) before impingement were quantified at 0° and 30° glenohumeral abduction. The adduction angle at which the humeral component contacted the inferior scapular neck and the abduction angle where acromial notching occurred were also measured. The simulated active range of motion, including ER and abduction capability, was tested by increasing the load applied to the remaining posterior cuff and middle deltoid, respectively. Stability was evaluated by the forces that induced anterior dislocation at 30° abduction. RESULTS: The thicker glenosphere affected only lateralization, whereas the centric humeral tray and thicker insert significantly affected humeral lateralization and distalization simultaneously. Greater adduction and ER angles were found in more lateralized humerus. A significant positive correlation between humeral lateralization and ER capability was observed; however, lateralization did not significantly improve implant stability in this cadaveric testing system. CONCLUSION: Lateralization is achievable at both the glenoid and humeral sides but has different effects; therefore, lateralized implant options should be selected according to patients' needs. Lateralization is an effective strategy for reducing adduction notching while increasing ER capability. Thicker glenospheres only affected humeral lateralization. The centric humeral tray would be selected for less distalization to avoid overlengthening, whereas an eccentric humeral tray is the most effective for distalization and medialization in reducing abduction notching to the acromion and for patients with pseudoparalysis.


Assuntos
Artroplastia do Ombro , Articulação do Ombro , Humanos , Artroplastia do Ombro/métodos , Articulação do Ombro/cirurgia , Desenho de Prótese , Amplitude de Movimento Articular , Cadáver , Úmero/cirurgia , Fenômenos Biomecânicos
16.
J Shoulder Elbow Surg ; 32(9): 1876-1885, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37024040

RESUMO

BACKGROUND: Scapular notching is a well-known postoperative complication of reverse total shoulder arthroplasty (RTSA). However, subacromial notching (SaN), a subacromial erosion caused by repeated abduction impingement after RTSA, has not been previously reported in a clinical setting. Therefore, this study aimed to assess the risk factors and functional outcomes of SaN after RTSA. METHODS: We retrospectively reviewed the medical records of 125 patients who underwent RTSA with the same design between March 2014 and May 2017 and had at least 2 years of follow-up. SaN was defined as subacromial erosion observed at the final follow-up but not on the X-ray 3 months after surgery. Radiologic parameters representing the patient's native anatomy and degrees of lateralization and/or distalization during surgery were evaluated using preoperative and 3 months postoperative X-rays. The visual analogue scale of pain, active range of motion, and American Shoulder and Elbow Surgeons score were assessed preoperatively and at the final follow-up to evaluate the functional outcomes of SaN. RESULTS: SaN occurred in 12.8% (16/125) of enrolled patients during the study period. Preoperative center of rotation-acromion distance (P = .009) and postoperative humerus lateralization offset, which evaluated the degree of lateralization after RTSA (P = .003), were risk factors for SaN. The preoperative center of rotation-acromion distance and postoperative humerus lateralization cutoff values were 14.0 mm and 19.0 mm, respectively. The visual analogue scale of pain (P = .01) and American Shoulder and Elbow Surgeons score (P = .04) at the final follow-up were significantly worse in patients with SaN. CONCLUSIONS: SaN might adversely affect postoperative clinical outcomes. As SaN correlated with patients' anatomical characteristics and degree of lateralization during RTSA, the implant's degree of lateralization should be adjusted according to the patient's own anatomical characteristics.


Assuntos
Artroplastia do Ombro , Articulação do Ombro , Prótese de Ombro , Humanos , Artroplastia do Ombro/efeitos adversos , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Dor/etiologia , Amplitude de Movimento Articular
17.
Clin Orthop Surg ; 15(2): 281-289, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37008964

RESUMO

Background: Negative effects of extracorporeal shock wave therapy (ESWT) on vulnerable tendon structures have been reported. Meanwhile, tears of the posterior rotator cuff tendon, which is thinner than the anterior, are not common, and the clinical features remain poorly understood. Therefore, we evaluated the relationship between ESWT and posterior rotator cuff tears (RCTs) by investigating the risk factors. Methods: Of 294 patients who underwent rotator cuff repair between October 2020 and March 2021, a posterior RCT more than 1.5 cm from the biceps tendon or an isolated infraspinatus tear was identified in 24 (8.1%, group P). Sixty-two patients (21%) with an anterior RCT within 1.5 cm of the biceps tendon were analyzed as a control group (group A). Preoperative clinical characteristics were assessed to determine the risk factors of posterior RCTs. Results: Calcific deposits were more frequently observed in group P (n = 7, 29.2%) than group A (n = 6, 9.7%, p = 0.024). Further, those in group P were more likely to undergo ESWT (n = 18, 75.0%) than those in group A (n = 15, 24.2%, p < 0.001). Of these, 7 patients experiencing calcific tendinitis from group P (29.2%) and 4 from group A (6.5%, p = 0.005) underwent ESWT for calcification removal. Furthermore, 11 patients experiencing tendinopathy from group P (45.8%), and 11 from group A (17.7%, p = 0.007) underwent ESWT for pain relief. The mean level of fatty infiltration of the supraspinatus was significantly higher in group A than group P (1.8 vs. 1.0, p < 0.001). Conclusions: Since a high prevalence rate of posterior RCTs was related to ESWT, it should be carefully considered when treating calcific tendinitis or pain in patients experiencing tendinopathy.


Assuntos
Tratamento por Ondas de Choque Extracorpóreas , Lesões do Manguito Rotador , Humanos , Lesões do Manguito Rotador/complicações , Lesões do Manguito Rotador/terapia , Tratamento por Ondas de Choque Extracorpóreas/efeitos adversos , Dor de Ombro/etiologia , Fatores de Risco , Tendinopatia , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Idoso
18.
Clin Shoulder Elb ; 26(1): 93-106, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36919511

RESUMO

Reverse total shoulder arthroplasty (RTSA) emerged as a new concept of arthroplasty that does not restore normal anatomy but does restore function. It enables the function of the torn rotator cuff to be performed by the deltoid and shows encouraging clinical outcomes. Since its introduction, various modifications have been designed to improve the outcome of the RTSA. From the original cemented baseplate with peg or keel, a cementless baseplate was designed that could be fixed with central and peripheral screws. In addition, a modular-type glenoid component enabled easier revision options. For the humeral component, the initial design was an inlay type of long stem with cemented fixation. However, loss of bone stock from the cemented stem hindered revision surgery. Therefore, a cementless design was introduced with a firm metaphyseal fixation. Furthermore, to prevent complications such as scapular notching, the concept of lateralization emerged. Lateralization helped to maintain normal shoulder contour and better rotator cuff function for improved external/internal rotation power, but excessive lateralization yielded problems such as subacromial notching. Therefore, for patients with pseudoparalysis or with risk of subacromial notching, a medial eccentric tray option can be used for distalization and reduced lateralization of the center of rotation. In summary, it is important that surgeons understand the characteristics of each implant in the various options for RTSA. Furthermore, through preoperative evaluation of patients, surgeons can choose the implant option that will lead to the best outcomes after RTSA.

19.
Clin Orthop Surg ; 15(1): 118-126, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36779001

RESUMO

Background: Synovial osteochondromatosis (SOC) of the shoulder is a rare condition with unclear characteristics. This study evaluated the clinical features and postoperative functional outcomes of SOC of the shoulder that are distinct from SOC of other joints. Methods: The characteristics of 28 shoulders with SOC that underwent arthroscopy were retrospectively assessed. Ten shoulders (35.7%) had rotator cuff tears (RCTs) and underwent concomitant arthroscopic rotator cuff repair. The mean follow-up period was 83.6 months (range, 24-154 months). Demographic characteristics and loose bodies localized under arthroscopy were compared between cases with and without concomitant RCTs. Radiography, ultrasonography, or magnetic resonance imaging were performed preoperatively and postoperatively. Visual analog scale (VAS) scores for pain and satisfaction were evaluated for all cases, and functional scores were assessed in shoulders with concomitant RCTs. Results: The average age was 36.2 ± 15.6 years among patients without RCTs and 58.3 ± 7.2 years among patients with RCTs. Seven shoulders (7%) had osteoarthritis. Arthroscopy revealed loose bodies in multiple spaces, including the glenohumeral joint, subacromial (SA) space, and biceps tendon sheath. Overall, loose bodies were found in multiple spaces in 12 shoulders (42.9%). Loose bodies were found in the SA space only in 4 shoulders (22.2%) without RCTs and in 7 shoulders (70.0%) with RCTs. VAS for pain decreased significantly from 3.9 ± 2.3 to 1.1 ± 1.3 (p < 0.001). The functional scores increased significantly after arthroscopic management for patients with concurrent RCTs (all p < 0.05). Recurrence of SOC occurred in 3 of the 22 shoulders (13.6%) who underwent postoperative imaging, but no patient had a recurrent RCT. Conclusions: Pain relief and patient satisfaction were achieved via arthroscopic management. Unlike in other joints, loose bodies can occur simultaneously in several spaces in the shoulder, including the glenohumeral joint, SA space, and biceps tendon sheath. Early diagnosis of SOC of the SA space can help prevent osteoarthritis and RCT progression.


Assuntos
Condromatose Sinovial , Osteoartrite , Lesões do Manguito Rotador , Articulação do Ombro , Humanos , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Ombro/cirurgia , Manguito Rotador/cirurgia , Condromatose Sinovial/diagnóstico por imagem , Condromatose Sinovial/cirurgia , Resultado do Tratamento , Lesões do Manguito Rotador/cirurgia , Articulação do Ombro/cirurgia , Artroscopia/métodos , Dor
20.
Am J Sports Med ; 51(3): 723-732, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36745013

RESUMO

BACKGROUND: There is a lack of studies about serum and tissue vitamin D levels of the rotator cuff muscle on muscle power, fatty degeneration, and healing failure after rotator cuff repair (RCR). Furthermore, no studies have evaluated vitamin D receptor proteins in the rotator cuff that show a close association with serum vitamin D levels. PURPOSE: To evaluate the correlations between serum vitamin D and tissue vitamin D as well as perioperative variables of arthroscopic RCR. STUDY DESIGN: Case series; Level of evidence, 4. METHODS: From March 2017 to October 2017, a total of 36 patients who underwent RCR were prospectively enrolled, and supraspinatus muscle tissue was obtained during surgery to analyze tissue vitamin D levels. Serum vitamin D levels were checked preoperatively and at 6 months and 1 year postoperatively. Tissue vitamin D levels were assessed using liquid chromatography, and the vitamin D receptor was measured by western blotting. Isokinetic muscle performance test (IMPT; peak torque and torque deficiency compared with the opposite shoulder) results and fatty degeneration of the rotator cuff using the Goutallier classification were assessed preoperatively and at 1 year after surgery. The American Shoulder and Elbow Surgeons score and Constant score were collected at 2 years after surgery. Healing failure of the repaired rotator cuff was analyzed by magnetic resonance imaging at 1 year after surgery. RESULTS: Overall, only three patients (8.3%) had serum vitamin D sufficiency (>20 ng/mL). Among 36 patients, 26 patients returned for their 1-year follow-up. Lower preoperative serum vitamin D levels resulted in lower serum vitamin D levels at 6 months and 1 year postoperatively (all P < .05). Lower preoperative and 1-year postoperative serum vitamin D levels resulted in more torque deficiency on the IMPT in abduction than higher preoperative and 1-year postoperative serum vitamin D levels (all P < .05). Tissue vitamin D levels had a strong correlation with preoperative serum vitamin D levels (P = .001). Lower tissue vitamin D levels were associated with lower peak torque on the IMPT in abduction (P = .043) and a tendency of lower peak torque on the IMPT in external rotation (P = .077) at 1 year postoperatively. There was no correlation between tissue and serum vitamin D levels and functional outcomes, fatty degeneration, and healing failure after surgery (all P > .05). The vitamin D receptor showed no correlation with any variables (all P > .05). CONCLUSION: Lower preoperative serum vitamin D levels had a strong correlation with lower tissue vitamin D levels and lower serum vitamin D levels at 1 year after surgery. Furthermore, the patients with lower serum vitamin D levels showed more weakness of muscle power perioperatively. The results of this study emphasized the association between vitamin D levels and rotator cuff muscle power.


Assuntos
Lesões do Manguito Rotador , Manguito Rotador , Humanos , Manguito Rotador/patologia , Vitamina D , Receptores de Calcitriol , Resultado do Tratamento , Artroscopia/métodos , Imageamento por Ressonância Magnética , Amplitude de Movimento Articular , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA