Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Transfusion ; 41(9): 1107-13, 2001 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-11552066

RESUMO

BACKGROUND: Studies were conducted using samples from early and late-stage HBV-infected persons to determine the pool size at which PCR had better sensitivity than a sensitive HBsAg chemoluminescence immunoassay (CLIA-HBsAg). STUDY DESIGN AND METHODS: HBV seroconversion panels were tested for HBsAg by CLIA and for HBV DNA by nested PCR (95% hit rate: 100 copies/mL); PCR was carried out at various dilutions. HBV serologically positive samples that were detected from the simultaneous screening of 540,161 routine whole-blood donations using CLIA-HBsAg and agglutination assays were also characterized for additional markers of HBV infection. RESULTS: In 9 of 10 HBV seroconversion panels, PCR had better sensitivity than CLIA-HBsAg at dilutions of 1-in-25 or lower. Of 65 CLIA-only confirmed-positive donor samples (agglutination assay-negative), 8 represented early infection, 2 of which were PCR positive at a 1-in-50 dilution but negative at a 1-in-100 dilution. Only 2 of 47 samples from probable late-stage HBV infection that were positive on CLIA only were PCR positive with 0.1-mL sample volume and the S-region primer; the remaining 45 samples required a 1.0-mL sample input and C-region primer for increased PCR positivity. The remaining 10 CLIA-only confirmed-positive donor samples were from HBV vaccine recipients. None of the 12 CLIA- and HBsAg-negative donor samples that were strongly anti-HBc reactive could be detected by PCR at any dilution; all 12 were PCR positive when undiluted, but 4 required a 1.0-mL input volume for PCR positivity. CONCLUSION: For the detection of samples representing early-stage HBV infection, PCR at dilutions of 1-in-25 or lower (equivalent to a pool of < or =25 members) had greater sensitivity than CLIA-HBsAg. In contrast, samples from late-stage HBV infection were detected by PCR only with undiluted samples (0.1-mL or 1.0-mL input volumes), regardless of CLIA-HBsAg reactivity. Therefore, although NAT using minipools of 25 donations or less may be effective for the detection of early-stage HBV infection, it may not be effective for the detection of persistent HBV infection.


Assuntos
Doadores de Sangue , Sangue/imunologia , Sangue/virologia , Antígenos de Superfície da Hepatite B/análise , Vírus da Hepatite B/isolamento & purificação , Programas de Rastreamento/métodos , Testes Sorológicos/métodos , DNA Viral/sangue , Hepatite B/sangue , Hepatite B/virologia , Vírus da Hepatite B/genética , Vírus da Hepatite B/imunologia , Humanos , Imunoensaio , Medições Luminescentes , Programas de Rastreamento/normas , Reação em Cadeia da Polimerase/métodos , Reação em Cadeia da Polimerase/normas , Sensibilidade e Especificidade , Testes Sorológicos/normas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA