Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Respir Med Case Rep ; 50: 102042, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38845787

RESUMO

There is no approved drug treatment for autoimmune pulmonary alveolar proteinosis (APAP), although traditionally requires complex treatments such as whole lung lavage (WLL). We herein report on a 67-year-old man diagnosed with APAP. Treatment with atorvastatin (5 mg daily) resulted in significant improvement in symptoms, lung function, and computed tomography findings, with enhanced oxygenation, although serum anti-GM-CSF antibody levels remained elevated. This case suggests that the remission observed in this case could potentially be attributed to a direct effect of atorvastatin within the pulmonary alveoli. Statins may be considered as one of the treatment options for APAP.

2.
PLoS One ; 16(1): e0245878, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33503053

RESUMO

Respiratory-gated four-dimensional phase-contrast vastly undersampled isotropic projection reconstruction (4D PC-VIPR) is magnetic resonance (MR) imaging technique that enables analysis of vascular morphology and hemodynamics in a single examination using cardiac phase resolved 3D phase-contrast magnetic resonance imaging. The present study aimed to assess the usefulness of 4D PC-VIPR for the superior mesenteric artery (SMA) flowmetry before and after flow increase was induced by the herbal medicine Daikenchuto (TJ-100) by comparing it with Doppler ultrasound (DUS) as a current standard. Twenty healthy volunteers were enrolled in this prospective single-arm study. The peak cross-sectionally averaged velocity was measured by 4D PC-VIPR, peak velocity was measured by DUS, and flow volume (FV) of SMA and aorta were measured by 4D PC-VIPR and DUS 25 min before and after the peroral administration of TJ-100. The peak cross-sectionally averaged velocity, peak velocity, and FV of SMA measured by 4D PC-VIPR and DUS significantly increased after administration of TJ-100 (4D PC-VIPR: the peak cross-sectionally averaged velocity; p = 0.004, FV; p = 0.035, DUS: the peak velocity; p = 0.003, FV; p = 0.010). Furthermore, 4D PC-VIPR can analyze multiple blood vessels simultaneously. The ratio of the SMA FV to the aorta, before and after oral administration on the 4D PC-VIPR test also increased (p = 0.015). The rate of change assessed by 4D PC-VIPR and DUS were significantly correlated (the peak cross-sectionally averaged velocity and peak velocity: r = 0.650; p = 0.005, FV: r = 0.659; p = 0.004). Retrospective 4D PC-VIPR was a useful modality for morphological and hemodynamic analysis of SMA.


Assuntos
Imageamento por Ressonância Magnética/normas , Artérias Mesentéricas/diagnóstico por imagem , Extratos Vegetais/farmacologia , Técnicas de Imagem de Sincronização Respiratória/normas , Ultrassonografia Doppler/normas , Adulto , Velocidade do Fluxo Sanguíneo , Feminino , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Artérias Mesentéricas/efeitos dos fármacos , Artérias Mesentéricas/fisiologia , Panax , Técnicas de Imagem de Sincronização Respiratória/métodos , Ultrassonografia Doppler/métodos , Zanthoxylum , Zingiberaceae
3.
J Magn Reson Imaging ; 46(2): 595-603, 2017 08.
Artigo em Inglês | MEDLINE | ID: mdl-28152259

RESUMO

PURPOSE: To assess the performance of four-dimensional phase-contrast vastly undersampled isotropic projection reconstruction (4D PC-VIPR) at 3.0T in depicting intrarenal arteries compared with computed tomography angiography (CTA), and its correlation with arterial flowmetry in comparison with Doppler ultrasonography (DUS). MATERIALS AND METHODS: In our prospective single-arm study, subjects were 25 patients who underwent renal transplant-related surgery at our hospital between July 2011 and June 2015. In the morphological study, depictions of renal artery branches delineated by magnetic resonance angiography (MRA)/4D PC-VIPR without gadolinium contrast agent were compared in seven living transplant recipients with the same kidney delineated by CTA in seven living transplant donors. In the flowmetric study, flow velocities in the renal (main stem), segmental, and interlobar arteries during systole and diastole were measured in 12 recipients using noncontrast MRA/4D PC-VIPR, and were compared with those obtained from DUS. RESULTS: Concerning MRA, average confidence levels of delineation rated by six observers for secondary to third level renal artery branches were 82.9-100% and for the fourth to fifth branches were 60.8-89.7% (average kappa value of 0.588 [95% confidence interval: 0.522-0.653]). Total flow velocities measured using 4D PC-VIPR and DUS demonstrated significant correlations during both systole and diastole with acceptable bias (r = 0.902; P < 0.001 in systole and r = 0.734; P < 0.001 in diastole). CONCLUSION: 4D PC-VIPR was useful in generating both morphological and hemodynamic information for evaluation of transplant intrarenal arteries without the need for contrast media. LEVEL OF EVIDENCE: 2 Technical Efficacy: Stage 2 J. MAGN. RESON. IMAGING 2017;46:595-603.


Assuntos
Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Rim/diagnóstico por imagem , Artéria Renal/diagnóstico por imagem , Insuficiência Renal/diagnóstico por imagem , Ultrassonografia Doppler , Adulto , Idoso , Velocidade do Fluxo Sanguíneo , Meios de Contraste/química , Feminino , Gadolínio/química , Hemodinâmica , Humanos , Aumento da Imagem , Interpretação de Imagem Assistida por Computador , Transplante de Rim , Angiografia por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Insuficiência Renal/cirurgia , Reprodutibilidade dos Testes , Fatores de Tempo , Tomografia Computadorizada por Raios X , Transplantados
4.
J Magn Reson Imaging ; 43(2): 384-90, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26149267

RESUMO

PURPOSE: 1) To assess the usefulness of an elastic belt bracing the upper abdomen for reducing the miscalculated areas of the pancreas on 3.0T magnetic resonance elastography (MRE); 2) to test whether MRE can detect difference of stiffness between normal pancreas and the focal pancreatic diseases. MATERIALS AND METHODS: Using an initial eight normal volunteers, miscalculated areas were compared between MRE with the elastic belt and without the belt on 3.0T MRI. Then, using the belt, MRE of the normal pancreas was measured using 14 volunteers and 11 patients with focal pancreatic lesions. RESULTS: The median (95% confidence interval [CI]) percentages of correctly calculated areas were 57.4% (32.9-63.0) with the elastic belt and 35.3% (11.4-60.4) without the belt (P = 0.0078). The stiffness of each pancreatic segment of the normal volunteers (mean ± SE) was 2.37 ± 0.16 kPa for the head, 2.46 ± 0.17 kPa for the body, and 2.58 ± 0.26 kPa for the tail. The stiffness of seven pancreatic cancers was 6.06 ± 0.49 kPa, which was higher than the overall pancreatic stiffness of the normal volunteers (2.47 ± 0.11 kPa, P < 0.0001). Stiffness of the pancreatic lesions in the head of 6.03 ± 0.42 kPa, body of 5.57 ± 0.82 kPa, and tail of 5.9 ± 1.9 kPa were also higher than those of corresponding segments of the normal volunteers (P = 0.0011, 0.0029, and 0.029, respectively). CONCLUSION: With the elastic belt, miscalculation of the pancreatic stiffness was reduced. MRE showed differences of stiffness between normal pancreas and pancreatic lesions.


Assuntos
Técnicas de Imagem por Elasticidade/instrumentação , Técnicas de Imagem por Elasticidade/métodos , Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/métodos , Pâncreas/patologia , Neoplasias Pancreáticas/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Viabilidade , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Valores de Referência , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA