Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 63
Filtrar
1.
J Cardiol ; 2024 Sep 07.
Artigo em Inglês | MEDLINE | ID: mdl-39251131

RESUMO

BACKGROUND: In patients with persistent atrial fibrillation (AF), extensive ablation for substrate modification, such as linear ablation or complex fractionated atrial electrogram ablation in addition to pulmonary vein isolation (PVI) remains controversial. Previous studies investigating extensive ablation have demonstrated its varying efficacy, suggesting the possible heterogeneity of its efficacy. Aging is a major risk factor for AF and is associated with atrial remodeling. We aimed to compare the efficacy and safety of the extensive ablation strategy compared with PVI alone strategy between young and elderly patients. METHODS: This study is a post-hoc analysis of the multicenter, randomized controlled, noninferiority trial investigating the efficacy and safety of PVI-only (PVI-alone arm) compared with extensive ablation (PVI-plus arm) in patients with persistent AF (EARNEST-PVI trial). We divided the overall population into 2 groups based on age and assessed treatment effects. RESULTS: In the young group (age < 65 years, N = 206), there was no significant difference in the recurrence rate between the PVI-alone group and PVI-plus group [hazard ratio (HR): 1.00, 95%CI: 0.57-1.73, p = 0.987], whereas the recurrence rate was significantly lower in the PVI-plus group compared to the PVI-alone group in the elderly group (age ≥ 65 years, N = 291) (HR: 0.47, 95%CI: 0.29-0.76, p = 0.0021) (p for interaction = 0.0446). There were no fatal procedural complications. CONCLUSION: In patients with persistent AF, the extensive ablation strategy was more effective than the PVI-alone strategy in elderly patients, while the effectiveness of both approaches was comparable in young patients. TRIAL REGISTRATION: URL: https://clinicaltrials.gov; Unique identifier: NCT03514693. URL: https://center6.umin.ac.jp/cgi-open-bin/ctr_e/ctr_view.cgi?recptno=R000022454 Unique ID issued by UMIN: UMIN000019449.

2.
J Arrhythm ; 40(4): 1045-1048, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39139905

RESUMO

An extremely high generator impedance in the blood pool can be observed in a patient with severe polycythemia. However, ablation can be performed safely as long as the generator impedance during contact with the myocardial tissue is within acceptable limits.

3.
Int J Cardiol ; 410: 132231, 2024 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-38838745

RESUMO

BACKGROUND: Extensive ablation in addition to pulmonary vein isolation (PVI) in patients with persistent atrial fibrillation (AF) has not yielded consistent results, indicating diversity in their efficacy. Mitral regurgitation (MR) associated with AF may indicate a higher prevalence of arrhythmogenic substrate, suggesting potential benefits of extensive ablation for these patients. METHODS: This post-hoc analysis of the EARNEST-PVI trial compared PVI alone versus an extensive ablation strategy (PVI-plus) in persistent AF patients, stratified by MR presence. The primary endpoint of the study was the recurrence of AF. The secondary endpoints included death, cerebral infarction, and procedure-related complications. RESULTS: The trial included 495 eligible patients divided into MR and non-MR groups. The MR group consisted of 192 patients (89 in the PVI-alone arm and 103 in the PVI-plus arm), while the non-MR group had 303 patients (158 in the PVI-alone arm and 145 in the PVI-plus arm). In the non-MR group, recurrence rates were similar between PVI-alone and PVI-plus arms (Log-rank P = 0.47, Hazard ratio = 0.85 [95%CI: 0.54-1.33], P = 0.472). However, in the MR group, PVI-plus was significantly more effective in preventing AF recurrence (Log-rank P = 0.0014, Hazard ratio = 0.40 [95%CI: 0.22-0.72], P = 0.0021). No significant differences were observed in secondary endpoints between the two arms. CONCLUSIONS: For persistent AF patients with mild or greater MR, receiving PVI-plus was superior to PVI-alone in preventing AF recurrence. Conversely, for patients without MR, the effectiveness of extensive ablation was not demonstrated. These findings suggest tailoring ablation strategies based on MR presence can lead to better outcomes in AF management.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Insuficiência da Valva Mitral , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/complicações , Masculino , Feminino , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/complicações , Estudos Prospectivos , Ablação por Cateter/métodos , Pessoa de Meia-Idade , Idoso , Resultado do Tratamento , Veias Pulmonares/cirurgia , Seguimentos , Recidiva
4.
JACC Case Rep ; 29(13): 102378, 2024 Jul 03.
Artigo em Inglês | MEDLINE | ID: mdl-38827267

RESUMO

An 87-year-old man developed delayed cardiac tamponade 55 min after leadless pacemaker implantation and recurrent pericardial effusion 20 days later. Electrocardiogram-gated enhanced cardiac computed tomography revealed that the leadless pacemaker tines on the lateral side had penetrated the right ventricular free wall. He underwent off-pump hemostatic surgery.

5.
Circ J ; 88(7): 1068-1077, 2024 06 25.
Artigo em Inglês | MEDLINE | ID: mdl-38811199

RESUMO

BACKGROUND: It has not been fully elucidated which patients with persistent atrial fibrillation (PerAF) should undergo substrate ablation plus pulmonary vein isolation (PVI). This study aimed to identify PerAF patients who required substrate ablation using intraprocedural assessment of the baseline rhythm and the origin of atrial fibrillation (AF) triggers. METHODS AND RESULTS: This was a post hoc subanalysis using extended data of the EARNEST-PVI trial, a prospective multicenter randomized trial comparing PVI-alone and PVI-plus (i.e., PVI with added catheter ablation) arms. We divided 492 patients into 4 groups according to baseline rhythm and the location of AF triggers before PVI: Group A (n=22), sinus rhythm with pulmonary vein (PV)-specific AF triggers (defined as reproducible AF initiation from PVs only); Group B (n=211), AF with PV-specific AF triggers; Group C (n=94), sinus rhythm with no PV-specific AF trigger; Group D (n=165), AF with no PV-specific AF trigger. Among the 4 groups, only in Group D (AF at baseline and no PV-specific AF triggers) was arrhythmia-free survival significantly lower in the PVI-alone than PVI-plus arm (P=0.032; hazard ratio 1.68; 95% confidence interval 1.04-2.70). CONCLUSIONS: Patients with sinus rhythm or PV-specific AF triggers did not receive any benefit from substrate ablation, whereas patients with AF and no PV-specific AF trigger benefited from substrate ablation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Humanos , Ablação por Cateter/métodos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Veias Pulmonares/cirurgia , Veias Pulmonares/fisiopatologia , Estudos Prospectivos , Seleção de Pacientes , Resultado do Tratamento , Recidiva , Frequência Cardíaca
6.
Europace ; 26(5)2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38691672

RESUMO

AIMS: Blood stasis is crucial in developing left atrial (LA) thrombi. LA appendage peak flow velocity (LAAFV) is a quantitative parameter for estimating thromboembolic risk. However, its impact on LA thrombus resolution and clinical outcomes remains unclear. METHODS AND RESULTS: The LAT study was a multicentre observational study investigating patients with atrial fibrillation (AF) and silent LA thrombi detected by transoesophageal echocardiography (TEE). Among 17 436 TEE procedures for patients with AF, 297 patients (1.7%) had silent LA thrombi. Excluding patients without follow-up examinations, we enrolled 169 whose baseline LAAFV was available. Oral anticoagulation use increased from 85.7% at baseline to 97.0% at the final follow-up (P < 0.001). During 1 year, LA thrombus resolution was confirmed in 130 (76.9%) patients within 76 (34-138) days. Conversely, 26 had residual LA thrombi, 8 had thromboembolisms, and 5 required surgical removal. These patients with failed thrombus resolution had lower baseline LAAFV than those with successful resolution (18.0 [15.8-22.0] vs. 22.2 [17.0-35.0], P = 0.003). Despite limited predictive power (area under the curve, 0.659; P = 0.001), LAAFV ≤ 20.0 cm/s (best cut-off) significantly predicted failed LA thrombus resolution, even after adjusting for potential confounders (odds ratio, 2.72; 95% confidence interval, 1.22-6.09; P = 0.015). The incidence of adverse outcomes including ischaemic stroke/systemic embolism, major bleeding, or all-cause death was significantly higher in patients with reduced LAAFV than in those with preserved LAAFV (28.4% vs. 11.6%, log-rank P = 0.005). CONCLUSION: Failed LA thrombus resolution was not rare in patients with AF and silent LA thrombi. Reduced LAAFV was associated with failed LA thrombus resolution and adverse clinical outcomes.


Assuntos
Anticoagulantes , Apêndice Atrial , Fibrilação Atrial , Ecocardiografia Transesofagiana , Trombose , Humanos , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/complicações , Masculino , Feminino , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/fisiopatologia , Idoso , Trombose/fisiopatologia , Trombose/diagnóstico por imagem , Trombose/complicações , Pessoa de Meia-Idade , Velocidade do Fluxo Sanguíneo , Anticoagulantes/uso terapêutico , Fatores de Risco , Resultado do Tratamento , Doenças Assintomáticas , Fatores de Tempo , Cardiopatias/fisiopatologia , Cardiopatias/complicações , Cardiopatias/diagnóstico por imagem , Tromboembolia/etiologia , Tromboembolia/fisiopatologia , Idoso de 80 Anos ou mais , Função do Átrio Esquerdo
7.
J Cardiovasc Electrophysiol ; 35(4): 862-866, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38323745

RESUMO

INTRODUCTION: Persistent left superior vena cava (PLSVC) is one of the major sources of triggers and drivers of atrial fibrillation (AF). There has been no established PLSVC ablation procedure to eliminate the arrhythmogenicity along the entire length of PLSVC. METHODS AND RESULTS: A 70-year-old woman with a history of two previous catheter ablations for AF, mitral valvuloplasty, and an unroofed coronary sinus-type atrial septal defect closure underwent the redo AF ablations. The AF trigger and driver were identified within the patient's enlarged PLSVC. The AF was treated by complete PLSVC free wall isolation. CONCLUSION: Complete PLSVC free wall isolation may be an effective ablation method to eliminate the arrhythmogenicity along the entire length of the PLSVC.


Assuntos
Fibrilação Atrial , Procedimentos Cirúrgicos Cardíacos , Comunicação Interatrial , Veia Cava Superior Esquerda Persistente , Feminino , Humanos , Idoso , Veia Cava Superior/diagnóstico por imagem , Veia Cava Superior/cirurgia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Comunicação Interatrial/cirurgia
8.
Sci Rep ; 14(1): 2634, 2024 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-38302547

RESUMO

Identifying patients who would benefit from extensive catheter ablation along with pulmonary vein isolation (PVI) among those with persistent atrial fibrillation (AF) has been a subject of controversy. The objective of this study was to apply uplift modeling, a machine learning method for analyzing individual causal effect, to identify such patients in the EARNEST-PVI trial, a randomized trial in patients with persistent AF. We developed 16 uplift models using different machine learning algorithms, and determined that the best performing model was adaptive boosting using Qini coefficients. The optimal uplift score threshold was 0.0124. Among patients with an uplift score ≥ 0.0124, those who underwent extensive catheter ablation (PVI-plus) showed a significantly lower recurrence rate of AF compared to those who received only PVI (PVI-alone) (HR 0.40; 95% CI 0.19-0.84; P-value = 0.015). In contrast, among patients with an uplift score < 0.0124, recurrence of AF did not significantly differ between PVI-plus and PVI-alone (HR 1.17; 95% CI 0.57-2.39; P-value = 0.661). By employing uplift modeling, we could effectively identify a subset of patients with persistent AF who would benefit from PVI-plus. This model could be valuable in stratifying patients with persistent AF who need extensive catheter ablation before the procedure.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Resultado do Tratamento , Recidiva , Veias Pulmonares/cirurgia , Ablação por Cateter/métodos
9.
Heart Rhythm ; 21(6): 733-740, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38307310

RESUMO

BACKGROUND: The optimal duration of atrial fibrillation (AF) persistence for predicting poor outcomes after catheter ablation of long-standing AF (LsAF) and the best ablation strategy for these patients remain unclear. OBJECTIVE: We aimed to assess the impact of the duration of AF persistence on outcomes after catheter ablation of AF. METHODS: We analyzed the Efficacy of Pulmonary Vein Isolation Alone in Patients with Persistent Atrial Fibrillation (EARNEST-PVI) trial data comparing pulmonary vein isolation (PVI) alone (PVI-alone) with additional linear ablation or defragmentation (PVI-plus) in persistent AF (PerAF). Patients who received catheter ablation by contact force-sensing catheter were enrolled in the study. In patients with LsAF, the optimal cutoff duration of AF persistence was evaluated. With use of the threshold, patients with LsAF were divided into 2 groups and compared with PerAF <1 year for arrhythmia-free survival after a 3-month blanking period. RESULTS: The optimal cutoff duration was 2.4 years. Of 458 patients, arrhythmia-free survival rates for LsAF 1-2.4 years were comparable to those of PerAF (hazard ratio [HR], 1.01; 95% CI, 0.67-1.52). However, LsAF >2.4 years had a higher recurrence risk than PerAF (HR, 2.22; 95% CI, 1.42-3.47). In LsAF >2.4 years, the PVI-plus strategy showed advantages over the PVI-alone strategy (HR, 0.36; 95% CI, 0.14-0.89). However, the interaction effect between LsAF 1-2.4 years and LsAF >2.4 years did not reach statistical significance (P = .116). CONCLUSION: Whereas LsAF 1-2.4 years has similar outcomes to those of PerAF, LsAF >2.4 years was linked to higher arrhythmia recurrence risks. For LsAF >2.4 years, the PVI-plus strategy showed a potential to be superior to the PVI-alone strategy.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Recidiva , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/métodos , Masculino , Feminino , Pessoa de Meia-Idade , Veias Pulmonares/cirurgia , Fatores de Tempo , Resultado do Tratamento , Idoso , Fatores de Risco , Seguimentos
10.
J Arrhythm ; 40(1): 90-99, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38333386

RESUMO

Background: The clinical significance of left atrial local electrogram fractionation after restoration of sinus rhythm in patients with atrial fibrillation (AF) has not been elucidated. Methods: We evaluated ultrahigh-resolution maps of the left atrium (LA) during RA pacing acquired after pulmonary vein isolation in 40 patients with AF. The association between low-voltage area (LVA, <0.5 mV), fractionated electrogram area (FEA, the highlighted area with LUMIPOINT™ Complex Activation), the interval from onset of LA activation to wavefront collision at the mitral isthmus (LA activation time), and wave propagation velocity (WPV) was evaluated quantitatively. Results: The total LVA, total FEA with ≥5.0 peaks or ≥7.0 peaks were 7.0 ± 7.9 cm2, 15.9 ± 12.9 cm2, and 5.2 ± 7.5 cm2, respectively. These areas were predominantly observed in the anteroseptal region. Total LVA, total FEA with ≥5.0 peaks, and total FEA with ≥5.0 peaks in the normal voltage area (NVA: ≥0.5 mV) correlated with LA activation time (R = 0.69, 0.75, and 0.71; each p < .0001). In the anterior wall, these areas correlated with regional mean WPV (R = -0.75, -0.83, and - 0.55; each p < .0001) and the extent of slow conduction area (SCA) with WPV <0.3 m/s (R = 0.89, 0.84, 0.33; p < .0001 for LVA and FEA, p < .05 for FEA located in NVA). The anterior wall FEA with ≥7.0 peaks and that in the NVA showed a better correlation in predicting anterior wall SCA (R = 0.92 and 0.86, each p < .0001). Conclusion: Quantitative analysis of FEA together with LVA may facilitate the assessment of LA electrical remodeling.

11.
J Cardiol Cases ; 28(4): 137-140, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37818442

RESUMO

A 66-year-old female underwent persistent atrial fibrillation ablation. After pulmonary vein isolation and homogenization of low-voltage areas (LVAs), atrial tachycardia (AT) was not induced at the first session; however, it recurred one year after the procedure. During the second session, the extensive LVAs were distributed in the same area of the left atrial anterior wall and expanded possibly due to the previous LVA homogenization. The activation map revealed a macroreentrant AT circuit with the critical isthmus between the isolated right superior pulmonary vein and homogenized LVAs. Although the Ripple map algorithm failed to visualize dynamic bars, extremely low voltage and fractionated potentials (amplitude, 0.04 mV) were observed at the isthmus. Currently, there are various procedural endpoints of LVA-guided ablation (e.g. local electrogram reduction > 50 % or <0.1 mV in amplitude). In this case, incomplete transmural lesions may have led to slow conduction, which could have become an AT substrate. In cases with extensive LVAs on the left atrial anterior wall, eliminating any potential channels may be important for preventing future iatrogenic ATs. LVA-guided ablation should be performed on an individual basis, considering the potential benefits and harms based on the extent and location of LVAs. Learning objective: Currently, the procedural endpoint of low-voltage area (LVA)-guided ablation varies across studies. Because any low-voltage potentials, except scars, can cause slow conduction, LVA-guided ablation with an endpoint of local electrogram voltage reduction can unintentionally generate an iatrogenic slow conduction isthmus. LVA-guided ablation should be individually performed, considering the potential benefits and harms based on the extent and location of LVAs.

13.
JACC Case Rep ; 21: 101981, 2023 Sep 06.
Artigo em Inglês | MEDLINE | ID: mdl-37719285

RESUMO

Electromagnetic interference (EMI) between implantable left ventricular assist devices and cardiac implantable electronic devices has been observed. We demonstrated the first case of EMI between a percutaneous ventricular assist device and an implantable cardioverter-defibrillator, validated by an extra vivo simulation test. EMI might depend on the distance between devices. (Level of Difficulty: Advanced.).

14.
J Am Heart Assoc ; 12(17): e029651, 2023 09 05.
Artigo em Inglês | MEDLINE | ID: mdl-37642022

RESUMO

Background An optimal strategy for left atrial ablation in addition to pulmonary vein isolation (PVI) in patients with persistent atrial fibrillation (AF) has not been determined. Methods and Results We conducted an extended follow-up of the multicenter randomized controlled EARNEST-PVI (Efficacy of Pulmonary Vein Isolation Alone in Patients With Persistent Atrial Fibrillation) trial, which compared 12-month rhythm outcomes in patients with persistent AF between patients randomized to a PVI-alone strategy (n=248) or PVI-plus strategy (n=248; PVI followed by left atrial additional ablation, including linear ablation or ablation targeting areas with complex fractionated electrograms). The present study extended the follow-up period to 3 years after enrollment. Outcomes were compared not only between randomly allocated groups but also between on-treatment groups categorized by actually created ablation lesions. Recurrence rate of AF or atrial tachycardia (AT) was lower in the randomly allocated to PVI-plus group than the PVI-alone group (29.0% versus 37.5%, P=0.036). On-treatment analysis revealed that patients with PVI+linear ablation (n=205) demonstrated a lower AF/AT recurrence rate than those with PVI only (26.3% versus 37.8%, P=0.007). In contrast, patients with PVI+complex fractionated electrograms ablation (n=37) had an AF/AT recurrence rate comparable to that of patients with PVI only (40.5% versus 37.8%, P=0.76). At second ablation in 126 patients with AF/AT recurrence, ATs excluding common atrial flutter were more frequent in patients with PVI+linear ablation than in those with PVI only (32.6% versus 5.7%, P<0.0001). Conclusions Left atrial ablation in addition to PVI was efficacious during 3-year follow-up. Linear ablation was superior to other ablation strategies but may increase iatrogenic ATs. Registration URL: http://www.umin.ac.jp/ctr/index-j.htm; Unique identifier: UMIN000019449.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Flutter Atrial , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Veias Pulmonares/cirurgia , Átrios do Coração , Flutter Atrial/diagnóstico , Flutter Atrial/cirurgia
15.
Nat Commun ; 14(1): 4494, 2023 07 31.
Artigo em Inglês | MEDLINE | ID: mdl-37524709

RESUMO

Heart failure is a leading cause of mortality in developed countries. Cell death is a key player in the development of heart failure. Calcium-independent phospholipase A2ß (iPLA2ß) produces lipid mediators by catalyzing lipids and induces nuclear shrinkage in caspase-independent cell death. Here, we show that lysophosphatidylserine generated by iPLA2ß induces necrotic cardiomyocyte death, as well as contractile dysfunction mediated through its receptor, G protein-coupled receptor 34 (GPR34). Cardiomyocyte-specific iPLA2ß-deficient male mice were subjected to pressure overload. While control mice showed left ventricular systolic dysfunction with necrotic cardiomyocyte death, iPLA2ß-deficient mice preserved cardiac function. Lipidomic analysis revealed a reduction of 18:0 lysophosphatidylserine in iPLA2ß-deficient hearts. Knockdown of Gpr34 attenuated 18:0 lysophosphatidylserine-induced necrosis in neonatal male rat cardiomyocytes, while the ablation of Gpr34 in male mice reduced the development of pressure overload-induced cardiac remodeling. Thus, the iPLA2ß-lysophosphatidylserine-GPR34-necrosis signaling axis plays a detrimental role in the heart in response to pressure overload.


Assuntos
Insuficiência Cardíaca , Miócitos Cardíacos , Ratos , Camundongos , Masculino , Animais , Miócitos Cardíacos/metabolismo , Insuficiência Cardíaca/metabolismo , Necrose/metabolismo , Receptores Acoplados a Proteínas G/genética , Receptores Acoplados a Proteínas G/metabolismo , Remodelação Ventricular , Camundongos Knockout
16.
J Arrhythm ; 39(3): 470-473, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37324768

RESUMO

Biatrial tachycardia via Bachmann's bundle, interatrial septum, and left atrial anterior wall can be treated by left atrial anterolateral linear ablation without left atrial appendage isolation, even under mitral isthmus block.

18.
J Arrhythm ; 38(6): 1094-1098, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36524031

RESUMO

Nifekalant successfully suppressed intra-superior vena cava fibrillation, which complicated the evaluation of the gap of superior vena cava isolation.

19.
J Am Heart Assoc ; 11(16): e024916, 2022 08 16.
Artigo em Inglês | MEDLINE | ID: mdl-35929474

RESUMO

Background Modification of arrhythmogenic substrates with extensive ablation comprising linear and/or complex fractional atrial electrogram ablation in addition to pulmonary vein isolation (PVI-plus) can theoretically reduce the recurrence of atrial fibrillation. The DR-FLASH score (score based on diabetes mellitus, renal dysfunction, persistent form of atrial fibrillation, left atrialdiameter >45 mm, age >65 years, female sex, and hypertension) is reportedly useful for identifying patients with arrhythmogenic substrates. We hypothesized that, in patients with persistent atrial fibrillation, the DR-FLASH score can be used to classify patients into those who require PVI-plus and those for whom a PVI-only strategy is sufficient. Methods and Results This study is a post hoc subanalysis of the a multicenter, randomized controlled, noninferiority trial investigating efficacy and safety of pulmonary vein isolation alone for recurrence prevention compared with extensive ablation in patients with persistent atrial fibrillation (EARNEST-PVI trial). This analysis focuses on the relationship between DR-FLASH score and the efficacy of different ablation strategies. We divided the population into 2 groups based on a DR-FLASH score of 3 points. A total of 469 patients were analyzed. Among those with a DR-FLASH score >3 (N=279), the event rate of atrial arrhythmia recurrence was significantly lower in the PVI-plus arm than in the PVI-only arm (hazard ratio [HR], 0.45 [95% CI, 0.28-0.72]; P<0.001). In contrast, among patients with a DR-FLASH score ≤3 (N=217), no differences were observed in the event rate of atrial arrhythmia recurrence between the PVI-only arm and the PVI-plus arm (HR, 1.08 [95% CI, 0.61-1.89]; P=0.795). There was significant interaction between patients with a DR-FLASH score >3 and DR-FLASH score ≤3 (P value for interaction=0.020). Conclusions The DR-FLASH score is a useful tool for deciding the catheter ablation strategy for patients with persistent atrial fibrillation. Registration URL: https://clinicaltrials.gov; Unique identifier: NCT03514693.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Técnicas Eletrofisiológicas Cardíacas , Feminino , Humanos , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
20.
Circ J ; 86(8): 1207-1216, 2022 07 25.
Artigo em Inglês | MEDLINE | ID: mdl-34911901

RESUMO

BACKGROUND: Women experience more severe arrhythmogenic substrates. This study hypothesized that an extensive ablation strategy, such as linear ablation and/or complex fractionated atrial electrogram (CFAE) ablation in addition to pulmonary vein isolation (PVI-plus), might be effective for women, whereas the PVI alone strategy (PVI-alone) might be sufficient for men to maintain sinus rhythm. The aim of this study was to test this hypothesis.Methods and Results: This study is a post-hoc subanalysis of the EARNEST-PVI trial focusing on sex differences in the efficacies of different ablation strategies. The EARNEST-PVI trial was a prospective, multicenter, randomized, and open-label non-inferiority trial in patients with persistent AF. The primary endpoint was recurrence of AF, atrial flutter, or atrial tachycardia. The EARNEST-PVI trial randomized 376 (76%) men (PVI-alone 186, PVI-plus 190) and 121 (24%) women (PVI-alone 63, PVI-plus 58). The event rate was significantly lower for men and numerically lower for women in the PVI-plus than the PVI-alone group, and there was no interaction between men and women (hazard ratio, 0.641; 95% confidence interval, 0.417-0.985; P value, 0.043 for men vs. hazard ratio, 0.661; 95% confidence interval, 0.352-1.240; P value, 0.197 for women; P value for interaction, 0.989). CONCLUSIONS: The superiority of the extensive ablation strategy vs. the PVI-alone strategy for persistent AF was consistent across both sexes.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Feminino , Humanos , Masculino , Estudos Prospectivos , Veias Pulmonares/cirurgia , Recidiva , Caracteres Sexuais , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA