Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 55
Filtrar
1.
Ann Anat ; 250: 152143, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37572764

RESUMO

BACKGROUND: We aimed to assess the accuracy of artificial intelligence (AI) based real-time anatomy identification for ultrasound-guided peripheral nerve and plane block in eight regions in this prospective observational study. METHODS: After obtaining ethics committee approval and written informed consent from 40 healthy volunteers (20 men and 20 women, between 18 and 72 years old), an ultrasound device installed with AI software (Nerveblox, SmartAlfa, Turkey) were used to scan regions of the cervical plexus, brachial plexus, pectoralis (PECS), rectus sheet, femoralis, canalis adductorius, popliteal, and ESP by three anesthesiology trainees. During scanning by a trainee, once software indicates 100 % scan success of associated anatomic landmarks, both raw and labeled ultrasound images were saved, assessed, and validated using a 6-point scale between 0 and 5 by two expert validators. Evaluation scores of the validators for each block were compared according to demographics (gender, age, and BMI) and block type exists. RESULTS: The scores were not different except ESP, femoralis, and cervical plexus regions between the experts. The mean scores of the experts for the PECS, popliteal and rectus sheath were significant between males and females (p < 0.05). In terms of BMI, significant differences in the scores were observed only in the canalis adductorius, brachial plexus, and ESP regions (p < 0.05). CONCLUSIONS: Ultrasound guided AI-based anatomy identification was performed in commonly used eight block regions by the trainees where AI technology can successfully interpret the anatomical structures in real-time sonography which would be valuable in assisting anesthesiologists.


Assuntos
Inteligência Artificial , Plexo Braquial , Masculino , Humanos , Feminino , Adolescente , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Idoso , Ultrassonografia de Intervenção/métodos , Ultrassonografia , Plexo Braquial/diagnóstico por imagem , Estudos Prospectivos
2.
Acad Radiol ; 30(10): 2172-2180, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37357048

RESUMO

RATIONALE AND OBJECTIVES: To compare the efficacy of two thermal ablation techniques (radiofrequency vs microwave ablation) in the treatment of benign thyroid nodules. MATERIALS AND METHODS: A total of 80 patients with 80 nodules underwent thermal ablation of thyroid nodules with either radiofrequency ablation (RFA) (23 females and 14 males; mean age 41 ± 9years) or microwave ablation (MWA) (28 females and 15 males; mean age 45 ± 11years). Ultrasound assessments were made at the 1st, 3rd, 6th, and 12th months after the ablation procedure. RESULTS: The mean initial volume of the nodules (RFA: 15.6 mL [min 2.5-max 74]; MWA: 40 mL [min 2-max 205]) was statistically significantly different (P < .001). The following were the volume reduction rates of nodules at 1, 3, 6, and 12months, respectively: after RFA: 46.8 ± 13.5%, 62.9 ± 13.6%, 71.6 ± 11.9%, and 77.9 ± 10.3%. After MWA: 38.7 ± 12.5%, 54 ± 15.3%, 59.6 ± 12.5%, and 65 ± 11.3%. For all months, volume reduction rates in the RFA group were significantly higher than those in the MWA group (P < .05). One patient treated by RFA reported an abscess formation and another patient treated by RFA had a self-limiting hematoma, who recovered without any further treatment. Also, in the MWA group, one patient had abscess formation and another patient had transient recurrent nerve paralysis, who recovered with appropriate treatment. CONCLUSION: Both methods are effective in treating benign thyroid nodules; however, RFA provides a better volume reduction.


Assuntos
Ablação por Cateter , Ablação por Radiofrequência , Nódulo da Glândula Tireoide , Masculino , Feminino , Humanos , Adulto , Pessoa de Meia-Idade , Nódulo da Glândula Tireoide/diagnóstico por imagem , Nódulo da Glândula Tireoide/cirurgia , Ablação por Cateter/métodos , Micro-Ondas/uso terapêutico , Abscesso , Resultado do Tratamento , Ablação por Radiofrequência/métodos , Estudos Retrospectivos
3.
Acad Radiol ; 30(9): 1832-1837, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-36628802

RESUMO

RATIONALE AND OBJECTIVES: The recently developed ultrasound based tools using attenuation coefficient (AC) and scatter distribution coefficient (SDC) values can be used to quantify hepatic fat content in patients with non-alcoholic fatty liver disease (NAFLD). However, currently the impact of respiratory phase on these measurements is not known. The purpose of this study is to compare AC and SDC measurements acquired at peak inspiration and end expiration phases. MATERIALS AND METHODS: AC and SDC measurements were obtained in 50 patients with NAFLD. Tissue Attenuation Imaging (TAI) and Tissue Scatter Distribution Imaging (TSI) tools were utilized to measure AC and SDC values, respectively. Five measurements were performed at respiratory phases using TAI and TSI tools and the median values were noted. Subgroup analyses were performed and Wilcoxon signed rank test was used for comparison of the measurements. RESULTS: The median values of the AC measurements at peak inspiration and end expiration phases were 0.87 dB/cm/MHz and 0.89 dB/cm/MHz, respectively. The median values of the SDC measurements at peak inspiration and end expiration phases were 97.91 and 96.62, respectively. There were no statistically significant differences in AC and SDC measurements between the respiratory phases except for AC measurements in BMI <30 kg/m2 subgroup. CONCLUSION: Our results revealed that respiratory phases have no impact on SDC measurements. However, while the AC measurements in BMI ≥30 kg/m2 subgroup showed no significant difference, there was a significant difference in AC measurements in BMI <30 kg/m2 subgroup between the respiratory phases.


Assuntos
Hepatopatia Gordurosa não Alcoólica , Humanos , Hepatopatia Gordurosa não Alcoólica/diagnóstico por imagem , Fígado/diagnóstico por imagem , Ultrassonografia/métodos
4.
Can Assoc Radiol J ; 74(2): 362-369, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36113064

RESUMO

Purpose: To assess the diagnostic performances of novel Tissue attenuation imaging (TAI) and Tissue scatter distribution imaging (TSI) tools in quantification of liver fat content using magnetic resonance imaging proton density fat fraction (MRI PDFF) as reference standard. Methods: Eighty consecutive patients with known or suspected non-alcoholic fatty liver disease (NAFLD) who volunteered to participate in the study comprised the study cohort. All patients underwent MRI PDFF scan and quantitative ultrasound (QUS) imaging using TAI and TSI tools. The cutoff values of ≥5%, ≥16.3% and ≥21.7% on MRI PDFF were used for mild, moderate and severe steatosis, respectively. Area under the Receiver operating characteristic (AUROC) curves were used to assess the diagnostic performance of TAI and TSI in detecting different grades of hepatic steatosis. Results: The AUROCs of TAI and TSI tools in detecting hepatosteatosis (MRI PDFF ≥5%), were 0.95 [95% Confidence Interval (CI): 0.91-0.99] (P < 0.001) and 0.96 (95% CI: 0.93-0.99) (P < 0.001), respectively. In distinguishing between different grades of steatosis, the values of 0.75, 0.86 and 0.96 dB/cm/MHz have 88%, 88% and 100% sensitivity, respectively, for TAI tool; and the values of 92.44, 96.64 and 99.45 have 90%, 92% and 91.7% sensitivity, respectively, for TSI tool. Conclusion: TAI and TSI tools accurately quantify liver fat content and can be used for the assessment and grading of hepatosteatosis in patients with known or suspected NAFLD.


Assuntos
Hepatopatia Gordurosa não Alcoólica , Humanos , Hepatopatia Gordurosa não Alcoólica/diagnóstico , Hepatopatia Gordurosa não Alcoólica/patologia , Prótons , Fígado/patologia , Imageamento por Ressonância Magnética/métodos , Padrões de Referência
5.
J Ultrasound Med ; 42(4): 833-841, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35778902

RESUMO

OBJECTIVES: To assess interobserver variability in ultrasound-based quantitative liver fat content measurements and to determine how much time these quantitative ultrasound (QUS) techniques require. METHODS: One hundred patients with known or suspected of having nonalcoholic fatty liver disease were included in this prospective study. Two observers who were blinded to each other measurements performed tissue attenuation imaging (TAI) and tissue scatter distribution imaging (TSI) techniques independently. Both observers assessed hepatic steatosis visually and obtained 5 measurements for each QUS technique and the median values of the measurements were recorded. Spearman's correlation test was used to assess the correlation between QUS measurements and visual hepatic stetaosis grades. Intraclass correlation coefficient (ICC) test was used to assess interobserver variability in QUS measurements. RESULTS: The median values of TAI measurements for the observers 1 and 2 were 0.75 and 0.74 dB/cm/MHz, respectively. The median values of TSI measurements for the observers 1 and 2 were 93.53 and 92.58, respectively. The interobserver agreement in TAI (ICC: 0.970) and TSI (ICC: 0.938) measurements were excellent. The mean of the required time period for TAI technique were 55.1 ± 7.8 and 59.9 ± 6.6 seconds for the observers 1 and 2, respectively. The mean of the required time period for TSI technique were 49.1 ± 5.8 and 54.1 ± 5.4 seconds for the observers 1 and 2, respectively. CONCLUSION: The current study revealed that both TAI and TSI techniques are highly reproducible and can be implemented into daily practice with little additional time requirement.


Assuntos
Fígado , Hepatopatia Gordurosa não Alcoólica , Humanos , Variações Dependentes do Observador , Estudos Prospectivos , Fígado/diagnóstico por imagem , Hepatopatia Gordurosa não Alcoólica/diagnóstico por imagem , Ultrassonografia/métodos
6.
Ultrasound Q ; 38(1): 89-93, 2022 Jan 10.
Artigo em Inglês | MEDLINE | ID: mdl-35001026

RESUMO

ABSTRACT: The purposes of this study are to measure the thickness and stiffness of diaphragm in association with the respiratory cyclus and to assess the reproducibility of these measurements. Forty individuals who are volunteered for participating diaphragm evaluation were included in the study. Two radiologists with 14 and 15 years of experiences in abdominal ultrasound performed all examinations independently. Furthermore, 8 chronic obstructive pulmonary disease (COPD) patients were examined by only the first radiologist. Gray scale and shear-wave elastography imaging of only the right hemidiaphragm of all participants were performed. Thickness and stiffness of diaphragm were measured at the peak inspiration and end expiration phases. Intraclass correlation coefficients test was used to assess the interobserver agreement. The thickness and stiffness of diaphragm significantly increased with inspiration (P < 0.001). The mean ± SD stiffness of diaphragm in peak inspiration and end expiration phases was 51.84 ± 16.83 kPa and 38.49 ± 9.42 kPa, respectively, for the first radiologist and 49.61 ± 13.83 kPa and 37.52 ± 10.71 kPa, respectively, for the second radiologist. Intraclass correlation coefficient values for diaphragm stiffness were 0.667 and 0.736 in peak inspiration and end expiration phases, respectively. In COPD patients, there was no significant difference between stiffness measurements of respiratory phases. In conclusion, the current study revealed that diaphragm thickness and stiffness increase at inspiration, and these measurements are slightly more reproducible at the end of expiration. However, diaphragm stiffness changes between respiratory phases may not be valid for COPD patients, and this may be related to loss of force-generating capacity of diaphragm in COPD patients.


Assuntos
Técnicas de Imagem por Elasticidade , Diafragma/diagnóstico por imagem , Técnicas de Imagem por Elasticidade/métodos , Humanos , Reprodutibilidade dos Testes , Tórax , Ultrassonografia
7.
Acta Radiol ; 63(4): 520-526, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33730859

RESUMO

BACKGROUND: Multiple sclerosis (MS) is a chronic neuroinflammatory disease characterized by inflammation involving the peripheral nerves. Shear wave elastography (SWE) is potentially a method of choice for detecting peripheral nerve involvement. PURPOSE: To compare the degree of thickening and nerve elasticity of brachial plexus (BP) nerve roots and evaluate the usefulness of sonoelastography in patients with clinically diagnosed MS without brachial plexopathy. MATERIAL AND METHODS: Thirty-two patients with MS and 32 controls were included in the study. Bilateral C5, C6, and C7 mean nerve root diameters, and mean elasticity values in kiloPascal (kPa) were measured in the patient and control groups. The relationship between the age, height, and weight values and nerve diameter-elasticity values of the patient and control groups was compared. RESULTS: The elasticity values of the C5 and C6 nerve roots were increased, and the nerve root thickness was decreased in the MS group compared to that in the control (P < 0.05). There was no difference between the C7 mean nerve root elasticity (kPa) and diameter measurements in the patient and control groups (P > 0.05). CONCLUSION: Our study showed an increase in the BP nerve root elasticity values (kPa) in patients with MS compared to that of the control group and a decrease in diameter values thought to be related to the possible chronic atrophic process. The results are consistent with the demyelinating process of the peripheral nervous system (PNS) due to MS.


Assuntos
Plexo Braquial/diagnóstico por imagem , Plexo Braquial/fisiopatologia , Técnicas de Imagem por Elasticidade/métodos , Esclerose Múltipla/fisiopatologia , Adolescente , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Adulto Jovem
9.
J Anesth ; 35(4): 591-594, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34008072

RESUMO

We aimed to assess the accuracy of an artificial intelligence (AI)-based real-time anatomy identification software specifically developed to ease image interpretation intended for ultrasound-guided peripheral nerve block (UGPNB). Forty healthy participants (20 women, 20 men) were enrolled to perform interscalene, supraclavicular, infraclavicular, and transversus abdominis plane (TAP) blocks under ultrasound guidance using AI software by anesthesiology trainees. During block practice by a trainee, once the software indicates 100% scan success of each block associated anatomic landmarks, both raw and labeled ultrasound images were saved, assessed, and validated using a 5-point scale by expert validators. When trainees reached 100% scan success, accuracy scores of the validators were noted. Correlation analysis was used whether the relationship (r) according to demographics (gender, age, and body mass index: BMI) and block type exist. The BMI (kg/m2) and age (year) of participants were 22.2 ± 3 and 32.2 ± 5.25, respectively. Assessment scores of validators for all blocks were similar in male and female individuals. Mean assessment scores of validators were not significantly different according to age and BMI except for TAP block, which was inversely correlated with age and BMI (p = 0.01). AI technology can successfully interpret anatomical structures in real-time sonography while assisting young anesthesiologists during UGPNB practice.


Assuntos
Inteligência Artificial , Bloqueio Nervoso , Músculos Abdominais/diagnóstico por imagem , Feminino , Humanos , Masculino , Nervos Periféricos/diagnóstico por imagem , Ultrassonografia , Ultrassonografia de Intervenção
10.
Abdom Radiol (NY) ; 46(7): 3238-3244, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33723676

RESUMO

PURPOSE: In this study, we investigated the diagnostic efficacy of 2D-Shear Wave Elastography (2D-SWE) in detecting stages of liver fibrosis and determining the disease-specific cut-off values in patients with chronic hepatitis B and C infection, using histopathological analysis as the reference method. METHOD: Our study included 103 consecutive adult patients with chronic hepatitis B and C infection (CHB and CHC) who had liver biopsy within three months of elastography examination. A real-time 2D-SWE was performed using the LOGIQ E9 system (GE Medical Systems, Wisconsin, USA). The correlation between the liver stiffness measurements and the METAVIR scores was evaluated. The diagnostic performance of 2D-SWE was assessed, and cut-off values were set. RESULTS: We found a statistically significant positive correlation between elastography values and the degree of liver fibrosis (Spearman's correlation coefficient = 0.76 and 0.83 for CHB and CHC; respectively) (p = 0.0001). The stiffness cut-off values were F ≥ 1: 5.92 kPa, F ≥ 2: 7.69 kPa, F ≥ 3: 8.97 kPa, F ≥ 4: 12.15 kPa in CHB; and F ≥ 1: 6.09 kPa, F ≥ 2: 7.81 kPa, F ≥ 3: 9.0 kPa, F ≥ 4: 12.47 kPa in CHC patients. CONCLUSION: 2D-SWE is reliable and accurate for the diagnosis of liver fibrosis. In selected patients, 2D-SWE may be useful in reducing the need for liver biopsy when staging fibrosis. Further studies in larger prospective series are needed to confirm these results and determine the most appropriate cut-off values for each stage of liver fibrosis.


Assuntos
Técnicas de Imagem por Elasticidade , Hepatite B Crônica , Adulto , Correlação de Dados , Hepatite B Crônica/complicações , Hepatite B Crônica/diagnóstico por imagem , Hepatite B Crônica/patologia , Humanos , Fígado/diagnóstico por imagem , Fígado/patologia , Cirrose Hepática/diagnóstico por imagem , Cirrose Hepática/patologia , Estudos Prospectivos
11.
Diagn Interv Radiol ; 27(2): 195-205, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33599210

RESUMO

PURPOSE: We aimed to evaluate the effectiveness of speckle tracking carotid strain (STCS) technique, which enables measurement of arterial stiffness and strain parameters, in the detection of early atherosclerotic findings in type 1 diabetes mellitus (T1DM). METHODS: We prospectively enrolled 30 T1DM patients and 30 age- and sex-matched control participants with no history of cardiovascular disease. All study population underwent carotid ultrasonography. Radial and circumferential movement of the common carotid artery (CCA) in the transverse plane as the well as the radial movement of the CCA in the longitudinal plane were calculated automatically by using the STCS method. In addition, the strain (%), strain rate (per second), and peak circumferential and radial displacements (mm) were calculated. Arterial stiffness parameters, such as elastic modulus, distensibility, arterial compliance, and ß-stiffness index, were calculated using the radial measurements. The mean value of the carotid intima media thickness (CIMT) was calculated semi-automatically for each CCA, in the longitudinal plane. We also analyzed the patients' overall body composition. RESULTS: T1DM and control groups were compared in terms of strain and stiffness parameters and no statistically significant difference was found (p > 0.05). CIMT was higher in diabetic patients than in the control group (p = 0.039). In both groups, age was correlated with all arterial stiffness and strain parameters (p < 0.05). The duration of diabetes was also correlated with ß-stiffness index, distensibility, and elastic modulus in the longitudinal plane (p < 0.05). In the diabetic group, abdominal fat ratio, whole body fat ratio, and fat mass were correlated with radial and circumferential displacement and strain parameters in transverse plane, and radial displacement in longitudinal plane (p < 0.05, for each). Diabetic patients were divided into subgroups according to the presence of nephropathy and dyslipidemia. Although no significant difference was found between the groups in terms of CIMT, patients with nephropathy had higher values for transverse and longitudinal elastic modulus, pulse-wave velocity, and longitudinal ß-stiffness index, as well as lower values for longitudinal arterial compliance and distensibility, compared with patients without nephropathy (p < 0.05). Also, patients with dyslipidemia had higher longitudinal ß-stiffness and elastic modulus values compared with patients without dyslipidemia (p < 0.05). CONCLUSION: STCS ultrasonography is an effective, easy, and noninvasive method for evaluating the arterial elasticity. It may provide an early assessment of atherosclerosis in patients with T1DM, especially in the presence of nephropathy and dyslipidemia; thus, together with CIMT measurement, it may be used more frequently to detect subclinical damage and stratify atherosclerosis.


Assuntos
Diabetes Mellitus Tipo 1 , Rigidez Vascular , Artérias Carótidas/diagnóstico por imagem , Artéria Carótida Primitiva/diagnóstico por imagem , Espessura Intima-Media Carotídea , Diabetes Mellitus Tipo 1/complicações , Diabetes Mellitus Tipo 1/diagnóstico por imagem , Humanos , Ultrassonografia
12.
Acad Radiol ; 28(10): 1383-1388, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-33402299

RESUMO

RATIONALE AND OBJECTIVES: The objective of the study was to assess the diagnostic efficiency of shear wave elastography in the grading of meniscal degeneration compared to magnetic resonance imaging (MRI) as a reference standard. MATERIALS AND METHODS: Fifty patients were included in the study (who had bilateral knee MRI). Tissue elasticity was measured in the coronal plane from the meniscus body in kilopascal. Nonparametric testing (Mann-Whitney U) was utilized to assess the differences between mean elasticity of the meniscus tissue, gender. The inter-intraobserver agreement was determined by the intraclass correlation coefficient. The correlations between the mean elasticity of the meniscus versus age, height, and body mass index were calculated via the "Pearson Correlation Coefficient Test." The relationship between MRI meniscal degeneration grading and elastography elasticity module was determined via the "Spearman Correlation Test." A p value less than 0.05 was considered statistically significant. RESULTS: Inter-intraobserver intraclass correlation coefficient of the lateral and medial meniscus mean stiffness values were good or excellent (>0.8). A statistically significant increase in stiffness of meniscus tissue was observed with an increase in age (p = 0.003 for medial menisci, 0.006 for lateral menisci). Tissue stiffness was higher in the medial meniscus than the lateral meniscus (p < 0.001). A positive correlation was observed between the MRI meniscal degeneration grade and tissue stiffness (p < 0.05). Additionally, mean stiffness values from lateral and medial menisci were higher in the group with degeneration (p < 0.0001). CONCLUSION: Meniscus stiffness is increased with aging. There was a statistically significant positive correlation between meniscal stiffness and degeneration grading in MRI.


Assuntos
Técnicas de Imagem por Elasticidade , Menisco , Humanos , Imageamento por Ressonância Magnética , Menisco/diagnóstico por imagem
13.
Aging Clin Exp Res ; 33(3): 573-580, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32406014

RESUMO

BACKGROUND: Studies in mice have suggested that sarcopenic animals may have atrophic diaphragmatic muscles; however, to date, no clinical studies are available. AIMS: To investigate whether the diaphragmatic thickness is affected in older patients with sarcopenia and if this is associated with impaired respiratory functions. METHODS: Thirty sarcopenic and 30 non-sarcopenic elderly patients aged over 65 were included. All patients underwent comprehensive geriatric assessment. The diagnosis of sarcopenia was made according to the criteria of the European Working Group on Sarcopenia in Older People. Ultrasonographic evaluations of the patients were carried out by an experienced radiologist. Diaphragmatic thickness was measured in three positions: end of deep inspiration, quiet breathing, end of forced expiration. Peak expiratory flow (PEF) rate was evaluated by a peak flow meter. RESULTS: The mean age of the patients was 77 ± 6 years, and 58% were females. Diaphragmatic thickness in three different positions (deep inspiration [2.3 mm (min-max: 1.3-4.1) vs. 2.5 mm (min-max: 1.9-4.9)], quiet breathing [1.8 mm (min-max: 1.0-2.8) vs. 2.00 mm (min-max: 1.3-3.9)] and end of forced expiration [1.1 mm (min-max: 0.7-2.5) vs. 1.5 mm (min-max: 0.5-3.4)]) were found to be thinner in sarcopenic patients compared to non-sarcopenics (p = 0.02, p = 0.02, p < 0.01, respectively). Also, PEF rate results were lower in patients with sarcopenia (245 L/min [min-max: 150-500] vs. 310 L/min [min-max: 220-610], p < 0.01). Diaphragmatic muscle thicknesses in all three positions were independently associated with sarcopenia status of the participants. CONCLUSIONS: Our results suggest that sarcopenia in older people may be associated with reduced diaphragmatic muscle thickness and respiratory functions. Findings are needed to be confirmed in further multicenter studies with big sample sizes.


Assuntos
Sarcopenia , Idoso , Idoso de 80 Anos ou mais , Animais , Estudos Transversais , Avaliação Geriátrica , Humanos , Camundongos , Músculos , Testes de Função Respiratória , Sarcopenia/diagnóstico por imagem
14.
Abdom Radiol (NY) ; 46(5): 1941-1946, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33231728

RESUMO

OBJECTIVE: To determine the accuracy of 2D shear-wave elastography (2D-SWE) in pediatric age group patients in differentiating clinically insignificant and significant liver fibrosis using METAVIR fibrosis scoring system as the gold standard. INTRODUCTION: Liver biopsy has long been the gold standard in liver fibrosis diagnosis. However, due to probable complications and sampling variabilities, the need for more accurate and non-invasive techniques has increased. 2D-SWE is a non-invasive technique used in the evaluation of liver stiffness and utilized more and more in routine clinical practice with recent advances and researches. MATERIALS AND METHODS: In this retrospective single-center study, we included 46 pediatric age group patients who had a liver parenchymal biopsy and 2D-SWE evaluation regardless of etiology. For 2D-SWE, the LOGIQ E9 system (GE Medical Systems, Wisconsin, USA) and, for histopathological evaluation, METAVIR fibrosis scoring system were utilized. Patients were further subgrouped as clinically insignificant (METAVIR Score F0-1) and significant (METAVIR Score F2-4). The Kolmogorov-Smirnov and Mann-Whitney U tests were employed for statistical analysis. The diagnostic accuracy of 2D-SWE was assessed, and cutoff values were set by ROC curve analysis. RESULTS: kPa values were statistically different between clinically significant and insignificant fibrosis patient groups (p < 0.001). kPa value of 8.92 was designated as the best cutoff value according to the Youden Index. CONCLUSION: 2D-SWE is one of the non-invasive techniques in the evaluation of liver fibrosis. Our findings suggest that 2D-SWE accurately differentiate clinically insignificant and significant liver fibrosis.


Assuntos
Técnicas de Imagem por Elasticidade , Biópsia , Criança , Humanos , Fígado/diagnóstico por imagem , Fígado/patologia , Cirrose Hepática/diagnóstico por imagem , Cirrose Hepática/patologia , Estudos Retrospectivos
15.
J Med Ultrason (2001) ; 47(4): 609-615, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32705628

RESUMO

PURPOSE: The first aim of this study was to evaluate changes in the stiffness of the medial gastrocnemius muscle (GM) after a botulinum toxin A (BoNT-A) injection in children with cerebral palsy (CP) using shear wave elastography (SWE). We also wanted to investigate the usability of SWE for evaluating spasticity in a clinical setting. The second aim of this study was to show how treatment of the gastrocnemius muscle spasticity caused a change in the elasticity of the anterior tibial (TA) muscle. METHODS: Twenty-four pediatric patients diagnosed with a spastic type of CP, who were scheduled to receive a BoNT-A injection in the gastrocnemius muscle, were included in the study. There was a total of 43 lower extremities to evaluate, and muscle stiffness was measured before the injection and a month post injection using SWE. The physiatrist evaluated muscle spasticity using the Modified Ashworth Scale (MAS) and the Modified Tardieu Scale at about the same time. RESULTS: SWE values of the GM (pre-BoNT-A: 45.9 ± 6.5 kPa, post-BoNT-A: 25.0 ± 5.7 kPa) decreased significantly post BoNT-A injection (P < 0.01). SWE measurements of the GM had positive correlations with MAS, V1X, V3X, and R2-R1 (P < 0.01); and negative correlations with R2 and R1 (P < 0.05). SWE values of the TA muscle (pre: 36.9 ± 7.9 kPa, post: 28.4 ± 5.2 kPa) decreased significantly (P < 0.01). CONCLUSION: Quantitative measurement of muscle stiffness using SWE may provide important information for the evaluation of spasticity and treatment efficiency in pediatric CP patients.


Assuntos
Toxinas Botulínicas Tipo A/uso terapêutico , Paralisia Cerebral/complicações , Técnicas de Imagem por Elasticidade/métodos , Espasticidade Muscular/tratamento farmacológico , Músculo Esquelético/diagnóstico por imagem , Fármacos Neuromusculares/uso terapêutico , Toxinas Botulínicas Tipo A/administração & dosagem , Criança , Pré-Escolar , Elasticidade , Feminino , Humanos , Injeções Intramusculares , Masculino , Espasticidade Muscular/etiologia , Fármacos Neuromusculares/administração & dosagem , Estudos Prospectivos , Resultado do Tratamento
16.
Clin Imaging ; 65: 85-93, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32387801

RESUMO

PURPOSE: To evaluate the efficacy of attenuation measurement function (ATT), a newly developed quantitative ultrasonography(US) method based on measurement of the attenuation coefficient, using unenhanced computerized tomography(CT) attenuation values as a reference standard, for the detection and measurement of hepatosteatosis. MATERIAL AND METHODS: A total of 98 patients were analyzed. The diagnostic ability of ATT was evaluated using receiver operating characteristic (ROC) curve analysis, and the correlation between liver attenuation index (LAI), the liver-to-spleen attenuation ratio (CTL/S), liver attenuation value (CTL), and ATT was determined. RESULTS: ATT is negatively correlated with LAI (r = -0.571, p < 0.001), CTL/S (r = -0.532, p < 0.001), and mean CTL (r = -0.50, p < 0.001). A significant difference was found between ATT values of patients with different grades of hepatosteatosis (p < 0.001). A significant difference was found between ATT values of patients with LAI < -10 and LAI > -10, CTL < 40 and CTL > 40, and CTL/S < 1 and CTL/S > 1 (p < 0.001). An ATT ≥ 0.665 showed a sensitivity of 100% and a specificity of 90% in diagnosing moderate-severe steatosis. The corresponding area under the ROC curve(AUROC) was 0.935. The intraclass correlation coefficient for the interobserver variability of ATT was 0.907 (95% CI, 0.85-0.95). CONCLUSION: In conclusion, ATT values for evaluation of hepatosteatosis was closely correlated with the degree of hepatosteatosis and liver fat content. It can be used as a noninvasive method in the diagnosis and follow-up.


Assuntos
Fígado Gorduroso/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Fígado Gorduroso/diagnóstico , Feminino , Humanos , Transplante de Fígado/métodos , Masculino , Pessoa de Meia-Idade , Curva ROC , Sensibilidade e Especificidade , Ultrassonografia
17.
Eur J Radiol ; 128: 109038, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32422550

RESUMO

PURPOSE: To evaluate the effects of aging on skeletal muscle stiffness in relaxed and contracted status using shear wave elastography (SWE). MATERIALS AND METHODS: A total of 57 participants were enrolled to this institutional review board approved prospective study. Medial head of the gastrocnemius muscle (GM) of all participants were examined bilaterally by a single radiologist in prone position. Muscle thickness, stiffness values in both relaxed and contracted status were measured. Stiffness increase rate (SIR) was calculated for all muscles. The Spearman's correlation test was used for correlation analyses. Mann-Whitney U test was used to compare subgroups. RESULTS: The mean age of the participants was 41.15 ±â€¯16.19 (range, 18-74). The means of stiffness values of medial head of GM were 12.51 ±â€¯2.56 kPa and 81.74 ±â€¯15.77 kPa in relaxed and contracted status, respectively. The mean of SIR values was 5.62 ±â€¯1.05 (range, 3.18-8.66). The stiffness values of relaxed and contracted medial head of GM had moderate to strong inverse correlations with age for both dominant and non-dominant extremities (r range: -0.703 to -0.590). Age subgroup analyses revealed significant differences in muscle thickness and stiffness values, whereas no significant difference was found in SIR values. CONCLUSION: In conclusion, despite the decrease in stiffness of skeletal muscle with advancing age, SIR remained similar. Any improvement in stiffness values of skeletal muscle in relaxed status may play pivotal role in the management of sarcopenia.


Assuntos
Envelhecimento/fisiologia , Técnicas de Imagem por Elasticidade/métodos , Músculo Esquelético/diagnóstico por imagem , Músculo Esquelético/fisiopatologia , Adolescente , Adulto , Idoso , Elasticidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Estatísticas não Paramétricas , Adulto Jovem
18.
Turk J Med Sci ; 49(3): 761-768, 2019 06 18.
Artigo em Inglês | MEDLINE | ID: mdl-31062941

RESUMO

Background/aim: This study aimed to evaluate the clinical efficacy of radiofrequency ablation (RFA) and cryotherapy and to scrutinize the therapeutic success of the RENAL (radius, exophytic/endophytic, nearness to collecting system, anterior/posterior, and location) nephrometry score in terms of possible complications and the predictive status of oncological results. Materials and methods: Forty-five patients with biopsy-proven renal cell carcinomas (32 males, 13 females) treated with RFA and cryotherapy were included. Patients were 22­90 years old (average: 59.2 years). Statistical analyses were performed using SPSS for Windows. Results: A total of 79 lesions with dimensions varying between 0.9 and 4.5 cm (average: 2.2 cm) were ablated. Complete ablation was achieved for 72 (91.1%) lesions. Six repeat RFA sessions were applied for 4 (5%) lesions with residue/recurrence. The average RENAL nephrometry scores of lesions that underwent complete ablation and those that developed residue/recurrence were 6.3 and 7.7, respectively. The average recurrence-free survival time was 34.8 months (range: 3­55 months), while it was 44.6 months (range: 6­55 months) for cryotherapy and 28.6 months (range: 3­50 months) for RFA. Conclusion: Ablative therapies are minimally invasive and effective methods for treating small renal tumors. RENAL nephrometry scoring is a valuable system for standardizing renal tumors and evaluating the success of ablative therapies, possible complications, and oncological results.


Assuntos
Criocirurgia/estatística & dados numéricos , Testes de Função Renal , Neoplasias Renais , Ablação por Radiofrequência/estatística & dados numéricos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Neoplasias Renais/epidemiologia , Neoplasias Renais/fisiopatologia , Neoplasias Renais/cirurgia , Masculino , Pessoa de Meia-Idade , Adulto Jovem
19.
Skeletal Radiol ; 48(1): 137-141, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30006828

RESUMO

OBJECTIVES: The purposes of our study are to determine the quantitative elasticity values of normal common extensor tendon (CET) and to assess the interobserver variability of stiffness measurements using shear wave elastography (SWE). MATERIALS AND METHODS: A total of 60 CETs of 30 (15 female, 15 male, mean age 30.2 years) healthy volunteers without any symptoms of lateral epicondylitis were examined by two radiologists. Age, sex, height, weight, body mass index (BMI), and dominant hand of all participants were noted. The first observer performed B-mode and SWE imaging, and the second observer performed only SWE imaging. Tendon thickness and stiffness values in kPa were measured. RESULTS: The mean thickness of CETs was 3.57 ± 0.36 mm. The mean stiffness values of CETs for two observers were 45.28 ± 9.82 kPa and 45.80 ± 9.72 kPa respectively. Tendon thickness had a weak correlation with weight (r = 0.281, p = 0.03), and moderate correlation with stiffness values (r = 0.429, p < 0.001). The mean interobserver difference of CET stiffness measurements was -0.5% of the mean CET stiffness values. Range of measurement error, defined as 95% limits of agreement, was ±23.5%. There was no significant difference between absolute values of interobserver measurements (p = 0.741). CONCLUSION: Shear wave elastography is a reproducible imaging technique for the evaluation of CET elasticity and the standard stiffness values of normal CET can be used as reference data to differentiate normal from pathological tissues.


Assuntos
Braço/diagnóstico por imagem , Técnicas de Imagem por Elasticidade , Tendões/diagnóstico por imagem , Adulto , Feminino , Voluntários Saudáveis , Humanos , Masculino , Variações Dependentes do Observador , Valores de Referência
20.
Gene ; 687: 280-288, 2019 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-30468909

RESUMO

Fabry disease results from deficiency of the lysosomal enzyme alpha-galactosidase A. The families of 11 index cases were screened by enzyme and molecular assays. Further clinical and laboratory investigations were carried out in all cases. Including 33 new patients, a total of 28 females (Age 25,82 ±â€¯12,1 Range 8-46) and 16 males (Age 24,56 ±â€¯15,04 Range 2-48) were investigated. Ten different disease-causing variants were found two of them being novel. One patient had co-existing familial mediteranian fever, one had celiac disease and three had rheumatological disorders. Lipoprotein (a) levels were elevated in 17,6%, homocysteine in 22,2%, total and low density cholesterol in 12% and antithrombin 3 levels were elevated in 13,3%. One patient was found to be heterozygous for prothrombin p.G20210A disease-causing variant (5,8%) and two for factor V Leiden disease-causing variant (11,7%). Anticardiolipin IgM antibody was found to be positive in 11,7%. The patients with abnormal cranial imaging were also noticed to have additional risk factors for thrombosis. This study provides the largest data about Fabry patients from Turkey and implies that co-existing risk factors unrelated to Fabry Disease have significant association with the presence of clinical symptoms in females and might cause an early and severe clinical course in males.


Assuntos
Biomarcadores/metabolismo , Doença de Fabry/epidemiologia , Doença de Fabry/metabolismo , Variação Genética , alfa-Galactosidase/metabolismo , Adolescente , Adulto , Estudos de Casos e Controles , Criança , Pré-Escolar , Feminino , Seguimentos , Heterozigoto , Humanos , Masculino , Pessoa de Meia-Idade , Linhagem , Fenótipo , Prognóstico , Fatores de Risco , Turquia/epidemiologia , Adulto Jovem , alfa-Galactosidase/genética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA