1.
Ultrasound Med Biol ; 48(2): 346-357, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34763906

RESUMO

Local pressure differences estimated using vector flow imaging (VFI) and direct catheterization in seven carotid bifurcation phantoms were compared with simulated pressure fields. VFI correlated strongly with simulated peak pressure differences (r = 0.99, p < 0.00001), with an average overestimation of 12.3 Pa (28.6%). The range between the lowest and highest pressure difference of VFI underestimated simulations by 4.6 Pa (8.06%; r = 0.99, p < 0.0001). The catheter method exhibited no correlation (r = -0.09, p = 0.85). Ten repeated measurements on one phantom revealed a small standard deviation (SD) for VFI (SD = 8.4%, mean estimated SD = 11.5%), but not for the catheter method (SD = 785.6%). An in vivo peak systolic pressure difference of 97.9 Pa (estimated SD = 30%) was measured using VFI in one healthy individual. This study indicates that VFI pressure difference estimation is feasible in phantoms and in vivo and realistic estimates of the SD can be attained from the data.


Assuntos
Artérias Carótidas , Pescoço , Velocidade do Fluxo Sanguíneo , Artérias Carótidas/diagnóstico por imagem , Imagens de Fantasmas , Ultrassonografia
2.
Neurol Int ; 13(3): 269-278, 2021 Jun 23.
Artigo em Inglês | MEDLINE | ID: mdl-34201493

RESUMO

Volume flow estimation in the common carotid artery (CCA) can assess the absolute hemodynamic effect of a carotid stenosis. The aim of this study was to compare a commercial vector flow imaging (VFI) setup against the reference method magnetic resonance phase contrast angiography (MRA) for volume flow estimation in the CCA. Ten healthy volunteers were scanned with VFI and MRA over the CCA. VFI had an improved precision of 19.2% compared to MRA of 31.9% (p = 0.061). VFI estimated significantly lower volume flow than MRA (mean difference: 63.2 mL/min, p = 0.017), whilst the correlation between VFI and MRA was strong (R2 = 0.81, p < 0.0001). A Bland-Altman plot indicated a systematic bias. After bias correction, the percentage error was reduced from 41.0% to 25.2%. This study indicated that a VFI setup for volume flow estimation is precise and strongly correlated to MRA volume flow estimation, and after correcting for the systematic bias, VFI and MRA become interchangeable.

3.
Ultrasound Med Biol ; 46(9): 2493-2504, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32595057

RESUMO

Non-invasive assessment is preferred for monitoring arteriovenous dialysis fistulas (AVFs). Vector concentration assesses flow complexity, which may correlate with stenosis severity. We determined whether vector concentration could assess stenosis severity in dysfunctional AVFs. Vector concentration was estimated in four stenotic phantoms at different pulse repetition frequencies. Spectral Doppler peak velocity and vector concentration were measured in 12 patients with dysfunctional AVFs. Additionally, 5 patients underwent digital subtraction angiography (DSA). In phantoms, vector concentration exhibited an inverse relationship with stenosis severity and was less affected by aliasing in severe stenoses. In nine stenoses of 5 patients undergoing DSA, vector concentration correlated strongly with stenosis severity (first stenosis: r = -0.73, p = 0.04; other stenoses; r = -0.69, p = 0.02) and mid-stenotic diameter (first stenosis: r = 0.87, p = 0.006; other stenoses: r = 0.70, p = 0.02) as opposed to peak velocities (p > 0.05). Vector concentration is less affected by aliasing in severe stenoses and correlates with DSA in patients with dysfunctional AVF.


Assuntos
Derivação Arteriovenosa Cirúrgica , Constrição Patológica/diagnóstico por imagem , Diálise Renal , Humanos , Imagens de Fantasmas , Reologia , Índice de Gravidade de Doença , Ultrassonografia Doppler
4.
Artigo em Inglês | MEDLINE | ID: mdl-29993373

RESUMO

Echocardiography examination of the blood flow is currently either restricted to 1-D techniques in real-time or experimental offline 2-D methods. This paper presents an implementation of transverse oscillation for real-time 2-D vector flow imaging (VFI) on a commercial BK Ultrasound scanner. A large field-of-view (FOV) sequence for studying flow dynamics at 11 frames per second (fps) and a sequence for studying peak systolic velocities (PSVs) with a narrow FOV at 36 fps were validated. The VFI sequences were validated in a flow rig with continuous laminar parabolic flow and in a pulsating flow pump system before being tested in vivo, where measurements were obtained on two healthy volunteers. Mean PSV from 11 cycles was 155 cms-1 with a precision of ±9.0% for the pulsating flow pump. In vivo, PSV estimated in the ascending aorta was 135 cms-1 ± 16.9% for eight cardiac cycles. Furthermore, in vivo flow dynamics of the left ventricle and in the ascending aorta were visualized. In conclusion, angle independent 2-D VFI on a phased array has been implemented in real time, and it is capable of providing quantitative and qualitative flow evaluations of both the complex and fully transverse flow.


Assuntos
Velocidade do Fluxo Sanguíneo/fisiologia , Imageamento Tridimensional/métodos , Ultrassonografia/métodos , Adulto , Algoritmos , Aorta/diagnóstico por imagem , Desenho de Equipamento , Humanos , Masculino , Imagens de Fantasmas , Ultrassonografia/instrumentação
5.
Ultrasound Med Biol ; 44(8): 1751-1761, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29804906

RESUMO

Magnetic resonance phase contrast angiography (MRA) is the gold standard for blood flow evaluation. Spectral Doppler ultrasound (SDU) is the first clinical choice, although the method is angle dependent. Vector flow imaging (VFI) is an angle-independent ultrasound method. The aim of the study was to compare VFI- and SDU-estimated peak systolic velocities (PSV) of the common carotid artery (CCA) with PSV obtained by MRA. Furthermore, intra- and inter-observer agreement was determined. MRA estimates were significantly different from SDU estimates (left CCA: p < 0.001, right CCA: p < 0.001), but not from VFI estimates (left CCA: p = 0.28, right CCA: p = 0.18). VFI measured lower PSV in both CCAs compared with SDU (p < 0.001) with improved precision (VFI: left: 24%, right: 18%; SDU: left 38%, right: 23%). Intra- and inter-observer agreement was almost perfect for VFI and SDU (inter-observer correlation coefficient: VFI 0.88, SDU 0.91; intra-observer correlation coefficient: VFI 0.96, SDU 0.97). VFI is more accurate than SDU in evaluating PSV compared with MRA.


Assuntos
Artéria Carótida Primitiva/fisiologia , Angiografia por Ressonância Magnética/métodos , Ultrassonografia Doppler/métodos , Adulto , Velocidade do Fluxo Sanguíneo , Artéria Carótida Primitiva/diagnóstico por imagem , Feminino , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Valores de Referência
6.
Ultrasound Med Biol ; 44(8): 1727-1741, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29735315

RESUMO

The objective of the study described here was to investigate the accuracy and precision of a plane wave 2-D vector flow imaging (VFI) method in laminar and complex blood flow conditions in the healthy carotid artery. The approach was to study (i) the accuracy for complex flow by comparing the velocity field from a computational fluid dynamics (CFD) simulation to VFI estimates obtained from the scan of an anthropomorphic flow phantom and from an in vivo scan; (ii) the accuracy for laminar unidirectional flow in vivo by comparing peak systolic velocities from VFI with magnetic resonance angiography (MRA); (iii) the precision of VFI estimation in vivo at several evaluation points in the vessels. The carotid artery at the bifurcation was scanned using both fast plane wave ultrasound and MRA in 10 healthy volunteers. The MRA geometry acquired from one of the volunteers was used to fabricate an anthropomorphic flow phantom, which was also scanned using the fast plane wave sequence. The same geometry was used in a CFD simulation to calculate the velocity field. Results indicated that similar flow patterns and vortices were estimated with CFD and VFI in the phantom for the carotid bifurcation. The root-mean-square difference between CFD and VFI was within 0.12 m/s for velocity estimates in the common carotid artery and the internal branch. The root-mean-square difference was 0.17 m/s in the external branch. For the 10 volunteers, the mean difference between VFI and MRA was -0.17 m/s for peak systolic velocities of laminar flow in vivo. The precision in vivo was calculated as the mean standard deviation (SD) of estimates aligned to the heart cycle and was highest in the center of the common carotid artery (SD = 3.6% for velocity magnitudes and 4.5° for angles) and lowest in the external branch and for vortices (SD = 10.2% for velocity magnitudes and 39° for angles). The results indicate that plane wave VFI measures flow precisely and that estimates are in good agreement with a CFD simulation and MRA.


Assuntos
Artérias Carótidas/fisiologia , Ultrassonografia/métodos , Adulto , Velocidade do Fluxo Sanguíneo/fisiologia , Artérias Carótidas/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valores de Referência , Reprodutibilidade dos Testes
7.
Artigo em Inglês | MEDLINE | ID: mdl-29733275

RESUMO

A noninvasive method for estimating intravascular pressure changes using 2-D vector velocity is presented. The method was first validated on computational fluid dynamic (CFD) data and with catheter measurements on phantoms. Hereafter, the method was tested in vivo at the carotid bifurcation and at the aortic valve of two healthy volunteers. Ultrasound measurements were performed using the experimental scanner SARUS, in combination with an 8 MHz linear array transducer for experimental scans and a carotid scan, whereas a 3.5-MHz phased array probe was employed for a scan of an aortic valve. Measured 2-D fields of angle-independent vector velocities were obtained using synthetic aperture imaging. Pressure drops from simulated steady flow through six vessel geometries spanning different degrees of diameter narrowing, running from 20%-70%, showed relative biases from 0.35% to 12.06%, depending on the degree of constriction. Phantom measurements were performed on a vessel with the same geometry as the 70% constricted CFD model. The derived pressure drops were compared to pressure drops measured by a clinically used 4F catheter and to a finite-element model. The proposed method showed peak systolic pressure drops of -3 kPa ± 57 Pa, while the catheter and the simulation model showed -5.4 kPa ± 52 Pa and -2.9 kPa, respectively. An in vivo acquisition of 10 s was made at the carotid bifurcation. This produced eight cardiac cycles from where pressure gradients of -227 ± 15 Pa were found. Finally, the aortic valve measurement showed a peak pressure drop of -2.1 kPa over one cardiac cycle. In conclusion, pressure gradients from convective flow changes are detectable using 2-D vector velocity ultrasound.


Assuntos
Velocidade do Fluxo Sanguíneo/fisiologia , Determinação da Pressão Arterial/métodos , Ultrassonografia/métodos , Adulto , Pressão Sanguínea/fisiologia , Artérias Carótidas/diagnóstico por imagem , Artérias Carótidas/fisiologia , Estenose das Carótidas/diagnóstico por imagem , Estenose das Carótidas/fisiopatologia , Humanos , Masculino , Imagens de Fantasmas , Processamento de Sinais Assistido por Computador , Ultrassonografia/instrumentação , Dispositivos de Acesso Vascular
8.
Ultrason Imaging ; 39(1): 3-18, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26705136

RESUMO

Transverse oscillation (TO) is a real-time ultrasound vector flow method implemented on a commercial scanner. The TO setup was examined on a flowrig with constant and pulsatile flow. Subsequently, 25 patients undergoing cardiac bypass surgery were scanned intraoperatively with TO on the ascending aorta and compared to transesophageal echocardiography (TEE) and pulmonary artery catheter thermodilution (PACTD). On the flowrig, TO had a precision of 5.5%, 9.4% and 14.7%, a percentage error of 18.2%, 14.6% and 40.7%, and a mean bias of 0.4 cm/s, 36.8 ml/min and 32.4 ml/min for velocity and flow rate (constant and pulsatile) estimation. The correlation coefficients for all flowrig evaluations were 0.99 indicating systematic bias. After bias correction, the percentage error was reduced to 11.5%, 12.6% and 15.9% for velocity and flow rate (constant and pulsatile) estimation. In the in vivo setup, TO, TEE, and PACTD had a precision of 21.9%, 13.7%, and 12.0%. TO compared with TEE and PACTD had a mean bias of 12.6 cm/s and -0.08 l/min, and a percentage error of 23.4%, and 36.7%, respectively. The percentage error was reduced to 22.9% for the TEE comparison, but increased to 43.8% for the PACTD comparison, after correction for the systematic bias found in the flowrig. TO is a reliable and precise method for velocity and flow rate estimation on a flowrig. However, TO with the present setup, is not interchangeable with PACTD for cardiac volume flow estimation, but is a reliable and precise angle-independent ultrasound alternative for velocity estimation of cardiac flow.

9.
Ultrasonics ; 70: 136-46, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-27164045

RESUMO

A method for vector velocity volume flow estimation is presented, along with an investigation of its sources of error and correction of actual volume flow measurements. Volume flow errors are quantified theoretically by numerical modeling, through flow phantom measurements, and studied in vivo. This paper investigates errors from estimating volumetric flow using a commercial ultrasound scanner and the common assumptions made in the literature. The theoretical model shows, e.g. that volume flow is underestimated by 15%, when the scan plane is off-axis with the vessel center by 28% of the vessel radius. The error sources were also studied in vivo under realistic clinical conditions, and the theoretical results were applied for correcting the volume flow errors. Twenty dialysis patients with arteriovenous fistulas were scanned to obtain vector flow maps of fistulas. When fitting an ellipsis to cross-sectional scans of the fistulas, the major axis was on average 10.2mm, which is 8.6% larger than the minor axis. The ultrasound beam was on average 1.5mm from the vessel center, corresponding to 28% of the semi-major axis in an average fistula. Estimating volume flow with an elliptical, rather than circular, vessel area and correcting the ultrasound beam for being off-axis, gave a significant (p=0.008) reduction in error from 31.2% to 24.3%. The error is relative to the Ultrasound Dilution Technique, which is considered the gold standard for volume flow estimation for dialysis patients. The study shows the importance of correcting for volume flow errors, which are often made in clinical practice.


Assuntos
Derivação Arteriovenosa Cirúrgica , Velocidade do Fluxo Sanguíneo/fisiologia , Determinação do Volume Sanguíneo/métodos , Volume Sanguíneo/fisiologia , Aumento da Imagem/métodos , Ultrassonografia Doppler/métodos , Algoritmos , Artefatos , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
10.
Ultrasound Med Biol ; 40(11): 2707-14, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25282482

RESUMO

Volume flow in arteriovenous fistulas for hemodialysis was measured using the angle-independent ultrasound technique Vector Flow Imaging and compared with flow measurements using the ultrasound dilution technique during dialysis. Using an UltraView 800 ultrasound scanner (BK Medical, Herlev, Denmark) with a linear transducer, 20 arteriovenous fistulas were scanned directly on the most superficial part of the fistula just before dialysis. Vector Flow Imaging volume flow was estimated with two different approaches, using the maximum and the average flow velocities detected in the fistula. Flow was estimated to be 242 mL/min and 404 mL/min lower than the ultrasound dilution technique estimate, depending on the approach. The standard deviations of the two Vector Flow Imaging approaches were 175.9 mL/min and 164.8 mL/min compared with a standard deviation of 136.9 mL/min using the ultrasound dilution technique. The study supports that Vector Flow Imaging is applicable for volume flow measurements.


Assuntos
Braço/diagnóstico por imagem , Derivação Arteriovenosa Cirúrgica/métodos , Análise de Variância , Braço/irrigação sanguínea , Velocidade do Fluxo Sanguíneo , Humanos , Falência Renal Crônica/terapia , Diálise Renal/métodos , Insuficiência Renal/terapia , Reprodutibilidade dos Testes , Ultrassonografia