Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Am J Vet Res ; 81(10): 790-795, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32969729

RESUMO

OBJECTIVE: To use the small data approach of the Clinical and Laboratory Standards Institute (CLSI) to evaluate the transferability of reference intervals (RIs) for kinetic variables obtained with instrumented gait analysis (IGA) in dogs from an RI-originator laboratory to another laboratory that used the same data acquisition and analytic techniques for IGA in walking dogs. ANIMALS: 27 adult client-owned dogs without evidence of lameness. PROCEDURES: Dogs were individually walked at their preferred velocity on a pressure-sensing walkway for IGA at the Colorado State University Animal Gait Laboratory (CSU-AGL), and 6 valid trials were analyzed for each dog. The small data approach of the CLSI was then used to evaluate transferability of RIs previously established at the Purdue University Animal Gait Laboratory (PU-AGL). A linear model was used to establish weight-dependent RIs for peak vertical force (PVF). RESULTS: Results indicated that RIs of dynamic weight distribution (DWD), DWD symmetry index, DWD coefficient of variation, PVF symmetry index, and PVF coefficient of variation were transferable from PU-AGL to CSU-AGL, whereas the weight-dependent RIs for PVF were not. Regression slopes for PVF versus body weight were greater for all limbs in dogs tested at the CSU-AGL, compared with historic results for dogs tested at the PU-AGL. CONCLUSIONS AND CLINICAL RELEVANCE: Use of the small data approach method of the CLSI to validate transference of RIs for IGA kinetic variables in walking dogs was simple and efficient to perform and may help facilitate clinical and research collaborations on gait analysis.


Assuntos
Análise da Marcha , Caminhada , Animais , Fenômenos Biomecânicos , Cães , Marcha , Cinética
2.
JFMS Open Rep ; 5(2): 2055116919867178, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31452913

RESUMO

CASE SUMMARY: A 4-year-old neutered male cat was presented with a 2-month history of intermittent constipation that progressed to obstipation. Primary clinical findings included a large, multi lobulated mass in the caudodorsal abdomen, peripheral eosinophilia and hyperglobulinemia. Abdominal imaging revealed a multilobulated, cavitated mass in the sublumbar region. Exploratory celiotomy revealed multiple firm masses in the sublumbar retroperitoneal space causing ventral displacement and compression of the descending colon with extension of the masses into the pelvic canal. Histopathology was consistent with feline gastrointestinal eosinophilic sclerosing fibroplasia (FGESF). Aerobic culture was positive for Staphylococcus aureus. The cat was treated with prednisolone (2 mg/kg PO q24h), lactulose (0.5 g/kg PO q8h), amoxicillin/clavulanic acid (62.5 mg/cat PO q12h for 1 month) and fenbendazole (50 mg/kg PO q24h for 5 days). Six months postoperatively, the cat had no recurrence of clinical signs. Repeat evaluation and imaging at day 732 postoperatively revealed marked improvement of the abdominal mass, resolution of peripheral eosinophilia and no clinical signs with continued prednisolone therapy (0.5 mg/kg PO q24h). RELEVANCE AND NOVEL INFORMATION: This is a report of a primary extramural FGESF lesion, and the first description of characteristics of FGESF on CT. Previous evidence suggests that the most favorable outcomes require immunosuppressive therapy and complete surgical excision; however, this case demonstrates a favorable outcome with medical management alone.

3.
Am J Vet Res ; 79(3): 317-323, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29466049

RESUMO

OBJECTIVE To quantitatively measure the amount of pressure induced at the calcaneus and cranial tibial surface of dogs by use of 2 cast configurations. ANIMALS 13 client- or student-owned dogs. PROCEDURES Pressure sensors were placed over the calcaneus and cranial tibial surface. Dogs then were fitted with a fiberglass cast on a pelvic limb extending from the digits to the stifle joint (tall cast). Pressure induced over the calcaneus and proximal edge of the cast at the level of the cranial tibial surface was simultaneously recorded during ambulation. Subsequently, the cast was shortened to end immediately proximal to the calcaneus (short cast), and data acquisition was repeated. Pressure at the level of the calcaneus and cranial tibial surface for both cast configurations was compared by use of paired t tests. RESULTS The short cast created significantly greater peak pressure at the level of the calcaneus (mean ± SD, 0.2 ± 0.07 MPa), compared with peak pressure created by the tall cast (0.1 ± 0.06 MPa). Mean pressure at the proximal cranial edge of the cast was significantly greater for the short cast (0.2 ± 0.06 MPa) than for the tall cast (0.04 ± 0.03 MPa). CONCLUSIONS AND CLINICAL RELEVANCE A cast extended to the level of the proximal portion of the tibia caused less pressure at the level of the calcaneus and the proximal cranial edge of the cast. Reducing the amount of pressure at these locations may minimize the potential for pressure sores and other soft tissue injuries.


Assuntos
Moldes Cirúrgicos/veterinária , Cães , Tíbia , Animais , Ligamento Cruzado Anterior , Feminino , Masculino , Pressão , Rotação , Joelho de Quadrúpedes , Caminhada
4.
BMC Vet Res ; 13(1): 48, 2017 Feb 10.
Artigo em Inglês | MEDLINE | ID: mdl-28187763

RESUMO

BACKGROUND: Accelerometer-based activity monitoring is a promising new tool in veterinary medicine used to objectively assess activity levels in dogs. To date, it is unknown how device orientation, attachment method, and attachment of a leash to the collar holding an accelerometer affect canine activity data. It was our goal to evaluate whether attachment methods of accelerometers affect activity counts. Eight healthy, client-owned dogs were fitted with two identical neck collars to which two identical activity monitors were attached using six different methods of attachment. These methods of attachment evaluated the use of a protective case, positioning of the activity monitor and the tightness of attachment of the accelerometer. Lastly, the effect of leash attachment to the collar was evaluated. For trials where the effect of leash attachment to the collar was not being studied, the leash was attached to a harness. Activity data obtained from separate monitors within a given experiment were compared using Pearson correlation coefficients and across all experiments using the Kruskal-Wallis Test. RESULTS: There was excellent correlation and low variability between activity monitors on separate collars when the leash was attached to a harness, regardless of their relative positions. There was good correlation when activity monitors were placed on the same collar regardless of orientation. There were poor correlations between activity monitors in three experiments: when the leash was fastened to the collar that held an activity monitor, when one activity monitor was housed in the protective casing, and when one activity monitor was loosely zip-tied to the collar rather than threaded on using the provided metal loop. Follow-up, pair-wise comparisons identified the correlation associated with these three methods of attachment to be statistically different from the level of correlation when monitors were placed on separate collars. CONCLUSIONS: While accelerometer-based activity monitors are useful tools to objectively assess physical activity in dogs, care must be taken when choosing a method to attach the device. The attachment of the activity monitor to the collar should utilize a second, dedicated collar that is not used for leash attachment and the attachment method should remain consistent throughout a study period.


Assuntos
Acelerometria/veterinária , Cães/fisiologia , Monitorização Fisiológica/veterinária , Atividade Motora/fisiologia , Projetos de Pesquisa/normas , Animais , Monitorização Fisiológica/instrumentação , Monitorização Fisiológica/normas , Reprodutibilidade dos Testes
5.
Vet Comp Orthop Traumatol ; 29(4): 330-7, 2016 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-27432272

RESUMO

OBJECTIVES: To describe the use of hemiepiphysiodesis for the treatment of proximal tibial deformities in immature dogs and evaluate the effect on the mechanical medial proximal tibial angle (mMPTA). METHODS: Skeletally immature dogs with proximal tibial deformities from three institutions treated with hemiepiphysiodesis between March 2006 and January 2015 were included. All dogs were required to have an mMPTA outside the previously published reference range (93.3 ± 1.78°) preoperatively. Dogs were required to have radiographs or computed tomography performed preoperatively and at least eight weeks postoperatively. RESULTS: A total of 19 dogs (n = 31 limbs) fulfilled the inclusion criteria. The mean mMPTA was 102.5° ± 5.3° preoperatively and 92.4° ± 7.2° at the final re-evaluation. The mean difference in mMPTA was -10 ± 5.1° (range, -1 to -19°; p <0.001). Overcorrection was observed in 16 limbs and mMPTA remained above the reference range in nine limbs. Rebound growth was observed in eight limbs where implant removal was performed. CLINICAL SIGNIFICANCE: Hemiepiphysiodesis for the treatment of proximal tibial valgus is a technique that allows for reduction in mMPTA and should be considered as an early treatment for immature animals that are presented with proximal tibial deformities. Serial radiographs to monitor for overcorrection should be performed. Implant removal should be considered if overcorrection occurs, taking into consideration that rebound growth may be observed.


Assuntos
Cães/anormalidades , Cães/cirurgia , Procedimentos Ortopédicos/veterinária , Tíbia/anormalidades , Tíbia/cirurgia , Animais , Feminino , Masculino
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA