Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
J Sep Sci ; 43(13): 2657-2665, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32274855

RESUMO

Monitoring biological samples at trace levels of chemicals from anthropogenic actions such as pesticides, pharmaceuticals, and hormones has become a very important subject. This work describes a method for the determination of eight compounds of different chemical classes in human urine samples. Dispersive liquid-liquid microextraction based on magnetic ionic liquids was used as the sample preparation procedure. The main parameters of the method, such as sample dilution, type, and volume of disperser solvent, amount of magnetic ionic liquids, extraction time, and pH were optimized by univariate and multivariate procedures. Validation was performed using a urine sample of a male volunteer in order to obtain a calibration curve and the main analytical parameters of merit such as limits of detection and quantification. Values varied from 3.0 to 7.5 µg/L and from 10 to 25 µg/L, respectively. Satisfactory precisions of 21% for intraday (n = 3) and 16% for interday (n = 9) were achieved. Accuracy was evaluated by relative recovery assays using different urine samples and ranged from 75 to 130%. Robustness was assured by the Lenth method. The validated procedure was applied to five urine samples from different volunteers and the hormone estrone was found in one sample.


Assuntos
Diclofenaco/urina , Estrona/urina , Etinilestradiol/urina , Líquidos Iônicos/química , Microextração em Fase Líquida , Praguicidas/urina , Adulto , Calibragem , Cromatografia Líquida de Alta Pressão , Feminino , Humanos , Concentração de Íons de Hidrogênio , Fenômenos Magnéticos , Masculino , Adulto Jovem
2.
Anal Chim Acta ; 1069: 57-65, 2019 Sep 03.
Artigo em Inglês | MEDLINE | ID: mdl-31084741

RESUMO

In this study, a novel environmentally-friendly approach was developed to overcome certain limitations in the analysis of solid food samples. An experimental setup based on solid-phase microextraction apparatus coupled to a rotating disk device is proposed for the determination of polar and slightly-polar pesticides including carbofuran, molinate, atrazine, simazine and tebuconazole in rice samples. In this innovative procedure, a rice sample is inserted into the cavity of the rotating disk device which is then immersed in an aqueous solution followed by high-speed agitation. In this case, water is employed as a green solvent for leaching the analytes from the sample matrix. Simultaneously, a solid-phase microextraction fiber comprised of divinylbenzene/carboxen/polydimethylsiloxane (2 cm length and 50/30 µm film thickness) was immersed in the aqueous solution to extract the slightly polar analytes from the aqueous matrix with subsequent thermal desorption in the injector of a gas chromatograph-mass spectrometer instrument. The optimal extraction conditions were obtained using an extraction temperature of 80 °C for 40 min, with 125 mg of rice inserted in the rotating disk. Using the previously optimized extraction conditions, the analytical performance was satisfactory with correlation coefficients higher than 0.9881 for all analytes, limits of detection ranging from 0.46 to 5.9 ng g-1, limits of quantification from 1.5 to 19.7 ng g-1, relative recoveries from 76 to 109%, intra-day precision (n = 3) from 1.3 to 19%, and inter-day precision (n = 9) from 3.5 to 6.5%. The proposed method represents a promising alternative for the analysis of complex solid food samples using SPME, since the SPME fiber damage is substantially decreased when the contact with the solid matrix is avoided.


Assuntos
Contaminação de Alimentos/análise , Oryza/química , Praguicidas/análise , Microextração em Fase Sólida , Adsorção , Cromatografia Gasosa-Espectrometria de Massas , Solventes/química , Propriedades de Superfície , Água/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA