Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
J Anat ; 230(5): 619-630, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28127750

RESUMO

Human beings stand upright with the chain of balance beginning at the feet, progressing to the lower limbs (ankles, knees, hip joints, pelvis), each of the spinal segments, and then ending at the cranium to achieve horizontal gaze and balance using minimum muscle activity. The details of the alignment and balance of the chain, however, are not clearly understood, due to the lack of information regarding the three-dimensional (3D) orientation of all bony elements in relation to the gravity line (GL). We performed a clinical study to clarify the standing sagittal alignment of whole axial skeletons in reference to the GL using the EOS slot-scanning 3D X-ray imaging system with simultaneous force plate measurement in a healthy human population. The GL was defined as a vertical line drawn through the centre of vertical pressure measured by the force plate. The present study yielded a complete set of physiological alignment measurements of the standing axial skeleton from the database of 136 healthy subjects (a mean age of 39.7 years, 20-69 years; men: 40, women: 96). The mean offset of centre of the acoustic meati from the GL was 0.0 cm. The offset of the cervical and thoracic vertebrae was posterior to the GL with the apex of thoracic kyphosis at T7, 5.0 cm posterior to the GL. The sagittal alignment changed to lordosis at the level of L2. The apex of the lumbar lordosis was L4, 0.6 cm anterior to the GL, and the centre of the base of the sacrum (CBS) was just posterior to the GL. The hip axis (HA) was 1.4 cm anterior to the GL. The knee joint was 2.4 cm posterior and the ankle joint was 4.8 cm posterior to the GL. L4-, L5- and the CBS-offset in subjects in the age decades of 40s, 50s and 60s were significantly posterior to those of subjects in their 20s. The L5- and CBS-offset in subjects in their 50s and 60s were also significantly posterior to those in subjects in their 30s. HA was never posterior to the GL. In the global alignment, there was a positive correlation between offset of C7 vertebra from the sagittal vertical axis (a vertical line drawn through the posterior superior corner of the sacrum in the sagittal plane) and age, but no correlation was detected between the centre of the acoustic meati-GL offset and age. Cervical lordosis (CL), pelvic tilt (PT), pelvic incidence, hip extension, knee flexion and ankle dorsiflexion increased significantly with age. Our results revealed that aging induces trunk stooping, but the global alignment is compensated for by an increase in the CL, PT and knee flexion, with the main function of CL and PT to maintain a horizontal gaze in a healthy population.


Assuntos
Gravitação , Equilíbrio Postural , Postura , Esqueleto/diagnóstico por imagem , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Equilíbrio Postural/fisiologia , Postura/fisiologia , Radiografia/métodos , Adulto Jovem
2.
Eur Spine J ; 25(11): 3675-3686, 2016 11.
Artigo em Inglês | MEDLINE | ID: mdl-27432430

RESUMO

PURPOSE: To elucidate the normative values of whole body sagittal alignment and balance of a healthy population in the standing position; and to clarify the relationship among the alignment, balance, health-related quality of life (HRQOL), and age. METHODS: Healthy Japanese adult volunteers [n = 126, mean age 39.4 years (20-69), M/F = 30/96] with no history of spinal disease were enrolled in a cross-sectional cohort study. The Oswestry Disability Index (ODI) questionnaire was administered and subjects were scanned from the center of the acoustic meati (CAM) to the feet while standing on a force plate to determine the gravity line (GL), and the distance between CAM and GL (CAM-GL) was measured in the sagittal plane. Standard X-ray parameters were measured from the head to the lower extremities. ODI was compared among age groups stratified by decade. Correlations were investigated by simple linear regression analysis. Ideal lumbar lordosis was investigated using the least squares method. RESULTS: The present study yielded normative values for whole standing sagittal alignment including head and lower extremities in a cohort of 126 healthy adult volunteers, comparable to previous reports and thus a formula for ideal lumbar lordosis was deduced: LL = 32.9 + 0.60 × PI - 0.23 × age. There was a tendency of positive correlation between McGregor slope, thoracic kyphosis, PT, and age. SVA, T1 pelvic angle, sacrofemoral angle, knee flexion angle, and ankle flexion angle, but not CAM-GL, increased with age, suggesting that the spinopelvic alignment changes with age, but standing whole body alignment is compensated for to preserve a horizontal gaze. ODI tended to increase from the 40s in the domain of pain intensity, personal care, traveling, and total score. ODI weakly, but significantly positively correlated with age and PI-LL. CONCLUSION: Whole body standing alignment even in healthy subjects gradually deteriorates with age, but is compensated to preserve a horizontal gaze. HRQOL is also affected by aging and spinopelvic malalignment.


Assuntos
Ossos Pélvicos/anatomia & histologia , Postura , Qualidade de Vida , Coluna Vertebral/anatomia & histologia , Adulto , Fatores Etários , Idoso , Estudos Transversais , Feminino , Indicadores Básicos de Saúde , Voluntários Saudáveis , Humanos , Extremidade Inferior/anatomia & histologia , Extremidade Inferior/diagnóstico por imagem , Extremidade Inferior/fisiologia , Masculino , Pessoa de Meia-Idade , Ossos Pélvicos/diagnóstico por imagem , Ossos Pélvicos/fisiologia , Estudos Prospectivos , Radiografia , Valores de Referência , Análise de Regressão , Coluna Vertebral/diagnóstico por imagem , Coluna Vertebral/fisiologia , Adulto Jovem
3.
Clin Spine Surg ; 29(5): 212-6, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-22960419

RESUMO

STUDY DESIGN: A study using intraoperative sonography (IOS) was conducted for evaluating neural mobility in anterior cervical decompression surgery. OBJECTIVES: To analyze decompression status and mobility of the spinal cord and the nerve root during anterior cervical decompression and to clarify its relevance to the postoperative neurological recovery. SUMMARY OF BACKGROUND DATA: Several papers introduced the usefulness of IOS assessments; however, there have been no reports systematically evaluating the neural mobility in anterior cervical decompression surgery. METHODS: Eighty-four consecutive patients with compressive myelopathy who underwent anterior cervical decompression procedures were studied. The decompression status of the spinal cord was evaluated with IOS and classified into 3 grades according to the restoration pattern of the space ventral to the cord. Pulsatile motion of the spinal cord in cranio-caudal direction was named "sliding pulsation" and graded into 3 groups. The nerve root pulsation was also assessed using the IOS short-axis views. This study analyzed whether those neural mobility in anterior cervical decompression surgery had relevance to postoperative neurological recovery, which was assessed by the Japan Orthopaedic Association score. RESULTS: The mean recovery rate of the Japan Orthopaedic Association score was 59.1% in total. According to the decompression status in IOS, 67 patients who acquired space ventral to the spinal cord indicated 64.3% of the recovery rate which was significantly higher than 36.6% of the other patients on an average. As to the sliding pulsation of the cord, 10 patients who failed to show this particular motion indicated significantly lower recovery rate as 36.9%. In addition, 6 patients who did not exhibit nerve root pulsation indicated just 29.3% of recovery rate, and 4 of them failed to show the cord sliding motion. CONCLUSIONS: Sonographic evaluation during anterior cervical decompression surgery provided very useful information of neural decompression status that had significant correlation with postoperative neurological recovery.


Assuntos
Vértebras Cervicais/cirurgia , Descompressão Cirúrgica/métodos , Monitorização Neurofisiológica Intraoperatória/métodos , Recuperação de Função Fisiológica/fisiologia , Compressão da Medula Espinal/cirurgia , Ultrassonografia/métodos , Adulto , Idoso , Vértebras Cervicais/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Intraoperatória , Índice de Gravidade de Doença , Adulto Jovem
4.
Spine (Phila Pa 1976) ; 39(26): 2127-35, 2014 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-25503940

RESUMO

STUDY DESIGN: A clinicobiomechanical study. OBJECTIVE: To clarify the clinicobiomechanical characteristics of a segment with lumbar degenerative spondylolisthesis (LDS) using an original intraoperative measurement system. SUMMARY OF BACKGROUND DATA: Although radiographical evaluation of LDS is extensively performed, the diagnosis of segmental instability remains controversial. The intraoperative measurement system used in this study is the first clinically available system that performs cyclic flexion-extension displacement of the segment with all ligamentous structures intact and can determine both the stiffness (N/mm) and neutral zone (NZ, [mm/N]). METHODS: Forty-eight patients with LDS (males/females = 19/29, 68.5 yr; group D) were compared with 48 patients with lumbar spinal stenosis without LDS (males/females = 33/15, 64.8 yr, group N) in terms of symptoms, radiological, and biomechanical results. Instability was defined as a segment with NZ more than 2 mm. Symptoms (36-Item Short Form Health Survey), radiographical findings (radiographs, magnetic resonance images, computed tomographic scans), stiffness, NZ, and frequency of instability were also compared. Risk factors for instability were analyzed by multivariate logistic regression with a forward stepwise procedure. RESULTS: None of the physical function categories or radiological findings of 36-Item Short Form Health Survey and low back pain (visual analogue scale) differed significantly between the groups. Although NZ was significantly greater in group D (1.97) than in group N (1.73) (P < 0.05), the frequency of instability did not differ significantly between groups. Facet opening (odds ratio, 11.0; P < 0.01) and facet type (odds ratio, 6.0; P < 0.05) were significant risk factors for instability. CONCLUSION: Neither the symptoms nor the frequency of instability differed significantly between groups. The radiological findings of spondylolisthesis did not indicate instability, but facet opening and sagittally oriented facets were indicative of instability. The results of this study demonstrated that LDS is not always unstable in the measurement setting, suggesting that the instability of LDS can stabilize spontaneously during the natural course. LEVEL OF EVIDENCE: N/A.


Assuntos
Instabilidade Articular/fisiopatologia , Dor Lombar/fisiopatologia , Vértebras Lombares/fisiopatologia , Estenose Espinal/fisiopatologia , Espondilolistese/fisiopatologia , Idoso , Fenômenos Biomecânicos/fisiologia , Feminino , Humanos , Instabilidade Articular/cirurgia , Dor Lombar/cirurgia , Vértebras Lombares/cirurgia , Masculino , Pessoa de Meia-Idade , Estenose Espinal/cirurgia , Espondilolistese/cirurgia , Resultado do Tratamento
5.
Analyst ; 139(18): 4654-60, 2014 Sep 21.
Artigo em Inglês | MEDLINE | ID: mdl-25050480

RESUMO

An acetylcholinesterase-immobilized sensor unit was successfully prepared by encapsulating the enzyme within hybrid mesoporous silica membranes (F127-MST). Through a novel combination with tetracyanoquinodimethane, both acetylcholine and organophosphorus pesticides were successfully detected with high sensitivity. Furthermore, we manufactured the working prototype of an enzyme sensor with this sensor unit for detecting dichlorvos, aldicarb and parathion. At present, the detection limit in this working prototype either equaled or surpassed that of others. Also, we have the advantage of increased stability of the enzyme against the outer environment by encapsulation of the enzymes into a silica nanospace. Consequently, acetylcholinesterase immobilized in F127-MST is a practical sensor with high sensitivity, reusability, and storage stability.


Assuntos
Acetilcolina/análise , Acetilcolinesterase/metabolismo , Técnicas Biossensoriais/instrumentação , Membranas Artificiais , Compostos Organofosforados/análise , Praguicidas/análise , Dióxido de Silício/química , Acetilcolina/metabolismo , Animais , Técnicas Eletroquímicas/instrumentação , Electrophorus , Enzimas Imobilizadas/metabolismo , Desenho de Equipamento , Limite de Detecção , Compostos Organofosforados/metabolismo , Praguicidas/metabolismo , Porosidade
6.
Anal Bioanal Chem ; 405(1): 297-305, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23096941

RESUMO

A disposable amperometric biosensor for ketone 3-ß-hydroxybutyrate (3HB) has been developed successfully. The sensor is based on a screen-printed carbon electrode containing Meldola's Blue (MB) and sensing components containing nicotinamide adenine dinucleotide (NAD(+)) and 3-ß-hydroxybutyrate dehydrogenase (3HBDH) immobilized in mesoporous silica (FSM8.0) using an aqueous photo-cross-linkable polymer matrix of polyvinyl alcohol (O-391), and it requires only a small sample volume of 10 µL for the measurement. The behavior of a resulting biosensor, i.e., 3HBDH-FSM8.0/NAD(+)/MB-SPCE, was examined in terms of NAD(+) concentration for construction, pH, applied potential, operational range, selectivity, and storage stability. The sensor showed an optimum response at a pH of 7.6 and at an applied potential of -50 mV. The determination range and the response time for 3HB were from 30 µM to 8 mM and approximately 30 s, respectively. In addition, the sensor was quite stable and maintained >90% of its initial response after being stored for over 6 months. This result implies that our method provides a novel biosensor for ketone 3-ß-hydroxybutyrate which is easy-to-use, cost-effective, and has good reproducibility, which are vital for commercial purposes.


Assuntos
Ácido 3-Hidroxibutírico/química , Técnicas Biossensoriais , Hidroxibutirato Desidrogenase/química , Cetonas/química , Dióxido de Silício/química , Calibragem , Carbono/química , Relação Dose-Resposta a Droga , Eletroquímica/métodos , Eletrodos , Humanos , Concentração de Íons de Hidrogênio , Modelos Químicos , Conformação Molecular , Polímeros/química , Pós , Silício/química
7.
Anal Chim Acta ; 714: 114-20, 2012 Feb 10.
Artigo em Inglês | MEDLINE | ID: mdl-22244144

RESUMO

A novel amperometric biosensor for the measurement of L-lactate has been developed. The device comprises a screen-printed carbon electrode containing cobalt phthalocyanine (CoPC-SPCE), coated with lactate oxidase (LOD) that is immobilized in mesoporous silica (FSM8.0) using a polymer matrix of denatured polyvinyl alcohol; a Nafion layer on the electrode surface acts as a barrier to interferents. The sampling unit attached to the SPCE requires only a small sample volume of 100 µL for each measurement. The measurement of l-lactate is based on the signal produced by hydrogen peroxide, the product of the enzymatic reaction. The behavior of the biosensor, LOD-FSM8.0/Naf/CoPC-SPCE, was examined in terms of pH, applied potential, sensitivity and operational range, selectivity, and storage stability. The sensor showed an optimum response at a pH of 7.4 and an applied potential of +450 mV. The determination range and the response time for L-lactate were 18.3 µM to 1.5 mM and approximately 90s, respectively. In addition, the sensor exhibited high selectivity for L-lactate and was quite stable in storage, showing no noticeable change in its initial response after being stored for over 9 months. These results indicate that our method provides a simple, cost-effective, high-performance biosensor for l-lactate.


Assuntos
Técnicas Biossensoriais/instrumentação , Enzimas Imobilizadas/química , Indóis/química , Ácido Láctico/análise , Oxigenases de Função Mista/química , Compostos Organometálicos/química , Carbono , Eletrodos , Peróxido de Hidrogênio/química , Concentração de Íons de Hidrogênio , Álcool de Polivinil/química , Dióxido de Silício/química
9.
Talanta ; 78(1): 217-20, 2009 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-19174228

RESUMO

Choline sensor is successfully prepared by using immobilized enzyme, i.e., choline oxidase (ChOx) within a hybrid mesoporous membrane with 12 nm pore diameter (F127M). The measurement was based on the detection of hydrogen peroxide, which is the co-product of the enzymatic choline oxidation. The determination range and the response time are 5.0-800 microM and approximately 2 min, respectively. The sensor is very stable compared to the native enzyme sensor and 85% of the initial response was maintained even after storage for 80 days. These results indicate that ChOx is successfully immobilized and well stabilized, and at the same time, enzyme reaction proceeds efficiently. Such ability of hybrid mesoporous membrane F127M suggests great promise for effective immobilization of enzyme useful for electrochemical biosensors.


Assuntos
Oxirredutases do Álcool/metabolismo , Técnicas Biossensoriais/métodos , Colina/análise , Enzimas Imobilizadas/metabolismo , Eletroquímica/métodos , Peróxido de Hidrogênio/análise , Membranas Artificiais , Porosidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA