Phys Med ; 80: 119-124, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33171381

RESUMO

PURPOSE: The aim of this work was to evaluate the dosimetric impact of high-resolution thorax CT during COVID-19 outbreak in the University Hospital of Parma. In two months we have performed a huge number of thorax CT scans collecting effective and equivalent organ doses and evaluating also the lifetime attributable risk (LAR) of lung and other major cancers. MATERIALS AND METHOD: From February 24th to April 28th, 3224 high-resolution thorax CT were acquired. For all patients we have examined the volumetric computed tomography dose index (CTDIvol), the dose length product (DLP), the size-specific dose estimate (SSDE) and effective dose (E103) using a dose tracking software (Radimetrics Bayer HealthCare). From the equivalent dose to organs for each patient, LAR for lung and major cancers were estimated following the method proposed in BEIR VII which considers age and sex differences. RESULTS: Study population included 3224 patients, 1843 male and 1381 female, with an average age of 67 years. The average CTDIvol, SSDE and DLP, and E103 were 6.8 mGy, 8.7 mGy, 239 mGy·cm and 4.4 mSv respectively. The average LAR of all solid cancers was 2.1 cases per 10,000 patients, while the average LAR of leukemia was 0.2 cases per 10,000 patients. For both male and female the organ with a major cancer risk was lung. CONCLUSIONS: Despite the impressive increment in thoracic CT examinations due to COVID-19 outbreak, the high resolution low dose protocol used in our hospital guaranteed low doses and very low risk estimation in terms of LAR.


Assuntos
COVID-19/epidemiologia , Neoplasias Induzidas por Radiação/etiologia , Radiometria/métodos , Tórax/diagnóstico por imagem , Tomografia Computadorizada por Raios X/efeitos adversos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Surtos de Doenças , Feminino , Humanos , Pulmão/efeitos da radiação , Masculino , Pessoa de Meia-Idade , Modelos Estatísticos , Doses de Radiação , Medição de Risco , Fatores Sexuais , Software
2.
Radiat Prot Dosimetry ; 189(2): 224-233, 2020 Jul 13.
Artigo em Inglês | MEDLINE | ID: mdl-32161966

RESUMO

We investigated the performances of two computed tomography (CT) systems produced by the same manufacturers (Somatom Flash and Edge Siemens) with different detector technologies (Ultrafast Ceramic and Stellar) and different generation of iterative reconstruction (IR) algorithms (SAFIRE and ADMIRE). A homemade phantom was scanned and the images were reconstructed with filtered back-projection (FBP) and IR algorithms. In terms of image quality, the performances of the systems were checked using the low-contrast detectability, evaluated by a Channelized Hotelling Observer (CHO), and the noise power spectrum (NPS). The analysis with CHO showed the best performance of Edge respect to Flash system for both FBP and IR algorithms. This better behavior, which reaches 20%, has been ascribed to the Stellar detector. From the NPS analysis, the noise reduction due to Stellar detector was 57%, moreover ADMIRE algorithm preserves a more traditional CT image texture appearance versus SAFIRE due to a lower NPS peak shift.


Assuntos
Algoritmos , Tomografia Computadorizada por Raios X , Processamento de Imagem Assistida por Computador , Imagens de Fantasmas , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador , Tomógrafos Computadorizados
3.
Biomed Phys Eng Express ; 6(2): 025008, 2020 02 18.
Artigo em Inglês | MEDLINE | ID: mdl-33438634

RESUMO

The goal of this paper was the comparison of radiation dose and imaging quality before and after the Clarity IQ technology installation in a Philips AlluraXper FD20/20 angiography system using a Channelized Hotelling Observer model (CHO). The core characteristics of the Allura Clarity IQ technology are its real-time noise reduction algorithms (NRT) combined with state-of-the-art hardware; this technology allows to implement acquisition protocols able to significantly reduce patient entrance dose. To measure the system performances in terms of image quality we used a contrast detail phantom in a clinical scatter condition. A Leeds TO10 phantom has been imaged between two 10 cm thick homogeneous solid water slabs. Fluoroscopy images were acquired using a cerebral protocol at 3 dose levels (low, medium and high) with a field- of view (FOV) of 31 cm. Cineangiography images were acquired using a cerebral protocol at 2 fps. Thus, 4 acquisitions were obtained for the conventional technology and 4 acquisitions were taken after the Clarity IQ upgrade, for a total of 8 different image sets. A validated 40 Gabor channels CHO with an internal noise model compared the image sets. Human observers' studies were carried out to tune the internal noise parameter. We showed that the CHO did not detect any significant difference between any of the image sets acquired using the two technologies. Consequently, this x-ray imaging technology provides a non-inferior image quality with an average patient dose reduction of 57% and 28% respectively in cineangiography and fluoroscopy. The Clarity IQ installation has certainly allowed a considerable improvement in patient and staff safety, while maintaining the same image quality.


Assuntos
Algoritmos , Angiografia/normas , Processamento de Imagem Assistida por Computador/normas , Variações Dependentes do Observador , Imagens de Fantasmas , Controle de Qualidade , Tomografia Computadorizada por Raios X/métodos , Cineangiografia/métodos , Fluoroscopia/métodos , Humanos , Doses de Radiação
4.
Radiat Prot Dosimetry ; 181(3): 277-289, 2018 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-29462366

RESUMO

The aim of this article was to characterise the performance of four different digital breast tomosynthesis (DBT) systems in terms of dose and image quality parameters. One of them, GE Pristina, has never been tested before. Average glandular doses were measured both in DBT and 2D full field digital mammography mode. Several phantoms were employed to perform signal difference to noise ratio, slice sensitivity profile, slice to slice incrementation, chest wall offset, z-axis geometry, artefact spread function, low contrast detectability, contrast detail evaluations, image uniformity and in-plane MTF in chest wall-nipple and in tube-travel directions. There are many differences in DBT systems explored: the angular range, detector type, reconstruction algorithms, and the presence or not of the grid. Even if it is not simple to calculate a global figure of merit, the analysis of all the collected data can be useful in a contest of a quality assurance program to define a set of values that could be used as benchmarks.


Assuntos
Mama/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/normas , Mamografia/instrumentação , Mamografia/normas , Algoritmos , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Mamografia/métodos , Imagens de Fantasmas , Intensificação de Imagem Radiográfica , Razão Sinal-Ruído
5.
Radiat Prot Dosimetry ; 175(1): 38-45, 2017 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-27614299

RESUMO

Dose optimization in radiological examinations is a mandatory issue: in this study local Diagnostic Reference Levels (lDRLs) for Clinical Mammography (MG), Computed Tomography (CT) and Interventional Cardiac Procedures (ICP) performed in our Radiology Department were established. Using a dose tracking software, we have collected Average Glandular Dose (AGD) for two clinical mammographic units; CTDIvol, Size-Specific Dose Estimate (SSDE), Dose Length Product (DLP) and total DLP (DLPtot) for five CT scanners; Fluoro Time, Fluoro Dose Area Product (DAP) and total DAP (DAPtot) for two angiographic systems. Data have been compared with Italian Regulation and with the recent literature. The 75th percentiles of the different dosimetric indices have been calculated. Automated methods of radiation dose data collection allow a fast and detailed analysis of a great amount of data and an easy determination of lDRLs for different radiological procedures.


Assuntos
Angiografia , Software , Tomografia Computadorizada por Raios X , Humanos , Doses de Radiação , Radiometria
6.
Phys Med ; 28(2): 161-5, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21497530

RESUMO

Although iterative reconstruction is widely applied in SPECT/PET, its introduction in clinical CT is quite recent, in the past the demand for extensive computer power and long image reconstruction times have stopped the diffusion of this technique. Recently Iterative Reconstruction in Image Space (IRIS) has been introduced on Siemens top CT scanners. This recon method works on image data area, reducing the time-consuming loops on raw data and noise removal is obtained in subsequent iterative steps with a smoothing process. We evaluated image noise, low contrast resolution, CT number linearity and accuracy, transverse and z-axis spatial resolution using some dedicated phantoms in single, dual source and cardiac mode. We reconstructed images with a traditional filtered back-projection algorithm and with IRIS. The iterative procedure preserves spatial resolution, CT number accuracy and linearity moreover decreases image noise. These preliminary results support the idea that dose reduction with preserved image quality is possible with IRIS, even if studies on patients are necessary to confirm these data.


Assuntos
Processamento de Imagem Assistida por Computador/instrumentação , Imagens de Fantasmas , Tomografia Computadorizada por Raios X/instrumentação , Modelos Lineares , Água
7.
J Exp Clin Cancer Res ; 26(2): 235-9, 2007 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-17725104

RESUMO

The objective of our study was to apply a quantitative analysis to the dynamic contrast enhanced MR imaging of the breast. Automated criteria increase the objectivity and reproducibility of the diagnostic interpretation of the imaging for differentiating benign and malignant lesions. The validation of this applied method was evaluated by analysing the time- signal intensity curves and the performance of the extracted enhancement parameters. The performance of some extracted parameters was evaluated by ROC (Receiver Operating Characteristic) analysis. These parameters were found to be particularly accurate in differentiating lesions.


Assuntos
Neoplasias da Mama/diagnóstico , Meios de Contraste/administração & dosagem , Gadolínio DTPA , Imageamento por Ressonância Magnética/métodos , Mama/patologia , Neoplasias da Mama/patologia , Feminino , Gadolínio DTPA/administração & dosagem , Humanos , Software
8.
J Exp Clin Cancer Res ; 25(1): 121-7, 2006 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-16761628

RESUMO

Quality control in MRI includes acceptance tests on the installation of a new scanner and tests representative of the system's performance during clinical practice. The first tests are time consuming and carried out to evaluate the agreement of the system with the prescribed procurement specifications. The second tests identify the equipment malfunction requiring maintenance are not time consuming and are suited to a busy clinical scanner. The paper evaluates the feasibility of the AAPM protocols (1,2) and proposes procedures and practical tools to achieve this purpose. The MRI images, captured from the scanner and transferred in DICOM (Digital Imaging and Communications in Medicine) format by a local network, are analyzed by computerized worksheets and commercial software.


Assuntos
Diagnóstico por Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Calibragem , Humanos , Processamento de Imagem Assistida por Computador/métodos , Magnetismo , Modelos Estatísticos , Imagens de Fantasmas , Controle de Qualidade , Sistemas de Informação em Radiologia , Software