Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Indian J Otolaryngol Head Neck Surg ; 76(2): 1747-1754, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38566686

RESUMO

SNHL in children is an important issue. Cochlear implant is a highly technological device that is surgically inserted in the cochlea to solve this issue. To evaluate types of anomalies of the inner ear in children with sensorineural hearing loss in a tertiary care hospital and confirm that the routine MRI, MR cisternography and HRCT provides the surgeon with the imaging finding and criteria of patients candidates for CI. Patients and method: 600 patients with SNHL underwent HRCT and MRI. CT examinations were normal in 457 patients (76.2%) and 143 patients (23.8%) with inner ear anomalies. MRI examinations were normal in 440 patients (73.3%) and had inner ear anomalies in 160 patients (26.7%). 3D bFFE and 3D DRIVE was summarized. The 3D bFFE sequence was statistically significantly better than the 3D DRIVE for the demonstration of the cochlear vestibule. Superior, inferior vestibular nerves and facial nerves while 3D DRIVE is superior to 3D bFFE in the visualization of the semicircular canals. HRCT and MRI provide accurate anatomical delineation of complex inner ear structures and 3D improves pre-implant evaluation.

2.
Eur J Radiol Open ; 4: 27-39, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28377947

RESUMO

OBJECTIVE: To evaluate the accuracy and sensitivity of diffusion-weighted magnetic resonance imaging with ADC value combined with MDCT in evaluating recurrent cholesteatoma. PATIENTS: Thirty patients (20 females and 10 males), their age ranged from 10 to 40years, had undergone a tympanomastoid surgery for a cholesteatoma of the middle ear underwent MDCT and MR DWI examination before second- or third-look surgery from May 2015 to October 2016. RESULTS: CT showed partial opacification of the tympanomastoid cavity in 10 ears and complete opacification in 21 ears. CT detects 10 cases out of 20 cases of recurrent cholesteatoma with sensitivity 47.6%, specificity 100%, and NPP 47.6%. DWI depicted 21 out of 20 cases proved cholesteatoma patients (sensitivity 100%, specificity 90%, PPV 95.2% and P value is 0.001). All MRI of patients without cholesteatoma were correctly interpreted as showing negative findings for cholesteatoma (specificity = 100%). The ADC of cholesteatoma group (21 ears) were ranged from 553 to 759 × 10-3 mm2/s and the ADCs of non cholesteatoma group (10 ears) was ranged from 1495.8 to 1766.8 × 10-3 mm2/s. Cut off value of cholesteatoma is ≤759 × 10-3 mm2/s. CONCLUSION: MR DWI with ADC combined with MDCT has high sensitivity, specificity, accuracy in detecting recurrent cholesteatoma.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA