Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Int J Cancer ; 2024 Jul 18.
Artigo em Inglês | MEDLINE | ID: mdl-39023303

RESUMO

The purpose of this study was to determine if dual-energy CT (DECT) vital iodine tumor burden (ViTB), a direct assessment of tumor vascularity, allows reliable response assessment in patients with GIST compared to established CT criteria such as RECIST1.1 and modified Choi (mChoi). From 03/2014 to 12/2019, 138 patients (64 years [32-94 years]) with biopsy proven GIST were entered in this prospective, multi-center trial. All patients were treated with tyrosine kinase inhibitors (TKI) and underwent pre-treatment and follow-up DECT examinations for a minimum of 24 months. Response assessment was performed according to RECIST1.1, mChoi, vascular tumor burden (VTB) and DECT ViTB. A change in therapy management could be because of imaging (RECIST1.1 or mChoi) and/or clinical progression. The DECT ViTB criteria had the highest discrimination ability for progression-free survival (PFS) of all criteria in both first line and second line and thereafter treatment, and was significantly superior to RECIST1.1 and mChoi (p < .034). Both, the mChoi and DECT ViTB criteria demonstrated a significantly early median time-to-progression (both delta 2.5 months; both p < .036). Multivariable analysis revealed 6 variables associated with shorter overall survival: secondary mutation (HR = 4.62), polymetastatic disease (HR = 3.02), metastatic second line and thereafter treatment (HR = 2.33), shorter PFS determined by the DECT ViTB criteria (HR = 1.72), multiple organ metastases (HR = 1.51) and lower age (HR = 1.04). DECT ViTB is a reliable response criteria and provides additional value for assessing TKI treatment in GIST patients. A significant superior response discrimination ability for median PFS was observed, including non-responders at first follow-up and patients developing resistance while on therapy.

2.
Bioengineering (Basel) ; 11(7)2024 Jul 12.
Artigo em Inglês | MEDLINE | ID: mdl-39061790

RESUMO

Intrinsic cerebrospinal fluid (CSF) dynamics in the brain have been extensively studied, particularly the egress sites of tagged intrinsic CSF in the meninges. Although spinal CSF recirculates within the central nervous system (CNS), we hypothesized that CSF outflows from the lumbar spinal canal. We aimed to visualize and semi-quantify the outflow using non-contrast MRI techniques. We utilized a 3 Tesla clinical MRI with a 16-channel spine coil, employing time-spatial labeling inversion (Time-SLIP) with tag-on and tag-off acquisitions, T2-weighted coronal 2D fluid-attenuated inversion recovery (FLAIR) and T2-weighted coronal 3D centric ky-kz single-shot FSE (cSSFSE). Images were acquired using time-spatial labeling inversion pulse (Time-SLIP) with tag-on and tag-off acquisitions with varying TI periods. Ten healthy volunteers with no known spinal diseases participated. Variations in tagged CSF outflow were observed across different thoracolumbar nerve root segments in all participants. We quantified CSF outflow at all lumbar levels and the psoas region. There was no significant difference among the ROIs for signal intensity. The tagged CSF outflow from the spinal canal is small but demonstrates egress to surrounding tissues. This finding may pave the way for exploring intrathecal drug delivery, understanding of CSF-related pathologies and its potential as a biomarker for peripheral neuropathy and radiculopathy.

3.
Radiol Case Rep ; 19(8): 3483-3487, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38872742

RESUMO

We present a case of prophylactic endovascular embolization in a 51-year-old man with necrotizing pancreatitis (NP) before undergoing endoscopic necrosectomy (EN). Contrast-enhanced CT imaging revealed the presence of a walled-off necrosis (WON) surrounding the pancreas, with the splenic artery coursing through the cavity. The splenic artery was embolized using n-butyl-2-cyanoacrylate (NBCA) and coils to mitigate the risk of massive bleeding in EN. A newly developed polytetrafluoroethylene (PTFE)-coated microcatheter was used to inject NBCA, enabling embolization of a long segment of the splenic artery without adhering to the vessel wall. Coils were placed distal and proximal to the embolized segment to optimize control. Over 5 sessions of EN, no massive bleeding was encountered. This report demonstrates the benefits of utilizing PTFE-coated microcatheters for enhanced safety and maneuverability during embolization with NBCA. Furthermore, it highlights the importance of prophylactic embolization during EN for managing NP.

4.
MAGMA ; 2024 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-38916681

RESUMO

PURPOSE: To develop a new MR coronary angiography (MRCA) technique by employing a zigzag fan-shaped centric ky-kz k-space trajectory combined with high-resolution deep learning reconstruction (HR-DLR). METHODS: All imaging data were acquired from 12 healthy subjects and 2 patients using two clinical 3-T MR imagers, with institutional review board approval. Ten healthy subjects underwent both standard 3D fast gradient echo (sFGE) and centric ky-kz k-space trajectory FGE (cFGE) acquisitions to compare the scan time and image quality. Quantitative measures were also performed for signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) as well as sharpness of the vessel. Furthermore, the feasibility of the proposed cFGE sequence was assessed in two patients. For assessing the feasibility of the centric ky-kz trajectory, the navigator-echo window of a 30-mm threshold was applied in cFGE, whereas sFGE was applied using a standard 5-mm threshold. Image quality of MRCA using cFGE with HR-DLR and sFGE without HR-DLR was scored in a 5-point scale (non-diagnostic = 1, fair = 2, moderate = 3, good = 4, and excellent = 5). Image evaluation of cFGE, applying HR-DLR, was compared with sFGE without HR-DLR. Friedman test, Wilcoxon signed-rank test, or paired t tests were performed for the comparison of related variables. RESULTS: The actual MRCA scan time of cFGE with a 30-mm threshold was acquired in less than 5 min, achieving nearly 100% efficiency, showcasing its expeditious and robustness. In contrast, sFGE was acquired with a 5-mm threshold and had an average scan time of approximately 15 min. Overall image quality for MRCA was scored 3.3 for sFGE and 2.7 for cFGE without HR-DLR but increased to 3.6 for cFGE with HR-DLR and (p < 0.05). The clinical result of patients obtained within 5 min showed good quality images in both patients, even with a stent, without artifacts. Quantitative measures of SNR, CNR, and sharpness of vessel presented higher in cFGE with HR-DLR. CONCLUSION: Our findings demonstrate a robust, time-efficient solution for high-quality MRCA, enhancing patient comfort and increasing clinical throughput.

5.
Radiol Case Rep ; 19(6): 2112-2116, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38645534

RESUMO

We describe the endovascular embolization of a 65-year-old man with chronic hepatic encephalopathy. A contrast-enhanced computed tomography demonstrated a splenorenal shunt and a recanalized paraumbilical vein as a continuous portal shunt connecting the left branch of the portal vein and the right common femoral vein. A 2-session embolization was performed for the splenorenal shunt. First, the transvenous approach was used for coil embolization of the splenorenal shunt. It was difficult to advance the catheter system to the embolization site, and it was unstable during coil placement. Second, the paraumbilical venous approach was used to place additional coils. The catheter system had good maneuverability and easily reached the embolization site. Additionally, the stable system allowed for densely packed additional coil implantations. This report demonstrated the paraumbilical venous approach's effectiveness in catheter maneuverability and system stability during coil embolization.

7.
Egypt Heart J ; 75(1): 103, 2023 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-38123754

RESUMO

BACKGROUND: Systemic-to-pulmonary artery shunt (SPAS) is a rare condition that can occur as a result of congenital heart disease or chronic pulmonary inflammation, occasionally leading to life-threatening hemoptysis. Computed tomography (CT) imaging is crucial in the diagnosis of SPAS, and the optimal management approach for SPAS remains uncertain. This case report presents a novel approach to the treatment of SPAS, consisting of transcatheter arterial embolization of the systemic artery followed by lung segmentectomy. CASE PRESENTATION: A 42-year-old man with abnormal chest findings was referred to us and a diagnosis of SPAS was established based on the CT findings showing a blood flow regurgitation from the dilated left 4th intercostal artery to the Lt. A6. The patient was asymptomatic but we decided to treat him to prevent a risk of future hemoptysis. Transcatheter arterial embolization (TAE) of systemic arteries followed by S6 segmentectomy was successfully performed with minimal blood loss and complete removal of the dilated intra-pulmonary blood vessels. Histological analysis confirmed the diagnosis of SPAS. CONCLUSION: We reported a case of SPAS, who was successfully treated with the combination of TAE and subsequent segmentectomy. The blood loss during surgery was minimal and this strategy appeared to minimize future recanalization and hemoptysis. Further studies and long-term follow-up of SPAS patients are required to establish standardized management guidelines for this rare condition.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA