Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
2.
PLoS One ; 11(9): e0163630, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27648953

RESUMO

[This corrects the article DOI: 10.1371/journal.pone.0155717.].

3.
PLoS One ; 11(5): e0155717, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27192201

RESUMO

OBJECT: In MRI, implants and devices can be delineated via susceptibility artefacts. To discriminate susceptibility voids from proton-free structures, different positive contrast techniques were implemented. The purpose of this study was to evaluate a pulse sequence-based positive contrast technique (PCSI) and a post-processing susceptibility gradient mapping algorithm (SGM) for visualization of iron loaded mesh implants in patients. MATERIAL AND METHODS: Five patients with iron-loaded MR-visible inguinal hernia mesh implants were examined at 1.5 Tesla. A gradient echo sequence (GRE; parameters: TR: 8.3ms; TE: 4.3ms; NSA:2; FA:20°; FOV:350mm²) and a PCSI sequence (parameters: TR: 25ms; TE: 4.6ms; NSA:4; FA:20°; FOV:350mm²) with on-resonant proton suppression were performed. SGM maps were calculated using two algorithms. Image quality and mesh delineation were independently evaluated by three radiologists. RESULTS: On GRE, the iron-loaded meshes generated distinct susceptibility-induced signal voids. PCSI exhibited susceptibility differences including the meshes as hyperintense signals. SGM exhibited susceptibility differences with positive contrast. Visually, the different algorithms presented no significant differences. Overall, the diagnostic value was rated best in GRE whereas PCSI and SGM were barely "sufficient". CONCLUSION: Both "positive contrast" techniques depicted implanted meshes with hyperintense signal. SGM comes without additional acquisition time and can therefore be utilized in every patient.

4.
Biomed Res Int ; 2015: 953209, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25973427

RESUMO

Reinforcement of tissues by use of textiles is encouraged by the reduced rate of recurrent tissue dehiscence but for the price of an inflammatory and fibrotic tissue reaction to the implant. The latter mainly is affected by the size of the pores, whereas only sufficiently large pores are effective in preventing a complete scar entrapment. Comparing two different sling implants (TVT and SIS), which are used for the treatment of urinary incontinence, we can demonstrate that the measurement of the effective porosity reveals considerable differences in the textile construction. Furthermore the changes of porosity after application of a tensile load can indicate a structural instability, favouring pore collapse at stress and questioning the use for purposes that are not "tension-free."


Assuntos
Cicatriz/terapia , Próteses e Implantes , Têxteis , Incontinência Urinária por Estresse/terapia , Cicatriz/patologia , Feminino , Humanos , Porosidade , Incontinência Urinária por Estresse/patologia
5.
Invest Radiol ; 50(7): 436-42, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25756683

RESUMO

OBJECTIVES: From a surgeon's point of view, meshes implanted for inguinal hernia repair should overlap the defect by 3 cm or more during implantation to avoid hernia recurrence secondary to mesh shrinkage. The use of magnetic resonance imaging (MRI)-visible meshes now offers the opportunity to noninvasively monitor whether a hernia is still covered sufficiently in the living patient. The purpose of this study was therefore to evaluate the efficacy of hernia repair after mesh implantation based on MRI findings (mesh coverage, visibility of hernia structures) and based on the patient's postoperative symptoms. MATERIALS AND METHODS: In this prospective study approved by the ethics committee, 13 MRI-visible meshes were implanted in 10 patients (3 bilaterally) for inguinal hernia repair between March 2012 and January 2013. Senior visceral surgeons (>7 years of experience) implanted the meshes via laparoscopic transabdominal preperitoneal procedure. Magnetic resonance imaging was performed within 1 week and at 3 months after surgery at a 1.5-T system. Mesh position, deformation, and coverage of the hernia were visually assessed in consensus and rated on a 4-point semiquantitative scoring system. Distances of hernia center point to the mesh borders (overlap) were measured. Mesh position and hernia coverage postoperatively and at 3 months after implantation were correlated with the respective patients' clinical symptoms. Statistical analysis was performed using the Wilcoxon signed rank test. RESULTS: Two of the 13 meshes presented with an atypical mesh configuration along the course of psoas muscle with a short medial overlap of less than 2 cm. Eleven of the 13 meshes exhibited a typical mesh configuration with lateral folding and initial overlap of more than 2 cm. Between baseline and 3 months' follow-up, average overlap decreased in the medial direction by -10% (3.75 cm vs 3.36 cm, P = 0.22), in the lateral direction by -20% (3.55 cm vs 2.82 cm, P = 0.01), in the superior direction by -2% (5.82 cm vs 5.72 cm, P = 0.55), and in the posterior direction by -19% (4.11 cm vs 3.34 cm, P = 0.01). Between baseline and 3 months' follow-up, mesh folding increased mildly in the medial direction, whereas no change was found in the other directions. Individual folds of the mesh were flexible over time, whereas the gross visual configuration and location of meshes did not change. Four of the 13 former hernia sites were mildly painful at follow-up, whereas 9 of the 13 were completely asymptomatic. No correlation between clinical symptoms and mesh position or hernia coverage was found. CONCLUSIONS: Our results suggest that the actual postoperative mesh position after release of laparoscopic pneumoperitoneum may deviate from its position during surgery. Gross mesh position and configuration differed between patients but did not change within a given patient over the observation period of 3 months after surgery. We did not find a correlation between clinical symptoms and mesh configuration or position. Shrinkage of meshes does occur, yet not as concentric process, but regionally variable, leading to a reduced hernia coverage of up to -20% in the lateral and posterior directions.


Assuntos
Hérnia Inguinal/patologia , Hérnia Inguinal/cirurgia , Herniorrafia/métodos , Imageamento por Ressonância Magnética/métodos , Cirurgia Assistida por Computador/métodos , Telas Cirúrgicas , Adulto , Idoso , Feminino , Herniorrafia/instrumentação , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Estatística como Assunto , Resultado do Tratamento
6.
Invest Radiol ; 49(7): 439-44, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24651663

RESUMO

OBJECTIVES: Shrinkage and deformation of mesh implants used for hernia treatment can be the cause of long-term complications. The purpose of this study was to quantify noninvasively time-dependent mesh shrinkage, migration, and configuration changes in patients who were surgically treated for inguinal hernia using magnetic resonance imaging (MRI)-visible mesh implants. MATERIALS AND METHODS: In an agarose phantom, meshes in different shrinkage and folding conditions were used to validate the quantification process. Seven patients who were surgically (3 bilaterally) treated for inguinal hernia using iron-loaded mesh implants were prospectively examined using MRI. Gradient echo sequences in sagittal and transverse orientations were performed on day 1 after surgery and at day 90. The mesh-induced signal voids were semiautomatically segmented and a polygonal surface model was generated. A comparison of area and centroid position was performed between the 2 calculated surfaces (day 1 vs day 90). RESULTS: The phantom study revealed a maximum deviation of 3.6% between the MRI-based quantification and the actual mesh size. All 10 implants were successfully reconstructed. The mean (SD) observed mesh shrinkage 90 days after surgery was 20.9% (7.1%). The mean (SD) centroid movement was 1.17 (0.47) cm. Topographic analysis revealed mean (SD) local configuration changes of 0.23 (0.03) cm. CONCLUSIONS: In this study, significant mesh shrinkage (20.9%) but marginal changes in local mesh configuration occurred within 90 days after mesh implantation. Centroid shift of the mesh implant can be traced back to different patient positioning and abdominal distension. The developed algorithm facilitates noninvasive assessment of key figures regarding MRI-visible meshes. Consequently, it might help to improve mesh technology as well as surgical skills.


Assuntos
Algoritmos , Análise de Falha de Equipamento/métodos , Hérnia/patologia , Herniorrafia/instrumentação , Imageamento por Ressonância Magnética/métodos , Telas Cirúrgicas , Adulto , Idoso , Hérnia/terapia , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Técnica de Subtração , Fatores de Tempo , Resultado do Tratamento
7.
J Biomed Mater Res B Appl Biomater ; 102(7): 1485-95, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24599834

RESUMO

Recurrence rate of hiatal hernia can be reduced with prosthetic mesh repair; however, type and shape of the mesh are still a matter of controversy. The purpose of this study was to investigate the biomechanical properties of four conventional meshes: pure polypropylene mesh (PP-P), polypropylene/poliglecaprone mesh (PP-U), polyvinylidenefluoride/polypropylene mesh (PVDF-I), and pure polyvinylidenefluoride mesh (PVDF-S). Meshes were tested either in warp direction (parallel to production direction) or perpendicular to the warp direction. A Zwick testing machine was used to measure elasticity and effective porosity of the textile probes. Stretching of the meshes in warp direction required forces that were up to 85-fold higher than the same elongation in perpendicular direction. Stretch stress led to loss of effective porosity in most meshes, except for PVDF-S. Biomechanical impact of the mesh was additionally evaluated in a hiatal hernia model. The different meshes were used either as rectangular patches or as circular meshes. Circular meshes led to a significant reinforcement of the hiatus, largely unaffected by the orientation of the warp fibers. In contrast, rectangular meshes provided a significant reinforcement only when warp fibers ran perpendicular to the crura. Anisotropic elasticity of prosthetic meshes should therefore be considered in hiatal closure with rectangular patches.


Assuntos
Hérnia Hiatal/fisiopatologia , Hérnia Hiatal/cirurgia , Teste de Materiais/métodos , Modelos Biológicos , Telas Cirúrgicas
8.
J Biomed Mater Res B Appl Biomater ; 102(6): 1165-9, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24470265

RESUMO

BACKGROUND: Application of a mesh in presence of pneumoperitoneum may cause deformation or wave formation when gas is released. Moreover, mesh shrinkage during subsequent wound healing cannot be detected in vivo without invasive diagnostics. Using MRI-visible polyvinylidene fluoride (PVDF) mesh, the extend of mesh deformation and shrinkage could be objectified by MRI for the first time. MATERIALS AND METHODS: Laparoscopic intraperitoneal onlay mesh (IPOM) implantation was performed in 10 female rabbits using ferro-oxide loaded PVDF meshes. MRI measurements were performed postoperatively at days 1 and 90. After three-dimensional reconstruction of all MRI images the total surface and the effective surface of the implanted mesh were explored and calculated computer-assisted. RESULTS: In all cases, the mesh could be identified in MRI. The subsequent three-dimensional reconstruction always allowed a calculation of the mesh area. In relation to the original size of the used textile implant, we found neither a significant reduction of the effective mesh surface after release of the pneumoperitoneum at day 1 after laparoscopic surgery nor a significant change of the total surface of this large pore mesh by the end of the observation period. CONCLUSIONS: In vivo investigation of mesh surface via MRI could exclude a significant initial reduction of the effective mesh surface after release of pneumoperitoneum, in this IPOM rabbit model. A further subsequent shrinkage of these large pore PVDF meshes could be excluded, as well. Imaging of MRI-visible IPOM mesh turned out to be a sufficient tool to objectify mesh configuration and position in vivo.


Assuntos
Imageamento por Ressonância Magnética , Pneumoperitônio/diagnóstico por imagem , Pneumoperitônio/cirurgia , Polivinil , Telas Cirúrgicas , Animais , Modelos Animais de Doenças , Feminino , Teste de Materiais , Coelhos , Radiografia
9.
J Biomed Mater Res A ; 102(4): 1079-84, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23625516

RESUMO

Use of textile structures for reinforcement of pelvic floor structures has to consider mechanical forces to the implant, which are quite different to the tension free conditions of the abdominal wall. Thus, biomechanical analysis of textile devices has to include the impact of strain on stretchability and effective porosity. Prolift(®) and Prolift + M(®), developed for tension free conditions, were tested by measuring stretchability and effective porosity applying mechanical strain. For comparison, we used Dynamesh-PR4(®), which was designed for pelvic floor repair to withstand mechanical strain. Prolift(®) at rest showed moderate porosity with little stretchability but complete loss of effective porosity at strain of 4.9 N/cm. Prolift + M(®) revealed an increased porosity at rest, but at strain showed high stretchability, with subsequent loss of effective porosity at strain of 2.5 N/cm. Dynamesh PR4(®) preserved its high porosity even under strain, but as consequence of limited stretchability. Though in tension free conditions Prolift(®) and Prolift + M(®) can be considered as large pore class I meshes, application of mechanical strain rapidly lead to collapse of pores. The loss of porosity at mechanical stress can be prevented by constructions with high structural stability. Assessment of porosity under strain was found helpful to define requirements for pelvic floor devices. Clinical studies have to prove whether devices with high porosity as well as high structural stability can improve the patients' outcome.


Assuntos
Cicatriz/patologia , Diafragma da Pelve/fisiopatologia , Próteses e Implantes , Têxteis , Anisotropia , Fenômenos Biomecânicos , Elasticidade , Humanos , Teste de Materiais , Porosidade , Telas Cirúrgicas , Suporte de Carga
10.
Invest Radiol ; 48(11): 770-8, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23732864

RESUMO

OBJECTIVES: Until today, there have been no conventional imaging methods available to visualize surgical mesh implants and related complications. In a new approach, we incorporated iron particles into polymer-based implants and visualized them by magnetic resonance imaging (MRI).After clinical approval of such implants, the purposes of this study were to evaluate the MRI conspicuity of such iron-loaded mesh implants in patients treated for inguinal hernias and to assess the immediate postsurgical mesh configuration. MATERIALS AND METHODS: Approved by the ethics committee, in this prospective cohort study, 13 patients (3 patients with bilateral hernia treatment) were surgically treated for inguinal hernia receiving iron-loaded mesh implants between March and October 2012. The implants were applied via laparoscopic technique (transabdominal preperitoneal technique; n = 8, 3 patients with bilateral hernia treatment) or via open surgical procedure (Lichtenstein surgery; n = 5). Magnetic resonance imaging was performed 1 day after the surgery at a 1.5-T scanner (Achieva; Philips, Best, The Netherlands) with a 16-channel receiver coil using 3 different gradient echo sequences (first gradient echo sequence, second gradient echo sequence, and third gradient echo sequence [GRE1-3]) and 1 T2-weighted turbo spin-echo sequence (T2wTSE). Three radiologists independently evaluated mesh conspicuity and diagnostic value with respect to different structures using a semiquantitative scoring system (1, insufficient; 2, sufficient; 3, good; 4, optimal). Mesh deformation and coverage of the hernia were visually assessed and rated using a 5-point semiquantitative scoring system. Statistical analysis was performed using mixed models and linear contrast. RESULTS: All 16 implants were successfully visualized by MRI. On gradient echo sequences, the mesh is clearly delineated as a thick hypointense line. On T2wTSE, the mesh was depicted as a faint hypointense line, which was difficult to identify. The first gradient echo sequence was rated best for visual conspicuity (mean [SD], 3.8 [0.4]). T2-weighted turbo spin-echo sequence was preferred for evaluation of the surrounding anatomy (mean [SD], 3.7 [0.3]). For the combined assessment of both mesh and anatomy, GRE3 was rated best (mean [SD], 2.9 [0.7]). Local air slightly reduced mesh delineation (lowest mean [SD] rating, 2.9 [0.7] for GRE3). Overall, in both implantation techniques, the meshes exhibited mild to moderate deformations (mean [SD], 3.3 [0.4], 3.1 [0.3], and 2.8 [0.3] on average with open technique, 2.7 [0.3], 2.7 [0.2], and 2.3 [0.3] with laparoscopic technique). Coverage of the hernia was achieved in 15 of the 16 implants. CONCLUSIONS: Combining iron-loaded implants and MRI, we achieved mesh visualization for the first time in patients. For MRI protocol, we propose a combination of different gradient echo sequences and T2-weighted turbo spin-echo sequences: first gradient echo sequence for mesh configuration, T2wTSE for anatomy assessment, and GRE3 for evaluation of hernia coverage and mesh localization. Using our approach, MRI could become a noninvasive alternative to open surgical exploration if mesh-related complications were suspected.


Assuntos
Hérnia Inguinal/cirurgia , Imageamento por Ressonância Magnética/métodos , Complicações Pós-Operatórias/diagnóstico , Telas Cirúrgicas , Adulto , Idoso , Feminino , Humanos , Ferro , Laparoscopia , Masculino , Pessoa de Meia-Idade , Polímeros , Estudos Prospectivos , Resultado do Tratamento
11.
Invest Radiol ; 48(4): 200-5, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23344516

RESUMO

PURPOSE: Polymer-based textile meshes for abdominal hernia treatment are invisible by conventional imaging methods, including magnetic resonance imaging (MRI). Integration of iron particles in the mesh base material allows MRI visualization of meshes. Positive-contrast susceptibility imaging (PCSI) was implemented to separate susceptibility-induced voids from proton-deficient voids. The purpose of this study was to compare PCSI with conventional gradient echo and turbo spin echo (TSE) sequences for the in vivo assessment of superparamagnetic iron oxide particle-loaded surgical meshes in an animal model. METHODS AND MATERIALS: Iron-loaded polymer meshes were implanted into the abdominal wall of 10 rabbits. At days 1, 30, and 90 after surgery, conventional gradient echo, TSE, and PCSI were performed at 1.5 T in the sagittal and axial planes. Images were scored by 2 radiologists with respect to mesh visibility, delineation of the surrounding tissue, differentiation from other structures, and overall diagnostic use, on a 4-point scale ranging from 1 (insufficient) to 4 (excellent). The results were compared using Wilcoxon signed-rank tests. The mesh shape, possible deformation or fracture, and possible mesh migration were evaluated on the different pulse sequences and compared with the results at surgery and autopsy. RESULTS: The iron-loaded meshes appeared as hypointense signal voids on gradient echo sequences, as a hyperintense line on PCSI, and as a very thin dark line on TSE images. In all animals, a precise depiction of the mesh location and its spatial configuration and integrity was possible by MRI and confirmed by surgical and autopsy results. In all 4 categories and at all 3 time points of imaging, image quality scores were significantly higher for gradient echo imaging (range, 3.60-3.80) compared with PCSI (range, 3.12-3.42) and TSE (range, 1.64-1.89). At day 90, the image quality ratings of gradient echo and PCSI were comparable. In 2 cases, the complete delineation of mesh borders was impossible because of signal voids of adjacent anatomical structures, whereas PCSI helped achieve this differentiation. CONCLUSION: In this rabbit model of iron-loaded implanted abdominal meshes, standard gradient echo imaging was best suitable to assess implant location, integrity, and configuration. In 2 of 10 animals, PCSI helped achieve a complete delineation of mesh borders.


Assuntos
Hérnia Abdominal/cirurgia , Imageamento por Ressonância Magnética/métodos , Telas Cirúrgicas , Animais , Dextranos , Imageamento Tridimensional , Estudos Longitudinais , Nanopartículas de Magnetita , Polímeros , Coelhos , Estatísticas não Paramétricas
12.
World J Surg Oncol ; 10: 159, 2012 Aug 06.
Artigo em Inglês | MEDLINE | ID: mdl-22866813

RESUMO

BACKGROUND: The aim of this study was to analyze the early postoperative outcome of esophageal cancer treated by subtotal esophageal resection, gastric interposition and either intrathoracic or cervical anastomosis in a single center study. METHODS: 72 patients who received either a cervical or intrathoracic anastomosis after esophageal resection for esophageal cancer were matched by age and tumor stage. Collected data from these patients were analyzed retrospectively regarding morbidity and mortality rates. RESULTS: Anastomotic leakage rate was significantly lower in the intrathoracic anastomosis group than in the cervical anastomosis group (4 of 36 patients (11%) vs. 11 of 36 patients (31%); p = 0.040). The hospital stay was significantly shorter in the intrathoracic anastomosis group compared to the cervical anastomosis group (14 (range 10-110) vs. 26 days (range 12 - 105); p = 0.012). Wound infection and temporary paresis of the recurrent laryngeal nerve occurred significantly more often in the cervical anastomosis group compared to the intrathoracic anastomosis group (28% vs. 0%; p = 0.002 and 11% vs. 0%; p = 0.046). The overall In-hospital mortality rate was 6% (4 of 72 patients) without any differences between the study groups. CONCLUSIONS: The present data support the assumption that the transthoracic approach with an intrathoracic anastomosis compared to a cervical esophagogastrostomy is the safer and more beneficial procedure in patients with carcinoma of the lower and middle third of the esophagus due to a significant reduction of anastomotic leakage, wound infection, paresis of the recurrent laryngeal nerve and shorter hospital stay.


Assuntos
Adenocarcinoma/cirurgia , Anastomose Cirúrgica/métodos , Carcinoma de Células Escamosas/cirurgia , Neoplasias Esofágicas/cirurgia , Esofagectomia , Complicações Pós-Operatórias , Adenocarcinoma/patologia , Carcinoma de Células Escamosas/patologia , Neoplasias Esofágicas/patologia , Feminino , Mortalidade Hospitalar , Humanos , Masculino , Análise por Pareamento , Pessoa de Meia-Idade , Gradação de Tumores , Estadiamento de Neoplasias , Estudos Prospectivos , Estudos Retrospectivos , Taxa de Sobrevida
13.
Ann Intensive Care ; 2 Suppl 1: S7, 2012 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-22873423

RESUMO

BACKGROUND: Abdominal compartment syndrome (ACS) is a life threatening condition that may affect any critically ill patient. Little is known about the recognition and management of ACS in Germany. METHODS: A questionnaire was mailed to departments of surgery and anesthesia from German hospitals with more than 450 beds. RESULTS: Replies (113) were received from 222 eligible hospitals (51%). Most respondents (95%) indicated that ACS plays a role in their clinical practice. Intra-abdominal pressure (IAP) is not measured at all by 26%, while it is routinely done by 30%. IAP is mostly (94%) assessed via the intra-vesical route. Of the respondents, 41% only measure IAP in patients expected to develop ACS; 64% states that a simpler, more standardized application of IAP measurement would lead to increased use in daily clinical practice. CONCLUSIONS: German anesthesiologists and surgeons are familiar with ACS. However, approximately one fourth never measures IAP, and there is considerable uncertainty regarding which patients are at risk as well as how often IAP should be measured in them.

14.
Ann Intensive Care ; 2 Suppl 1: S8, 2012 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-22873424

RESUMO

INTRODUCTION: Several decades ago, the beneficial effects of goal-directed therapy, which include decompressive laparotomy (DL) and open abdomen procedures in cases of intra-abdominal hypertension (IAH) in children, were proven in the context of closures of abdominal wall defects and large-for-size organ transplantations. Different neonatologic and pediatric disease patterns are also known to be capable of increasing intra-abdominal pressure (IAP). Nevertheless, a considerable knowledge transfer regarding such risk factors has hardly taken place. When left undetected and untreated, IAH threatens to evolve into abdominal compartment syndrome (ACS), which is accompanied by a mortality rate of up to 60% in children. Therefore, the present study looks at the recognition and knowledge of IAH/ACS among German pediatric intensivists. METHODS: In June 2010, a questionnaire was mailed to the heads of pediatric intensive care units of 205 German pediatric hospitals. RESULTS: The response rate was 62%. At least one case of IAH was reported by 36% of respondents; at least one case of ACS, by 25%. Compared with adolescents, younger critically ill children appeared to develop IAH/ACS more often. Routine measurements of IAP were said to be performed by 20% of respondents. Bladder pressure was used most frequently (96%) to assess IAP. Some respondents (17%) only measured IAP in cases of organ dysfunction and failure. In 2009, the year preceding this study, 21% of respondents claimed to have performed a DL. Surgical decompression was indicated if signs of organ dysfunction were present. This was also done in cases of at least grade III IAH (IAP > 15 mmHg) without organ impairment. CONCLUSIONS: Although awareness among pediatricians appears to have been increasing over the last decade, definitions and guidelines regarding the diagnosis and management of IAH/ACS are not applied uniformly. This variability could express an ever present lack of awareness and solid prospective data.

15.
Invest Radiol ; 47(6): 359-67, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22543968

RESUMO

OBJECTIVES: Conventional radiological methods, including magnetic resonance imaging (MRI), fail to visualize polymeric surgical mesh implants because of small thread dimensions and material characteristics. For MRI delineation of such meshes, superparamagnetic iron oxide particles (SPIOs) are integrated in the mesh polymer. Usually, if SPIOs are used as an intravenous contrast agent, they increase the R1 and R2 of adjacent protons. It can be assumed that embedding SPIOs in polymers alters their molecular dynamics. The aim of this study was to investigate the influence of SPIO integration in polymer on the relaxation of adjacent protons. MATERIALS AND METHODS: Polymer threads were placed in an agarose phantom. At 1.5 T, R1, R2, and R2* maps were calculated from multi inversion-recovery spin echo, multi-spin echo, and multi-gradient echo images, respectively. The threads were aligned parallel or orthogonal to B(0). RESULTS: No impact of SPIO on proton R1 and R2 was observed. R2* was increased by the SPIO-loaded threads. R1 and R2 amplitude maps showed a magnetic susceptibility difference of 0.97 ppm/(mg SPIO/g polymer) around SPIO-loaded threads. CONCLUSIONS: In contrast to SPIO in aqueous solutions, polymer-embedded SPIO do not affect proton R1 and R2. However, embedded SPIO generate strong local static magnetic field gradients. Thus, SPIO integration is suitable to control the magnetic susceptibility of polymer threads. This can be exploited to visualize implanted polymer-based meshes in MRI using R2* susceptible sequences. Because no impact on R1 and R2 of adjacent protons by SPIO embedded in mesh threads was observed, structures adjacent to implanted meshes will be observable in R1 and R2 maps.


Assuntos
Compostos Férricos/análise , Compostos Férricos/química , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética/métodos , Polímeros/química , Telas Cirúrgicas , Prótons
16.
Surg Endosc ; 26(5): 1468-75, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22179447

RESUMO

BACKGROUND: Prosthetic mesh implants are widely used in hernia surgery. To show long-term mesh-related complications such as shrinkage or adhesions, a precise visualization of meshes and their vicinity in vivo is important. By supplementing mesh fibers with ferro particles, magnetic resonance imaging (MRI) can help to delineate the mesh itself. This study aimed to demonstrate and quantify time-dependent mesh shrinkage in vivo by MRI. METHODS: Polyvinylidenfluoride (PVDF) meshes with incorporated superparamagnetic iron oxides (SPIOs) were implanted as an abdominal wall replacement in 30 rats. On days 1, 7, 14, or 21, MRI was performed using a gradient echo sequence with repetition time (TR)/echo time (TE) of 50/4.6 and a flip angle of 20°. The length, width, and area of the device were measured on axial, coronal, and sagittal images, and geometric deformations were assessed by surgical explantation. RESULTS: In all cases, the meshes were visualized and their area estimated by measuring the length and width of the mesh. The MRI presented a mean area shrinkage in vivo of 13% on day 7, 23% on day 14, and 23% on day 21. Postmortem measurements differed statistically from MRI, with a mean area shrinkage of 23% on day 7, 28% on day 14, and 30% on day 21. Ex vivo measurements of shrinkage showed in vivo measurements to be overestimated approximately 8%. Delineation of the mesh helped to show folding or adhesions close to the intestine. CONCLUSION: Loading of surgical meshes with SPIOs allows their precise visualization during MRI and guarantees an accurate in vivo assessment of their shrinkage. The authors' observation clearly indicates that shrinkage in vivo is remarkably less than that shown by illustrated explantation measurements. The use of MRI with such meshes could be a reliable technique for checking on proper operation of implanted meshes and showing related complications, obviating the need for exploratory open surgical revision.


Assuntos
Compostos de Ferro , Telas Cirúrgicas/normas , Animais , Desenho de Equipamento , Hérnia Abdominal/cirurgia , Imageamento por Ressonância Magnética , Masculino , Polivinil/uso terapêutico , Próteses e Implantes , Ratos , Ratos Sprague-Dawley
17.
J Surg Res ; 163(2): e67-72, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20739030

RESUMO

INTRODUCTION: Anastomotic failure is one of the most frequent complications in abdominal surgery. During anastomotic healing. the strength of the intestinal tissue nearby is closely related to the accumulation of collagen in interlinked scar tissue. This in turn is influenced, among other things, by single groups of matrixmetalloproteinases, especially collagenases (MMP-1, -8, and -13) and gelatinases (MMP-2 and -9). EPO is known to induce the expression of tissue-inhibitor-of-matrixmetalloproteinases-1 (TIMP-1) and thereby to down-regulate MMPs. MATERIALS AND METHODS: We used a rat as an experimental model and applied a high dose of EPO (5U/g BW s.c.), one dose 24 h before operation (as pre-conditioning) and one dose directly after performing a colonic anastomosis. After 3 and after 5 d, respectively, immunohistochemical stainings for MMP-2, -8, and -9 as well as TIMP-1 were carried out and evaluated semiquantitatively for each layer of the colonic wall. Sirius-red staining and cross-polarization microscopy were evaluated and the collagen I/III ratio calculated. Anastomotic and colonic tissue distal to the anastomosis were used to determine collagen content. RESULTS: We found increased bursting pressure 5 d post-surgery after applying erythropoietin. It was thus shown that EPO influences collagen metabolism and changes the collagen I/III ratio in the colon distal to the anastomosis. The evaluation of immunohistochemistry did not show the expected ubiquitous up-regulation of TIMP-1 and down-regulation of MMPs. Nevertheless, correlations between TIMP-1, MMP-8, and collagen I/III ratio could only be established after the application of EPO. CONCLUSION: Contrary to our hypothesis, the picture of TIMP-1 and of the regulation of the MMPs after the application of EPO is not as clear as expected. EPO improves anastomotic bursting strength and the correlation of TIMP-1, MMP-8, and collagen type I/III ratio can only be seen after the application of EPO.


Assuntos
Anastomose Cirúrgica , Colágeno/metabolismo , Colo/cirurgia , Eritropoetina/farmacologia , Cicatrização/efeitos dos fármacos , Animais , Hemoglobinas/análise , Imuno-Histoquímica , Masculino , Metaloproteinases da Matriz/análise , Modelos Animais , Ratos , Ratos Sprague-Dawley , Proteínas Recombinantes , Inibidor Tecidual de Metaloproteinase-1/análise
18.
Invest Radiol ; 45(8): 477-83, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20531013

RESUMO

PURPOSE: To develop a method for visualizing surgical textile implant (STI) with superparamagnetic iron oxides (SPIO), using magnetic resonance imaging (MRI). Therefore, positive-contrast inversion-recovery with on-resonant water suppression (IRON) was applied and its properties were evaluated in vitro. MATERIALS AND METHODS: STI with different concentrations of SPIO integrated into the base material were produced. Imaging was performed on a clinical 1.5 Tesla scanner, using conventional balanced gradient echo sequences (SSFP), T2*-weighted sequences, and IRON-imaging. In vitro experiments were conducted in an agarose phantom. On MR-images, contrast-to-noise-ratios, and the dimensions of the implant were assessed. RESULTS: Conventional MRI exhibited SPIO-loaded STI as signal voids. Using IRON, the mesh was clearly exhibited hyperintensely with suppression of on-resonant background signals with a distinct differentiation to other sources of off-resonances. Concentrations of approximately 9 mg/g led to best positive contrast and highest contrast-to-noise-ratios using IRON. Depending on B0-orientation, phase encoding direction and the STI's SPIO-load, the IRON-signal showed a characteristic pattern and an overestimation of STI size up to 4.6 mm. CONCLUSION: The integration of SPIOs into the base material combined with IRON is a feasible approach to visualize STI with MRI. This method could help to identify mesh-related problems in time and to reduce the need for surgical revision.


Assuntos
Imageamento por Ressonância Magnética/métodos , Próteses e Implantes , Telas Cirúrgicas , Têxteis , Meios de Contraste , Estudos de Viabilidade , Óxido Ferroso-Férrico/química , Humanos , Técnicas In Vitro , Indicadores e Reagentes/química , Imageamento por Ressonância Magnética/instrumentação , Imagens de Fantasmas , Polímeros , Polivinil
19.
Shock ; 33(6): 639-45, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19940813

RESUMO

Intra-abdominal hypertension (IAH) and abdominal compartment syndrome are increasingly observed in patients with severe acute pancreatitis (SAP). The aim of this study was to investigate the effects of IAH on pancreatic histology and ultrastructure in a porcine model. We examined 16 intubated and anesthetized domestic pigs with a mean body weight of 50.6 (SD, 3.8) kg. Using a CO2 pneumoperitoneum, the intra-abdominal pressure was increased to 30 mmHg for an investigation period of 6 or 12 h (each study group n = 6). In the control group, the intra-abdominal pressure remained 3.9 (SD, 5.4) mmHg for 12 h. Additional Ringer's solution was infused to maintain cardiac output at the level of controls. After the observation period, specimens were taken for histological and ultrastructural analysis, and animals were killed. Cardiac output did not change when compared with control. Histologically, mild- to moderate-grade necrosis was observed after 12 h of IAH. In the ultrastructural analysis, leukocyte infiltration and swelling of endothelial cells were found. In the acinar cells of the exocrine pancreas, endoplasmic reticulum was dilated, and necrosis was noticed. Mitochondrial damage manifested as cisternal destruction with formation of large vacuoles. In this porcine model, 6 and 12 h of IAH resulted in light-microscopical and ultrastructural changes comparable to pancreatitis in humans. As SAP is often accompanied by IAH, the finding of the underlying study suggests a vicious cycle in which IAH may worsen pancreatitis. Ultimately, these findings are in favor of a decompression in patients with SAP and IAH.


Assuntos
Hipertensão/patologia , Pâncreas/patologia , Pâncreas/ultraestrutura , Abdome/fisiopatologia , Animais , Pressão Sanguínea , Dióxido de Carbono/sangue , Débito Cardíaco , Síndromes Compartimentais/etiologia , Síndromes Compartimentais/patologia , Síndromes Compartimentais/fisiopatologia , Modelos Animais de Doenças , Hipertensão/complicações , Masculino , Oxigênio/sangue , Pancreatite/complicações , Pressão Parcial , Pressão , Suínos , Equilíbrio Hidroeletrolítico
20.
J Invest Surg ; 22(4): 256-62, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19842900

RESUMO

Placement of mesh is involved in 75-80% of hernia operations. It is known that an exaggerated foreign body reaction leads to clinical complications. To further improve patients outcome using biotechnological agents targeted against tumor necrosis factor-alpha (TNF-alpha) or interleukin-6 (IL-6), a study was conducted investigating the impact of cytokine knockout on mesh integration. Sixty mice were used: C57BL/6 wild type control, C57BL/6-IL-6 interleukin-6 knockout, C57BL/6-Tnfrsf1a knockout of TNF-alpha receptor 1, and C57BL/6-Tnfrsf1b knockout of TNF-alpha receptor 2. Standard polypropylene mesh was implanted subcutaneously for 7, 21, and 90 days. The inflammatory and connective tissue formation was characterized by diameter of inner cellular infiltrate and outer fibrous capsule of the foreign body granuloma, and by quantity (collagen/protein ratio) and quality (collagen type I/III ratio) of collagen formation. Microscopic investigation of the mesh/host-tissue interface showed typical formation of foreign body granulomas. Ninety days after implantation none of the knockout strains showed significant differences compared to the control group investigating amount of inflammatory and connective tissue formation. Analyzing the quantity of filamentary collagen deposition the C57BL/6-IL-6 group showed significant lowered values compared to the control group 90 days after implantation. In all groups collagen type I/III ratio increased over time as an indicator for maturation of the surrounding collagen formation. However, no difference was found comparing strains at the end of the observation period. The results support the notion that wound healing is affected by cytokine deficiency. However, a desirable reduced amount of inflammatory tissue formation as well as an increased collagen type I/III ratio due to cytokine knockout could not be observed.


Assuntos
Inflamação/prevenção & controle , Interleucina-6/genética , Próteses e Implantes , Receptores Tipo II do Fator de Necrose Tumoral/genética , Receptores Tipo I de Fatores de Necrose Tumoral/genética , Telas Cirúrgicas/efeitos adversos , Animais , Colágeno Tipo I/metabolismo , Colágeno Tipo III/metabolismo , Reação a Corpo Estranho , Hérnia Inguinal/cirurgia , Camundongos , Camundongos Endogâmicos C57BL , Camundongos Knockout , Fator de Necrose Tumoral alfa
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA