Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
1.
Am J Clin Oncol ; 45(6): 249-257, 2022 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-35588224

RESUMO

AIM/OBJECTIVES/BACKGROUND: The American College of Radiology (ACR), American Brachytherapy Society (ABS), and American Society for Radiation Oncology (ASTRO) have jointly developed the following practice parameter for transperineal permanent brachytherapy of prostate cancer. Transperineal permanent brachytherapy of prostate cancer is the interstitial implantation of low-dose rate radioactive seeds into the prostate gland for the purpose of treating localized prostate cancer. METHODS: This practice parameter was developed according to the process described under the heading The Process for Developing ACR Practice Parameters and Technical Standards on the ACR website (https://www.acr.org/Clinical-Resources/Practice-Parameters-and-Technical-Standards) by the Committee on Practice Parameters-Radiation Oncology of the Commission on Radiation Oncology, in collaboration with ABS and ASTRO. RESULTS: This practice parameter provides a framework for the appropriate use of low-dose rate brachytherapy in the treatment of prostate cancer either as monotherapy or as part of a treatment regimen combined with external-beam radiation therapy. The practice parameter defines the qualifications and responsibilities of all involved radiation oncology personnel, including the radiation oncologist, medical physicist, dosimetrist, radiation therapist, and nursing staff. Patient selection criteria and the utilization of supplemental therapies such as external-beam radiation therapy and androgen deprivation therapy are discussed. The logistics of the implant procedure, postimplant dosimetry assessment, and best practices with regard to safety and quality control are presented. CONCLUSIONS: Adherence to established standards can help to ensure that permanent prostate brachytherapy is delivered in a safe and efficacious manner.


Assuntos
Braquiterapia , Neoplasias da Próstata , Radioterapia (Especialidade) , Antagonistas de Androgênios , Braquiterapia/métodos , Humanos , Masculino , Seleção de Pacientes , Neoplasias da Próstata/radioterapia
2.
Am J Clin Oncol ; 45(6): 243-248, 2022 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-35485607

RESUMO

AIM/OBJECTIVES/BACKGROUND: The American College of Radiology (ACR), the American Brachytherapy Society (ABS), and the American Society for Radiation Oncology (ASTRO) have jointly developed the following practice parameter for the performance of low-dose-rate (LDR) brachytherapy. LDR brachytherapy is the application of radioactive sources in or on tumors in a clinical setting with therapeutic intent. The advantages of LDR brachytherapy include improving therapeutic ratios with lower doses to nontarget organs-at-risk and higher doses to a specific target. METHODS: This practice parameter was developed according to the process described under the heading. The Process for Developing ACR Practice Parameters and Technical Standards on the ACR website (https://www.acr.org/Clinical-Resources/Practice-Parameters-and-Technical-Standards) by the Committee on Practice Parameters-Radiation Oncology of the Commission on Radiation Oncology, in collaboration with ABS and ASTRO. RESULTS: This practice parameter was developed to serve as a tool in the appropriate application of this evolving technology in the care of cancer patients or other patients with conditions where radiation therapy is indicated. It addresses clinical implementation of LDR brachytherapy including personnel qualifications, quality assurance standards, indications, and suggested documentation. This includes a contemporary literature search. CONCLUSIONS: This practice parameter is a tool to guide the use of LDR brachytherapy and does not assess relative clinical indication for LDR brachytherapy when compared with other forms of brachytherapy or external beam therapy, but to focus on the best practices required to deliver LDR brachytherapy safely and effectively, when clinically indicated. Comparative costs of versus other modalities therapy may also need to be considered.


Assuntos
Braquiterapia , Neoplasias , Radioterapia (Especialidade) , Humanos , Neoplasias/radioterapia , Dosagem Radioterapêutica , Sociedades Médicas , Estados Unidos
3.
Brachytherapy ; 20(3): 497-511, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33824051

RESUMO

PURPOSE: The American College of Radiology (ACR), American Brachytherapy Society (ABS), American College of Nuclear Medicine (ACNM), American Society for Radiation Oncology (ASTRO), Society of Interventional Radiology (SIR), and Society of Nuclear Medicine and Molecular Imaging (SNMMI) have jointly developed a practice parameter on selective internal radiation therapy (SIRT) or radioembolization for treatment of liver malignancies. Radioembolization is the embolization of the hepatic arterial supply of hepatic primary tumors or metastases with a microsphere yttrium-90 brachytherapy device. MATERIALS AND METHODS: The ACR -ABS -ACNM -ASTRO -SIR -SNMMI practice parameter for SIRT or radioembolization for treatment of liver malignancies was revised in accordance with the process described on the ACR website (https://www.acr.org/ClinicalResources/Practice-Parameters-and-Technical-Standards) by the Committee on Practice Parameters-Interventional and Cardiovascular Radiology of the ACR Commission on Interventional and Cardiovascular, Committee on Practice Parameters and Technical Standards-Nuclear Medicine and Molecular Imaging of the ACR Commission on Nuclear Medicine and Molecular Imaging and the Committee on Practice Parameters-Radiation Oncology of the ACR Commission on Radiation Oncology in collaboration with ABS, ACNM, ASTRO, SIR, and SNMMI. RESULTS: This practice parameter is developed to serve as a tool in the appropriate application of radioembolization in the care of patients with conditions where indicated. It addresses clinical implementation of radioembolization including personnel qualifications, quality assurance standards, indications, and suggested documentation. CONCLUSIONS: This practice parameter is a tool to guide clinical use of radioembolization. It focuses on the best practices and principles to consider when using radioemboliozation effectively. The clinical benefit and medical necessity of the treatment should be tailored to each individual patient.


Assuntos
Braquiterapia , Neoplasias Hepáticas , Medicina Nuclear , Radioterapia (Especialidade) , Braquiterapia/métodos , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/radioterapia , Imagem Molecular , Radioisótopos de Ítrio/uso terapêutico
4.
Brachytherapy ; 19(6): 762-766, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32952055

RESUMO

PURPOSE: Safe delivery of brachytherapy and establishing a safety culture are critical in high-quality brachytherapy. The American Brachytherapy Society (ABS) Quality and Safety Committee surveyed members regarding brachytherapy services offered, safety practices during treatment, quality assurance procedures, and needs to develop safety and training materials. METHODS AND MATERIALS: A 22-item survey was sent to ABS membership in early 2019 to physicians, physicists, therapists, nurses, and administrators. Participation was voluntary. Responses were summarized with descriptive statistics and relative frequency distributions. RESULTS: There were 103 unique responses. Approximately one in three was attending physicians and one in three attending physicists. Most were in practice >10 years. A total of 94% and 50% performed gynecologic and prostate brachytherapy, respectively. Ninety-one percent performed two-identification patient verification before treatment. Eighty-six percent performed a time-out. Ninety-five percent had an incident reporting or learning system, but only 71% regularly reviewed incidents. Half reviewed safety practices within the last year. Twenty percent reported they were somewhat or not satisfied with department safety culture, but 92% of respondents were interested in improving safety culture. Most reported time, communication, and staffing as barriers to improving safety. Most respondents desired safety-oriented webinars, self-assessment modules, learning modules, or checklists endorsed by the ABS to improve safety practice. CONCLUSIONS: Most but not all practices use standards and quality assurance procedures in line with society recommendations. There is a need to heighten safety culture at many departments and to shift resources (e.g., time or staffing) to improve safety practice. There is a desire for society guidance to improve brachytherapy safety practices. This is the first survey to assess safety practice patterns among a national sample of radiation oncologists with expertise in brachytherapy.


Assuntos
Braquiterapia/estatística & dados numéricos , Neoplasias dos Genitais Femininos/radioterapia , Segurança do Paciente , Neoplasias da Próstata/radioterapia , Garantia da Qualidade dos Cuidados de Saúde/estatística & dados numéricos , Radioterapia (Especialidade)/organização & administração , Braquiterapia/efeitos adversos , Braquiterapia/normas , Lista de Checagem , Comunicação , Feminino , Humanos , Masculino , Cultura Organizacional , Sistemas de Identificação de Pacientes/estatística & dados numéricos , Admissão e Escalonamento de Pessoal , Melhoria de Qualidade , Gestão de Riscos/estatística & dados numéricos , Inquéritos e Questionários , Fatores de Tempo
5.
Brachytherapy ; 19(6): 820-826, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32928682

RESUMO

The American Brachytherapy Society brachytherapy schools have been pivotal in teaching and evolving the art of brachytherapy over the past decades. Founded in 1995, the schools have consistently provided content for the major disease sites including gynecologic, prostate, and breast with ocular, vascular, head and neck, pediatric, intraluminal, systemic, and intraoperative approaches more selectively addressed. In addition, Physics schools, either coupled with clinical schools or as stand-alone venues, have provided an essential educational component for practicing physicists, a pivotal part of the brachytherapy team. Celebrating 25 years in existence, this historical overview of the American Brachytherapy Society brachytherapy schools is a tribute to the many teachers who have shared their expertise, to the many students who have been enthusiastic and interactive participants, and the staff who have made it all possible, with the reward of perpetuating the important and timely art of brachytherapy.


Assuntos
Braquiterapia , Física/educação , Radioterapia (Especialidade)/educação , Instituições Acadêmicas/história , Sociedades Médicas/história , História do Século XX , História do Século XXI , Humanos , Estados Unidos
6.
Brachytherapy ; 19(6): 874-880, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32950407

RESUMO

Developing any new radiation oncology program requires planning and analysis of the current state of the facility and its capacity to take on another program. Staff must consider a large number of factors to establish a feasible, safe, and sustainable program. We present a simple and generic outline that lays out the process for developing and implementing a new HDR brachytherapy program in any setting, but with particular emphasis on challenges associated with starting the program in a limited resource setting. The sections include feasibility of a program, starting cases, machine and equipment selection, and quality and safety.


Assuntos
Braquiterapia , Desenvolvimento de Programas/métodos , Radioterapia (Especialidade)/organização & administração , Braquiterapia/efeitos adversos , Braquiterapia/instrumentação , Braquiterapia/métodos , Braquiterapia/normas , Humanos , Garantia da Qualidade dos Cuidados de Saúde , Radioterapia (Especialidade)/educação , Dosagem Radioterapêutica , Gestão da Segurança
7.
Med Phys ; 47(10): e951-e987, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32862452

RESUMO

The surface brachytherapy Task Group report number 253 discusses the common treatment modalities and applicators typically used to treat lesions on the body surface. Details of commissioning and calibration of the applicators and systems are discussed and examples are given for a risk-based analysis approach to the quality assurance measures that are necessary to consider when establishing a surface brachytherapy program.


Assuntos
Braquiterapia , Calibragem , Dosagem Radioterapêutica , Relatório de Pesquisa
8.
Brachytherapy ; 19(4): 415-426, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32409128

RESUMO

PURPOSE: Keratinocyte carcinoma (KC, previously nonmelanoma skin cancer) represents the most common cancer worldwide. While surgical treatment is commonly utilized, various radiation therapy techniques are available including external beam and brachytherapy. As such, the American Brachytherapy Society has created an updated consensus statement regarding the use of brachytherapy in the treatment of KCs. METHODS: Physicians and physicists with expertise in skin cancer and brachytherapy created a consensus statement for appropriate patient selection, data, dosimetry, and utilization of skin brachytherapy and techniques based on a literature search and clinical experience. RESULTS: Guidelines for patient selection, evaluation, and dose/fractionation schedules to optimize outcomes for patients with KC undergoing brachytherapy are presented. Studies of electronic brachytherapy are emerging, although limited long-term data or comparative data are available. Radionuclide-based brachytherapy represents an appropriate option for patients with small KCs with multiple techniques available. CONCLUSIONS: Skin brachytherapy represents a standard of care option for appropriately selected patients with KC. Radionuclide-based brachytherapy represents a well-established technique; however, the current recommendation is that electronic brachytherapy be used for KC on prospective clinical trial or registry because of a paucity of mature data.


Assuntos
Braquiterapia/normas , Carcinoma Basocelular/radioterapia , Carcinoma de Células Escamosas/radioterapia , Neoplasias Cutâneas/radioterapia , Braquiterapia/métodos , Consenso , Fracionamento da Dose de Radiação , Humanos , Seleção de Pacientes , Radioisótopos/uso terapêutico , Estados Unidos
9.
Med Phys ; 47(8): e913-e919, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32246456

RESUMO

The purpose of this report is to provide detailed guidance on the dosimetry of the INTRABEAM® (Carl Zeiss Medical AG, Jena, Germany) electronic brachytherapy (eBT) system as it stands at the present time. This report has been developed by the members of American Association of Physicists in Medicine (AAPM) Task Group 292 and endorsed by the AAPM. Members of AAPM Task Group 292 on Electronic-Brachytherapy Dosimetry have reviewed pertinent publications and user manuals regarding the INTRABEAM system dosimetry and manufacturer-supplied dose calculation protocols. Formal written correspondence with Zeiss has also provided further clarification. Dose-rate calculations for the INTRABEAM system are highly dependent on choice of dosimetry protocol. Even with careful protocol selection, large uncertainties remain due to the incomplete characterization of the ionization chambers used for verification with respect to their energy dependence as well as manufacturing variations. There are two distinct sets of dose-rate data provided by Zeiss for the INTRABEAM system. One dataset (Calibration V4.0) is representative of the physical dose surrounding the source and the other dataset (TARGIT) has been adjusted to be consistent with a clinical trial named TARGIT (TARGeted Intraoperative RadioTherapy). The adjusted TARGIT doses are quite dissimilar to the physical doses, with differences ranging from 14% to 30% at the surface of a spherical applicator, depending on its diameter, and up to a factor of two at closer distances with the smaller needle applicators. In addition, ion chamber selection and associated manufacturing tolerances contribute to significant additional uncertainties. With these substantial differences in dose rates and their associated uncertainties, it is important for users to be aware of how each value is calculated and whether it is appropriate to be used for the intended treatment. If users intend to deliver doses that are the same as they were in 1998 at the onset of the TARGIT trial, then the TARGIT dose-rate tables should be used. The Calibration V4.0 dose rates may be more appropriate to use for applications other than TARGIT trial treatments, since they more closely represent the physical doses being delivered. Users should also be aware of the substantial uncertainties associated with the provided dose rates, which are due to beam hardening, chamber geometry, and selection of the point-of-measurement for a given ionization chamber. This report serves to describe the details and implications of the manufacturer-recommended dosimetry formalism for users of the INTRABEAM system.


Assuntos
Braquiterapia , Calibragem , Eletrônica , Alemanha , Radiometria , Dosagem Radioterapêutica , Estados Unidos
10.
Med Phys ; 47(4): e65-e91, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31702063

RESUMO

PURPOSE: The purpose of this study was to provide guidance on quality management for electronic brachytherapy. MATERIALS AND METHODS: The task group used the risk-assessment approach of Task Group 100 of the American Association of Physicists in Medicine. Because the quality management program for a device is intimately tied to the procedure in which it is used, the task group first designed quality interventions for intracavitary brachytherapy for both commercial electronic brachytherapy units in the setting of accelerated partial-breast irradiation. To demonstrate the methodology to extend an existing risk analysis for a different application, the task group modified the analysis for the case of post-hysterectomy, vaginal cuff irradiation for one of the devices. RESULTS: The analysis illustrated how the TG-100 methodology can lead to interventions to reduce risks and improve quality for each unit and procedure addressed. CONCLUSION: This report provides a model to guide facilities establishing a quality management program for electronic brachytherapy.


Assuntos
Braquiterapia/instrumentação , Equipamentos e Provisões Elétricas , Relatório de Pesquisa , Sociedades Médicas , Controle de Qualidade , Medição de Risco , Fluxo de Trabalho
11.
Brachytherapy ; 16(6): 1083-1090, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28988661

RESUMO

BACKGROUND: This collaborative practice parameter technical standard has been created between the American College of Radiology and American Brachytherapy Society to guide the usage of electronically generated low energy radiation sources (ELSs). It refers to the use of electronic X-ray sources with peak voltages up to 120 kVp to deliver therapeutic radiation therapy. MAIN FINDINGS: The parameter provides a guideline for utilizing ELS, including patient selection and consent, treatment planning, and delivery processes. The parameter reviews the published clinical data with regard to ELS results in skin, breast, and other cancers. CONCLUSIONS: This technical standard recommends appropriate qualifications of the involved personnel. The parameter reviews the technical issues relating to equipment specifications as well as patient and personnel safety. Regarding suggestions for educational programs with regard to this parameter,it is suggested that the training level for clinicians be equivalent to that for other radiation therapies. It also suggests that ELS must be done using the same standards of quality and safety as those in place for other forms of radiation therapy.


Assuntos
Radioterapia/instrumentação , Radioterapia/normas , Braquiterapia/instrumentação , Braquiterapia/métodos , Braquiterapia/normas , Neoplasias da Mama/radioterapia , Feminino , Humanos , Oncologia/educação , Neoplasias/radioterapia , Segurança do Paciente , Seleção de Pacientes , Radioterapia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Planejamento da Radioterapia Assistida por Computador/normas , Neoplasias Cutâneas/radioterapia , Sociedades Médicas , Estados Unidos
13.
J Contemp Brachytherapy ; 8(5): 441-447, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27895687

RESUMO

The Valencia applicators (Nucletron, an Elekta company, Elekta AB, Stockholm, Sweden) are cup-shaped tungsten applicators with a flattening filter used to collimate the radiation produced by a high-dose-rate (HDR) 192Ir source, and provide a homogeneous absorbed dose at a given depth. This beam quality provides a good option for the treatment of skin lesions at shallow depth (3-4 mm). The user must perform commissioning and periodic testing of these applicators to guarantee the proper and safe delivery of the intended absorbed dose, as recommended in the standards in radiation oncology. In this study, based on AAPM and GEC-ESTRO guidelines for brachytherapy units and our experience, a set of tests for the commissioning and periodic testing of the Valencia applicators is proposed. These include general considerations, verification of the manufacturer documentation and physical integrity, evaluation of the source-to-indexer distance and reproducibility, setting the library plan in the treatment planning system, evaluation of flatness and symmetry, absolute output and percentage depth dose verification, independent calculation of the treatment time, and visual inspection of the applicator before each treatment. For each test, the proposed methodology, equipment, frequency, expected results, and tolerance levels (when applicable) are provided.

14.
Med Phys ; 43(6): 3178-3205, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27277063

RESUMO

Although a multicenter, Phase III, prospective, randomized trial is the gold standard for evidence-based medicine, it is rarely used in the evaluation of innovative devices because of many practical and ethical reasons. It is usually sufficient to compare the dose distributions and dose rates for determining the equivalence of the innovative treatment modality to an existing one. Thus, quantitative evaluation of the dosimetric characteristics of innovative radiotherapy devices or applications is a critical part in which physicists should be actively involved. The physicist's role, along with physician colleagues, in this process is highlighted for innovative brachytherapy devices and applications and includes evaluation of (1) dosimetric considerations for clinical implementation (including calibrations, dose calculations, and radiobiological aspects) to comply with existing societal dosimetric prerequisites for sources in routine clinical use, (2) risks and benefits from a regulatory and safety perspective, and (3) resource assessment and preparedness. Further, it is suggested that any developed calibration methods be traceable to a primary standards dosimetry laboratory (PSDL) such as the National Institute of Standards and Technology in the U.S. or to other PSDLs located elsewhere such as in Europe. Clinical users should follow standards as approved by their country's regulatory agencies that approved such a brachytherapy device. Integration of this system into the medical source calibration infrastructure of secondary standard dosimetry laboratories such as the Accredited Dosimetry Calibration Laboratories in the U.S. is encouraged before a source is introduced into widespread routine clinical use. The American Association of Physicists in Medicine and the Groupe Européen de Curiethérapie-European Society for Radiotherapy and Oncology (GEC-ESTRO) have developed guidelines for the safe and consistent application of brachytherapy using innovative devices and applications. The current report covers regulatory approvals, calibration, dose calculations, radiobiological issues, and overall safety concerns that should be addressed during the commissioning stage preceding clinical use. These guidelines are based on review of requirements of the U.S. Nuclear Regulatory Commission, U.S. Department of Transportation, International Electrotechnical Commission Medical Electrical Equipment Standard 60601, U.S. Food and Drug Administration, European Commission for CE Marking (Conformité Européenne), and institutional review boards and radiation safety committees.

15.
J Contemp Brachytherapy ; 8(6): 518-524, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28115958

RESUMO

PURPOSE: Esteya® (Nucletron, an Elekta company, Elekta AB, Stockholm, Sweden) is an electronic brachytherapy device used for skin cancer lesion treatment. In order to establish an adequate level of quality of treatment, a risk analysis of the Esteya treatment process has been done, following the methodology proposed by the TG-100 guidelines of the American Association of Physicists in Medicine (AAPM). MATERIAL AND METHODS: A multidisciplinary team familiar with the treatment process was formed. This team developed a process map (PM) outlining the stages, through which a patient passed when subjected to the Esteya treatment. They identified potential failure modes (FM) and each individual FM was assessed for the severity (S), frequency of occurrence (O), and lack of detection (D). A list of existing quality management tools was developed and the FMs were consensually reevaluated. Finally, the FMs were ranked according to their risk priority number (RPN) and their S. RESULTS: 146 FMs were identified, 106 of which had RPN ≥ 50 and 30 had S ≥ 7. After introducing the quality management tools, only 21 FMs had RPN ≥ 50. The importance of ensuring contact between the applicator and the surface of the patient's skin was emphasized, so the setup was reviewed by a second individual before each treatment session with periodic quality control to ensure stability of the applicator pressure. Some of the essential quality management tools are already being implemented in the installation are the simple templates for reproducible positioning of skin applicators, that help marking the treatment area and positioning of X-ray tube. CONCLUSIONS: New quality management tools have been established as a result of the application of the failure modes and effects analysis (FMEA) treatment. However, periodic update of the FMEA process is necessary, since clinical experience has suggested occurring of further new possible potential failure modes.

16.
J Appl Clin Med Phys ; 16(5): 14­34, 2015 09 08.
Artigo em Inglês | MEDLINE | ID: mdl-26699330

RESUMO

The American Association of Physicists in Medicine (AAPM) is a nonprofit professional society whose primary purposes are to advance the science, education and professional practice of medical physics. The AAPM has more than 8,000 members and is the principal organization of medical physicists in the United States. The AAPM will periodically define new practice guidelines for medical physics practice to help advance the science of medical physics and to improve the quality of service to patients throughout the United States. Existing medical physics practice guidelines will be reviewed for the purpose of revision or renewal, as appropriate, on their fifth anniversary or sooner. Each medical physics practice guideline represents a policy statement by the AAPM, has undergone a thorough consensus process in which it has been subjected to extensive review, and requires the approval of the Professional Council. The medical physics practice guidelines recognize that the safe and effective use of diagnostic and therapeutic radiology requires specific training, skills, and techniques, as described in each document. Reproduction or modification of the published practice guidelines and technical standards by those entities not providing these services is not authorized. The following terms are used in the AAPM practice guidelines:• Must and Must Not: Used to indicate that adherence to the recommendation is considered necessary to conform to this practice guideline.• Should and Should Not: Used to indicate a prudent practice to which exceptions may occasionally be made in appropriate circumstances.


Assuntos
Elétrons , Física Médica/normas , Fótons , Neoplasias da Próstata/radioterapia , Garantia da Qualidade dos Cuidados de Saúde/normas , Radioterapia (Especialidade)/normas , Planejamento da Radioterapia Assistida por Computador/normas , Humanos , Masculino , Guias de Prática Clínica como Assunto , Dosagem Radioterapêutica , Estados Unidos
17.
Brachytherapy ; 14(6): 840-58, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26319367

RESUMO

PURPOSE: Nonmelanoma skin cancers (NMSCs) are the most common type of human malignancy. Although surgical techniques are the standard treatment, radiation therapy using photons, electrons, and brachytherapy (BT) (radionuclide-based and electronic) has been an important mode of treatment in specific clinical situations. The purpose of this work is to provide a clinical and dosimetric summary of the use of BT for the treatment of NMSC and to describe the different BT approaches used in treating cutaneous malignancies. METHODS AND MATERIALS: A group of experts from the fields of radiation oncology, medical physics, and dermatology, who specialize in managing cutaneous malignancies reviewed the literature and compiled their clinical experience regarding the clinical and dosimetric aspects of skin BT. RESULTS: A dosimetric and clinical review of both high dose rate ((192)Ir) and electronic BT treatment including surface, interstitial, and custom mold applicators is given. Patient evaluation tools such as staging, imaging, and patient selection criteria are discussed. Guidelines for clinical and dosimetric planning, appropriate margin delineation, and applicator selection are suggested. Dose prescription and dose fractionation schedules, as well as prescription depth are discussed. Commissioning and quality assurance requirements are also outlined. CONCLUSIONS: Given the limited published data for skin BT, this article is a summary of the limited literature and best practices currently in use for the treatment of NMSC.


Assuntos
Braquiterapia/métodos , Carcinoma Basocelular/radioterapia , Carcinoma de Células Escamosas/radioterapia , Neoplasias Cutâneas/radioterapia , Sociedades Médicas , Braquiterapia/instrumentação , Carcinoma Basocelular/patologia , Carcinoma de Células Escamosas/patologia , Fracionamento da Dose de Radiação , Humanos , Seleção de Pacientes , Guias de Prática Clínica como Assunto , Garantia da Qualidade dos Cuidados de Saúde , Neoplasias Cutâneas/patologia , Estados Unidos
18.
J Contemp Brachytherapy ; 7(2): 189-95, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26034501

RESUMO

A new electronic brachytherapy unit from Elekta, called Esteya(®), has recently been introduced to the market. As a part of the standards in radiation oncology, an acceptance testing and commissioning must be performed prior to treatment of the first patient. In addition, a quality assurance program should be implemented. A complete commissioning and periodic testing of the Esteya(®) device using the American Association of Physicists in Medicine (AAPM), Groupe Européen de Curiethérapie and the European Society for Radiotherapy & Oncology (GEC-ESTRO) guidelines for linacs and brachytherapy units as well as our personal experience is described in this paper. In addition to the methodology, recommendations on equipment required for each test are provided, taking into consideration their availability and traceability of the detectors. Finally, tolerance levels for all the tests are provided, and a specific frequency for each test is suggested.

19.
J Contemp Brachytherapy ; 6(2): 167-72, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25097557

RESUMO

PURPOSE: Radiotherapy (RT) has played a significant role in treating non melanoma skin cancer (NMSC). High-dose-rate brachytherapy (HDR-BT) approaches have a paramount relevance due to their adaptability, patient protection, and variable dose fractionation schedules. Several innovative applicators have been introduced to the brachytherapy community. The Valencia applicator is a new superficial device that improves the dose distribution compared with the Leipzig applicator. The purpose of this work is to assess the tumor control, cosmesis, and toxicity in patients with NMSC treated with the Valencia applicator and a new regimen of hypofractionation. MATERIAL AND METHODS: From January 2008 to March 2010, 32 patients with 45 NMSC lesions were treated with the Valencia applicator in the Hospital La Fe. The gross tumor volume was visually assessed, but the tumor depth was evaluated using ultrasound imaging. All lesions for the selected cases were limited to 4 mm depth. The prescription dose was 42 Gy in 6 or 7 fractions (biologically effective dose [BED] ≈ 70 Gy), delivered twice a week. RESULTS: Ninety-eight percent of the lesions were locally controlled at 47 months from treatment. Ninety-three percent of patients were out at least 36 months from treatment. The treatment was well tolerated in all cases. The highest skin toxicity was grade 1 RTOG/EORTC, having resolved with topical treatment at 4 weeks in all but one case which required 2 months. There were no grade 2 or higher late adverse events. CONCLUSIONS: In patients with superficial basal cell carcinoma lesions less than 25 mm in maximum diameter, HDRBT treatment with the Valencia applicator using a hypofractionated regimen provides excellent results, for both cosmetic and local control at a minimum of 3 years follow-up. Moreover, the shorter hypofractionated regimen facilitates compliance, which is very relevant for the elderly patients in our series. Valencia applicators offer a simple, safe, quick, and attractive nonsurgical treatment option.

20.
Brachytherapy ; 12(5): 495-9, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23466358

RESUMO

PURPOSE: To analyze the clinical outcome of Kaposi sarcoma skin lesions treated with high-dose-rate (HDR) brachytherapy in patients with a minimum of 2 years of followup. METHODS AND MATERIALS: Between February 2006 and July 2008, all patients with Kaposi sarcoma who received (192)Ir HDR brachytherapy using a skin surface applicator were evaluated for clinical response. Responses to treatment and toxicity were scored using standard criteria. RESULTS: Sixteen cases were collected. Treatment was delivered in four to six fractions, over a period of approximately 12 days. The specified dose ranged from 24 to 35Gy. Median followup the lesion was 41.4 months. No lesion was greater than 2cm. All patients had a complete response to treatment, with no evidence of local recurrence or tumor progression. Thirteen lesions developed Grade 1 and two lesions had Grade 2 acute skin reactions. One patient developed late skin changes with telangiectasias and hypopigmentation. CONCLUSIONS: HDR brachytherapy treatment seems to be an effective noninvasive option for patients with small cutaneous Kaposi sarcoma lesions, delivering excellent cosmesis and local control in our small series. Fewer fractions over a shorter period used in our group offer patients more convenience compared with other common regimens. Although HDR is being used more frequently for many surface applications, additional clinical studies with larger numbers of patients and longer followup are needed to confirm the general impression that it is an excellent option for many patients.


Assuntos
Braquiterapia/métodos , Sarcoma de Kaposi/radioterapia , Neoplasias Cutâneas/radioterapia , Pele/efeitos da radiação , Idoso , Idoso de 80 Anos ou mais , Biópsia , Relação Dose-Resposta à Radiação , Feminino , Seguimentos , Humanos , Masculino , Recidiva Local de Neoplasia/radioterapia , Radioterapia de Alta Energia , Estudos Retrospectivos , Pele/patologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA