Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 69
Filtrar
1.
Access Microbiol ; 6(2)2024.
Artigo em Inglês | MEDLINE | ID: mdl-38482357

RESUMO

Severe acute respiratory syndrome (SARS) coronavirus 2 (SARS-CoV-2) is a novel human coronavirus that was identified in 2019. SARS-CoV-2 infection results in an acute, severe respiratory disease called coronavirus disease 2019 (COVID-19). The emergence and rapid spread of SARS-CoV-2 has led to a global public health crisis, which continues to affect populations across the globe. Real time reverse transcription polymerase chain reaction (rRT-PCR) is the reference standard test for COVID-19 diagnosis. Serological tests are valuable tools for serosurveillance programs and establishing correlates of protection from disease. This study evaluated the performance of one in-house enzyme linked immunosorbent assay (ELISA) utilizing the pre-fusion stabilized ectodomain of SARS-CoV-2 spike (S), two commercially available chemiluminescence assays Ortho VITROS Immunodiagnostic Products Anti-SARS-CoV-2 Total Reagent Pack and Abbott SARS-CoV-2 IgG assay and one commercially available Surrogate Virus Neutralization Test (sVNT), GenScript USA Inc., cPass SARS-CoV-2 Neutralization Antibody Detection Kit for the detection of SARS-CoV-2 specific antibodies. Using a panel of rRT-PCR confirmed COVID-19 patients' sera and a negative control group as a reference standard, all three immunoassays demonstrated high comparable positivity rates and low discordant rates. All three immunoassays were highly sensitive with estimated sensitivities ranging from 95.4-96.6 %. ROC curve analysis indicated that all three immunoassays had high diagnostic accuracies with area under the curve (AUC) values ranging from 0.9698 to 0.9807. High positive correlation was demonstrated among the conventional microneutralization test (MNT) titers and the sVNT inhibition percent values. Our study indicates that independent evaluations are necessary to optimize the overall utility and the interpretation of the results of serological tests. Overall, we demonstrate that all serological tests evaluated in this study are suitable for the detection of SARS-CoV-2 antibodies.

2.
Clin Infect Dis ; 76(9): 1678-1680, 2023 05 03.
Artigo em Inglês | MEDLINE | ID: mdl-36645722

RESUMO

Human immunodeficiency virus (HIV) self-testing has emerged as a tool to increase the proportion of people to know their status. Since the first HIV self-test was approved in 2012 by the US Food and Drug Administration (FDA), global access to HIV self-tests has been bolstered by public-private partnerships to ensure equitable access in low- and middle-income countries. However, no company has applied for FDA clearance in a decade. We highlight the potential benefits to reclassifying HIV self-tests from class III to class II.


Assuntos
Infecções por HIV , Humanos , Estados Unidos , Infecções por HIV/diagnóstico , Infecções por HIV/epidemiologia , Autoteste , Programas de Rastreamento , HIV
4.
Am J Trop Med Hyg ; 107(2): 260-267, 2022 08 17.
Artigo em Inglês | MEDLINE | ID: mdl-35895418

RESUMO

Serosurveillance can provide estimates of population-level exposure to infectious pathogens and has been used extensively during the COVID-19 pandemic. Simultaneous, serological testing for multiple pathogens can be done using bead-based immunoassays to add value to disease-specific serosurveys. We conducted a validation of four SARS-CoV-2 antigens-full-length spike protein, two receptor binding domain proteins, and the nucleocapsid protein-on our existing multiplex bead assay (MBA) for enteric diseases, malaria, and vaccine preventable diseases. After determining the optimal conditions for coupling the antigens to microsphere beads, the sensitivity and specificity of the assay were determined on two instruments (Luminex-200 and MAGPIX) when testing singly (monoplex) versus combined (multiplex). Sensitivity was assessed using plasma from 87 real-time reverse transcription polymerase chain reaction (rRT-PCR) positive persons collected in March-May of 2020 and ranged from 94.3% to 96.6% for the different testing conditions. Specificity was assessed using 98 plasma specimens collected prior to December 2019 and plasma from 19 rRT-PCR negative persons and ranged from 97.4% to 100%. The positive percent agreement was 93.8% to 97.9% using 48 specimens collected > 21 days post-symptom onset, while the negative percent agreement was ≥ 99% for all antigens. Test performance was similar using monoplex or multiplex testing. Integrating SARS-CoV-2 serology with other diseases of public health interest could add significant value to public health programs that have suffered severe programmatic setbacks during the COVID-19 pandemic.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , COVID-19/diagnóstico , COVID-19/epidemiologia , Pandemias , Sensibilidade e Especificidade , Imunoensaio
5.
Microbiol Spectr ; 10(1): e0156421, 2022 02 23.
Artigo em Inglês | MEDLINE | ID: mdl-35019677

RESUMO

The emergence of SARS-CoV-2 created a crucial need for serology assays to detect anti-SARS-CoV-2 antibodies, which led to many serology assays entering the market. A trans-government collaboration was created in April 2020 to independently evaluate the performance of commercial SARS-CoV-2 serology assays and help inform U.S. Food and Drug Administration (FDA) regulatory decisions. To assess assay performance, three evaluation panels with similar antibody titer distributions were assembled. Each panel consisted of 110 samples with positive (n = 30) serum samples with a wide range of anti-SARS-CoV-2 antibody titers and negative (n = 80) plasma and/or serum samples that were collected before the start of the COVID-19 pandemic. Each sample was characterized for anti-SARS-CoV-2 antibodies against the spike protein using enzyme-linked immunosorbent assays (ELISA). Samples were selected for the panel when there was agreement on seropositivity by laboratories at National Cancer Institute's Frederick National Laboratory for Cancer Research (NCI-FNLCR) and Centers for Disease Control and Prevention (CDC). The sensitivity and specificity of each assay were assessed to determine Emergency Use Authorization (EUA) suitability. As of January 8, 2021, results from 91 evaluations were made publicly available (https://open.fda.gov/apis/device/covid19serology/, and https://www.cdc.gov/coronavirus/2019-ncov/covid-data/serology-surveillance/serology-test-evaluation.html). Sensitivity ranged from 27% to 100% for IgG (n = 81), from 10% to 100% for IgM (n = 74), and from 73% to 100% for total or pan-immunoglobulins (n = 5). The combined specificity ranged from 58% to 100% (n = 91). Approximately one-third (n = 27) of the assays evaluated are now authorized by FDA for emergency use. This collaboration established a framework for assay performance evaluation that could be used for future outbreaks and could serve as a model for other technologies. IMPORTANCE The SARS-CoV-2 pandemic created a crucial need for accurate serology assays to evaluate seroprevalence and antiviral immune responses. The initial flood of serology assays entering the market with inadequate performance emphasized the need for independent evaluation of commercial SARS-CoV-2 antibody assays using performance evaluation panels to determine suitability for use under EUA. Through a government-wide collaborative network, 91 commercial SARS-CoV-2 serology assay evaluations were performed. Three evaluation panels with similar overall antibody titer distributions were assembled to evaluate performance. Nearly one-third of the assays evaluated met acceptable performance recommendations, and two assays had EUAs revoked and were removed from the U.S. market based on inadequate performance. Data for all serology assays evaluated are available at the FDA and CDC websites (https://open.fda.gov/apis/device/covid19serology/, and https://www.cdc.gov/coronavirus/2019-ncov/covid-data/serology-surveillance/serology-test-evaluation.html).


Assuntos
Anticorpos Antivirais/sangue , Teste Sorológico para COVID-19/métodos , COVID-19/sangue , Ensaio de Imunoadsorção Enzimática/métodos , SARS-CoV-2/imunologia , COVID-19/diagnóstico , COVID-19/epidemiologia , COVID-19/virologia , Aprovação de Teste para Diagnóstico , Humanos , Laboratórios , Pandemias , SARS-CoV-2/genética , Sensibilidade e Especificidade , Glicoproteína da Espícula de Coronavírus/análise , Glicoproteína da Espícula de Coronavírus/imunologia , Estados Unidos/epidemiologia , United States Food and Drug Administration
6.
Sci Rep ; 11(1): 12330, 2021 06 10.
Artigo em Inglês | MEDLINE | ID: mdl-34112850

RESUMO

SARS-CoV-2 emerged in late 2019 and has since spread around the world, causing a pandemic of the respiratory disease COVID-19. Detecting antibodies against the virus is an essential tool for tracking infections and developing vaccines. Such tests, primarily utilizing the enzyme-linked immunosorbent assay (ELISA) principle, can be either qualitative (reporting positive/negative results) or quantitative (reporting a value representing the quantity of specific antibodies). Quantitation is vital for determining stability or decline of antibody titers in convalescence, efficacy of different vaccination regimens, and detection of asymptomatic infections. Quantitation typically requires two-step ELISA testing, in which samples are first screened in a qualitative assay and positive samples are subsequently analyzed as a dilution series. To overcome the throughput limitations of this approach, we developed a simpler and faster system that is highly automatable and achieves quantitation in a single-dilution screening format with sensitivity and specificity comparable to those of ELISA.


Assuntos
Anticorpos Antivirais/sangue , COVID-19/sangue , SARS-CoV-2/isolamento & purificação , Animais , Anticorpos Antivirais/imunologia , COVID-19/diagnóstico , COVID-19/imunologia , Teste Sorológico para COVID-19/economia , Teste Sorológico para COVID-19/métodos , Ensaio de Imunoadsorção Enzimática/economia , Ensaio de Imunoadsorção Enzimática/métodos , Humanos , Imunoglobulina G/sangue , Imunoglobulina G/imunologia , Imunoglobulina M/sangue , Imunoglobulina M/imunologia , Camundongos , SARS-CoV-2/imunologia
7.
BMC Infect Dis ; 21(1): 423, 2021 May 05.
Artigo em Inglês | MEDLINE | ID: mdl-33952212

RESUMO

BACKGROUND: In the US, one in six men who have sex with men (MSM) with HIV are unaware of their HIV infection. In certain circumstances, access to HIV testing and viral load (VL) monitoring is challenging. The objective of this study was to evaluate the feasibility of conducting laboratory-based HIV and antiretroviral (ARV) drug testing, and VL monitoring as part of two studies on self-collected dried blood spots (DBS). METHODS: Participants were instructed to collect DBS by self-fingerstick in studies that enrolled MSM online. DBS from the first study (N = 1444) were tested with HIV serological assays approved by the Food and Drug Administration (FDA). A subset was further tested with laboratory-modified serological and VL assays, and ARV levels were measured by mass spectrometry. DBS from the second study (N = 74) were only tested to assess VL monitoring. RESULTS: In the first study, the mail back rate of self-collected DBS cards was 62.9%. Ninety percent of DBS cards were received at the laboratory within 2 weeks from the day of collection, and 98% of the cards had sufficient spots for one assay. Concordance between FDA-approved and laboratory-modified protocols was high. The samples with undetectable ARV had higher VL than samples with at least one ARV drug. In the second study, 70.3% participants returned self-collected DBS cards, and all had sufficient spots for VL assay. High VL was observed in samples from participants who reported low ARV adherence. CONCLUSIONS: In these studies, MSM were able to collect and provide adequate DBS for HIV testing. The FDA-approved and laboratory-modified testing algorithms performed similarly. DBS collected at home may be feasible for HIV testing, ARV measurement, and monitoring viral suppression.


Assuntos
Fármacos Anti-HIV/uso terapêutico , Teste em Amostras de Sangue Seco/métodos , Infecções por HIV/virologia , Autoteste , Carga Viral/métodos , Adulto , Fármacos Anti-HIV/farmacologia , Estudos de Viabilidade , Infecções por HIV/diagnóstico , Infecções por HIV/tratamento farmacológico , Homossexualidade Masculina , Humanos , Masculino , Adesão à Medicação , Minorias Sexuais e de Gênero , Estados Unidos
8.
JAMA Intern Med ; 2020 Jul 21.
Artigo em Inglês | MEDLINE | ID: mdl-32692365

RESUMO

IMPORTANCE: Reported cases of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection likely underestimate the prevalence of infection in affected communities. Large-scale seroprevalence studies provide better estimates of the proportion of the population previously infected. OBJECTIVE: To estimate prevalence of SARS-CoV-2 antibodies in convenience samples from several geographic sites in the US. DESIGN, SETTING, AND PARTICIPANTS: This cross-sectional study performed serologic testing on a convenience sample of residual sera obtained from persons of all ages. The serum was collected from March 23 through May 12, 2020, for routine clinical testing by 2 commercial laboratory companies. Sites of collection were San Francisco Bay area, California; Connecticut; south Florida; Louisiana; Minneapolis-St Paul-St Cloud metro area, Minnesota; Missouri; New York City metro area, New York; Philadelphia metro area, Pennsylvania; Utah; and western Washington State. EXPOSURES: Infection with SARS-CoV-2. MAIN OUTCOMES AND MEASURES: The presence of antibodies to SARS-CoV-2 spike protein was estimated using an enzyme-linked immunosorbent assay, and estimates were standardized to the site populations by age and sex. Estimates were adjusted for test performance characteristics (96.0% sensitivity and 99.3% specificity). The number of infections in each site was estimated by extrapolating seroprevalence to site populations; estimated infections were compared with the number of reported coronavirus disease 2019 (COVID-19) cases as of last specimen collection date. RESULTS: Serum samples were tested from 16 025 persons, 8853 (55.2%) of whom were women; 1205 (7.5%) were 18 years or younger and 5845 (36.2%) were 65 years or older. Most specimens from each site had no evidence of antibodies to SARS-CoV-2. Adjusted estimates of the proportion of persons seroreactive to the SARS-CoV-2 spike protein antibodies ranged from 1.0% in the San Francisco Bay area (collected April 23-27) to 6.9% of persons in New York City (collected March 23-April 1). The estimated number of infections ranged from 6 to 24 times the number of reported cases; for 7 sites (Connecticut, Florida, Louisiana, Missouri, New York City metro area, Utah, and western Washington State), an estimated greater than 10 times more SARS-CoV-2 infections occurred than the number of reported cases. CONCLUSIONS AND RELEVANCE: During March to early May 2020, most persons in 10 diverse geographic sites in the US had not been infected with SARS-CoV-2 virus. The estimated number of infections, however, was much greater than the number of reported cases in all sites. The findings may reflect the number of persons who had mild or no illness or who did not seek medical care or undergo testing but who still may have contributed to ongoing virus transmission in the population.

9.
J Clin Virol ; 129: 104479, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32531665

RESUMO

BACKGROUND: Currently, FDA-approved HIV-1 viral load (VL) assays use venipuncture-derived plasma. The Hologic Panther system uses 0.7 mL total volume for the Aptima HIV-1 Quant Assay standard (APT-Quant-std) and dilution (APT-Quant-dil) protocols. However, smaller plasma volumes from fingerstick whole blood (FSB) collected in EDTA-microtainer tubes (MCT) could provide an easier sample collection method for HIV-1 VL testing. OBJECTIVES: To evaluate the performance of the APT-Quant-std compared to the Roche CAP/CTM and Abbott m2000RT VL assays and an alternative APTQuant 1:7 dilution protocol, the latter using 100 µL of MCT-derived plasma from FSB. STUDY DESIGN: Linearity was determined using commercial HIV-1 RNA plasma controls. Dilutions ranging 1.56-2.95 log10 copies/mL were prepared to determine the APT-Quant-dil Limit of Quantitation (LOQ) using Probit analysis. Specificity of APT-Quant-std was calculated using 326 HIVnegative samples. To evaluate agreement, 329 plasma specimens were tested with APT-Quant-std, CAP/CTM, and m2000RT. Forty-seven matched venipuncture and MCT-derived plasma specimens were tested with APT-Quant-std and APT-Quant-dil. RESULTS: Among the RNA controls, specificity was 99.69 % for APT-Quant-std. The R2 values were 0.988 (APT-Quant-std/CAP/CTM), 0.980 (APT-Quant-std/ m2000RT), and 0.997 (APT-Quant-std/APT-Quant-dil). The APT-Quant-dil LOQ was estimated at 2.7 log10 copies/mL (500 copies/mL) (95 %CI 2.62-2.87). At 2.3 log10 copies/mL (200 copies/mL), the overall agreement was 91.0 % for APT-Quant-std/CAP/CTM, 85.7 % for APT-Quant-std/m2000RT, and 82.9 % for APT-Quant-std/APT-Quant-dil. Quantified APT-Quant-std results were on average 0.2 log10 copies/mL higher than CAP/CTM and m2000RT and 0.14 log10 copies/mL higher than APT-Quant-dil. CONCLUSION: APT-Quant showed similar performance compared to the CAP/CTM and m2000RT assays and remains sensitive and accurate using the dilution protocol.


Assuntos
Infecções por HIV , HIV-1 , Infecções por HIV/diagnóstico , HIV-1/genética , Humanos , RNA , RNA Viral/genética , Sensibilidade e Especificidade , Carga Viral
10.
MMWR Morb Mortal Wkly Rep ; 69(3): 63-66, 2020 Jan 24.
Artigo em Inglês | MEDLINE | ID: mdl-31971928

RESUMO

Since 2014, the recommended laboratory testing algorithm for diagnosing human immunodeficiency virus (HIV) infection has included a supplemental HIV-1/HIV-2 differentiation test to confirm infection type on the basis of the presence of type-specific antibodies (1). Correctly identifying HIV-1 and HIV-2 infections is vital because their epidemiology and clinical management differ. To describe the percentage of diagnoses for which an HIV-1/HIV-2 differentiation test result was reported and to categorize HIV type based on laboratory test results, 2010-2017 data from CDC's National HIV Surveillance System (NHSS) were analyzed. During 2010-2017, a substantial increase in the number of HIV-1/HIV-2 differentiation test results were reported to NHSS, consistent with implementation of the HIV laboratory-based testing algorithm recommended in 2014. However, >99.9% of all HIV infections identified in the United States were categorized as HIV-1, and the number of HIV-2 diagnoses (mono-infection or dual-infection) remained extremely low (<0.03% of all HIV infections). In addition, the overall number of false positive HIV-2 test results produced by the HIV-1/HIV-2 differentiation increased. The diagnostic value of a confirmatory antibody differentiation test in a setting with sensitive and specific screening tests and few HIV-2 infections might be limited. Evaluation and consideration of other HIV tests approved by the Food and Drug Administration (FDA) that might increase efficiencies in the CDC and Association of Public Health Laboratories-recommended HIV testing algorithm are warranted.


Assuntos
Testes Diagnósticos de Rotina/métodos , Infecções por HIV/diagnóstico , Infecções por HIV/virologia , HIV-2/isolamento & purificação , Adolescente , Adulto , Algoritmos , Centers for Disease Control and Prevention, U.S. , Feminino , Infecções por HIV/epidemiologia , Humanos , Laboratórios , Masculino , Pessoa de Meia-Idade , Estados Unidos/epidemiologia , Adulto Jovem
11.
Sex Transm Dis ; 47(5S Suppl 1): S26-S31, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-31977972

RESUMO

BACKGROUND: There is benefit to early HIV-1 diagnosis and treatment, but there is no Food and Drug Administration-approved quantitative assay with a diagnostic claim. We compared the performance of the Hologic Aptima HIV-1 Quant (APT-Quant) and Aptima HIV-1 Qual (APT-Qual) assays for diagnostic use and the performance of a diagnostic algorithm consisting of Bio-Rad BioPlex 2200 HIV Ag-Ab assay (BPC) followed by APT-Quant (2-test) compared with BPC followed by Geenius HIV-1/2 supplemental assay (Geenius) with reflex to APT-Qual (3-test). METHODS: Five hundred twenty-four plasma, which included 419 longitudinal specimens from HIV-1 seroconverters (78 were after initiating antiretroviral therapy [ART]) and 105 from ART-naive persons with established HIV-1 infections, were used to evaluate APT-Quant performance for diagnostic use. Specimens from 200 HIV-negative persons were used to measure specificity. For the algorithm comparison, BPC-reactive specimens were evaluated with the 2-test or 3-test algorithm. McNemar's test was used to compare performance. RESULTS: The APT-Quant detected more samples early in infection compared with APT-Qual. The APT-Quant specificity was 99.8%. Before ART initiation, the algorithms performed similarly among samples from different stages of infection. After ART initiation, the 3-test algorithm performed significantly better (P = 0.0233). CONCLUSIONS: The APT-Quant has excellent performance for diagnostic use. The 2-test algorithm works well in ART-naive samples, but its performance decreases after the IgG response is elicited and with ART-induced suppressed viremia. Providing confirmation and viral load assay with 1 test result could be advantageous for patient care. However, additional factors and challenges associated with the implementation of this 2-test algorithm, such as cost, specimen type, and collection need further evaluation.


Assuntos
Anticorpos Anti-HIV/sangue , Infecções por HIV/sangue , HIV-1/isolamento & purificação , Técnicas de Amplificação de Ácido Nucleico/normas , RNA Viral/sangue , Kit de Reagentes para Diagnóstico/normas , Carga Viral/métodos , Algoritmos , Infecções por HIV/diagnóstico , Infecções por HIV/tratamento farmacológico , HIV-1/genética , Humanos , Reação em Cadeia da Polimerase/métodos , RNA Viral/genética , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
12.
Sex Transm Dis ; 47(5S Suppl 1): S18-S25, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-31895304

RESUMO

BACKGROUND: Since 2014, the recommended algorithm for laboratory diagnosis of HIV infection in the United States has consisted of an HIV-1/2 antigen/antibody (Ag/Ab) test followed by an HIV-1/2 antibody (Ab) differentiation test and, if necessary, a diagnostic HIV-1 nucleic acid test to resolve discordant or indeterminate results. METHODS: Using stored specimens from persons seeking HIV testing who had not received a previous diagnosis or treatment, we compared the performance of a 3-step alternative algorithm consisting of an Ag/Ab test followed by a quantitative HIV-1 RNA viral load assay and, if viral load is not detected, an Ab differentiation test, to that of the recommended algorithm. We calculated the sensitivity and specificity of 5 Ag/Ab tests and the proportion of specimens correctly classified by the alternative algorithm compared with the recommended algorithm. Results were examined separately for specimens classified as early infection, established infection, and false-reactive screening. RESULTS: Sensitivity and specificity were similar among all Ag/Ab tests. Viral load quantification correctly classified all specimens from early infection, all false-reactive screening specimens, and the majority of specimens from established infection. CONCLUSIONS: Although cost, regulatory barriers, test availability, and the ability to differentiate early from established infection must be considered, this alternative algorithm can potentially decrease the total number of tests performed and reduce turnaround time, thereby streamlining HIV diagnosis and initiation of treatment.


Assuntos
Anticorpos Anti-HIV/sangue , Infecções por HIV/diagnóstico , HIV-1/genética , HIV-1/isolamento & purificação , Laboratórios/normas , RNA Viral/genética , Algoritmos , HIV-1/imunologia , HIV-2/genética , HIV-2/imunologia , HIV-2/isolamento & purificação , Humanos , Imunoensaio , Valor Preditivo dos Testes , Sensibilidade e Especificidade , Estados Unidos , Carga Viral
13.
J Clin Virol ; 122: 104214, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31835210

RESUMO

BACKGROUND: Cepheid's Xpert HIV-1 Viral Load (Xpert VL), a simplified, automated, single-use quantitative assay used with the GeneXpert System, is not FDA approved. OBJECTIVES: Using stored plasma, we conducted a study to assess the ability of Xpert VL to quantify viral load relative to the Roche COBAS AmpliPrep/COBAS TaqMan HIV-1 (Cobas VL) and to examine the use of the Xpert VL as a qualitative diagnostic test. STUDY DESIGN: Following HIV-1 viral stock dilutions, we conducted a probit analysis to identify the concentration where 95 % of specimens had quantified VLs. We also examined Xpert and Cobas log VL correlation in linearity panels; compared the proportion of 220 seroconverter specimens with virus detected using McNemar's test; and tested specimens from persons with untreated, established HIV-1 infection (n=149) and uninfected persons (n=497). Furthermore, we examined Xpert VL as a qualitative test in seroconverter specimens with early (n=20) and later (n=68) acute infections. RESULTS: At 1.80 log10 copies/mL, 95 % of specimens had quantifiable virus using Xpert VL. Xpert and Cobas VLs were highly correlated (R2=0.994). The proportion of seroconverter specimens with virus detected using Cobas and with Xpert VL was not statistically different (p=0.0578). Xpert VL detected 97.9 % of established infections, and specificity was 99.80 % (95 % CI 98.87%-99.99%). Xpert VL detected 90 % and 98.5 % of early and later acute infections, respectively. CONCLUSIONS: If approved, Xpert VL could allow U.S. laboratories that cannot bring on large, complex testing platforms to conduct HIV monitoring. An approval for diagnostic use may provide timely identification of HIV infections.


Assuntos
Infecções por HIV/diagnóstico , Técnicas de Amplificação de Ácido Nucleico/métodos , RNA Viral/sangue , Carga Viral/métodos , Automação Laboratorial , Infecções por HIV/sangue , Infecções por HIV/virologia , HIV-1 , Humanos , Sensibilidade e Especificidade , Manejo de Espécimes
14.
JAMA Intern Med ; 180(1): 117-125, 2020 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-31738378

RESUMO

Importance: Undiagnosed HIV infection results in delayed access to treatment and increased transmission. Self-tests for HIV may increase awareness of infection among men who have sex with men (MSM). Objective: To evaluate the effect of providing HIV self-tests on frequency of testing, diagnoses of HIV infection, and sexual risk behaviors. Design, Setting, and Participants: This 12-month longitudinal, 2-group randomized clinical trial recruited MSM through online banner advertisements from March through August 2015. Those recruited were at least 18 years of age, reported engaging in anal sex with men in the past year, never tested positive for HIV, and were US residents with mailing addresses. Participants completed quarterly online surveys. Telephone call notes and laboratory test results were included in the analysis, which was completed from August 2017 through December 2018. Interventions: All participants had access to online web-based HIV testing resources and telephone counseling on request. Participants were randomized in a 1:1 ratio to the control group or a self-testing (ST) group, which received 4 HIV self-tests after completing the baseline survey with the option to replenish self-tests after completing quarterly surveys. At study completion, all participants were offered 2 self-tests and 1 dried blood spot collection kit. Main Outcomes and Measures: Primary outcomes were HIV testing frequency (tested ≥3 times during the trial) and number of newly identified HIV infections among participants in both groups and social network members who used the study HIV self-tests. Secondary outcomes included sex behaviors (eg, anal sex, serosorting). Results: Of 2665 participants, the mean (SD) age was 30 (9.6) years, 1540 (57.8%) were white, and 443 (16.6%) had never tested for HIV before enrollment. Retention rates at each time point were more than 54%, and 1991 (74.7%) participants initiated 1 or more follow-up surveys. More ST participants reported testing 3 or more times during the trial than control participants (777 of 1014 [76.6%] vs 215 of 977 [22.0%]; P < .01). The cumulative number of newly identified infections during the trial was twice as high in the ST participants as the control participants (25 of 1325 [1.9%] vs 11 of 1340 [0.8%]; P = .02), with the largest difference in HIV infections identified in the first 3 months (12 of 1325 [0.9%] vs 2 of 1340 [0.1%]; P < .01). The ST participants reported 34 newly identified infections among social network members who used the self-tests. Conclusions and Relevance: Distribution of HIV self-tests provides a worthwhile mechanism to increase awareness of HIV infection and prevent transmission among MSM. Trial Registration: ClinicalTrials.gov identifier: NCT02067039.


Assuntos
Sorodiagnóstico da AIDS/métodos , Infecções por HIV/diagnóstico , Kit de Reagentes para Diagnóstico , Comportamento Sexual , Minorias Sexuais e de Gênero , Adolescente , Adulto , Bissexualidade , Teste em Amostras de Sangue Seco , Seleção por Sorologia para HIV , Homossexualidade Masculina , Humanos , Internet , Masculino , Programas de Rastreamento , Adulto Jovem
15.
PLoS One ; 14(5): e0217048, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31125356

RESUMO

BACKGROUND: Serological assays to determine HIV incidence have contributed to estimates of HIV incidence, monitoring of HIV spread, and evaluation of prevention strategies. Two frequently used incidence assays are the Sedia HIV-1 LAg-Avidity EIA (LAg) and the Bio-Rad avidity incidence (BRAI) assays with a mean duration of recent infection (MDRI) of 130 and 240 days for subtype B infections, respectively. Little is known about how these assays perform with recombinant HIV-1 strains. We evaluated the concordance of these assays in a population infected mainly with HIV-1 CRF06_cpx. MATERIAL/METHODS: Remnant serum samples (n = 288) collected from confirmed, newly-diagnosed HIV-positive persons from Estonia in 2013 were tested. Demographic and clinical data were extracted from clinical databases. LAg was performed according to the manufacturer's protocol and BRAI testing was done using a validated protocol. Samples with LAg-pending or BRAI-invalid results were reclassified as recent if they were from persons with viral loads <1000 copies/mL or were reclassified as long-term if presenting with AIDS. RESULTS: In total 325 new HIV infections were diagnosed in 2013 in Estonia. Of those 276 persons were tested with both LAg and BRAI. Using assay results only, the recency rate was 44% and 70% by LAg and BRAI, respectively. The majority of samples (92%) recent by LAg were recent by BRAI. Similarly, 89% of samples long-term by BRAI were long-term by LAg. After clinical information was included in the analysis, the recency rate was 44% and 62% for LAg and BRAI, respectively. The majority of samples (86%) recent by LAg were recent by BRAI and 91% of long-term infections by BRAI were long-term by LAg. CONCLUSIONS: Comparison of LAg and BRAI results in this mostly CRF06_cpx-infected population showed good concordance for incidence classification. Our finding of a higher recency rate with BRAI in this population is likely related to the longer MDRI for this assay.


Assuntos
Afinidade de Anticorpos , Antígenos HIV/imunologia , Infecções por HIV/imunologia , HIV-1/imunologia , Adulto , Epitopos , Estônia/epidemiologia , Feminino , Anticorpos Anti-HIV/imunologia , Infecções por HIV/diagnóstico , Infecções por HIV/epidemiologia , Soropositividade para HIV/imunologia , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Testes Sorológicos , Carga Viral
16.
AIDS ; 33(7): 1231-1240, 2019 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-30870196

RESUMO

OBJECTIVE: To determine the precision of new and established methods for estimating duration of HIV infection. DESIGN: A retrospective analysis of HIV testing results from serial samples in commercially available panels, taking advantage of extensive testing previously conducted on 53 seroconverters. METHODS: We initially investigated four methods for estimating infection timing: method 1, 'Fiebig stages' based on test results from a single specimen; method 2, an updated '4th gen' method similar to Fiebig stages but using antigen/antibody tests in place of the p24 antigen test; method 3, modeling of 'viral ramp-up' dynamics using quantitative HIV-1 viral load data from antibody-negative specimens; and method 4, using detailed clinical testing history to define a plausible interval and best estimate of infection time. We then investigated a 'two-step method' using data from both methods 3 and 4, allowing for test results to have come from specimens collected on different days. RESULTS: Fiebig and '4th gen' staging method estimates of time since detectable viremia had similar and modest correlation with observed data. Correlation of estimates from both new methods (3 and 4), and from a combination of these two ('two-step method') was markedly improved and variability significantly reduced when compared with Fiebig estimates on the same specimens. CONCLUSION: The new 'two-step' method more accurately estimates timing of infection and is intended to be generalizable to more situations in clinical medicine, research, and surveillance than previous methods. An online tool is now available that enables researchers/clinicians to input data related to method 4, and generate estimated dates of detectable infection.


Assuntos
Infecções por HIV/diagnóstico , Viremia/diagnóstico , Algoritmos , Anticorpos Anti-HIV/sangue , Proteína do Núcleo p24 do HIV/sangue , Infecções por HIV/sangue , HIV-1 , Humanos , Internet , Estudos Retrospectivos , Software , Tempo , Carga Viral , Viremia/sangue
17.
J Clin Virol ; 111: 24-28, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30594702

RESUMO

BACKGROUND: In the US, the HIV diagnostic algorithm for laboratory settings recommends the use of an HIV-1/HIV-2 differentiation supplemental assay after an initial reactive antigen/antibody (Ag/Ab) assay result. Since the discontinuation of the Multispot HIV-1/HIV-2 Rapid Test (MS), the Geenius HIV-1/2 Supplemental assay (Geenius) is the only FDA-approved supplemental differentiation test. OBJECTIVE: We compared the performance of Geenius to MS and Western Blot (WB). STUDY DESIGN: The relative seroconversion plasma reactivity of Geenius and MS was assessed using a 50% cumulative frequency analysis from 17 HIV-1 seroconverters. In addition, previously characterized plasma specimens, 186 HIV-1 positive, 100 HIV-2 positive, and 93 Ag/Ab-positive/HIV-1 RNA-negative, were tested with Geenius v1.1 software. McNemar's test was used for paired comparison analysis. A subset of 48 specimens were retested with the upgraded Geenius v1.3 software. RESULTS: In HIV-1 seroconverters, the relative seroconversion reactivity was 2.5 and 2 days before the first positive HIV-1 WB for Geenius and MS, respectively. In HIV-1 positive samples, Geenius performed similarly to HIV-1 WB (p=0.1687) and MS (p=0.8312). In HIV-2 positive samples, Geenius underperformed compared to HIV-2 WB (p=0.0005) and MS (p=0.0012). When using the upgraded software among the HIV-1 positive and Ag/Ab-reactive/HIV-1 RNA-negative samples, gp140 reactivity decreased without affecting characterization of HIV-2 samples. CONCLUSIONS: With HIV-1 samples, Geenius, WB and MS performance was similar as supplemental tests. The updated Geenius software reduced false gp140 reactivity, but had no impact on identifying true HIV-2 infections. Further evaluation will assess the impact of the Geenius software update on final diagnostic interpretations.


Assuntos
Cromatografia de Afinidade/normas , Infecções por HIV/virologia , HIV-1/imunologia , HIV-2/imunologia , Kit de Reagentes para Diagnóstico/normas , Software , Sorodiagnóstico da AIDS , Algoritmos , Western Blotting/métodos , Western Blotting/normas , Cromatografia de Afinidade/métodos , Reações Cruzadas , Anticorpos Anti-HIV/sangue , Infecções por HIV/sangue , Soropositividade para HIV , Humanos , Programas de Rastreamento/normas , Sensibilidade e Especificidade
18.
J Virol Methods ; 259: 60-65, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29874550

RESUMO

Real-time PCR assays for nucleic acid testing (NAT) of hepatitis viruses A-E and for HIV-1 and HIV-2 have been developed; however, a multiplex assay that can simultaneously detect all of these agents is not yet available. Standardized TaqMan assays for detection of hepatitis viruses A-E have been described and applied to TaqMan Array Cards (TAC) which are capable of multiple pathogen detection using a single set of optimized PCR conditions. Assays for three gene regions of HIV-1 (long-terminal repeat (LTR), gag, and polymerase) and HIV-2 (overlap of LTR and gag, protease and integrase) were designed using the hepatitis assay conditions. Nucleic acid extracts of HIV-1-infected samples (44 plasma, 41 whole blood, 20 HIV-1 viral stocks) were tested on the TAC cards; 98 were reactive (92%) with 70 in multiple gene regions. Twenty-four of the 27 (89%) HIV-2 specimens (10 plasma, 1 PBMC lysate, 6 whole blood and 10 plasmids containing HIV-2 polymerase) were detected on TAC. No HIV or hepatitis virus sequences were detected in 30 HIV-negative samples (specificity 100%). Three HBV and 18 HCV co-infections were identified in the HIV-1-infected specimens. Multi-pathogen detection using TAC could provide a rapid, sensitive and more efficient method of surveying for a variety of infectious disease nucleic acids.


Assuntos
Infecções por HIV/diagnóstico , HIV-1/isolamento & purificação , HIV-2/isolamento & purificação , Vírus de Hepatite/isolamento & purificação , Hepatite Viral Humana/diagnóstico , Análise em Microsséries/métodos , Reação em Cadeia da Polimerase em Tempo Real/métodos , Infecções por HIV/virologia , HIV-1/genética , HIV-2/genética , Vírus de Hepatite/genética , Hepatite Viral Humana/virologia , Sensibilidade e Especificidade , Fatores de Tempo
19.
J Virol Methods ; 255: 91-97, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29474813

RESUMO

Isothermal nucleic acid amplification techniques, such as reverse-transcription loop-mediated isothermal amplification (RT-LAMP), exhibit characteristics that are suitable for the development of a rapid, low-cost NAT that can be used at the POC. For demonstration of utility for global use, studies are needed to validate the performance of RT-LAMP for the detection of divergent subtypes. In this study, we designed and evaluated multiplexed HIV-1 integrase RT-LAMP primers to detect subtypes within group M, along with an RNase P positive internal processing and amplification control. Using a panel of 26 viral isolates representing the major circulating subtypes, we demonstrated detection of all isolates of subtypes A1, C, D, F1, F2, G, CRF01_AE, CRF02_AG, and two unique recombinant forms (URFs). A whole blood panel created with one representative isolate of each subtype was successfully amplified with the group M HIV-1 integrase and RNase P internal control primers. The group M HIV-1 RT-LAMP assay was further evaluated on 61 plasma specimens obtained from persons from Cameroon and Uganda. The sequence-conserved group M HIV-1 RT-LAMP primers, coupled to a low-cost amplification device, may improve diagnosis of acute infection at the POC and provide timely confirmation of HIV status.


Assuntos
Infecções por HIV/diagnóstico , Infecções por HIV/virologia , HIV-1/genética , Reação em Cadeia da Polimerase Multiplex , Carga Viral , Humanos , Tipagem Molecular , Reação em Cadeia da Polimerase Multiplex/métodos , Sensibilidade e Especificidade
20.
J Infect Dis ; 216(9): 1053-1062, 2017 11 27.
Artigo em Inglês | MEDLINE | ID: mdl-29029156

RESUMO

In January 2015, an outbreak of undiagnosed human immunodeficiency virus (HIV) infections among persons who inject drugs (PWID) was recognized in rural Indiana. By September 2016, 205 persons in this community of approximately 4400 had received a diagnosis of HIV infection. We report results of new approaches to analyzing epidemiologic and laboratory data to understand transmission during this outbreak. HIV genetic distances were calculated using the polymerase region. Networks were generated using data about reported high-risk contacts, viral genetic similarity, and their most parsimonious combinations. Sample collection dates and recency assay results were used to infer dates of infection. Epidemiologic and laboratory data each generated large and dense networks. Integration of these data revealed subgroups with epidemiologic and genetic commonalities, one of which appeared to contain the earliest infections. Predicted infection dates suggest that transmission began in 2011, underwent explosive growth in mid-2014, and slowed after the declaration of a public health emergency. Results from this phylodynamic analysis suggest that the majority of infections had likely already occurred when the investigation began and that early transmission may have been associated with sexual activity and injection drug use. Early and sustained efforts are needed to detect infections and prevent or interrupt rapid transmission within networks of uninfected PWID.


Assuntos
Surtos de Doenças , Infecções por HIV/genética , Infecções por HIV/transmissão , HIV-1/genética , Alcaloides Opiáceos/efeitos adversos , Abuso de Substâncias por Via Intravenosa/complicações , Adulto , Busca de Comunicante , Feminino , Infecções por HIV/epidemiologia , Humanos , Masculino , Pessoa de Meia-Idade , Comportamento Sexual , Estados Unidos/epidemiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA