Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Heart Rhythm ; 2024 May 19.
Artigo em Inglês | MEDLINE | ID: mdl-38768839

RESUMO

BACKGROUND: The safety and long-term efficacy of radiofrequency (RF) catheter ablation (CA) of paroxysmal atrial fibrillation (PAF) has been well established. Contemporary techniques to optimize ablation delivery, reduce fluoroscopy use, and improve clinical outcomes have been developed. OBJECTIVE: The purpose of this study was to assess the contemporary real-world practice approach and short and long-term outcomes of RF CA for PAF through a prospective multicenter registry. METHODS: Using the REAL-AF (Real-world Experience of Catheter Ablation for the Treatment of Symptomatic Paroxysmal and Persistent Atrial Fibrillation; ClincalTrials.gov Identifier: NCT04088071) Registry, patients undergoing RF CA to treat PAF across 42 high-volume institutions and 79 experienced operators were evaluated. The procedures were performed using zero or reduced fluoroscopy, contact force sensing catheters, wide area circumferential ablation, and ablation index as a guide with a target of 380-420 for posterior and 500-550 for anterior lesions. The primary efficacy outcome was freedom from all-atrial arrhythmia recurrence at 12 months. RESULTS: A total of 2470 patients undergoing CA from January 2018 to December 2022 were included. Mean age was 65.2 ±11.14 years, and 44% were female. Most procedures were performed without fluoroscopy (71.5%), with average procedural and total RF times of 95.4 ± 41.7 minutes and 22.1±11.8 minutes, respectively. At 1-year follow-up, freedom from all-atrial arrhythmias was 81.6% with 89.7% of these patients off antiarrhythmic drugs. No significant difference was identified comparing pulmonary vein isolation vs pulmonary vein isolation plus ablation approaches. The complication rate was 1.9%. CONCLUSION: Refinement of RF CA to treat PAF using contemporary tools, standardized protocols, and electrophysiology laboratory workflows resulted in excellent short- and long-term clinical outcomes.

2.
Ann Cardiothorac Surg ; 13(2): 155-164, 2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38590997

RESUMO

Background: CONVERGE was a prospective, multicenter, randomized controlled trial that evaluated the safety of Hybrid Atrial Fibrillation Convergent (HC) and compared its effectiveness to endocardial catheter ablation (CA) for the treatment of persistent atrial fibrillation (PersAF) and longstanding PersAF (LSPAF). In 2020, we reported that CONVERGE met its primary safety and effectiveness endpoints. The primary objective of the present study is to report CONVERGE trial results for quality of life (QOL) and Class I/III anti-arrhythmic drug (AAD) utilization following HC. Methods: Eligible patients had drug-refractory symptomatic PersAF or LSPAF and a left atrium diameter ≤6.0 cm. Enrolled patients were randomized 2:1 to receive HC or CA. Atrial Fibrillation Severity Scale (AFSS) and the 36-Item Short Form Health Survey (SF-36) were assessed at baseline and 12 months; statistical comparison was performed using paired t-tests. AAD utilization at baseline through 12 and 18 months post-procedure was evaluated; statistical comparison was performed using McNemar's tests. Results: A total of 153 patients were treated with either HC (n=102) or CA (n=51). Of the 102 HC patients, 38 had LSPAF. AFSS and SF-36 Mental and Physical Component scores were significantly improved at 12 months versus baseline with HC overall and for the subset of LSPAF patients treated with either HC or CA. The proportion of HC patients (n=102) who used Class I /III AADs at 12 and 18 months was significantly less (33.3% and 36.3%, respectively) than baseline (84.3%; P<0.001). In LSPAF patients who underwent HC (n=38), AADs use was 29.0% through 18 months follow-up versus 71.1% at baseline (P<0.001). Conclusions: HC reduced AF symptoms, significantly improved QOL, and reduced AAD use in patients with PersAF and LSPAF. ClinicalTrialsgov Identifier: NCT01984346.

3.
JACC Clin Electrophysiol ; 9(8 Pt 2): 1543-1554, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37294263

RESUMO

BACKGROUND: High-frequency, low-tidal-volume (HFLTV) ventilation is a safe and simple strategy to improve catheter stability and first-pass isolation during pulmonary vein (PV) isolation. However, the impact of this technique on long-term clinical outcomes has not been determined. OBJECTIVES: This study sought to assess acute and long-term outcomes of HFLTV ventilation compared with standard ventilation (SV) during radiofrequency (RF) ablation of paroxysmal atrial fibrillation (PAF). METHODS: In this prospective multicenter registry (REAL-AF), patients undergoing PAF ablation using either HFLTV or SV were included. The primary outcome was freedom from all-atrial arrhythmia at 12 months. Secondary outcomes included procedural characteristics, AF-related symptoms, and hospitalizations at 12 months. RESULTS: A total of 661 patients were included. Compared with those in the SV group, patients in the HFLTV group had shorter procedural (66 [IQR: 51-88] minutes vs 80 [IQR: 61-110] minutes; P < 0.001), total RF (13.5 [IQR: 10-19] minutes vs 19.9 [IQR: 14.7-26.9] minutes; P < 0.001), and PV RF (11.1 [IQR: 8.8-14] minutes vs 15.3 [IQR: 12.4-20.4] minutes; P < 0.001) times. First-pass PV isolation was higher in the HFLTV group (66.6% vs 63.8%; P = 0.036). At 12 months, 185 of 216 (85.6%) in the HFLTV group were free from all-atrial arrhythmia, compared with 353 of 445 (79.3%) patients in the SV group (P = 0.041). HLTV was associated with a 6.3% absolute reduction in all-atrial arrhythmia recurrence, lower rate of AF-related symptoms (12.5% vs 18.9%; P = 0.046), and hospitalizations (1.4% vs 4.7%; P = 0.043). There was no significant difference in the rate of complications. CONCLUSIONS: HFLTV ventilation during catheter ablation of PAF improved freedom from all-atrial arrhythmia recurrence, AF-related symptoms, and AF-related hospitalizations with shorter procedural times.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Estudos Prospectivos , Resultado do Tratamento , Volume de Ventilação Pulmonar , Recidiva Local de Neoplasia/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos
4.
Heart Rhythm O2 ; 4(2): 111-118, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36873309

RESUMO

Background: Favorable clinical outcomes are difficult to achieve in long-standing persistent atrial fibrillation (LSPAF) with catheter ablation (CA). The CONVERGE (Convergence of Epicardial and Endocardial Ablation for the Treatment of Symptomatic Persistent Atrial FIbrillation) trial evaluated the effectiveness of hybrid convergent (HC) ablation vs endocardial CA. Objective: The study sought to evaluate the safety and effectiveness of HC vs CA in the LSPAF subgroup from the CONVERGE trial. Methods: The CONVERGE trial was a prospective, multicenter, randomized trial that enrolled 153 patients at 27 sites. A post hoc analysis was performed on LSPAF patients. The primary effectiveness was freedom from atrial arrhythmias off new or increased dose of previously failed or intolerant antiarrhythmic drugs (AADs) through 12 months. The primary safety endpoint was major adverse event incidence through 30 days with HC. Key secondary effectiveness measures included (1) percent of patients achieving ≥90% AF burden reduction vs baseline and (2) AF freedom. Results: Sixty-five patients (42.5% of total enrollment) had LSPAF; 38 in HC and 27 in CA. Primary effectiveness was 65.8% (95% confidence interval [CI] 50.7%-80.9%) with HC vs 37.0% (95% CI 5.1%-52.4%) with CA (P = .022). Through 18 months, these rates were 60.5% (95% CI 50.0%-76.1%) with HC vs 25.9% (95% CI 9.4%-42.5%) with CA (P = .006). Secondary effectiveness rates were higher than CA with HC at 12 and 18 months. Freedom from atrial arrhythmias off AADs was 52.6% (95% CI 36.8%-68.5%) and 47.4% (95% CI 31.5%-63.2%) with HC at 12 and 18 months vs 25.9% (95% CI 9.4%-42.5%) and 22.2% (95% CI 6.5%-37.9%) with CA, respectively (12 months: P = .031; 18 months: P = .038). Three (7.9%) major adverse events occurred within 30 days of HC. Conclusion: Post hoc analysis demonstrated effectiveness and acceptable safety of HC compared with CA in LSPAF.

5.
Heart Rhythm ; 19(1): 22-29, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34332966

RESUMO

BACKGROUND: Left ventricular (LV) endocardial pacing is a promising method to deliver cardiac resynchronization therapy (CRT). WiSE-CRT is a wireless LV endocardial pacing system, and delivers ultrasonic energy to an LV electrode. OBJECTIVE: The purpose of this study was to present short-term outcomes with the WiSE-CRT system in centers with no prior implanting experience. METHODS: Data were prospectively collected from 19 centers where WiSE-CRT systems were implanted during the roll-in phase of the SOLVE-CRT trial. Patients were followed at 1, 3, and 6 months, including transthoracic echo (TTE) at 6 months. RESULTS: The WiSE-CRT was successfully implanted in all 31 attempted cases, and 30 patients completed the 6-month follow-up. One patient underwent heart transplantation 1 month after implantation, and was excluded. Fourteen (46.7%) patients demonstrated ≥1 NYHA class improvement. TTE data were available in 29 patients. LV ejection fraction, LV end-systolic volume, and LV end-diastolic volume improved from 28.3% ± 6.7% to 33.5% ± 6.9% (P < .001), 134.9 ± 51.3 mL to 111.1 ± 40.3 mL (P = .0004), and 185.4 ± 58.8 mL to 164.9 ± 50.6 mL (P = .0017), respectively. There were 3 (9.7%) device-related type 1 complications: 1 insufficient LV pacing, 1 embolization of an unanchored LV electrode, and 1 skin infection. CONCLUSIONS: We demonstrated a high success rate of LV endocardial electrode placement in centers with no prior implanting experience. Favorable clinical responses in heart failure symptoms and significant LV reverse remodeling were noted.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca , Terapia de Ressincronização Cardíaca/métodos , Insuficiência Cardíaca/terapia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Desenho de Prótese
6.
Circ Arrhythm Electrophysiol ; 13(12): e009288, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33185144

RESUMO

BACKGROUND: The limited effectiveness of endocardial catheter ablation (CA) for persistent and long-standing persistent atrial fibrillation (AF) treatment led to the development of a minimally invasive epicardial/endocardial ablation approach (Hybrid Convergent) to achieve a more comprehensive lesion set with durable transmural lesions. The multicenter randomized controlled CONVERGE trial (Convergence of Epicardial and Endocardial Ablation for the Treatment of Symptomatic Persistent AF) evaluated the safety of Hybrid Convergent and compared its effectiveness to CA for persistent and long-standing persistent AF treatment. METHODS: One-hundred fifty-three patients were randomized 2:1 to Hybrid Convergent versus CA. Primary effectiveness was freedom from AF/atrial flutter/atrial tachycardia absent new/increased dosage of previously failed/intolerant class I/III antiarrhythmic drugs through 12 months. Primary safety was major adverse events through 30 days. CONVERGE permitted left atrium size up to 6 cm and imposed no limits on AF duration, making it the only ablation trial to substantially include long-standing persistent-AF, that is, 42% patients with long-standing persistent-AF. RESULTS: Of 149 evaluable patients at 12 months, primary effectiveness was achieved in 67.7% (67/99) patients with Hybrid Convergent and 50.0% (25/50) with CA (P=0.036) on/off previously failed antiarrhythmic drugs and in 53.5% (53/99) versus 32.0% (16/50; P=0.0128) respectively off antiarrhythmic drugs. At 18 months using 7-day Holter, 74.0% (53/72) Hybrid Convergent and 55% (23/42) CA patients experienced ≥90% AF burden reduction. A total of 2.9% (3/102) patients had primary safety events within 7 days, and 4.9% (5/102) between 8 and 30 days postprocedure. No deaths, cardiac perforations, or atrioesophageal fistulas occurred. All but one primary safety event resolved. CONCLUSIONS: The Hybrid Convergent procedure has superior effectiveness compared to the CA for the treatment of persistent and long-standing persistent atrial fibrillation. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT01984346.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , Idoso , Antiarrítmicos/uso terapêutico , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Veias Pulmonares/fisiopatologia , Recidiva , Fatores de Tempo , Resultado do Tratamento , Reino Unido , Estados Unidos
7.
Pacing Clin Electrophysiol ; 40(4): 391-400, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28151545

RESUMO

BACKGROUND: Atrial fibrillation (AF) prevalence increases significantly with age. Little is known about the effect of AF ablation on quality of life and healthcare utilization in the elderly. The objective of this study was to quantify the healthcare utilization and quality of life benefits of catheter ablation for AF, for patients ≥65 years compared to patients <65 years. METHODS: Two multicenter U.S. registry studies enrolled patients with paroxysmal AF. Baseline characteristics and acute outcomes were collected for 736 patients receiving catheter ablation with the Navistar® ThermoCool® SF Catheter (Biosense Webster, Inc., Diamond Bar, CA, USA). Healthcare utilization and quality of life outcomes were collected through 1 year postablation for 508 patients. RESULTS: The rates of acute pulmonary vein isolation were high and similar between patients ≥65 years and <65 years (97.5% vs 95.8%, P = 0.2130). Length of stay for the index procedure was similar between age groups with 82.2% of the older group and 83.2% of the younger group having one-day hospitalization. Disease-specific quality of life instrument scores improved significantly and similarly for older and younger patients at 1 year postablation, compared to baseline. AF-related hospitalizations and emergency department visits were similar or lower in older patients compared to younger patients, as reported at 1 year postablation. CONCLUSION: For older patients undergoing catheter ablation for paroxysmal AF, healthcare utilization parameters were lower or not significantly different than for younger patients, and quality of life outcomes were similarly improved. These findings support the use of catheter ablation as a treatment option in older patients with paroxysmal AF.


Assuntos
Fibrilação Atrial/psicologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/psicologia , Ablação por Cateter/estatística & dados numéricos , Acessibilidade aos Serviços de Saúde/estatística & dados numéricos , Qualidade de Vida/psicologia , Adulto , Distribuição por Idade , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/epidemiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prevalência , Estudos Retrospectivos , Distribuição por Sexo , Resultado do Tratamento , Estados Unidos/epidemiologia , Revisão da Utilização de Recursos de Saúde , Adulto Jovem
8.
J Cardiovasc Electrophysiol ; 25(8): 852-858, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24602038

RESUMO

INTRODUCTION: This report presents safety data on the use of a new open-irrigation radiofrequency ablation (RFA) catheter with a 56-hole porous tip in 742 patients enrolled in 2 US prospective, multicenter observational registry studies representing real-world use of the catheter. METHODS: This analysis is comprised of patients who underwent RFA of drug-refractory recurrent symptomatic paroxysmal atrial fibrillation (AF). Acute adverse events (AEs) were collected and categorized by seriousness, timing, and relatedness, with 7 days of follow-up data in one study and at least 120 days of data from a 1-year follow-up in the other. Acute serious adverse events (SAEs) that were identified as potentially related to the device and/or procedure were adjudicated by an independent safety committee. RESULTS: A total of 30 patients (4.0%) in the combined studies experienced an acute SAE related to the device and/or procedure, which was similar in the subset of patients age 65 and over (4.2%). These SAEs included 1.2% cardiac tamponade/perforation, 0.7% pericarditis, 0.5% pulmonary events, and 0.8% vascular access complications. No myocardial infarction, stroke, transient ischemic attack, or atrioesophageal fistulas within 7 days postprocedure were reported. In the study with extended follow-up, 1 pulmonary vein stenosis and 1 esophageal injury were seen beyond 7 days postprocedure (0.2% each). There were no device or procedure related deaths. CONCLUSION: Results from 2 large observational studies demonstrated that a new porous tip RFA catheter was safe for the treatment of drug refractory, recurrent, symptomatic paroxysmal AF, including treatment of older patients (≥65 years).


Assuntos
Fibrilação Atrial/cirurgia , Cateteres Cardíacos , Ablação por Cateter/instrumentação , Irrigação Terapêutica/instrumentação , Idoso , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Recidiva , Sistema de Registros , Fatores de Risco , Irrigação Terapêutica/efeitos adversos , Fatores de Tempo , Resultado do Tratamento , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA