Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Orthop Traumatol Surg Res ; 103(1): 137-140, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-27871969

RESUMO

Oxidized zirconium (Oxinium™; Smith & Nephew, Memphis, TN, USA) articulated with polyethylene in total hip arthroplasty (THA) appeared to have the potential to reduce wear dramatically. The thermally oxidized metal zirconium surface is transformed into ceramic-like hard surface that is resistant to abrasion. The exposure of soft zirconium metal under hard coverage surface after the damage of oxidized zirconium femoral head has been described. It occurred following joint dislocation or in situ succeeding disengagement of polyethylene liner. We reported three cases of misuse of Oxinium™ (Smith & Nephew, Memphis, TN, USA) heads. These three cases resulted in catastrophic in situ wear and inevitable failure although there was no advice, indication or recommendation for this use from the manufacturer.


Assuntos
Artroplastia de Quadril/efeitos adversos , Prótese de Quadril/efeitos adversos , Falha de Prótese , Zircônio , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Oxirredução , Polietileno , Desenho de Prótese
2.
J Bone Joint Surg Br ; 88(6): 783-9, 2006 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-16720774

RESUMO

In this retrospective study we evaluated the method of acute shortening and distraction osteogenesis for the treatment of tibial nonunion with bone loss in 17 patients with a mean age of 36 years (10 to 58). The mean bone loss was 5.6 cm (3 to 10). In infected cases, we performed the treatment in two stages. The mean follow-up time was 43.5 months (24 to 96). The mean time in external fixation was 8.0 months (4 to 13) and the mean external fixator index was 1.4 months/cm (1.1 to 1.8). There was no recurrence of infection. The bone evaluation results were excellent in 16 patients and good in one, while functional results were excellent in 15 and good in two. The complication rate was 1.2 per patient. We conclude that acute shortening and distraction osteogenesis is a safe, reliable and successful method for the treatment of tibial nonunion with bone loss, with a shorter period of treatment and lower rate of complication.


Assuntos
Fraturas não Consolidadas/cirurgia , Osteogênese por Distração/métodos , Fraturas da Tíbia/cirurgia , Adolescente , Adulto , Doenças Ósseas Infecciosas/diagnóstico por imagem , Doenças Ósseas Infecciosas/fisiopatologia , Doenças Ósseas Infecciosas/cirurgia , Criança , Feminino , Fixação de Fratura/métodos , Fraturas não Consolidadas/diagnóstico por imagem , Fraturas não Consolidadas/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Osteoporose/diagnóstico por imagem , Osteoporose/fisiopatologia , Osteoporose/cirurgia , Complicações Pós-Operatórias , Radiografia , Reoperação , Estudos Retrospectivos , Fraturas da Tíbia/diagnóstico por imagem , Fraturas da Tíbia/fisiopatologia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA