Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
J Immunoassay Immunochem ; 38(2): 190-201, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-27636538

RESUMO

Human epidermal growth factor is a small peptide consisting of 53 amino acid residues, which stimulates cell proliferation and is associated with several human carcinomas. A simple sandwich-type ultramicroELISA assay (UMELISA), based on the advantages of high affinity reaction between streptavidin and biotin has been developed for the measurement of EGF in human serum samples. Strips coated with a high affinity monoclonal antibody directed against EGF are used as solid phase, to ensure the specificity of the assay. The EGF assay was completed in 18 hr, with a measuring range of 39-2500 pg/mL. The intra- and inter-assay coefficients of variation were 4.4-7.3% and 0-5.1%, respectively, depending on the EGF concentrations evaluated. Percentage recovery ranged from 96-104%. Regression analysis showed a good correlation with the commercially available Human EGF Immunoassay Quantikine® ELISA kit (n = 130, r = 0.92, P < 0.01). The analytical performance characteristics of our UMELISA EGF endorse its use for the quantification of EGF in human serum samples.


Assuntos
Ensaio de Imunoadsorção Enzimática/métodos , Fator de Crescimento Epidérmico/sangue , Microquímica/métodos , Anticorpos Monoclonais/imunologia , Fator de Crescimento Epidérmico/imunologia , Humanos , Análise de Regressão
2.
Clin Chim Acta ; 421: 73-8, 2013 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-23481450

RESUMO

BACKGROUND: Since 2005, a newborn screening program for congenital adrenal hyperplasia (CAH) by measuring 17-alpha-hydroxyprogesterone (17OHP) in dried blood spots was introduced in Cuba. METHODS: The hormone was measured by the 17OHP Neonatal UMELISA method, in samples collected on the 5th day as average. Confirmatory test was performed to those neonates with 17OHP values above 55 nmol/l. Some perinatal factors that can influence on 17OHP levels were studied. RESULTS: From January 2005 to December 2010, 621,303 newborns were screened and 39 CAH cases were detected. Coverage of the program reached 98%. The incidence of CAH in Cuba was 1:15,931, similar to that reported by other programs. A recall for suspected CAH was performed in 10,799 cases (1.74%). Therapy in classical CAH patients was started at the mean age of 22 days. 17OHP levels were significantly higher in newborns with lower birth-weight (BW) and/or gestational age (GA). In addition, 17OHP values were affected by the gender, twin status or mode of delivery. CONCLUSIONS: In Cuba, the nationwide newborn screening program has allowed the early detection of CAH. The use of an optimized cut-off level for BW or GA could lead to a reduction in the percentage of recalled babies.


Assuntos
17-alfa-Hidroxiprogesterona/sangue , Hiperplasia Suprarrenal Congênita/sangue , Hiperplasia Suprarrenal Congênita/diagnóstico , Triagem Neonatal , Hiperplasia Suprarrenal Congênita/epidemiologia , Peso ao Nascer , Cuba/epidemiologia , Teste em Amostras de Sangue Seco , Diagnóstico Precoce , Feminino , Idade Gestacional , Humanos , Incidência , Lactente , Recém-Nascido , Masculino
3.
Clin Chim Acta ; 394(1-2): 63-6, 2008 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-18442476

RESUMO

BACKGROUND: 17alpha-hydroxyprogesterone has been used for the diagnosis of congenital adrenal hyperplasia (CAH) in the newborn period. METHODS: A simple and rapid competitive ultramicro ELISA assay based on competition between 17-OHP-alkaline phosphatase conjugate and 17-OHP in blood specimens for a limited number of binding sites on specific polyclonal rabbit anti-17-OHP antibodies, has been developed for the measurement of 17-OHP in dried blood spots on filter paper. The assay buffer contains danazol to displace 17-OHP from steroid-binding proteins. RESULTS: The 17-OHP assay was completed in 3 h, with a measuring range of 10-250 nmol/l. The intra- and inter-assay CV were 5.5-8.2% and 6.4-9.1%, respectively, depending on the 17-OHP concentrations. The recovery ranged from 98-103%. Of 3750 newborn samples collected on filter paper, 903 from the national neonatal screening program were analyzed, and the mean 17-OHP concentration was 12.2 nmol/l. Our assay showed high Pearson and concordance correlations with the commercially available ICN Neoscreen ELISA 17alpha-hydroxyprogesterone kit. CONCLUSIONS: The analytical performance characteristics of our 17-OHP Neonatal UMELISA suggest that it can be used for the neonatal screening of CAH.


Assuntos
17-alfa-Hidroxiprogesterona/sangue , 17-alfa-Hidroxiprogesterona/imunologia , Técnicas Imunoenzimáticas/instrumentação , Técnicas Imunoenzimáticas/métodos , Microquímica/instrumentação , Microquímica/métodos , Especificidade de Anticorpos/imunologia , Reações Cruzadas/imunologia , Humanos , Filtros Microporos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA