Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
EBioMedicine ; 76: 103808, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35065421

RESUMO

BACKGROUND: Type I IFN (IFN-I) is a family of cytokines involved in the pathogenesis of autoimmune and autoinflammatory diseases such as psoriasis. SIDT1 is an ER-resident protein expressed in the lymphoid lineage, and involved in anti-viral IFN-I responses in vivo, through an unclear mechanism. Herein we have dissected the role of SIDT1 in the natural IFN-producing cells, the plasmacytoid dendritic cells (pDC). METHODS: The function of SIDT1 in pDC was determined by silencing its expression in human primary pDC and GEN2.2 cell line. SIDT1 role in vivo was assessed using the imiquimod-induced psoriasis model in the SIDT1-deficient mice (sidt1-/-). FINDINGS: Silencing of SIDT1 in GEN2.2 led to a blockade of the IFN-I response after stimulation of TLR7 and TLR9, without affecting the pro-inflammatory responses or upregulation of maturation markers. We found that SIDT1 migrates from the ER to the endosomal and lysosomal compartments together with TLR9 after CpG stimulation, participating in the access of the TLR9-CpG complex to lysosome-related vesicles, and therefore mediating the activation of TBK1 and the nuclear migration of IRF7, but not of NF-κB. sidt1-/- mice showed a significant decrease in severity parameters of the imiquimod-induced acute psoriasis-like model, associated with a decrease in the production of IFN-I and IFN-dependent chemokines. INTERPRETATION: Our findings indicate that SIDT1 is at the cross-road between the IFN-I and the proinflammatory pathways and constitutes a promising drug target for psoriasis and other diseases mediated by IFN-I responses. FUNDING: This work was supported by the Consejería de Salud y Familias de la Junta de Andalucía (PIER_S1149 and C2_S0050) and Instituto de Salud Carlos III (PI18/00082 and PI21/01151), partly supported by European FEDER funds, and prior funding to MEAR from the Alliance for Lupus Research and the Swedish Research Council.


Assuntos
Ácidos Nucleicos , Psoríase , Animais , Células Dendríticas , Humanos , Imiquimode/efeitos adversos , Camundongos , Ácidos Nucleicos/efeitos adversos , Ácidos Nucleicos/metabolismo , Psoríase/induzido quimicamente , Receptor 7 Toll-Like , Receptor Toll-Like 9/metabolismo
2.
Int J Mol Sci ; 22(13)2021 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-34281193

RESUMO

The kidney is one of the main organs affected by the autoimmune disease systemic lupus erythematosus. Lupus nephritis (LN) concerns 30-60% of adult SLE patients and it is significantly associated with an increase in the morbidity and mortality. The definitive diagnosis of LN can only be achieved by histological analysis of renal biopsies, but the invasiveness of this technique is an obstacle for early diagnosis of renal involvement and a proper follow-up of LN patients under treatment. The use of urine for the discovery of non-invasive biomarkers for renal disease in SLE patients is an attractive alternative to repeated renal biopsies, as several studies have described surrogate urinary cells or analytes reflecting the inflammatory state of the kidney, and/or the severity of the disease. Herein, we review the main findings in the field of urine immune-related biomarkers for LN patients, and discuss their prognostic and diagnostic value. This manuscript is focused on the complement system, antibodies and autoantibodies, chemokines, cytokines, and leukocytes, as they are the main effectors of LN pathogenesis.


Assuntos
Biomarcadores/urina , Nefrite Lúpica/imunologia , Nefrite Lúpica/urina , Autoanticorpos/imunologia , Autoanticorpos/urina , Proteínas do Sistema Complemento/imunologia , Proteínas do Sistema Complemento/urina , Diagnóstico Precoce , Humanos , Cadeias Leves de Imunoglobulina/imunologia , Cadeias Leves de Imunoglobulina/urina , Inflamação/imunologia , Inflamação/urina , Lúpus Eritematoso Sistêmico/imunologia , Lúpus Eritematoso Sistêmico/urina , Nefrite Lúpica/diagnóstico , Prognóstico
3.
J Am Soc Mass Spectrom ; 30(12): 2580-2583, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31724102

RESUMO

Hydrogen/deuterium exchange mass spectrometry (HDX-MS) is a biophysical technique well suited to the characterization of protein dynamics and protein-ligand interactions. In order to accurately define the rate of exchange, HDX experiments require the repeated measure of deuterium incorporation into the target protein across a range of time points. Accordingly, the HDX-MS experiment is well suited to automation, and a number of automated systems for HDX-MS have been developed. The most widely utilized platforms all operate an integrated design, where robotic liquid handling is interfaced directly with a mass spectrometer. With integrated designs, the exchange samples are prepared and injected into the LC-MS following a "real-time" serial workflow. Here we describe a new HDX-MS platform that is comprised of two complementary pieces of automation that disconnect the sample preparation from the LC-MS analysis. For preparation, a plate-based automation system is used to prepare samples in parallel, followed by immediate freezing and storage. A second piece of automation has been constructed to perform the thawing and LC-MS analysis of frozen samples in a serial mode and has been optimized to maximize the duty cycle of the mass spectrometer. The decoupled configuration described here reduces experiment time, significantly improves capacity, and improves the flexibility of the platform when compared with a fully integrated system.


Assuntos
Espectrometria de Massa com Troca Hidrogênio-Deutério/métodos , Descoberta de Drogas/economia , Descoberta de Drogas/instrumentação , Descoberta de Drogas/métodos , Desenho de Equipamento , Análise de Injeção de Fluxo/economia , Análise de Injeção de Fluxo/instrumentação , Análise de Injeção de Fluxo/métodos , Humanos , Espectrometria de Massa com Troca Hidrogênio-Deutério/economia , Espectrometria de Massa com Troca Hidrogênio-Deutério/instrumentação , Ligantes , Proteínas/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA