1.
Eur J Ophthalmol ; 30(2): 307-314, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30782006

RESUMO

PURPOSE: To determine the prevalence and risk factors related to the opacification of the LS-502-1 intraocular lens. METHODS: Cross-sectional study including patients submitted to cataract surgery between January 2010 and March 2012, with implantation of the LS-502-1 intraocular lens. Past medical history was registered and a complete ophthalmologic evaluation, that included best-corrected visual acuity, slit-lamp examination and fundoscopy, was performed. Anterior segment photographs were taken whenever intraocular lens opacification was present. RESULTS: One hundred and sixty-nine eyes of 154 patients were included, mean age 78.5 ± 7.9 years. The average follow-up after intraocular lens implantation was 65.6 ± 10.0 months. Intraocular lens opacification was seen in 53.3% (n = 90) and presented as one of four different patterns: peripheral (15.6%, n = 14), central (4.4%, n = 4), diffuse (71.1%, n = 64) and superficial white deposits (8.9%, n = 8). There was no statistically significant association with systemic or ophthalmic conditions. In patients with bilateral implantation, intraocular lens opacification in one eye was significantly related to intraocular lens opacification in the fellow eye. A significant variability in opacification was found across intraocular lens serial numbers: the odds ratio for opacification in intraocular lens with serial number beginning with 200003 was 6.0 when comparing with the remaining lenses. CONCLUSION: The opacification prevalence of the LS-502-1 intraocular lens was 53.3%, which is the highest ever described for any intraocular lens model. Our results suggest that this occurrence is secondary to an interaction between unknown patient variables and problems related to intraocular lens manufacturing and storage procedures.


Assuntos
Catarata/etiologia , Implante de Lente Intraocular/efeitos adversos , Lentes Intraoculares/efeitos adversos , Complicações Pós-Operatórias/etiologia , Falha de Prótese , Idoso , Idoso de 80 Anos ou mais , Estudos Transversais , Feminino , Humanos , Interações Hidrofóbicas e Hidrofílicas , Masculino , Pessoa de Meia-Idade , Acuidade Visual
2.
Eur J Ophthalmol ; 28(4): NP1-NP6, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29667428

RESUMO

PURPOSE: To report a case of Purtscher retinopathy imaged with optical coherence tomography angiography. METHODS: Case-report. Left eye fundoscopic examination in a 21-year old male after a road traffic accident with chest compression revealed multiple peri-papillary cotton-wool spots and intra- and pre-retinal hemorrhages. A diagnosis of Purtscher retinopathy was assumed. RESULTS: In both the superficial and deep retinal plexuses, acute stage optical coherence tomography angiography identified multiple irregular areas of capillary non-perfusion that extended beyond the clinically visible peri-papillary cotton-wool spots. At 5-month follow-up, despite the clearing of visible cotton-wool spots, there were still permanent areas of irregular capillary non-perfusion and inner retina atrophy. These sequelae, along with a decrease in the peri-papillary retinal nerve fiber layer thickness, were consistent with a suboptimal visual outcome and a dense inferior arcuate scotoma. CONCLUSION: Baseline and follow-up optical coherence tomography angiography was able to detect, quantify, and map focal microvascular abnormalities at the level of the superficial and deep inner retinal vascular plexuses. These lesions were consistent with late stage structural and functional sequelae, conferring them prognostic value.


Assuntos
Angiofluoresceinografia/métodos , Retina/patologia , Doenças Retinianas/diagnóstico , Vasos Retinianos/patologia , Tomografia de Coerência Óptica/métodos , Capilares/patologia , Seguimentos , Fundo de Olho , Humanos , Masculino , Adulto Jovem
3.
Ophthalmic Res ; 57(4): 239-246, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28199995

RESUMO

PURPOSE: To compare endothelial cell (EC) variation after anterior chamber phakic intraocular lens (AC-pIOL) implantation in highly myopic patients with a preoperative anterior chamber depth (ACD) between 2.8 and 3.0 versus ≥3.0 mm. METHODS: A total of 280 eyes submitted to primary AC-pIOL implantation were analyzed. Pre- and postoperative values for uncorrected distance visual acuity, corrected distance visual acuity, spherical equivalent, ACD (endothelial surface), and EC count were collected. The eyes were divided into 2 groups: group A - ACD between 2.8 and 3.0 mm; group B - ACD ≥3.0 mm. Mean global EC loss (ECL) and loss for each ACD group, according to pIOL type, were analyzed. RESULTS: Significant improvement of the spherical equivalent (-11.38 ± 4.57 vs. -0.49 ± 0.79; p = 0.000) and a significant decrease in EC density (2,810.95 ± 343.88 vs. 2,584.09 ± 374.88 cells/mm2; p = 0.000) were noted. The mean annual ECL was -2.19 ± 3.97%. Regarding group A (n = 80), a mean annual ECL of -2.06 ± 3.88% was registered, higher for the Acrysof Cachet® subtype, while group B (n = 200) showed -2.25 ± 4.01% ECL, higher for the Verisyse® subtype. There was no significant difference between the groups (p = 0.96). CONCLUSIONS: AC-pIOL implantation significantly improves the spherical equivalent in myopic patients. The mean annual ECL after pIOL implantation was higher in the larger ACD group, but this value was not statistically significant. A 2.8-mm ACD value seems to be a safe cutoff for AC-pIOL implantation.


Assuntos
Câmara Anterior/diagnóstico por imagem , Implante de Lente Intraocular/métodos , Miopia Degenerativa/cirurgia , Lentes Intraoculares Fácicas , Refração Ocular/fisiologia , Adulto , Contagem de Células , Endotélio Corneano/patologia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Miopia Degenerativa/diagnóstico , Miopia Degenerativa/fisiopatologia , Desenho de Prótese , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
4.
J Cataract Refract Surg ; 42(9): 1324-1331, 2016 09.
Artigo em Inglês | MEDLINE | ID: mdl-27697251

RESUMO

PURPOSE: To report late postoperative opacification of a model of hydrophilic-hydrophobic acrylic intraocular lens (IOL) as well as the clinical consequences and laboratory characteristics. SETTING: Department of Ophthalmology, Centro Hospitalar e Universitário de Coimbra, Coimbra, Portugal. DESIGN: Retrospective case series. METHODS: Medical records were reviewed of patients with Lentis LS-502-1 IOL opacification reporting visual loss who had IOL explantation between November 2013 and March 2015. Patients were identified in the emergency room or during regular follow-up visits. Explanted IOLs were analyzed at the Ophthalmic Explants Biobank, Vissum, Spain, or at the John A. Moran Eye Center, University of Utah, USA. RESULTS: Twenty opacified IOLs were explanted from 19 patients. The mean interval between cataract surgery and diagnosis of opacification was 29.15 months ± 9.57 (SD) (range 6 to 45 months). Opacification led to a statistically significant reduction in corrected distance visual acuity (mean 0.86 ± 0.76 logMAR; P < .001) and occurred in 5.1% of the hydrophilic-hydrophobic acrylic IOLs implanted at the department. The most frequently associated medical conditions were arterial hypertension, diabetes, and glaucoma. All IOLs but 1 had a similar pattern of opacification, with yellowish diffuse opacification uniformly distributed and calcium deposits on the surface and/or subsurface of the optic and haptics and within the IOL material. CONCLUSIONS: Opacification of the hydrophilic-hydrophobic acrylic IOL was found in a significant number of patients and had a significant effect on their vision. The opacification was attributed to primary calcification. FINANCIAL DISCLOSURE: None of the authors has a financial or proprietary interest in any material or method mentioned.


Assuntos
Resinas Acrílicas , Lentes Intraoculares/efeitos adversos , Facoemulsificação , Complicações Pós-Operatórias , Extração de Catarata , Humanos , Implante de Lente Intraocular , Estudos Retrospectivos , Espanha
5.
J Cataract Refract Surg ; 42(4): 520-3, 2016 04.
Artigo em Inglês | MEDLINE | ID: mdl-27113872

RESUMO

UNLABELLED: Iridodialysis is a common occurrence after trauma and can be the source of considerable morbidity for the patients. Several options to repair iridodialysis are described in the literature. We present a new technique-a single-thread single-knot suture. This simple approach does not require special material and uses a single thread and a single knot, avoiding the need for using multiple sutures or placing multiple knots. We used this technique in several patients, and it appears to be an effective alternative to iridodialysis repair. FINANCIAL DISCLOSURE: None of the authors has a financial or proprietary interest in any material or method mentioned.


Assuntos
Iris/cirurgia , Técnicas de Sutura , Humanos , Suturas
6.
J Cataract Refract Surg ; 39(11): 1653-9, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24160381

RESUMO

PURPOSE: To compare visual function after bilateral implantation of multifocal Lentis Mplus LS-312 (Group A) or Acrysof Restor SN6AD1 (Group B) intraocular lenses (IOLs). SETTING: Ophthalmology Unit, Centro Hospitalar e Universitário de Coimbra, and Visual Neuroscience Laboratory, IBILI, Faculty of Medicine, University of Coimbra, Coimbra, Portugal. DESIGN: Comparative case series. METHODS: Patients between 49 years and 76 years had bilateral cataract surgery with multifocal IOL implantation. Patients were evaluated preoperatively and 3 months postoperatively for distance, intermediate, and near visual acuities; static photopic and mesopic contrast sensitivity; and visual acuity under a glare source using the Metrovision contrast sensitivity platform. Color vision was evaluated with the Cambridge Colour Test. RESULTS: Group A comprised 56 eyes and Group B, 44 eyes. Visual and refractive results were comparable between the 2 groups. Photopic contrast sensitivity was significantly better in Group B at intermediate (2.2 cycles per degree [cpd] and 3.4 cpd) and high (7.1 cpd and 23.6 cpd) spatial frequencies. Under low mesopic conditions (0.08 candelas/m(2)), differences were significant at 1.1 cpd and 2.2 cpd spatial frequencies. There were no differences in visual acuity under a glare source or in color vision. CONCLUSIONS: Both IOLs provided good distance, intermediate, and near visual acuities. Visual acuity under a glare source and color vision were similar in the 2 groups. However, photopic and low mesopic contrast sensitivities were better in Group B, particularly for intermediate spatial frequencies, which are important for night driving.


Assuntos
Visão de Cores/fisiologia , Sensibilidades de Contraste/fisiologia , Ofuscação , Implante de Lente Intraocular , Lentes Intraoculares , Pseudofacia/fisiopatologia , Acuidade Visual/fisiologia , Idoso , Topografia da Córnea , Feminino , Humanos , Masculino , Microscopia Acústica , Pessoa de Meia-Idade , Facoemulsificação , Estudos Prospectivos , Desenho de Prótese , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA