Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 41
Filtrar
1.
Int J Surg ; 2024 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-38913429

RESUMO

BACKGROUND: To evaluate the safety and efficacy of intra-wound vancomycin powder in reducing surgical site infections (SSIs) after spine surgery. DESIGN: A prospective, double-blind, randomized controlled study. PARTICIPANTS: Patients who underwent posterior lumbar interbody fusion (PLIF) surgery from May 2021 to September 2022. METHODS: Patients who underwent posterior lumbar interbody fusion (PLIF) surgery between May 2021 and September 2022 were included. Participants were randomized to the vancomycin treatment or control groups using block randomization (block size 4). Except for baseline and surgical data, the plasma levels of white blood cells, C-reactive protein (CRP), erythrocyte sedimentation rate (ESR), aspartate aminotransferase, alanine aminotransferase, and serum vancomycin concentration in the groups were analyzed on postoperative days (PODs) 1, 3, and 5. Vancomycin concentration was measured daily until the drainage tubes were removed. The primary outcomes were the 90-day vancomycin-related adverse reactions and SSI rates. Secondary outcomes were perioperative hematological parameters and vancomycin serum (drain) concentrations. RESULTS: A total of 156 participants (78 each in each group) were analyzed by an independent researcher. The follow-up rate was 91%. All participants were followed up for at least 90 days. The 90-day SSI rate in the vancomycin group was 1.3% (1/78), comprising one case of superficial infection. The SSI rate in the control group was 10.3% (8/78), comprising seven cases of superficial infection and one case of deep infection. Compared with that in the control group, the SSI rate in the vancomycin group was decreased by 87.5%, with a statistically significant difference (RR=0.125, 95% CI=0.016-0.976). Additionally, the vancomycin group demonstrated a statistically significant decrease in serum ESR on POD 3 (P=0.039) and CRP on POD 5 (P=0.024) compared to the control group. The local plasma concentration of vancomycin remained elevated for at least 4 days postoperatively, while the serum concentration of vancomycin remined low. Vancomycin-associated adverse reactions were not observed. CONCLUSION: Intra-wound application of vancomycin powder is a safe and effective procedure for reducing the risk of SSI during PLIF surgery.

2.
Eur Spine J ; 33(6): 2154-2165, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38727735

RESUMO

OBJECTIVE: The purpose of this study was to investigate the learning curve of percutaneous endoscopic transforaminal discectomy (PETD) and interlaminar unilateral biportal endoscopic discectomy (UBED) in the treatment of lumbar disc herniation (LDH). METHODS: Between 2018 and 2023, 120 consecutive patients with lumbar disc herniation (LDH) treated by endoscopic lumbar discectomy were retrospectively included. The PETD group comprised 87 cases, and the UBED group comprised 33 cases. Cumulative sum analysis was used to evaluate the learning curve, with the occurrence of complications or unresolved symptoms defined as surgical failure, and variables of different phases of the learning curve being compared. RESULTS: The learning curve analysis identified the cutoff point at 40 cases in the PETD group and 15 cases in the UBED group. In the mastery phase, both PETD and UBED demonstrated a significant reduction in operation times (approximately 38 min for PTED and 49 min for UBED). In both PETD and UBED groups, the surgical failure rates during the learning and mastery phases showed no statistically significant differences. The visual analogue scale at the last follow-up was significantly lower than before surgery in both the PETD and UBED groups. CONCLUSION: PETD and UBED surgery are effective in the treatment of LDH with a low incidence of complications. However, achieving mastery in PETD necessitates a learning curve of 40 cases, while UBED requires a minimum of 15 cases to reach proficiency.


Assuntos
Discotomia Percutânea , Endoscopia , Deslocamento do Disco Intervertebral , Curva de Aprendizado , Vértebras Lombares , Humanos , Deslocamento do Disco Intervertebral/cirurgia , Deslocamento do Disco Intervertebral/diagnóstico por imagem , Discotomia Percutânea/métodos , Discotomia Percutânea/educação , Masculino , Feminino , Pessoa de Meia-Idade , Vértebras Lombares/cirurgia , Vértebras Lombares/diagnóstico por imagem , Adulto , Endoscopia/métodos , Endoscopia/educação , Estudos Retrospectivos , Resultado do Tratamento
3.
Eur Spine J ; 33(2): 680-686, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38097782

RESUMO

BACKGROUND: Adolescent idiopathic scoliosis (AIS) is a spinal deformity that affects adolescents and poses a challenging public health problem. Compared to the general population, adolescents with AIS have a higher prevalence of hip dysplasia. However, the mechanisms underlying the impact of hip dysplasia on the coronal balance of the spine remain poorly understood. We hypothesized that the combination of AIS with hip dysplasia would exacerbate coronal imbalance. METHODS: We retrospectively analyzed the medical records and radiographs of adolescents diagnosed with AIS between 2015 and 2020. Participants were divided into two groups: those with hip dysplasia and those without. We recorded parameters related to the coronal deformity of the spine, sacral and pelvic obliquity, and center edge angle (CEA). We investigated differences in these parameters in those with and without hip dysplasia and analyzed their relationships in those with combined AIS and hip dysplasia. RESULTS: A total of 103 adolescents were included, 36 with hip dysplasia and 67 without. Those with hip dysplasia had significantly higher sacroiliac discrepancy (SID) compared to those without (t = - 2.438, P = 0.017). In adolescents with hip dysplasia, only iliac obliquity angle (IOA) was significantly correlated with SID (r = - 0.803, P < 0.001), with a linear relationship between them (r2 = 0.645, P < 0.001). CONCLUSIONS: The incidence of hip dysplasia is higher in the AIS population. In adolescents with combined AIS and hip dysplasia, pelvic obliquity is greater, potentially contributing to the increased prevalence of low back pain.


Assuntos
Luxação do Quadril , Dor Lombar , Escoliose , Adolescente , Humanos , Escoliose/complicações , Escoliose/diagnóstico por imagem , Escoliose/epidemiologia , Luxação do Quadril/complicações , Luxação do Quadril/diagnóstico por imagem , Luxação do Quadril/epidemiologia , Estudos Retrospectivos , Sacro
4.
BMC Musculoskelet Disord ; 24(1): 885, 2023 Nov 14.
Artigo em Inglês | MEDLINE | ID: mdl-37957682

RESUMO

BACKGROUND: The purpose of this study was to report our surgical experience in patients with lumbosacral degenerative diseases who underwent posterior decompression and interbody fusion fixed with cortical bone trajectory screw and sacral alar screw, which is known as low-profile posterior lumbosacral interbody fusion (LP-PLSIF). METHODS: Patients with lumbosacral degenerative disease who underwent LP-PLSIF and traditional PLSIF (control group) internally fixed with pedicle screws were included retrospectively. Patients' demographic data, operative parameters, and perioperative complications were recorded and analyzed. RESULTS: A total of 18 patients were enrolled in this study, which included 9 patients (5 male and 4 female) who underwent LP-PLSIF, and 9 patients (4 male and 5 female) who underwent traditional PLSIF. There wasn't a significant difference in the average age between the two groups, 56.78 ± 10.92 years in the LP-PLSIF group and 60.22 ± 8.21 years in the PLSIF group (p = 0.460). The bone mineral density (BMD) of the two groups of patients were -2.00 ± 0.26 T and -2.13 ± 0.19 T, respectively (P = 0.239). The mean postoperative follow-up time was 12.7 months (range, 12-14 months). The mean operation time was 142.78 ± 11.21 min and 156.11 ± 13.41 min in the LP-PLSIF group and PLSIF group respectively (P < 0.05). The average blood loss was 137.78 ± 37.09 ml in the LP-PLSIF group, and 150.00 ± 27.84 ml in the PLSIF group (P = 0.441). The average postoperative drainage was 85.56 ± 37.45 ml and 122.22 ± 22.24 ml in the LP-PLSIF group and control group respectively (P < 0.05). Patients in the LP-PLSIF group had shorter incision length compared with the control group, 61.44 ± 10.56 mm vs. 74.56 ± 10.22 mm (P < 0.05). The average length of hospitalization of 11.33 ± 2.92 days in the LP-PLSIF group, and 11.11 ± 1.62 days in the PLSIF group (p = 0.844). All patients had significant improvement in VAS pain score, ODI, and JOA evaluation. However, patients in the LP-PLSIF group had better improvement in terms of VAS back pain and ODI in the short term after the operation. There were no neurological complications or wound infection. The fusion rate at the last follow-up was 100% (9 of 9) in the LP-PLSIF group, and 88.89% (8 of 9) in the control group based on CT scans. 1 patient in the control group had asymptomatic sacral pedicle screw loosening. CONCLUSIONS: LP-PLSIF is a safe and effective surgical technique for patients with lumbosacral degenerative disease, which has the potential strength of less invasive and better clinical improvement.


Assuntos
Degeneração do Disco Intervertebral , Parafusos Pediculares , Fusão Vertebral , Humanos , Masculino , Feminino , Pré-Escolar , Degeneração do Disco Intervertebral/diagnóstico por imagem , Degeneração do Disco Intervertebral/cirurgia , Estudos Retrospectivos , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/cirurgia , Região Lombossacral , Fusão Vertebral/efeitos adversos , Fusão Vertebral/métodos , Resultado do Tratamento , Procedimentos Cirúrgicos Minimamente Invasivos
5.
Sci Rep ; 13(1): 16447, 2023 09 30.
Artigo em Inglês | MEDLINE | ID: mdl-37777594

RESUMO

This study aimed to assess the accuracy of cortical bone trajectory (CBT) screws placement guided by a spinous process clamp (SPC) guide. A total of 32 patients who received single-level midline lumbar fusion (MIDLF) surgery between June 2019 and January 2020 were retrospectively analyzed and divided into free-hand (FH) and SPC-guided groups according to the surgical approach. In the FH group, CBT screws was implanted with the assistance of fluoroscopy, while in the SPC group, CBT screws was implanted using the SPC navigator hardwire. A total of 128 screws were assessed in this study, with higher rates of clinically acceptable screw placement (grades A and B) and grade A screws in the SPC group than in the FH guide group (92.2% vs. 79.7%, P = 0.042 and 54.7% vs. 35.9%, P = 0.033, respectively). Misplacement screws (grades C, D, and E) occurred more often in the FH group than in the SPC guide group (20.3% vs. 7.8%, P = 0.042). The incidence of proximal facet joint violation (FJV) was higher in the FH group than in the SPC group (15.6% vs. 3.1%, P = 0.030). The radiation dose and time in the SPC guide group were comparable to those in the FH group (P = 0.063 and P = 0.078). The average operative time was significantly longer in the SPC guide group than in the FH group (267.8 ± 45.5 min vs. 210.9 ± 44.5 min, P = 0.001). Other clinical parameters, such as the average bone mineral density (BMD), intraoperative blood loss, and postoperative hospital stay, were not significantly different. Oswestry disability index (ODI) and back pain visual analogue scale (VAS) scores were significantly improved in both groups compared with preoperatively. SPC guided screw placement was more accurate than the fluoroscopy-assisted FH technique for single-level MIDLF at L4/5. Patients undergoing SPC-guided screw placement can achieve similar clinical outcomes as the fluoroscopy-assisted FH technique.


Assuntos
Parafusos Pediculares , Procedimentos Cirúrgicos Robóticos , Fusão Vertebral , Cirurgia Assistida por Computador , Humanos , Procedimentos Cirúrgicos Robóticos/métodos , Estudos Retrospectivos , Cirurgia Assistida por Computador/métodos , Osso Cortical/diagnóstico por imagem , Osso Cortical/cirurgia , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/cirurgia , Fusão Vertebral/métodos
6.
Spine J ; 23(12): 1908-1919, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37619870

RESUMO

BACKGROUND CONTEXT: Standard partial facetectomies, (Smith-Petersen Osteotomy, (SPO), (Schwab-grade-I) and complete facet resection also known as Ponte osteotomy, (PO), (Schwab-grade-II) are narrowly akin and collectively appreciated as posterior column shortening osteotomies (PCOs). The former is considered a gentler osteotomy grade than the latter. The spine literature provides very little information on their comparison regarding perioperative complications and major curve correction rate outcomes. PURPOSE: To determine whether Schwab-grade-I PCO (SPO) and Schwab-grade-II PCO (PO) are comparably safe in the surgical management of severe rigid scoliosis or kyphoscoliosis patients. STUDY DESIGN/SETTING: Retrospective single-center comparative clinical study. PATIENT SAMPLE: A total of 38 patients with severe rigid scoliosis or kyphoscoliosis were propensity score matched in this study, (SPO-treated); n=21 (55.30%) and (PO-treated); n=17 (44.70%), who underwent primary spinal deformity corrective surgery, respectively. OUTCOME MEASURES: Outcomes included demographics, baseline pulmonary functional outcomes, perioperative complications incidence, hospital costs, Oswestry disability index (ODI), and the Scoliosis Research Society-22 (SRS-22) questionnaire scores. METHODS: Following approval by the Institutional Review Board (IRB) of Beijing Chaoyang Hospital-Affiliated Capital Medical University in Beijing, out of a total of 82 consecutive surgical patients with complete data demonstrating severe and/or rigid spinal deformity, a pool of 38 of the 82 (46.3%) propensity-matched adult (≥18 years) patients with severe rigid scoliosis or kyphoscoliosis defined with a preoperative major curve magnitude of ≥80° on anteroposterior plain radiographs, and flexibility of <25% on bending plain radiographs who underwent primary spinal deformity corrective surgery were retrospectively evaluated. The patients were dichotomized into two osteotomy groups: standard (partial) facetectomy (SPO-treated), n=21 with an average age of 24.67 years, (Schwab-grade-I PCO) and complete facet excision, (PO-treated), (ie, Schwab-grade-II PCO), n=17 with an average age of 23.12 years. The minimum follow-up period was 2 years. Primary outcomes included baseline demographics and clinical features. Secondary outcomes included perioperative [intraoperative, immediate, and 2-year postoperative] complication rates. Tertiary outcomes included perioperative ODI and SRS-22 scores. Statistical analyses were carried out by Student t-test and Pearson's Chi-square test (Fisher's Exact Test), through Python statistical software package. Statistical significance was set at (p<.05). RESULTS: Of the 38 matched severe rigid scoliosis or kyphoscoliosis patients, 55.30% (n=21) were SPO-treated and 44.70% (n=17) were PO-treated patients, respectively. The overall average age of patients was 23.97 years, with a female incidence of 76.32%. Major curve correction rates were 49.19% and 57.40% in SPO-treated and PO-treated patients, respectively, (p>.05). Immediately following surgery, comparable overall complication rates of 28.57% (n=6/21) versus 29.41% (n=5/17) were observed in the SPO-treated and PO-treated patients, respectively, (p=.726). We observed incidences of 9.52%, (n=2/21) versus 5.88%, (n=1/17) for surgical intensive care unit (SICU) admission, and incidences of 4.76%, (n=1/21) versus 5.88%, (n=1/17) for cardiopulmonary events in SPO-treated versus PO-treated patients following corrective surgery, respectively, (p>.05). The incidences of neurological deficits in the SPO-treated and PO-treated patients were respectively, 14.29%, (n=3/21) versus 17.65%, (n=3/17) immediately following surgery, (p>.05), and 0.00%, (n=0/21) in SPO-treated versus 14.28%, (n=3/21) in PO-treated patients at ≥2 years postoperative, (p<.05). Among the three patients that reported neurological deficits in the PO-treated group at ≥2 years postoperative, two patients had pre-existing baseline neurological deficits. The ODI score in the PO-treated group was significantly inferior at a minimum 2-year follow-up, (p<.05). CONCLUSIONS: In the current study, both SPO-treated and PO-treated patients demonstrated statistically comparable surgical complications immediately following corrective surgery. Severe rigid kyphoscoliosis patients with preexisting baseline neurological deficits were more inclined to sustain neurological morbidity following corrective surgery. PCO corrective techniques are warranted as safe options for treating patients with severe rigid spine deformity phenotypes.


Assuntos
Cifose , Escoliose , Adulto , Humanos , Feminino , Adulto Jovem , Escoliose/cirurgia , Escoliose/complicações , Estudos Retrospectivos , Seguimentos , Resultado do Tratamento , Cifose/diagnóstico por imagem , Cifose/cirurgia , Cifose/complicações , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia
7.
Eur Spine J ; 32(10): 3634-3650, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37555956

RESUMO

BACKGROUND: The incidence of mechanical complications is high in patients undergoing posterior spinal fusion (PSF) for adult spinal deformity (ASD), especially for cases with severe sagittal malalignment or a prior spinal fusion requiring three-column osteotomy (3-CO) or spinopelvic fixation (SPF). The purpose of this systematic review and meta-analysis was to compare the complications, revisions, radiographic spinopelvic parameters, health-related quality of life (HRQoL), and surgical data of PSF using multiple-rod constructs to those of two-rod constructs for the treatment of ASD. METHODS: A comprehensive literature search was performed for relevant studies in PubMed, EMBASE, Web of Science, and the Cochrane Library. Complications, revisions, spinopelvic parameters, HRQoL, and surgical date were compared between patients with ASD who underwent PSF using multiple-rod constructs (multi-rod group) and two-rod constructs (two-rod group). RESULTS: Ten studies, comprising 797 patients with ASD (399 in the multi-rod group and 398 in the two-rod group), were included. All these studies were retrospective cohort studies. There were no significant differences in the surgical, wound-related, and systemic complications between the groups. In the multi-rod group, we noted a significantly lower incidence of rod fracture (RR, 0.43; 95% CI 0.33 to 0.57, P < 0.01), pseudoarthrosis (RR, 0.38; 95% CI 0.28 to 0.53, P < 0.01), and revisions (RR, 0.44; 95% CI 0.33 to 0.58, P < 0.01); a superior restoration of PI-LL (WMD, 3.96; 95% CI 1.03 to 6.88, P < 0.01) and SVA (WMD, 31.53; 95% CI 21.16 to 41.90, P < 0.01); a better improvement of ODI score (WMD, 6.82; 95% CI 2.33 to 11.31, P < 0.01), SRS-22 total score (WMD, 0.44; 95% CI 0.06 to 0.83, P = 0.02), and VAS-BP score (WMD, 1.02; 95% CI 0.31 to 1.73, P < 0.01). CONCLUSION: Compared with the two-rod constructs, PSF using multiple-rod constructs was associated with a lower incidence of mechanical complications, a lower revision rate, a superior restoration of sagittal alignment, and a better improvement of HRQoL, without increasing surgical invasiveness. Multiple-rod constructs should be routinely considered to for ASD patients, especially for cases with severe sagittal malalignment or a prior spinal fusion requiring 3-CO or SPF.


Assuntos
Fusão Vertebral , Procedimentos Cirúrgicos Torácicos , Humanos , Adulto , Estudos Retrospectivos , Fusão Vertebral/efeitos adversos , Qualidade de Vida , Coluna Vertebral
8.
J Pers Med ; 13(6)2023 May 26.
Artigo em Inglês | MEDLINE | ID: mdl-37373886

RESUMO

Background: We aimed to propose the apical vertebras distribution modifier to supplement the coronal balance (CB) classification for adult idiopathic scoliosis (AdIS). An algorithm to predict postoperative coronal compensation and avoid postoperative coronal imbalance (CIB) was proposed. Methods: Patients were categorized into CB and CIB groups according to the preoperative coronal balance distance (CBD). The apical vertebras distribution modifier was defined as negative (-) if the centers of the apical vertebras (CoAVs) were on either side of the central sacral vertical line (CSVL) and positive (+) if the CoAVs were on the same side of the CSVL. Results: A total of 80 AdIS patients, with an average age of 25.97 ± 9.20 years, who underwent posterior spinal fusion (PSF) were prospectively recruited. The mean Cobb angle of the main curve was 107.25 ± 21.11 degrees at preoperation. The mean follow-up time was 3.76 ± 1.38 (2-8) years. At postoperation and follow-up, CIB occurred in 7 (70%) and 4 (40%) CB- patients, 23 (50%) and 13 (28.26%) CB+ patients, 6 (60%) and 6 (60%) CIB- patients, and 9 (64.29%) and 10 (71.43%) CIB+ patients. Health-related quality of life (HRQoL) was significantly better in the CIB- group compared with that of the CIB+ group in the dimension of back pain. To avoid postoperative CIB, the correction rate of the main curve (CRMC) should match the compensatory curve for CB-/+ patients; the CRMC should be greater than the compensatory curve for CIB- patients; and the CRMC should be less than the compensatory curve for CIB+ patients, and the inclination of the LIV needs to be reduced. Conclusions: CB+ patients have the least postoperative CIB rate and the best coronal compensatory ability. CIB+ patients are at a high risk of postoperative CIB and have the poorest coronal compensatory capacity in the event of postoperative CIB. The proposed surgical algorithm facilitates the handling of each type of coronal alignment.

9.
Front Bioeng Biotechnol ; 11: 1148342, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36998811

RESUMO

Background: Posterior long spinal fusion was the common procedure for adult spinal deformity (ASD). Although the application of sacropelvic fixation (SPF), the incidence of pseudoarthrosis and implant failure is still high in long spinal fusion extending to lumbosacral junction (LSJ). To address these mechanical complications, advanced SPF technique by multiple pelvic screws or multirod construct has been recommended. This was the first study to compare the biomechanical performance of combining multiple pelvic screws and multirod construct to other advanced SPF constructs for the augmentation of LSJ in long spinal fusion surgery through finite element (FE) analysis. Methods: An intact lumbopelvic FE model based on computed tomography images of a healthy adult male volunteer was constructed and validated. The intact model was modified to develop five instrumented models, all of which had bilateral pedicle screw (PS) fixation from L1 to S1 with posterior lumbar interbody fusion and different SPF constructs, including No-SPF, bilateral single S2-alar-iliac (S2AI) screw and single rod (SS-SR), bilateral multiple S2AI screws and single rod (MS-SR), bilateral single S2AI screw and multiple rods (SS-MR), and bilateral multiple S2AI screws and multiple rods (MS-MR). The range of motion (ROM) and stress on instrumentation, cages, sacrum, and S1 superior endplate (SEP) in flexion (FL), extension (EX), lateral bending (LB), and axial rotation (AR) were compared among models. Results: Compared with intact model and No-SPF, the ROM of global lumbopelvis, LSJ, and sacroiliac joint (SIJ) was decreased in SS-SR, MS-SR, SS-MR, and MS-MR in all directions. Compared with SS-SR, the ROM of global lumbopelvis and LSJ of MS-SR, SS-MR, and MS-MR further decreased, while the ROM of SIJ was only decreased in MS-SR and MS-MR. The stress on instrumentation, cages, S1-SEP, and sacrum decreased in SS-SR, compared with no-SPF. Compared with SS-SR, the stress in EX and AR further decreased in SS-MR and MS-SR. The most significantly decreased ROM and stress were observed in MS-MR. Conclusion: Both multiple pelvic screws and multirod construct could increase the mechanical stability of LSJ and reduce stress on instrumentation, cages, S1-SEP, and sacrum. The MS-MR construct was the most adequate to reduce the risk of lumbosacral pseudarthrosis, implant failure, and sacrum fracture. This study may provide surgeons with important evidence for the application of MS-MR construct in the clinical settings.

10.
Global Spine J ; 13(3): 787-795, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33973487

RESUMO

STUDY DESIGN: Retrospective case-control study. OBJECTIVE: We aimed to evaluate the value of 3-dimensional printing (3DP) spine model in the surgical treatment of severe spinal deformity since the prosperous development of 3DP technology. METHODS: Severe scoliosis or hyper-kyphosis patients underwent posterior fixation and fusion surgery using the 3DP spine models were reviewed (3DP group). Spinal deformity surgeries operated by free-hand screw implantation during the same period were selected as the control group after propensity score matching (PSM). The correction rate, pedicle screw accuracy, and complications were analyzed. Class A and B screws were defined as accurate according to Gertzbein and Robbins criteria. RESULTS: 35 patients were enrolled in the 3DP group and 35 matched cases were included in the control group. The perioperative baseline data and deformity correction rate were similar between both groups (P > .05). However, the operation time and blood loss were significantly less in the 3DP group (296.14 ± 66.18 min vs. 329.43 ± 67.16 min, 711.43 ± 552.28 mL vs. 1322.29 ± 828.23 mL, P < .05). More three-column osteotomies (Grade 3-6) were performed in the 3DP group (30/35, 85.7% vs. 21/35, 60.0%. P = .016). The screw placement accuracy was significantly higher in the 3DP group (422/582, 72.51% vs. 397/575, 69.04%. P = .024). The screw misplacement related complication rate was significantly higher in the free-hand group (6/35 vs. 1/35, P = .046). CONCLUSIONS: The study provided solid evidence that 3DP spine models can enhance surgeons' confidence in performing higher grade osteotomies and improve the safety and efficiency in severe spine deformity correction surgery. 3D printing technology has a good prospect in spinal deformity surgery.

11.
Global Spine J ; 13(4): 995-1004, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-34000874

RESUMO

STUDY DESIGN: Modified Delphi study. OBJECTIVE: The objective of this study was to establish expert consensus on the application of lateral lumbar interbody fusion (LLIF) by using the modified Delphi study. METHODS: From June 2019 to March 2020, Members of the Chinese Study Group for Lateral Lumbar Spine Surgery were selected to collect expert feedback using the modified Delphi method where 65 spine surgeons from all over China agreed to participate. Four rounds were performed: 1 face-to-face meeting and 3 subsequent survey rounds. The consensus was achieved with ≥a 70.0% agreement for each question. The recommendation of grade A was defined as ≥90.0% of the agreement for each question. The recommendation of grade B was defined as 80.0-89.9% of the agreement for each question. The recommendation of grade C was defined as 70.0-79.9% of the agreement for each question. RESULTS: A total of 65 experts formed a panelist group, and the number of questionnaires collected was 63, 59, and 62 in the 3 rounds. In total, 5 sections, 71 questions, and 382 items achieved consensus after the Delphi rounds including summary; preoperative evaluation; application at the lumbar spinal stenosis, lumbar disc herniation, lumbar spondylolisthesis, adult degenerative scoliosis, postoperative adjacent segmental degeneration, and revision surgery; complications; and postoperative follow-up evaluation of LLIF. CONCLUSION: The modified Delphi method was utilized to ascertain an expert consensus from the Chinese Study Group for Lateral Lumbar Spine Surgery to inform clinical decision-making in the application of LLIF. The salient grade A recommendations of the survey are enumerated.

12.
J Neurosurg Spine ; 38(1): 107-114, 2023 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-36029265

RESUMO

OBJECTIVE: Achieving solid fusion of the lumbosacral junction continues to be a challenge in long-segment instrumentation to the sacrum. The purpose of this study was to test the condition of adding sacral anchors through an S1 alar screw (S1AS) and multirod construct relative to using S1 pedicle screws (S1PSs) alone with sacroiliac fixation in lumbosacral junction augmentation. METHODS: Seven fresh-frozen human lumbar-pelvic spine cadaveric specimens were tested under nondestructive moments (7.5 Nm). The ranges of motion (ROMs) in extension, flexion, left and right lateral bending (LB), and axial rotation (AR) of instrumented segments (L3-S1); the lumbosacral region (L5-S1); and the adjacent segment (L2-3) were measured, and the axial construct stiffness (ACS) was recorded. The testing conditions were 1) intact; 2) bilateral pedicle screw (BPS) fixation at L3-S1 (S1PS alone); 3) BPS and unilateral S2 alar iliac screw (U-S2AIS) fixation; 4) BPS and unilateral S1AS (U-S1AS) fixation; 5) BPS and bilateral S2AIS (B-S2AIS) fixation; and 6) BPS and bilateral S1AS (B-S1AS) fixation. Accessory rods were used in testing conditions 3-6. RESULTS: In all directions, the ROMs of L5-S1 and L3-S1 were significantly reduced in B-S1AS and B-S2AIS conditions, compared with intact and S1PS alone. There was no significant difference in reduction of the ROMs of L5-S1 between B-S1ASs and B-S2AISs. Greater decreased ROMs of L3-S1 in extension and AR were detected with B-S2AISs than with B-S1ASs. Both B-S1ASs and B-S2AISs significantly increased the ACS compared with S1PSs alone. The ACS of B-S2AISs was significantly greater than that of B-S1ASs, but with greater increased ROMs of L2-3 in extension. CONCLUSIONS: Adding sacral anchors through S1ASs and a multirod construct was as effective as sacropelvic fixation in lumbosacral junction augmentation. The ACS was less than the sacropelvic fixation but with lower ROMs of the adjacent segment. The biomechanical effects of using S1ASs in the control of long-instrumented segments were moderate (better than S1PSs alone but worse than sacropelvic fixation). This strategy is appropriate for patients requiring advanced lumbosacral fixation, and the risk of sacroiliac joint violation can be avoided.


Assuntos
Parafusos Pediculares , Fusão Vertebral , Humanos , Sacro/cirurgia , Vértebras Lombares/cirurgia , Ílio/cirurgia , Amplitude de Movimento Articular , Rotação , Fenômenos Biomecânicos , Cadáver
13.
Int J Med Robot ; 19(2): e2484, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36413096

RESUMO

BACKGROUND: The purpose of this study was to access the accuracy of cortical bone trajectory screw placement guided by spinous process clamp (SPC). METHODS: Eight formalin-treated cadaveric lumbar specimens with T12-S1 were used. A total of 96 screws were implanted in eight lumbar specimens. RESULTS: In the freehand (FH) group, clinically acceptable placement (grade A and B) was 40 screws (83.3%), meanwhile 44 screws (91.7%) in the SPC guide group (p = 0.217). The grade A screws in the SPC guide group were much more than that in the FH group (n = 40 vs. n = 31, p = 0.036). The misplacement screws (grade C, D, and E) and proximal facet joint violation (FJV) in the SPC group was comparable to the FH group. CONCLUSIONS: This cadaveric study demonstrate that implanting CBT screws guided by SPC guide was more accuracy and reduces severe deviations in important directions.


Assuntos
Procedimentos Ortopédicos , Parafusos Pediculares , Fusão Vertebral , Humanos , Vértebras Lombares/cirurgia , Osso Cortical/cirurgia , Cadáver
14.
Global Spine J ; 13(6): 1646-1657, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36548436

RESUMO

STUDY DESIGN: Systematic review and meta-analysis. OBJECTIVE: Compilation of complication outcomes data from the surgical management of severe rigid kyphoscoliosis patients using VCR-based vs non-VCR-based corrective maneuvers is lacking. This meta-analysis aimed to compare complication outcomes between those classified osteotomy approaches. METHODS: Thorough literature review and meta-analysis were conducted between January 2000 and September 2021. The selection criteria were studies: i) reporting major curve Cobb angle of ≥80° and flexibility of <25% or 30%; ii) comparing VCR or ≥ Type V Schwab osteotomy defined as VCR-based vs [non-VCR-based] techniques, (any osteotomy or technique other than VCR); iii) published in English with ≥10 patients; iv) reporting complication rates; and v) having minimum of 2-year follow-up. Odds ratios (ORs) and 95% confidence intervals (CIs) were calculated. Significance level was set at (P < .05). RESULTS: Of the 174 patients included, 52.30% (n = 91) and 47.70% (n = 83) were VCR-based and non-VCR-based, respectively. The incidence of dural tears/nerve injuries/significant intraoperative-neuromonitoring changes was significantly higher; [OR = 6.78, CI= (1.75 to 26.17), I2 = 0%, (P = .006)] in the VCR-based group than the non-VCR-based group. The 'overall surgical and medical' complication rate was significantly higher in the VCR-based group, [OR = 1.94, CI= (1.02 to 3.67), I2 = 31%, (P = .04)]. CONCLUSION: Both VCR-based and non-VCR-based surgical techniques for management of severe rigid scoliosis and kyphoscoliosis patients pose comparable overall surgical complication rates, while a significantly higher perioperative neurological complication incidence was associated with VCR-based technique compared to the non-VCR-based techniques. The VCR-based technique was associated with 6.78 times higher incidence of neurological complications compared to non-VCR-based techniques.

15.
BMC Surg ; 22(1): 384, 2022 Nov 08.
Artigo em Inglês | MEDLINE | ID: mdl-36348354

RESUMO

BACKGROUND AND OBJECTIVE: The Cortical Bone Trajectory (CBT) technique provides an alternative method for fixation in the lumbar spine in patients with osteoporosis. An accuracy CBT screw placement could improve mechanical stability and reduce complication rates. PURPOSE: The purpose of this study is to explore the accuracy of cortical screw placement with the application of implanted spinous process clip (SPC) guide. METHODS AND MATERIALS: Four lumbar specimens with T12-S1 were used to access the accuracy of the cortical screw. The SPC-guided planning screws were compared to the actual inserted screws by superimposing the vertebrae and screws preoperative and postoperative CT scans. According to preoperative planning, the SPC guide was adjusted to the appropriate posture to allow the K-wire drilling along the planned trajectory. Pre and postoperative 3D-CT reconstructions was used to evaluate the screw accuracy according to Gertzbein and Robbins classification. Intraclass correlation coefficients (ICCs) and Bland-Altman plots were used to examine SPC-guided agreements for CBT screw placement. RESULTS: A total of 48 screws were documented in the study. Clinically acceptable trajectory (grades A and B) was accessed in 100% of 48 screws in the planning screws group, and 93.8% of 48 screws in the inserted screws group (p = 0.242). The incidence of proximal facet joint violation (FJV) in the planning screws group (2.1%) was comparable to the inserted screws group (6.3%) (p = 0.617). The lateral angle and cranial angle of the planned screws (9.2 ± 1.8° and 22.8 ± 5.6°) were similar to inserted screws (9.1 ± 1.7° and 23.0 ± 5.1°, p = 0.662 and p = 0.760). Reliability evaluated by intraclass correlation coefficients and Bland-Altman showed good consistency in cranial angle and excellent results in lateral angle and distance of screw tip. CONCLUSIONS: Compared with preoperative planning screws and the actually inserted screws, the SPC guide could achieve reliable execution for cortical screw placement.


Assuntos
Parafusos Pediculares , Fusão Vertebral , Humanos , Fusão Vertebral/métodos , Reprodutibilidade dos Testes , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/cirurgia , Cadáver
16.
Front Surg ; 9: 989119, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36277279

RESUMO

Objectives: The optimized enhanced recovery after surgery (ERAS) pathway for adolescent idiopathic scoliosis (AIS) patients has not been comprehensively described. The purpose of the study was to explore the feasibility and efficacy of an integral process of ERAS protocol in posterior spinal fusion (PSF) surgery for AIS patients without three-column osteotomy. Methods: Based on the inclusion and exclusion criteria, a total of 90 AIS patients who underwent PSF were enrolled in the study. Forty-five patients followed a traditional pathway (TP) perioperative care and 45 were treated with an ERAS protocol designed and implemented by a multidisciplinary team. Patient demographic, clinical information, surgical data, and radiographic parameters were collected and analyzed retrospectively. Results: There is no significant difference in age, gender, body mass index, preoperative hemoglobin level, Cobb angle, curve type, average correction rate, fusion segments, and screw number between ERAS group and TP group. Regarding the estimated blood loss (EBL), surgical duration, pain intensity, drainage duration, drainage volume, first ambulation time, postoperative length of stay (LOS), and the incidence of blood transfusion, they were significantly less in ERAS group than those of TP group. Conclusions: Based on our findings, we found that the implementation of a standard ERAS protocol in AIS correction surgery could result in less EBL, lower pain intensity, early ambulation, shorter LOS, and rapid rehabilitation. We recommend the widespread adoption of ERAS protocols in AIS surgery.

17.
Front Surg ; 9: 1000031, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36211282

RESUMO

Background: Low bone mass concomitantly occurs in patients with adolescent idiopathic scoliosis (AIS) and can persist until skeletal maturity. The purpose of this study was to assess the asymmetrical loss of vertebral bone mineral density (vBMD) and its correlation with curve severity in patients with AIS using Hounsfield unit (HU) values measured from computed tomography scans. Methods: A total of 93 AIS patients were retrospectively recruited. The HU values of the vertebral body (VB-HU) and pedicle screw trajectory (PST-HU) were measured from four vertebrae above (Apex - 4) to four below (Apex + 4) the apical vertebra (Apex) of the major curve. The VB-HU and PST-HU at the upper end vertebra, Apex, and lower end vertebra within the concave and convex sides of the major and minor curves and stable vertebrae were obtained. Results: A significant correlation was found between the Cobb angle and VB-HU at the periapical levels of the major curve. VB-HU and PST-HU at periapical levels were significantly greater within the concavity than the convexity of both major and minor curves. The asymmetric ratios of VB-HU and PST-HU were significantly correlated with the major curve Cobb angle, peaked at the apex, and gradually diminished from the apex to the end vertebrae. The asymmetrical loss of vBMD aggravated with the progression of curve severity, presenting as VB-HU, significantly decreased within the convexity and insignificantly decreased within the concavity of the major curve. Conclusion: The asymmetrical loss of vBMD was associated with the progression of curve severity in AIS. For patients with severe AIS, the distraction of the pedicle screws at the concave side should be a priority in correcting the major curve, and supplemental anchors and larger-sized screws should be placed within the convex side around the apex of the major curve to reduce the risk of screw loosening after surgery.

18.
Front Surg ; 9: 950129, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36311946

RESUMO

Purpose: This study aims to investigate the risk factors for screw loosening after single-level posterior lumbar interbody fusion (PLIF) utilizing cortical bone trajectory (CBT) screw and establish a nomogram for predicting screw loosening. Methods: A total of 79 patients (316 screws) who underwent single-level PLIF with CBT screw were included in the study. Preoperative, postoperative, and final follow-up demographic data, surgical data, and radiographic parameters were documented and analyzed to identify risk factors, and a predictive nomogram was established for screw loosening. The nomogram was assessed by concordance index (C-index), calibration plot, decision curve analysis (DCA), and internal validation. Results: The incidence of screw loosening was 26.6% in 79 patients and 11.4% in 316 screws. Multifactorial regression analysis confirmed that fixed to S1 (FS1, OR = 3.82, 95% CI 1.12-12.71, P = 0.029), the coronal angle of the screw (CA, OR = 1.07, 95% CI 1.01-1.14, P = 0.039), and cortical bone contacted layers (CBCLs, OR = 0.17, 95% CI 0.10-0.29, P < 0.001) were risk factors and incorporated in the nomogram for predicting screw loosening after single-level PLIF with a CBT screw. The C-index of the nomogram was 0.877 (95% CI 0.818-0.936), which demonstrated good predictive accuracy. The calibration plot indicated an acceptable calibration of the nomogram that also had a positive benefit in guiding treatment decisions. Conclusion: FS1, CA, and CBCLs are identified to be significant risk factors for screw loosening after single-level PLIF with the CBT technique. The nomogram we have established can be used to predict screw loosening and contribute to surgical decisions.

19.
Front Bioeng Biotechnol ; 10: 978554, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36118572

RESUMO

Objectives: To analyze the stress distribution in the proximal vertebral body and soft tissue of dual growing-rod (GR) with different upper instrumented vertebra (UIV) to determine the optimal UIV. Methods: A ten-year-old male EOS case treated with GR was selected. Based on spiral computed tomography (CT) scanning performed in 0.6 mm thick slices, a finite element model (FEM) of the preoperative state (M0, the original spine state) of the patient was created. Subsequently, four models with different UIV fixations were numerically analyzed by FEM, including M1 (UIV = T1, i.e., the upper-end vertebrae (UEV) of the upper thoracic curve), M2 (UIV = T2), M3 (UIV = T3) and M4 (UIV = T4, i.e., the lower end vertebrae (LEV) of the upper thoracic curve). Displacement and maximum stress in the proximal vertebral body and soft tissue were measured and compared among the five models. Results: The spine model was fixed with the sacrum, and the gravity conditions were imposed on each vertebral body according to the research of Clin and Pearsall. The results are as follows:M4 model has the largest overall displacement, while M1 has the least displacement among the four models. Except M2, the maximum normalized stress of UIV increases with the downward movement of UIV. M1 has the lowerest annulus fibrosus stress and highest joint capsule stress, which is characterized by the vertebrae backward leaning, while M4 is the opposite. The supraspinous ligament stress of M3 and M4 is significantly higher than that of M1 and M2. This suggests that UIV downshift increases the tendency of the proximal vertebral bodies to bend forward, thereby increasing the tension of the posterior ligaments (PL). Conclusion: The UIV of the GR is recommended to be close to the UEV of the upper thoracic curve, which can reduce the stress of the proximal PL, thereby reducing the occurrence of proximal junctional kyphosis (PJK).

20.
Clin Biomech (Bristol, Avon) ; 99: 105763, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-36122528

RESUMO

BACKGROUND: We sought to assess the elasticity change of the paravertebral fascia and muscle in adolescent idiopathic scoliosis patients with Lenke Type 1, 2, or 3 curves after posterior selective fusion surgery. METHODS: The shear wave elasticity imaging system was used to assess the elasticity of the thoracic paravertebral muscles and fascia both on the concave and convex sides. Three regions of interest, including the apex, upper end, and lower end of the main curve, were tested. FINDINGS: Ten female patients, with an average age of 16.6 ± 2.7 years old, were included. The average post-operation follow-up period was 9.0 ± 2.4 months. The Cobb angle was significantly corrected from 63.6 ± 12.0° to 10.7 ± 5.4° (p < 0.05). The length of the trunk increased from 40.4 ± 2.5 cm to 46.0 ± 2.8 cm (p < 0.05). The elasticity of deep fascia didn't show a significant change post-operation (p > 0.05). The elasticity of the paravertebral muscle on the concave side had a significant increase at the final follow-up (p < 0.05). The elasticity of the paravertebral muscle on the convex side also increased at the upper end (p < 0.05). The elasticity asymmetry of the deep fascia decreased, but the elasticity asymmetry of the paravertebral muscle increased at the upper end of the curve (p < 0.05). INTERPRETATION: The paravertebral muscle on the concave side is stiffer after surgery. Elastic asymmetry of paravertebral muscle increased and elastic asymmetry of the deep fascia decreased at the upper end of the curvature. Further study is needed to elucidate the mechanism by which the paravertebral soft tissue responds after surgery.


Assuntos
Cifose , Escoliose , Fusão Vertebral , Adolescente , Adulto , Elasticidade , Fáscia/diagnóstico por imagem , Feminino , Humanos , Músculo Esquelético/diagnóstico por imagem , Estudos Retrospectivos , Escoliose/diagnóstico por imagem , Escoliose/cirurgia , Vértebras Torácicas/cirurgia , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA