Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Front Cell Dev Biol ; 10: 963866, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36438564

RESUMO

Background: Endothelial injury induced by low shear stress (LSS) is an initiating factor in the pathogenesis of various cardiovascular diseases, including atherosclerosis, hypertension, and thrombotic diseases. Low shear stress activates the mammalian target of rapamycin complex 2 (mTORC2) signaling pathway. Rictor, the main constituent protein of mTORC2, is involved in vascular development. However, the impact of conditional Rictor ablation on endothelial homeostasis, especially on endothelial-specific markers, such as vascular endothelial-cadherin (VE-cadherin) and von Willebrand factor (VWF), under blood flow stimulation is unclear. Objective: We aimed to investigate whether endothelial Rictor is involved in maintaining vascular endothelial integrity and the potential role of Rictor in atheroprone blood flow-mediated endothelial injury. Methods and results: Immunofluorescence staining showed that endothelial Rictor was successfully knocked out in a mouse model. Scanning electron microscopy (EM) detection revealed disruption of the endothelial monolayer in the thoracic aorta of Rictor-deficient mice. Furthermore, scanning electron microscopy and transmission electron microscopy showed that Rictor deletion disrupted endothelial integrity and expanded cell junctions in the left common carotid artery region. In vitro, low shear stress disrupted actin filament polarity and the promoted the translocation of vascular endothelial-cadherin, the key component of adherens junctions (AJs) in human umbilical vein endothelial cells. After Rictor downregulation by small interfering RNA, the translocation of vascular endothelial-cadherin and stress fibers increased. Rictor knockdown inhibited low shear stress-induced von Willebrand factor upregulation, and downregulation of vascular endothelial-cadherin decreased low shear stress-induced von Willebrand factor expression. These results suggest that vascular endothelial-cadherin/von Willebrand factor is a possible mechanism mediated by Rictor in the pathological process of low shear stress-induced endothelial injury. Conclusion: Rictor is a key protein that regulates endothelial integrity under vascular physiological homeostasis, and Rictor mediates low shear stress-induced endothelial injury by regulating adherens junctions and von Willebrand factor.

2.
Sci Rep ; 6: 29409, 2016 07 05.
Artigo em Inglês | MEDLINE | ID: mdl-27377422

RESUMO

Detection of coronary ischemic lesions by fractional flow reserve (FFR) has been established as the gold standard. In recent years, novel computer based methods have emerged and they can provide simulation of FFR using coronary artery images acquired from coronary computed tomography angiography (FFRCT). This meta-analysis aimed to evaluate diagnostic performance of FFRCT using FFR as the reference standard. Databases of PubMed, Cochrane Library, EMBASE, Medion and Web of Science were searched. Seven studies met the inclusion criteria, including 833 stable patients (1377 vessels or lesions) with suspected or known coronary artery disease (CAD). The patient-based analysis showed pooled estimates of sensitivity, specificity and diagnostic odds ratio (DOR) for detection of ischemic lesions were 0.89 [95%confidence interval (CI), 0.85-0.93], 0.76 (95%CI, 0.64-0.84) and 26.21 (95%CI, 13.14-52.28). At a per-vessel or per-lesion level, the pooled estimates were as follows: sensitivity 0.84 (95%CI, 0.80-0.87), specificity 0.76 (95%CI, 0.67-0.83) and DOR 16.87 (95%CI, 9.41-30.25). Area under summary receiver operating curves was 0.90 (95%CI, 0.87-0.92) and 0.86 (95%CI, 0.83-0.89) at the two analysis levels, respectively. In conclusion, FFRCT technology achieves a moderate diagnostic performance for noninvasive identification of ischemic lesions in stable patients with suspected or known CAD in comparison to invasive FFR measurement.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Idoso , Angiografia por Tomografia Computadorizada/normas , Doença da Artéria Coronariana/sangue , Feminino , Reserva Fracionada de Fluxo Miocárdico , Humanos , Masculino , Pessoa de Meia-Idade , Razão de Chances , Sensibilidade e Especificidade
3.
Catheter Cardiovasc Interv ; 87 Suppl 1: 589-98, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26876688

RESUMO

OBJECTIVE: This study investigated the diagnostic accuracy of three-dimensional quantitative coronary angiography (3D-QCA) compared with conventional 2D-QCA for predicting functional severity assessed by fractional flow reserve (FFR) for true bifurcation lesions. METHODS: Based on pooled data from the randomized DK-CRUSH II, III, and IV trials, we evaluated the patients with true bifurcation lesions who underwent coronary angiography together with functional evaluations using FFR in both the main vessel and the side branch. Off-line 2D- and 3D-QCA analyses were conducted using dedicated bifurcation QCA analysis software. Measurements of minimum lumen diameter (MLD), percentage diameter stenosis (% DS), and minimum lumen area (MLA) were compared between 2D- and 3D-QCA, and we evaluated their predictive values of functionally significant FFR. RESULTS: Ninety patients were eligible for enrollment in the present study. In the main vessel, MLA measured by 3D-QCA was the most accurate predictor of FFR <0.75 (C statistic 0.85, P < 0.001), while MLD measured by 2D-QCA was a similarly accurate predictor (C statistic 0.85, P < 0.001). In the side branch, the best metrics for predicting FFR <0.75 were % DS measured by 2D-QCA with a C statistic value of 0.91 (P < 0.001) and MLA measured by 3D-QCA with a C statistic value of 0.81 (P < 0.001). However, both 2D- and 3D-QCA metrics exhibited low accuracies for predicting FFR <0.75 in intermediate bifurcation lesions. CONCLUSIONS: 3D-QCA analysis for true bifurcation lesions did not improve the predictive accuracy of functionally significant FFR compared with 2D-QCA analysis. In lesions with intermediate stenosis, the diagnostic performance of both 2D- and 3D-QCA-derived measurements in differentiating functional severity is limited.


Assuntos
Angiografia Coronária/instrumentação , Doença da Artéria Coronariana/diagnóstico por imagem , Estenose Coronária/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Imageamento Tridimensional , Idoso , Ensaios Clínicos Fase IV como Assunto , Doença da Artéria Coronariana/fisiopatologia , Estenose Coronária/fisiopatologia , Vasos Coronários/fisiopatologia , Feminino , Reserva Fracionada de Fluxo Miocárdico , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Interpretação de Imagem Radiográfica Assistida por Computador , Ensaios Clínicos Controlados Aleatórios como Assunto , Reprodutibilidade dos Testes , Índice de Gravidade de Doença , Software
4.
EuroIntervention ; 12(8): e957-e963, 2016 Oct 10.
Artigo em Inglês | MEDLINE | ID: mdl-26690316

RESUMO

AIMS: The study aimed to examine five-year clinical outcomes of complete (CR), partially complete (PCR), and incomplete revascularisation (ICR) in patients with unprotected left main coronary artery (ULMCA) disease treated with drug-eluting stents (DES). Completeness of revascularisation, defined as revascularisation of all vessels ≥1.5 or 2.5 mm in diameter, has been shown to correlate with outcomes after percutaneous coronary intervention (PCI). There are no data to compare revascularisation strategies on long-term clinical outcomes in patients undergoing PCI of ULMCA disease. METHODS AND RESULTS: This prospective registry enrolled 910 consecutive patients with ULMCA disease undergoing PCI with DES implantation. CR included patients who had a successful revascularisation of all diseased segments with diameter ≥1.5 mm. PCR included patients who had successful revascularisation of all diseased segments with diameter ≥2.5 mm. ICR included patients who did not achieve revascularisation for all diseased segments of diameter ≥2.5 mm. The primary endpoint was the incidence of major adverse cardiac events (MACE: a composite of cardiac death, myocardial infarction and repeat revascularisation) at five-year follow-up. CR was achieved in 386 (42.4%), PCR in 227 (25.0%), and ICR in 297 (32.6%) patients. Patients with ICR had a significantly higher rate of MACE (29.6% vs. 22.5% and 15.5%, p<0.001) and all-cause mortality (12.5% vs. 7.0% and 6.2%; p=0.006) than those with CR and PCR at five-year follow-up. After propensity score matching, patients with CR vs. PCR had similar incidences of MACE (hazard ratio [HR]: 1.16, 95% confidence interval [CI]: 0.78-1.74, p=0.46), mortality (HR: 1.27, 95% CI: 0.61-2.63, p=0.53), and cardiac death (1.8% vs. 4.5%; HR: 2.56, 95% CI: 0.80-8.17, p=0.11). On multivariable logistic regression analysis, ICR appears to be an outcome of poor clinical characteristics, comorbidities and complex coronary anatomy. CONCLUSIONS: In the treatment of patients with ULMCA disease, ICR was associated with worse long-term clinical outcomes than CR and PCR. PCR has clinical outcomes similar to CR in patients with ULMCA disease treated with DES.


Assuntos
Doenças Cardiovasculares/mortalidade , Doença da Artéria Coronariana/cirurgia , Stents Farmacológicos , Infarto do Miocárdio/epidemiologia , Revascularização Miocárdica/estatística & dados numéricos , Intervenção Coronária Percutânea/métodos , Sistema de Registros , Fatores Etários , Idoso , Diabetes Mellitus/epidemiologia , Feminino , Humanos , Hipertensão/epidemiologia , Incidência , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Doenças Vasculares Periféricas/epidemiologia , Pontuação de Propensão , Modelos de Riscos Proporcionais , Estudos Prospectivos , Resultado do Tratamento
5.
BMC Cardiovasc Disord ; 15: 153, 2015 Nov 17.
Artigo em Inglês | MEDLINE | ID: mdl-26577590

RESUMO

BACKGROUND: Intravascular ultrasound (IVUS) can be a useful tool during drug-eluting stents (DES) implantation as it allows accurate assessment of lesion severity and optimal treatment planning. However, numerous reports have shown that IVUS guided percutaneous coronary intervention is not associated with improved clinical outcomes, especially in non-complex patients and lesions. METHODS: We searched the literature in Medline, the Cochrane Library, and other internet sources to identify studies that compare clinical outcomes between IVUS-guided and angiography-guided DES implantation. Random-effects model was used to assess treatment effect. RESULTS: Twenty eligible studies with a total of 29,068 patients were included in this meta-analysis. The use of IVUS was associated with significant reductions in major adverse cardiovascular events (MACE, odds ratios [OR] 0.77, 95 % confidence intervals [CI] 0.71-0.83, P < 0.001), death (OR 0.62, 95 % CI 0.54-0.71, p < 0.001), and stent thrombosis (OR 0.59, 95 % CI: 0.47-0.73, P < 0.001). The benefit was also seen in the repeated analysis of matched and randomized studies. In stratified analysis, IVUS guidance appeared to be beneficial not only in patients with complex lesions or acute coronary syndromes (ACS) but also patients with mixed lesions or presentations (MACE: OR 0.69, 95 % CI: 0.60-0.79, p < 0.001, OR 0.81, 95 % CI 0.74-0.90, p < 0.001, respectively). By employing meta-regression analysis, the benefit of IVUS is significantly pronounced in patients with complex lesions or ACS with respect to death (p = 0.048). CONCLUSIONS: IVUS guidance was associated with improved clinical outcomes, especially in patients with complex lesions admitted with ACS. Large, randomized clinical trials are warranted to identify populations and lesion characteristics where IVUS guidance would be associated with better outcomes.


Assuntos
Angiografia Coronária , Doença da Artéria Coronariana/terapia , Vasos Coronários/diagnóstico por imagem , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Ultrassonografia de Intervenção , Idoso , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Razão de Chances , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Valor Preditivo dos Testes , Pontuação de Propensão , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Resultado do Tratamento
6.
Int J Cardiovasc Imaging ; 31(8): 1489-96, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26208685

RESUMO

The study sought to compare long-term optical coherence tomography (OCT)-based in-stent vascular response between the abluminal groove-filled biodegradable polymer sirolimus-eluting stent (SES) and the durable polymer everolimus-eluting stent (EES) in the TARGET I trial. The TARGET I trial was a prospective, multicenter, randomized clinical trial which enrolled 458 patients with single de novo lesions treated by abluminal groove-filled biodegradable polymer SES and EES. A subset of 43 patients underwent angiography and OCT examinations at 3 years. All OCT images were analyzed at 0.4 mm intervals. A similar increase in angiographic late lumen loss was observed in SES and EES (from 0.05 ± 0.05 vs. 0.05 ± 0.05 mm [p = 0.84] at 9 months to 0.25 ± 0.37 vs. 0.26 ± 0.19 mm [p = 0.99] at 3 years, respectively), without significant differences at 3 years in mean neointimal thickness of stent struts (SES: 0.13 ± 0.02 mm vs. EES: 0.13 ± 0.02 mm, p = 0.80); mean percentage of covered struts (SES: 99.2 % vs. EES: 99.3 %, p = 0.53), or malapposed strut rates (SES: 0.08 % vs. EES: 0.06 %, p = 0.15). The OCT-based in-stent vascular response evaluation found similar vascular healing for the two studied devices, indicating that the luminal loss in EES from 9 months to 3 years cannot be imputed on its coated biocompatible polymer.


Assuntos
Implantes Absorvíveis , Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/terapia , Vasos Coronários/efeitos dos fármacos , Stents Farmacológicos , Everolimo/administração & dosagem , Intervenção Coronária Percutânea/instrumentação , Polímeros , Sirolimo/administração & dosagem , Tomografia de Coerência Óptica , Idoso , Fármacos Cardiovasculares/efeitos adversos , China , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/patologia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Everolimo/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Valor Preditivo dos Testes , Estudos Prospectivos , Desenho de Prótese , Sirolimo/efeitos adversos , Fatores de Tempo , Resultado do Tratamento , Remodelação Vascular/efeitos dos fármacos , Cicatrização/efeitos dos fármacos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA