Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
J Synchrotron Radiat ; 31(Pt 2): 378-384, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38241124

RESUMO

An integrated computer software system for macromolecular crystallography (MX) data collection at the BL02U1 and BL10U2 beamlines of the Shanghai Synchrotron Radiation Facility is described. The system, Finback, implements a set of features designed for the automated MX beamlines, and is marked with a user-friendly web-based graphical user interface (GUI) for interactive data collection. The Finback client GUI can run on modern browsers and has been developed using several modern web technologies including WebSocket, WebGL, WebWorker and WebAssembly. Finback supports multiple concurrent sessions, so on-site and remote users can access the beamline simultaneously. Finback also cooperates with the deployed experimental data and information management system, the relevant experimental parameters and results are automatically deposited to a database.

2.
Rev Sci Instrum ; 88(7): 073301, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28764542

RESUMO

The macromolecular crystallography beamlines at third-generation synchrotron facilities play a central role in solving macromolecular crystal structures and also in understanding the biological function at molecular levels. The MX beamline BL17U at Shanghai Synchrotron Radiation Facility is a typical standard MX beamline with a focused beam size (H × V) of FWHM around 80 µm × 45 µm. However the protein samples brought to the beamline are down to 5-10 m from the important and challenging science project now. These samples require smaller size beam. In order to achieve the mini-size beamline, two mini-beam modes have been developed on BL17U: the pinhole-based mini-beam and the focused mini-beam by compound refractive lens (CRL). Compared to the pinhole-based mode, three times increase in flux is obtained by the CRL mode at a similar beam size. The flux gain obtained by the CRL needs to be considered for data collection strategies. It takes few minutes to switch the beamline from the normal to CRL mini-beam mode.

3.
J Synchrotron Radiat ; 23(Pt 6): 1323-1332, 2016 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-27787238

RESUMO

X-ray diffraction is a common technique for determining crystal structures. The average time needed for the solution of a protein structure has been drastically reduced by a number of recent experimental and theoretical developments. Since high-throughput protein crystallography benefits from full automation of all steps that are carried out on a synchrotron beamline, an automatic crystal centring procedure is important for crystallographic beamlines. Fully automatic crystal alignment involves the application of optical methods to identify the crystal and move it onto the rotation axis and into the X-ray beam. Crystal recognition has complex dependencies on the illumination, crystal size and viewing angles due to effects such as local shading, inter-reflections and the presence of antifreezing elements. Here, a rapid procedure for crystal centring with multiple cameras using region segment thresholding is reported. Firstly, a simple illumination-invariant loop recognition and classification model is used by slicing a low-magnification loop image into small region segments, then classifying the loop into different types and aligning it to the beam position using feature vectors of the region segments. Secondly, an edge detection algorithm is used to find the crystal sample in a high-magnification image using region segment thresholding. Results show that this crystal centring method is extremely successful under fluctuating light states as well as for poorly frozen and opaque samples. Moreover, this crystal centring procedure is successfully integrated into the enhanced Blu-Ice data collection system at beamline BL17U1 at the Shanghai Synchrotron Radiation Facility as a routine method for an automatic crystal screening procedure.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA