Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Medicine (Baltimore) ; 103(23): e38372, 2024 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-38847702

RESUMO

To explore the clinical application value of intracavitary electrocardiogram (ECG) localization combined with ultrasound in central venous catheterization in critically ill patients. A total of 103 patients who were treated in the intensive care unit of our hospital from October 2020 to June 2023 were selected as the study subjects, and according to the differences in their central venous catheter placement methods, they were divided into study group (n = 52, receiving ultrasound combined with intracavitary ECG localization for catheterization) and control group (n = 51, receiving routine catheterization). The differences in the catheter placement accuracy, catheter depth, catheter placement duration, incidence of catheter-related complications, length of stay, and hospitalization expenses between the 2 groups were compared. The analysis utilizing X-ray for catheter tip positioning indicated that the catheter tip placement rate was higher in the study group than in the control group, and the catheter tip malposition rate was lower than in the control group (P < .05). There was no statistical significance in the catheter depth between study group and control group (P > .05), and the catheter placement duration of study group was significantly lower than that of control group, with statistical significance (P < .05). One case of partial catheter blockage, one case of catheter-related bloodstream infection, and one case of phlebitis were observed in study group, with an overall incidence of complications of 5.77% (3/52), which was significantly lower than 21.57% (11/51) of control group (P < .05). The length of stay and hospitalization expenses in study group were significantly lower than those in control group, with statistical significance (P < .05). The combined use of ultrasound and intracavitary ECG localization in critically ill patients undergoing central venous catheterization can help increase the success rate of catheter placement, shorten the catheter placement duration, reduce the incidence of various catheter-related complications, and also reduce the length of stay and hospitalization expenses.


Assuntos
Cateterismo Venoso Central , Estado Terminal , Eletrocardiografia , Humanos , Masculino , Feminino , Eletrocardiografia/métodos , Estado Terminal/terapia , Pessoa de Meia-Idade , Cateterismo Venoso Central/métodos , Cateterismo Venoso Central/efeitos adversos , Unidades de Terapia Intensiva , Tempo de Internação/estatística & dados numéricos , Idoso , Ultrassonografia de Intervenção/métodos , Adulto , Ultrassonografia/métodos
2.
J Biomater Sci Polym Ed ; 32(15): 2009-2027, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34338145

RESUMO

In the present study, curcumin loaded chitosan/poly ethylene glycol nanomaterial (CUR loaded CH/PEG/AgNPs) was fabricated and characterized for wound healing efficiency after fracture surgery. The interaction of functional groups and crystal nature were recorded under FTIR and XRD spectrometer and reveals that the stabilization and purity of NPs was mediated by OH/NH2 groups in chitosan. FESEM showed the presence of spherical and well dispersed particles. The average size of the particle was 13.48 nm. The CUR loaded CH/PEG/AgNPs showed higher swelling capacity (495.6 g/g) in phosphate buffer saline compared to water (140.2 g/g). The drug loading efficiency was higher in CUR loaded CH/PEG/AgNPs compared to CH/PEG films as recorded by the absorbance peak at 460 nm corresponds to curcumin in the composite. A dose dependent cytotoxicity of CUR loaded CH/PEG/AgNPs was noticed on Vero cells. The viability of Vero cells was increased to 96.5% at 100 µg/mL. A remarkable change in Vero cells such as condensed nuclei and membrane blabbing was noticed in cells treated with CUR loaded CH/PEG/AgNPs. A greater inhibition of Staphylococcus aureus and Escherichia coli was noticed at 24 h and 48 h treated with CUR loaded CH/PEG/AgNPs. A greater healing effect by increasing the wound contraction (98% on day 12) was observed with CUR loaded CH/PEG/AgNPs compared to control. Histopathological examination demonstrated that CUR loaded CH/PEG/AgNPs showed complete tissue regeneration in wound excised rats. The results of this study conclude that CUR loaded CH/PEG/AgNPs could be promising candidate to prevent microbial infections in wound, healing wound rapidly and inhibit the proliferation of apoptotic cells. Thus, CUR loaded CH/PEG/AgNPs could be a potential therapeutic agent with broad spectrum applications in the future.HighlightsA new approach was used to develop curcumin-loaded chitosan/poly(ethylene glycol)/AgNPs.The CUR-loaded CH/PEG/AgNPs were confirmed to be crystals by XRD analysis.The prepared CH/PEG/AgNPs were spherical and averaged 13.48 nm in size.The growth of S. aureus and E. coli were inhibited mostly by CH/PEG/AgNPs treatment.CUR loaded CH/PEG/AgNPs showed complete tissue regeneration in wound excised mice.


Assuntos
Nanopartículas , Staphylococcus aureus , Animais , Bandagens , Chlorocebus aethiops , Escherichia coli , Camundongos , Ratos , Células Vero
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA