RESUMO
OBJECTIVES: This study was aimed to compare the stability of stainless steel and titanium miniscrew implants of the same diameter and length during en masse retraction of maxillary and mandibular anterior teeth. MATERIALS AND METHODS: Forty miniscrew implants (1.3 mm diameter and 8 mm length) were placed in 10 patients (20 titanium and 20 stainless steel). Stability was checked at insertion (T0), at one month (T1), and at sixth months (T2) and the amount of retraction was recorded in millimeters. RESULTS: Titanium and stainless steel implants were equally stable at the time of insertion. At T1, three titanium miniscrew implants showed grade 2 mobility, whereas seven stainless steel miniscrew implants showed grade 2 mobility. For T2, none of the titanium miniscrew implants had grade 2 mobility while four stainless steel miniscrew implants resulted in grade 2 mobility. Both had an equal frequency of grade 3 and grade 4 mobility. However, the difference in the stability was not statistically significant. No statistical significance was found when the amount of retraction achieved by titanium and stainless steel miniscrew implants was compared between the maxillary and mandibular arches. CONCLUSION: Both titanium and stainless steel miniscrew implants provide good anchorage and remain stable during en masse retraction of maxillary and mandibular anterior teeth. Thus, both miniscrews are clinically effective.
RESUMO
Depression is one of the significant mental health issues affecting all age groups globally. While it has been widely recognized to be one of the major disease burdens in populations, complexities in definitive diagnosis present a major challenge. Usually, trained psychologists utilize conventional methods including individualized interview assessment and manually administered PHQ-8 scoring. However, heterogeneity in symptomatic presentations, which span somatic to affective complaints, impart substantial subjectivity in its diagnosis. Diagnostic accuracy is further compounded by the cross-sectional nature of sporadic assessment methods during physician-office visits, especially since depressive symptoms/severity may evolve over time. With widespread acceptance of smart wearable devices and smartphones, passive monitoring of depression traits using behavioral signals such as speech presents a unique opportunity as companion diagnostics to assist the trained clinicians in objective assessment over time. Therefore, we propose a framework for automated depression classification leveraging alterations in speech patterns in the well documented and extensively studied DAIC-WOZ depression dataset. This novel tensor-based approach requires a substantially simpler implementation architecture and extracts discriminative features for depression recognition with high f1 score and accuracy. We posit that such algorithms, which use significantly less compute load would allow effective onboard deployment in wearables for improve diagnostics accuracy and real-time monitoring of depressive disorders.
Assuntos
Depressão , Dispositivos Eletrônicos Vestíveis , Algoritmos , Estudos Transversais , Depressão/diagnóstico , FalaRESUMO
Introduction: Prolotherapy is a nonsurgical regenerative injection technique and effective treatment method for the treatment of temporomandibular joint (TMJ) dislocation. Autologous blood and dextrose are commonly used agents for prolotherapy and the aim of this study is to compare the autologous blood injection prolotherapy and 25% dextrose prolotherapy for the treatment of chronic recurrent TMJ dislocation. Method: This is a retrospective cohort study of 20 patients with chronic recurrent TMJ dislocation who were treated by either autologous blood (Group A) or 25% dextrose Prolotherapy (Group B). After prolotherapy, the patients were kept on follow-up and evaluated for maximum mouth opening (MMO), pain at visual analog scale (VAS), mandibular movements, frequency of dislocation, and TMJ sound. The collected data were then statistically analyzed. Results: Group A showed better results in terms of reduction in MMO, mandibular movements as compared to Group B, and a statistically significant difference was found starting from 2 weeks post prolotherapy till 6 months follow-up. Whereas group B showed better results regarding reduction in pain intensity on VAS Scale at all follow-up visits. No statistically significant difference was found between both groups regarding reduction in the frequency of dislocation and TMJ sounds. Conclusion: Both autologous and dextrose prolotherapy gives promising results for the treatment of recurrent TMJ dislocation, however, regarding reduction in MMO and improvement in lateral and protrusive mandibular movements, autologous blood gave better results whereas 25% Dextrose was found to be more effective in terms of reduction of pain in recurrent TMJ dislocation cases.
RESUMO
PURPOSE: We describe the piezo-osteotomy feasibility in rehabilitation and harvesting of osteo-odonto lamina in modified osteo-odonto keratoprosthesis (MOOKP) surgery. Surgery was evaluated regarding operative technique and success of the keratoprosthesis (KPros) in terms of perception to light (+ve) to finger counting (+ve). MATERIALS AND METHODS: This retrospective cohort study included 12 patients undergone MOOKP surgery procedures. Harvesting of osteo-odonto-lamina was performed using piezosurgical osteotomy during 2007-2012. RESULTS: The mean follow up was 34 months (range 24-48 months). Of the 12 patients six patients had vision ≥6/12, four patients had vision <6/12, but >6/60 and one patients had vision ≤6/60. KPros was retained and functional in all the eyes after a minimum follow up of 24 months. There was mucosal overgrowth over the optical cylinder occurred in two cases over 4 years follow up which was corrected with trimming. Postoperative complication at donor site was seen in three cases, two cases with exposure of root of adjacent teeth and oro antral fistula in one. CONCLUSIONS: This study suggests that piezoelectric harvest of osteo-odonto-lamina is a valuable surgical option in patients undergoing MOOKP surgery, resulting in high success rate with less complication.
RESUMO
BACKGROUND: Relapse of pain during refeeding in acute pancreatitis may have a relation to the route of refeeding. AIM: To compare the efficacy of oral refeeding with jejunal tube refeeding in patients with acute pancreatitis, and determine the frequency of refeeding pain and factors associated with it. METHODS: Consecutive patients with acute pancreatitis, severe enough to stop oral feeding for 48 hours, were randomized to receive either oral or jejunal tube refeeding. The feeds were similar in calorie, lipid and protein content (400 Kcal on day 1, 1000 Kcal on day 2, 1400 Kcal on day 3, 1500 Kcal on day 4, and 1700 Kcal on day 5). Clinical and biological factors (serum amylase, lipase, C-reactive protein) and Balthazar CT severity index were recorded. Frequency of pain relapse and factors associated with it were analyzed. RESULTS: 28 patients with acute pancreatitis (biliary 14, alcohol 9, idiopathic 3, post-ERCP 2) were included. Fifteen patients received oral and 13 received enteral tube refeeding. Four patients in the oral group and none in the enteral tube group had relapse of pain (p=0.06). The factors associated with refeeding pain were longer duration of initial pain (p<0.02) and higher CT severity index (p<0.02). Pain relapse increased the total hospital stay (p<0.004) and hospital stay after the first attempt at feeding (p<0.001). CONCLUSIONS: Jejunal tube refeeding may reduce the frequency of pain relapse as compared to oral refeeding although the difference was not significant in this study. Longer duration of pain and higher CT severity index score were associated with occurrence of refeeding pain.