Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Invest Ophthalmol Vis Sci ; 65(5): 20, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38727692

RESUMO

Purpose: Vision-degrading myodesopsia (VDM) from vitreous floaters significantly degrades vision and impacts visual quality of life (VQOL), but the relationship to light scattering is poorly understood. This study compared in vitro measures of light scatter and transmission in surgically excised human vitreous to preoperative indexes of vitreous structure, visual function, and VQOL. Methods: Pure vitreous collected during vitrectomy from 8 patients with VDM had wide-angle straylight measurements and dark-field imaging, performed within 36 hours of vitrectomy. Preoperative VQOL assessment with VFQ-25, contrast sensitivity (CS) measurements with Freiburg acuity contrast testing, and quantitative ultrasonography were compared to light scattering and transmission in vitro. Results: All indices of vitreous echodensity in vivo correlated positively with straylight at 0.5° (R = 0.708 to 0.775, P = 0.049 and 0.024, respectively). Straylight mean scatter index correlated with echodensity (R = 0.71, P = 0.04) and VQOL (R = -0.82, P = 0.0075). Dark-field measures in vitro correlated with degraded CS in vivo (R = -0.69, P = 0.04). VQOL correlated with straylight mean scatter index (R = -0.823, P = 0.012). Conclusions: Increased vitreous echodensity in vivo is associated with more straylight scattering in vitro, validating ultrasonography as a clinical surrogate for light scattering. Contrast sensitivity in vivo is more degraded in the presence of dark-field scattering in vitro and VQOL is decreased in patients whose vitreous has increased light scattering. These findings could form the basis for the development of optical corrections for VDM or support new laser treatments, as well as novel pharmacotherapy.


Assuntos
Sensibilidades de Contraste , Luz , Espalhamento de Radiação , Acuidade Visual , Vitrectomia , Corpo Vítreo , Humanos , Corpo Vítreo/diagnóstico por imagem , Feminino , Masculino , Pessoa de Meia-Idade , Acuidade Visual/fisiologia , Sensibilidades de Contraste/fisiologia , Idoso , Qualidade de Vida , Transtornos da Visão/fisiopatologia , Adulto , Ultrassonografia , Oftalmopatias/fisiopatologia , Oftalmopatias/diagnóstico por imagem
2.
Biomed Opt Express ; 15(2): 608-623, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38404335

RESUMO

Adaptive optics visual simulation is a powerful tool for vision testing and evaluation. However, the existing instruments either have fixed tabletop configurations or, being wearable, only offer the correction of defocus. This paper proposes a novel head-mounted adaptive optics visual simulator that can measure and modify complex ocular aberrations in real-time. The prototype is composed of two optical modules, one for the objective assessment of aberrations and the second for wavefront modulation, all of which are integrated into a wearable headset. The device incorporates a microdisplay for stimulus generation, a liquid crystal on silicon (LCoS) spatial light modulator for wavefront manipulation, and a Hartmann-Shack wavefront sensor. Miniature optical components and optical path folding structures, together with in-house 3D printed mounts and housing, were adapted to realize the compact size. The system was calibrated by characterizing and compensating the internal aberrations of the visual relay. The performance of the prototype was analyzed by evaluating the measurement and compensation of low-order and higher-order aberrations induced through trial lenses and phase masks in an artificial eye. The defocus curves for a simulated bifocal diffractive lens were evaluated in real eyes. The results show high accuracy while measuring and compensating for the induced defocus, astigmatism, and higher-order aberrations, whereas the MTF analysis shows post-correction resolution of up to 37.5 cycles/degree (VA 1.25). Moreover, the subjective test results show the defocus curves closely matched to a commercial desktop visual simulator.

3.
Biomed Opt Express ; 14(2): 639-650, 2023 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-36874487

RESUMO

Cataracts increase the amount of scattered light in the crystalline lens producing low-contrast retinal images and causing vision impairment. The Optical Memory Effect is a wave correlation of coherent fields, which can enable imaging through scattering media. In this work, we characterize the scattering properties of excised human crystalline lenses by measuring their optical memory effect and other objective scattering parameters, finding the relationship between them. This work has the potential to help fundus imaging techniques through cataracts as well as the non-invasive correction of vision through cataracts.

4.
Biomed Opt Express ; 13(4): 2174-2185, 2022 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-35519252

RESUMO

Cataract is one of the common causes of visual impairment due to opacification of the crystalline lens. Increased intraocular scattering affects the vision of cataract patients by reducing the quality of the retinal image. In this study, an amplitude modulation-based scatter compensation (AM-SC) method is developed to minimize the impact of straylight on the retinal image. The performance of the AM-SC method was quantified by numerical simulations of point spread function and retinal images in the presence of different amounts of straylight. The approach was also experimentally realized in a single-pass system with a digital micro-mirror device used as a spatial amplitude modulator. We showed that the AM-SC method allows to enhance contrast sensitivity in the human eyes in vivo with induced scattering.

5.
Opt Express ; 28(23): 34180-34189, 2020 Nov 09.
Artigo em Inglês | MEDLINE | ID: mdl-33182893

RESUMO

Spatial Light Modulators (SLMs) are widely used in several fields of optics such as adaptive optics. SLMs based on Liquid Crystal (LC) devices allow a dynamic and easy representation of two-dimensional phase maps. A drawback of these devices is their elevated cost, preventing a massive use of the technology. We present a more affordable approach based on the serial arrangement of vertical aligned LC devices, with characteristics of phase modulation similar to a widely used parallel aligned LC device. We discuss the peculiarities of the approach, the performance and some potential areas of applications.

6.
Opt Express ; 26(26): 33565-33574, 2018 Dec 24.
Artigo em Inglês | MEDLINE | ID: mdl-30650789

RESUMO

Light scattering limits the penetration depth of non-invasive Raman spectroscopy in biological media. While safe levels of irradiation may be adequate to analyze superficial tissue, scattering of the pump beam reduces the Raman signal to undetectable levels deeper within the tissue. Here we demonstrate how wavefront shaping techniques can significantly increase the Raman signal at depth, while keeping the total irradiance constant, thus increasing the amount of Raman signal available for detection.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA