Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
J Environ Radioact ; 270: 107297, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37738760

RESUMO

The paper describes a new method for the rapid determination of Technetium (Tc) in sediment samples using solid-phase extraction chromatography (SPEC) with a novel methyl triphenyl phosphoniumnitrate (MTPN) resin. The effectiveness of the resin in selectively recovering Tc was evaluated in both batch and column mode and exploited for rapid analysis of 'Tc'. The procedure involves the acid digestion of samples, pre-concentration of fission products in supernatant and co-precipitation of actinides with Fe(OH)3, followed by selective recovery of Tc by SPEC using a column filled with MTPN resin. The recovered Tc was then radiometrically assayed using beta counting. The method was validated using IAEA certified reference materials and was found to provide reliable and reproducible results for the activity concentration of Tc-99 in sediment samples within 24 h.


Assuntos
Elementos da Série Actinoide , Monitoramento de Radiação , Tecnécio , Cromatografia
2.
J Environ Radioact ; 234: 106620, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33984799

RESUMO

The paper reports a new rapid radioanalytical procedure for the determination of plutonium (Pu) in sediments by solid phase extraction chromatography (SPEC) using Bis-(2-ethylhexyl) carbamoyl methoxy phenoxy-bis-(2-ethylhexyl) grafted resin, abbreviated as Benzodioxodiamide (BenzoDODA) grafted resin. The resin was synthesized and evaluated for its sorption behaviour towards Pu in batch and column mode to determine its efficacy for selective recovery of Pu from sediment samples. The analytical procedure was based on the radiochemical separation of samples by acid digestion, followed by preconcentration of actinides by co-precipitation with Fe(OH)3 and finally selective recovery of Pu by SPEC using a column filled with BenzoDODA grafted resin. Pu was then radiometrically assayed by preparing alpha disc sources with electro-deposition followed by alpha spectrometry. The method was further validated with IAEA reference materials. This method gives reliable and reproducible results for the activity concentration of Pu in sediment samples within 24 h.


Assuntos
Elementos da Série Actinoide , Plutônio , Monitoramento de Radiação , Cromatografia , Plutônio/análise , Análise Espectral
3.
Appl Radiat Isot ; 107: 133-137, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26492324

RESUMO

A method has been standardized for restoring a shifted differential pulse height spectrum from a scintillator based gamma ray spectrometer recorded at measurement temperature, to the position of a desired spectrum, recorded at a reference temperature. The method is based on the assumption that the spectrum obtained at measurement temperature represents the same statistical distribution as that at reference temperature but with different energy scales. A computer program has been developed for calculation of the transformation between the energy scales and for the restoration of the shifted spectrum. The method developed has been successfully applied for the restoration of gamma spectra measured at different temperatures.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA