Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
5.
Ann Pediatr Cardiol ; 16(1): 41-44, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37287840

RESUMO

The impact of a dilated left ventricular (LV) on right ventricular (RV) diastolic function has not been investigated. We hypothesized that in patients with a patent ductus arteriosus (PDA), LV dilation causes elevation of the RV end-diastolic pressure (RVEDP) through ventricular-ventricular interaction. We identified patients' ages 6 months to 18 years who underwent transcatheter PDA closure at our center from 2010 to 2019. One hundred and thirteen patients were included with a median age of 3 years (0.5-18). The median LV end-diastolic dimension (LVEDD) Z-score was 1.6 (-1.4-6.3). RVEDP was positively associated with RV systolic pressure (0.38, P < 0.01), ratio of pulmonary artery/aortic systolic pressure (0.4, P < 0.01), and pulmonary capillary wedge pressure (0.71, P < 0.01). RVEDP was not associated with LVEDD Z-score (0.03, P = 0.74). In children with a PDA, RVEDP was not associated with LV dilation, but was positively associated with RV systolic pressure.

6.
Pediatr Cardiol ; 44(7): 1520-1528, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37289278

RESUMO

The objective of this study was to assess the relationship of prenatal diagnosis of critical congenital heart disease (CHD) to preoperative and postoperative patient findings. Retrospective analysis of neonates with critical CHD who underwent cardiothoracic surgery at one of four centers in North Carolina between 2008 and 2013. Surgical data collected by sites for submission to the Society of Thoracic Surgeons Congenital Heart Surgery Database (STS-CHSD) and the North Carolina CHD Lifespan Database were queried. There were 715 patients with STS records; 558 linked to the NC-CHD database. Patients with prenatal diagnosis had a lower incidence of preoperative risk factors, including need for mechanical ventilation and presence of shock. However, prenatally diagnosed patients had worse short-term outcomes, including higher operative mortality, higher incidence of select postoperative complications, and longer LOS. There was no difference in one-year mortality. Our findings are consistent with current literature which suggests that prenatal diagnosis of critical CHD is associated with a more optimized preoperative clinical status. However, we found that patients with prenatal diagnoses had less favorable postoperative outcomes. This needs to be investigated further, but may be secondary to patient-specific factors, such as CHD disease severity.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Cardiopatias Congênitas , Recém-Nascido , Gravidez , Feminino , Humanos , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Cardiopatias Congênitas/diagnóstico , Cardiopatias Congênitas/cirurgia , Estudos Retrospectivos , Diagnóstico Pré-Natal , Fatores de Risco
7.
Pediatr Cardiol ; 44(2): 472-478, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36454266

RESUMO

Children with congenital heart defects (CHDs) are at risk for poor academic performance. The degree to which receipt of health care services is associated with adverse academic outcomes is not known. We examined the association between episodes of cardiac care and third-grade performance in children with CHD. We identified subjects between 1/1/2008 and 4/30/2012 among 5 centers in North Carolina. We classified children by CHD type and linked subjects to the state educational records. Any inpatient or outpatient cardiac encounter on a date of service was considered an encounter. We calculated the number of encounters by adding the number of inpatient or outpatient cardiac visits prior to the date of the end-of-grade (EOG) tests. We estimated the odds of failing third-grade reading or math EOG tests by episodes of care stratified at the 50th percentile, controlling for CHD type, maternal education, sex, race/ethnicity, birth weight, and gestational age. A total of 184 children had third-grade EOG scores linked to health care records. The median number of episodes of care was 4 (range: 1-60). Those with visits ˃ 50th percentile (> 4 encounters/year over the 4.3 year observation period) had 2.09 (95% CI 1.04, 4.21) greater odds of failing the math EOG compared to those ≤ 50th percentile (1-4 encounters). The third-grade math score declined by 1.5 points (P < 0.008) for every 10 episodes of care. There was no association of episodes of care on third-grade reading performance. Children with CHD with > 4 episodes of cardiac care/year may be at risk for delays in third-grade academic performance. Strategies to minimize school absenteeism may improve academic success in this population.


Assuntos
Desempenho Acadêmico , Cardiopatias Congênitas , Humanos , Criança , Escolaridade , Cardiopatias Congênitas/epidemiologia , Cardiopatias Congênitas/terapia , Instituições Acadêmicas , North Carolina/epidemiologia
8.
Ann Pediatr Cardiol ; 16(4): 260-265, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38343508

RESUMO

Background: Changes in left ventricular (LV) systolic function have not been well described in premature neonates after transcatheter patent ductus arteriosus (PDA) closure. Methods and Results: We retrospectively identified all premature neonates < 3 kg who underwent a transcatheter PDA closure at our center between January 1 2015 and January 31, 2021. LV indices before and after closure were extracted and an analysis was performed. Overall, 23 neonates were included with a mean procedural weight of 1894 ± 622 g. At 24 h after closure, the median left ventricular ejection fraction (LVEF) (66% interquartile range [IQR] 12% vs. 61% IQR 12, P< 0.001) and median LV end-diastolic dimension z-score (3.3 IQR 1.8 vs. 1.4 IQR 2.6, P < 0.001) both decreased and 5 (22%) neonates had an LVEF <55%. Patients who had an LVEF <55% at 24 h had a higher preprocedure LV end-diastolic dimension z-score (4.2 IQR 1.2 vs. 2.8 IQR 1.6, P = 0.01), a higher preprocedure LV end-diastolic volume (19 mL IQR 4 mL vs. 11 mL IQR 11, P = 0.03), a higher birth weight (940 g IQR 100 g vs. 760 g IQR 140, P = 0.04), and were more likely to receive intravenous calcium during the procedure (60% vs. 11%, P = 0.04) compared to those with an LVEF ≥55% at 24 h after closure. Of those with LVEF <55% at 24 h, all normalized before discharge. Conclusion: In preterm neonates who underwent successful transcatheter PDA closure, 23% developed abnormal LVEF after closure and those with significant LV dilation before the procedure were at increased risk for the development of LVEF <55% after closure.

9.
Cardiol Young ; 32(8): 1296-1301, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34617506

RESUMO

INTRODUCTION: Systemic ventricular end-diastolic pressure is an important haemodynamic variable in adult patients with Fontan circulation. Risk factors associated with elevated end-diastolic pressure have not been clearly identified in this population. METHODS: All patients > 18 years with Fontan circulation who underwent cardiac catheterisation at our centre between 1/08 and 3/19 were included. Relevant patient variables were extracted. Univariate and multivariate general linear models were analysed to identify variables associated with end-diastolic pressure. RESULTS: Forty-two patients were included. Median age was 24.0 years (20.9-29.0) with a body mass index of 23.7 kg/m2 (21.5-29.7). 10 (23.8%) patients had a systemic right ventricle. The median (Interquartile range) and mean pulmonary artery pressure were 11.0 mmHg (9.0-12.0) and 16.0 mmHg (13.0-18.0), respectively. On univariate analysis, end-diastolic pressure was positively associated with body mass index (p < 0.01), age > 25 years (p = 0.04), symptoms of heart failure (p < 0.01), systemic ventricular systolic pressure (p = 0.03), pulmonary artery mean pressure (p < 0.01), and taking diuretics (p < 0.01) or sildenafil (p < 0.01). End-diastolic pressure was negatively associated with aortic saturation (p < 0.01). On multivariate analysis, end-diastolic pressure was positively associated with age ≥ 25 years (p < 0.01), and body mass index (p = 0.04). CONCLUSIONS: In a cohort of adult patients with Fontan circulation undergoing catheterisation, end-diastolic pressure was positively associated with age ≥ 25 years and body mass index on multivariate analysis. Maintaining a healthy body mass index may offer haemodynamic benefit in adults with Fontan physiology.


Assuntos
Técnica de Fontan , Cardiopatias Congênitas , Adulto , Pressão Sanguínea/fisiologia , Índice de Massa Corporal , Diástole , Técnica de Fontan/efeitos adversos , Cardiopatias Congênitas/diagnóstico , Humanos , Estudos Retrospectivos , Pressão Ventricular/fisiologia , Adulto Jovem
10.
Pediatr Cardiol ; 42(6): 1308-1315, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33890132

RESUMO

With improved surgical outcomes, infants and children with congenital heart disease (CHD) may die from other causes of death (COD) other than CHD. We sought to describe the COD in youth with CHD in North Carolina (NC). Patients from birth to 20 years of age with a healthcare encounter between 2008 and 2013 in NC were identified by ICD-9 code. Patients who could be linked to a NC death certificate between 2008 and 2016 were included. Patients were divided by CHD subtypes (severe, shunt, valve, other). COD was compared between groups. Records of 35,542 patients < 20 years old were evaluated. There were 15,277 infants with an annual mortality rate of 3.5 deaths per 100 live births. The most frequent COD in infants (age < 1 year) were CHD (31.7%), lung disease (16.1%), and infection (11.4%). In 20,265 children (age 1 to < 20 years), there was annual mortality rate of 9.7 deaths per 1000 at risk. The most frequent COD in children were CHD (34.2%), neurologic disease (10.2%), and infection (9.5%). In the severe subtype, CHD was the most common COD. In infants with shunt-type CHD disease, lung disease (19.5%) was the most common COD. The mortality rate in infants was three times higher when compared to children. CHD is the most common underlying COD, but in those with shunt-type lesions, extra-cardiac COD is more common. A multidisciplinary approach in CHD patients, where development of best practice models regarding comorbid conditions such as lung disease and neurologic disease could improve outcomes in this patient population.


Assuntos
Causas de Morte/tendências , Cardiopatias Congênitas/mortalidade , Adolescente , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , North Carolina/epidemiologia , Adulto Jovem
11.
Catheter Cardiovasc Interv ; 97(6): E826-E829, 2021 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-33665931

RESUMO

An infant with ductal dependent pulmonary blood flow who underwent neonatal ductal stenting and, 4 months later, developed ductal stent endocarditis due to Streptococcus gallolyticus subsp. pasteurianus was described. The infection was associated with a moderate aortic pseudoaneurysm and the patient was treated with antibiotics as well as surgical aortic pseudoaneurysm repair. This novel and unusual complication of ductal stent placement warrants reporting.


Assuntos
Falso Aneurisma , Endocardite , Falso Aneurisma/diagnóstico por imagem , Falso Aneurisma/etiologia , Falso Aneurisma/cirurgia , Humanos , Lactente , Recém-Nascido , Stents , Streptococcus , Resultado do Tratamento
12.
Cardiol Young ; 31(10): 1644-1650, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33686934

RESUMO

INTRODUCTION: Systemic ventricular end-diastolic pressure is important in patients with single ventricle heart disease. Predictors of an elevated systemic ventricular end-diastolic pressure prior to bidirectional Glenn operation have been incompletely identified. METHODS: All patients who underwent bidirectional Glenn operation operation at our centre between January 2007 and March 2017 were retrospectively identified and patient variables were extracted. For patients who had undergone Fontan operation at the time of this study, post-Fontan patient variables were also extracted. RESULTS: One-hundred patients were included with a median age at pre-bidirectional Glenn operation catheterisation of 4.5 months. In total, 71 (71%) patients had a systemic right ventricle. At the pre-bidirectional Glenn operation catheterisation, the mean systemic ventricular end-diastolic pressure was higher amongst those with systemic right ventricle compared to left ventricle (9.1 mmHg ± 2.1 versus 7.7 ± 2.7 mmHg, p < 0.01). On univariate analysis, pre-bidirectional Glenn operation systemic ventricular end-diastolic pressure was positively associated with the presence of a systemic right ventricle (p < 0.01), history of recoarctation (p = 0.03), history of Norwood operation (p = 0.04), and ventricular systolic pressure (p < 0.01). On multivariate analysis, systemic ventricular end-diastolic pressure was positively associated with the presence of a systemic right ventricle (p < 0.01) and ventricular systolic pressure (p < 0.01). Amongst those who had undergone Fontan operation at the time of study (n = 49), those with a higher pre-bidirectional Glenn operation systemic ventricular end-diastolic pressure were more likely to have experienced death, transplantation, or listed for transplantation (p = 0.02) and more likely to have had heart failure symptoms (p = 0.04) at a mean time from Fontan of 5.2 years ± 1.3. CONCLUSIONS: In patients undergoing bidirectional Glenn operation operation, the volume-loaded, pre-bidirectional Glenn operation state may expose diastolic dysfunction that has prognostic value.


Assuntos
Técnica de Fontan , Procedimentos de Norwood , Pressão Sanguínea , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/cirurgia , Humanos , Lactente , Estudos Retrospectivos , Resultado do Tratamento , Pressão Ventricular
13.
J Am Heart Assoc ; 9(14): e016400, 2020 07 21.
Artigo em Inglês | MEDLINE | ID: mdl-32654582

RESUMO

Background Little is known about the contemporary mortality experience among adults with congenital heart disease (CHD). The objectives of this study were to assess the age at death, presence of cardiovascular comorbidities, and most common causes of death among adults with CHD in a contemporary cohort within the United States. Methods and Results Patients with CHD who had a healthcare encounter between 2008 and 2013 at 1 of 5 comprehensive CHD centers in North Carolina were identified by International Classification of Diseases, Ninth Revision (ICD-9), code. Only patients who could be linked to a North Carolina death certificate between 2008 and 2016 and with age at death ≥20 years were included. Median age at death and underlying cause of death based on death certificate data were analyzed. The prevalence of acquired cardiovascular risk factors was determined from electronic medical record data. Among the 629 included patients, the median age at death was 64.2 years. Those with severe CHD (n=157, 25%), shunts (n=202, 32%), and valvular lesions (n=174, 28%) had a median age at death of 46.0, 65.0, and 73.3 years, respectively. Cardiovascular death was most common in adults with severe CHD (60%), with 40% of those deaths caused by CHD. Malignancy and ischemic heart disease were the most common causes of death in adults with nonsevere CHD. Hypertension and hyperlipidemia were common comorbidities among all CHD severity groups. Conclusions The most common underlying causes of death differed by lesion severity. Those with severe lesions most commonly died from underlying CHD, whereas those with nonsevere disease more commonly died from non-CHD causes.


Assuntos
Causas de Morte , Cardiopatias Congênitas/mortalidade , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Comorbidade , Feminino , Humanos , Masculino , North Carolina/epidemiologia , Fatores de Risco
14.
Catheter Cardiovasc Interv ; 95(7): 1296-1304, 2020 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-32108423

RESUMO

OBJECTIVE: To evaluate safety and efficacy of the GORE® CARDIOFORM Septal Occluder for percutaneous transcatheter closure of ostium secundum atrial septal defects. BACKGROUND: The GORE® CARDIOFORM septal occluder is a double-disc, low profile, soft, conformable device, with distinct advantages over the GORE® HELEX® Septal Occluder. METHODS: Subjects were enrolled in this single arm prospective study from 21 U.S. sites, and followed for 3 years. Primary endpoint was 6 month composite clinical success, comprised of technical success (implantation and retention of device), closure success (normalization of right heart size), no 30 day serious adverse events, and no device embolization or reintervention. Secondary endpoints included technical success, procedure success (technical success and ≤ 2 mm residual shunt at procedure conclusion), closure success (clinically insignificant or no residual shunt), and safety (freedom from 30 day serious adverse events and 6-month device events). RESULTS: Between October 2012 and May 2015, 50 pivotal and 350 continued access subjects underwent attempted transcatheter GORE® CARDIOFORM Septal Occluder implantation. Median age was 6.9 years, and mean static defect diameter 9.7 ± 3.1 mm. Device placement was achieved in 93.5% (374/400). Composite clinical success was 90.2% and clinical closure success was 98.8% at 6 months. Freedom from serious adverse events was 98.3% at 30 days, with no device embolizations or reinterventions through 6 months. CONCLUSIONS: The GORE® CARDIOFORM Septal Occluder has high composite clinical success and safety, performing well in defects ≤17 mm by stop flow stretched diameter. Single, multifenestrated, and deficient retroaortic tissue defects were well represented and successfully treated.


Assuntos
Cateterismo Cardíaco/instrumentação , Comunicação Interatrial/terapia , Dispositivo para Oclusão Septal , Adolescente , Adulto , Idoso , Cateterismo Cardíaco/efeitos adversos , Criança , Pré-Escolar , Feminino , Comunicação Interatrial/diagnóstico por imagem , Humanos , Lactente , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Desenho de Prótese , Fatores de Tempo , Resultado do Tratamento , Estados Unidos , Adulto Jovem
15.
Catheter Cardiovasc Interv ; 95(7): 1285-1295, 2020 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-31943749

RESUMO

OBJECTIVE: Assess clinical performance of a new device for transcatheter closure of atrial septal defect (ASD). BACKGROUND: Previously-approved ASD Closure devices have known limitations. Device erosion has been associated with the AMPLATZER® septal occluder in patients with retro-aortic rim deficiency (<5 mm), while defects ≥18 mm are too large for the GORE® CARDIOFORM septal occluder. The GORE® CARDIOFORM ASD occluder (GCA), a hybrid of the approved devices, was designed to expand the eligible ASD population. METHODS: One-hundred and twenty-five ASD patients were enrolled in a prospective, multicenter registry. Descriptive clinical endpoints included: technical implant success, closure success, serious adverse events (SAE), clinically significant new arrhythmia, and wire frame fracture. Procedural outcomes and adverse events were adjudicated by an Echocardiography Core Lab and Independent Data Review Board, respectively. RESULTS: Median subject age was 12.3 years (range 2.9-84.7), with 72% of patients ≤18 years old. Median ASD stop-flow diameter was 17.0 mm (8.0-30.0), with 43% ≥18 mm. Deficient retro-aortic rim occurred in 57% of subjects, and 30% had both diameter ≥ 18 mm and deficient rim. Technical Implant Success was achieved in 120/125 (96%), though three devices were removed within 24 hr. At the scheduled 6-month evaluation, 112/117 returned for evaluation. All 112 had closure success. SAE occurred in 6/125 (4.8%) and 6/125 (4.8%) had clinically significant new arrhythmia. Wire frame fractures occurred in 37/104 (36%), without any associated clinical sequelae, residual shunt, or device instability. CONCLUSION: The GCA performed effectively and safely in this initial cohort, and led to FDA approval based on this data.


Assuntos
Cateterismo Cardíaco/instrumentação , Comunicação Interatrial/terapia , Dispositivo para Oclusão Septal , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Cateterismo Cardíaco/efeitos adversos , Criança , Pré-Escolar , Feminino , Comunicação Interatrial/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Desenho de Prótese , Sistema de Registros , Fatores de Tempo , Resultado do Tratamento , Estados Unidos , Adulto Jovem
16.
Catheter Cardiovasc Interv ; 95(5): 932-936, 2020 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-31876383

RESUMO

OBJECTIVE: To assess the outcomes and potential predictors of residual leak after implantation of the GORE CARDIOFORM Septal Occluder (GSO) in secundum atrial septal defects (ASDs). BACKGROUND: The non-self-centering design of the GSO could lead to residual leak at the edge of the device. Outcomes of residual leak are poorly understood. METHODS: Retrospective, multicenter review of patients treated with the GSO for the pivotal and continued access study. Procedural, echocardiographic, and follow up data were reviewed. Multivariate analysis was performed to determine predictors of leak at implant and outcomes of these leaks. RESULTS: There were 370 total ASD device closures with the GSO, 65 (17.56%) of which were found to have residual leak at implantation. Patients with residual leak had larger defects (10.33 ± 3.05 mm vs. 9.13 ± 2.89 mm, p = .006) and smaller aortic rims (4.87 ± 3.33 mm vs. 6.17 ± 3.78 mm, p = .019), as compared to those without leak. Larger devices were implanted (p = .008) and more devices per case (p = .007) were utilized in the residual leak cohort as compared to those without leak. Overall, among patients with residual leak, there was a significant decrease in leak size over 1 year, from 1.55 ± 0.75 mm to 0.25 ± 0.74 mm (p < .001), with the majority (87.6%) disappearing by 12-month follow-up. CONCLUSIONS: Residual leak at implantation can be seen after ASD device closure with the GSO, more commonly in larger defects with smaller retroaortic rims. The vast majority of these leaks completely resolve by 1 year follow up.


Assuntos
Cateterismo Cardíaco/instrumentação , Comunicação Interatrial/terapia , Dispositivo para Oclusão Septal , Adolescente , Cateterismo Cardíaco/efeitos adversos , Criança , Pré-Escolar , Ensaios Clínicos como Assunto , Feminino , Comunicação Interatrial/diagnóstico por imagem , Comunicação Interatrial/fisiopatologia , Humanos , Masculino , Desenho de Prótese , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento , Estados Unidos
17.
J Invasive Cardiol ; 29(9): E105-E106, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28878104

RESUMO

A 1-month-old, 2.4 kg infant, previously born at 32 weeks gestation, was found to have a murmur while in the neonatal intensive care unit. The patient had ongoing feeding intolerance and required supplemental oxygen via nasal cannula. Cardiac computed tomography showed discrete stenosis of the proximal left pulmonary artery (LPA) with a normal-sized distal LPA. We describe the treatment course with transcatheter coronary stent implantation.


Assuntos
Artéria Pulmonar/cirurgia , Estenose de Artéria Pulmonar/cirurgia , Stents , Procedimentos Cirúrgicos Vasculares/métodos , Angiografia Coronária , Humanos , Recém-Nascido , Artéria Pulmonar/anormalidades , Estenose de Artéria Pulmonar/congênito , Estenose de Artéria Pulmonar/diagnóstico
18.
Cardiol Young ; 27(1): 199-201, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27641361

RESUMO

Pulmonary arteriovenous fistula is a rare vascular anomaly that can cause significant morbidity and mortality. The presence and significance of symptoms are dependent on the size of the right-to-left shunt. Thromboembolic events may result in cerebrovascular accidents or systemic vascular occlusions. We present a case of an adolescent without cardiorespiratory symptoms, who developed flank pain due to renal infarction, followed by a brief literature review.


Assuntos
Fístula Arteriovenosa/complicações , Rim/irrigação sanguínea , Artéria Pulmonar/anormalidades , Veias Pulmonares/anormalidades , Artéria Renal , Tromboembolia/etiologia , Adolescente , Angiografia , Fístula Arteriovenosa/diagnóstico , Humanos , Masculino , Tromboembolia/diagnóstico , Tomografia Computadorizada por Raios X
19.
J Vet Cardiol ; 14(2): 351-61, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22578699

RESUMO

Subvalvular aortic stenosis (SAS) is one of the most common congenital cardiac malformations in dogs. Unfortunately, the long term success rate and survival data following either open heart surgery or catheter based intervention has been disappointing in dogs with severe subaortic stenosis. Medical therapy is currently the only standard recommended treatment option. A cutting balloon dilation catheter has been used successfully for resistant coronary artery and peripheral pulmonary arterial stenoses in humans. This catheter is unique in that it has the ability to cut, or score, the stenotic region prior to balloon dilatation of the stenosis. The use of cutting balloon valvuloplasty combined with high pressure valvuloplasty for dogs with severe subaortic stenosis has recently been reported to be a safe and feasible alternative therapeutic option. The following report describes this technique, outlines the materials required, and provides some 'tips' for successful percutaneous subaortic balloon valvuloplasty.


Assuntos
Estenose Aórtica Subvalvar/veterinária , Cateterismo/veterinária , Doenças do Cão/cirurgia , Animais , Estenose Aórtica Subvalvar/cirurgia , Cateterismo/efeitos adversos , Cateterismo/métodos , Cães , Complicações Intraoperatórias/veterinária , Complicações Pós-Operatórias/veterinária
20.
Clin Pediatr (Phila) ; 47(9): 919-25, 2008 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-18626106

RESUMO

Because pediatric cardiologists can accurately diagnose innocent murmurs by physical exam alone, the authors developed a system for remote cardiac auscultation. They hypothesized that their system could accurately classify auscultatory findings as normal/innocent or pathologic. Patients undergoing evaluation underwent examination, echocardiography, and heart sound recording. Pediatric cardiologists evaluated the heart sounds and classified the case as either normal/innocent or pathologic. They reviewed103 heart sound data sets; 85% of the cases were accurately classified as either normal/innocent or pathologic, with a sensitivity of 82% and specificity of 86%. However, when accounting for clinical diagnosis, reviewer uncertainty, and ECG abnormalities, the sensitivity and specificity improved to 91% and 88% (accuracy 89%), respectively. Degree of certainty with the telecardiology diagnosis correlated with correct interpretation (P < .005). Digital heart sound recordings evaluated via telemedicine can distinguish normal/innocent murmurs from pathologic ones. Such a system could improve the use of pediatric cardiology services.


Assuntos
Cardiopatias/diagnóstico , Sopros Cardíacos/diagnóstico , Ruídos Cardíacos , Telemedicina , Adolescente , Adulto , Criança , Pré-Escolar , Diagnóstico Diferencial , Feminino , Auscultação Cardíaca , Humanos , Lactente , Masculino , Sensibilidade e Especificidade , Interface Usuário-Computador
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA