Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 84
Filtrar
1.
Abdom Radiol (NY) ; 49(6): 2083-2097, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38441632

RESUMO

Patients with Crohn's disease (CD) are at increased risk of developing small bowel cancer, since chronic inflammation may trigger the histopathological sequence that begins from low-grade dysplasia of the intestinal epithelium and may eventually lead to malignant transformation. Owing to their location in a portion of the gastrointestinal tract which is not easily accessible to conventional endoscopic techniques, the detection of CD-related small bowel cancers is still a clinical challenge. The radiological features of CD-related small bowel adenocarcinoma (SBA) in patients with CD have been described in some previous studies, including its appearance in both CT and MRI examinations. Radiological signs of active or fibrostenotic CD may be intermixed with those suggesting the presence of CD-related SBA. In CT studies, the most relevant findings consistent with malignant transformation are the presence of a stricture with irregular asymmetric thickening of small bowel walls, loss of mural stratification, and moderate enhancement after intravenous administration of iodinated contrast media, in association with enlarged adjacent mesenteric lymph nodes. Many of the CD-related SBA features that can be observed on CT imaging are similar to those detectable by MRI. This latter modality provides the additional value of the functional characterization of small bowel strictures, thereby helping to distinguish between inflammatory, fibrotic, and malignant stenosis in the setting of active CD. Positron Emission Tomography (PET)/CT enables the metabolic assessment of enlarged mesenteric lymph nodes, and PET/MRI fusion imaging can incorporate morphological, functional and metabolic information into a single set of imaging data, thus overcoming the limitations of the separate assessment of each individual modality. Owing to the low incidence and prevalence of this long-term complication of CD, we believe that a detailed multimodality pictorial essay on this topic, also including the PET-CT and fusion imaging documentation of some cases, would be useful to the medical literature.


Assuntos
Doença de Crohn , Neoplasias Intestinais , Intestino Delgado , Imagem Multimodal , Humanos , Doença de Crohn/diagnóstico por imagem , Doença de Crohn/complicações , Imagem Multimodal/métodos , Intestino Delgado/diagnóstico por imagem , Neoplasias Intestinais/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Adenocarcinoma/diagnóstico por imagem
2.
Clin Exp Rheumatol ; 40(1): 78-85, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-33822711

RESUMO

OBJECTIVES: We aimed to evaluate joint and vessel uptake in patients with polymyalgia rheumatica (PMR) by FDG-PET and correlate it with clinical findings. METHODS: Consecutive PMR patients, without clinical signs of giant cell arteritis, underwent a standardised clinical examination and FDG-PET/CT. Controls were consecutive subjects undergoing FDG-PET for the suspicion of neoplasm not confirmed by the examination. Uptake was evaluated by a qualitative visual score, using the liver uptake as reference and by the semi-quantitative mean standardised uptake value (SUV) and target-to-background ratio (TBR) methods. RESULTS: Eighty-four patients and 84 controls (55 women, median age 73 years, range 50-92 years in both groups) were studied. Sixteen patients were taking glucocorticoids (GC). PMR patients showed a higher articular uptake than controls. GC-treated patients showed uptake lower than GC-naïve patients, but still higher than controls. PMR patients showed a higher vascular uptake than controls in all districts except in the carotid arteries, when evaluated by the visual score. Conversely, the semi-quantitative approach yielded no significant differences. Forty-two patients (50%) showed PET evidence of large-vessel vasculitis (LVV), defined as uptake ≥ than that of the liver, and 11.9% showed LVV with vascular uptake higher than that of the liver. The correlation between clinical findings and uptake was scarce. Neither clinical nor laboratory findings could predict the presence of LVV. CONCLUSIONS: Patients with PMR show a typical joint pattern at FDG-PET. There are no clinical or laboratory predictors of LVV. Imaging appears to be the only tool to assess LVV in these patients.


Assuntos
Arterite de Células Gigantes , Polimialgia Reumática , Idoso , Idoso de 80 Anos ou mais , Feminino , Fluordesoxiglucose F18 , Arterite de Células Gigantes/diagnóstico por imagem , Humanos , Pessoa de Meia-Idade , Polimialgia Reumática/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tomografia por Emissão de Pósitrons , Compostos Radiofarmacêuticos
3.
Medicina (Kaunas) ; 57(6)2021 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-34206116

RESUMO

Background and Objectives: 18F-fluorodeoxyglucose (FDG) positron emission tomography/X-ray computed tomography (PET/CT) represents the mainstay diagnostic procedure for suspected ovarian cancer (OC) recurrence. PET/CT can be integrated with contrast medium and in various diagnostic settings; however, the effective benefit of this procedure is still debated. We aimed to compare the diagnostic capabilities of low-dose and contrast-enhanced PET/CT (PET/ldCT and PET/ceCT) in patients with suspected ovarian cancer relapse. Materials and Methods: 122 OC patients underwent both PET/ldCT and PET/ceCT. Two groups of nuclear medicine physicians and radiologists scored the findings as positive or negative. Clinical/radiological follow-up was used as ground truth. Sensitivity, specificity, negative/positive predictive value, and accuracy were calculated at the patient and the lesion level. Results: A total of 455 and 474 lesions were identified at PET/ldCT and PET/ceCT, respectively. At the lesion level, sensitivity, specificity, positive predictive value, negative predictive value, and accuracy were not significantly different between PET/ldCT and PET/ceCT (98%, 93.3%, 97.4%, 94.9%, and 96.9% for PET/ldCT; 99%, 95.5%, 98.3%, 97%, and 98% for PET/ceCT, p = ns). At the patient level, no significant differences in these parameters were identified (e.g., p = 0.22 and p = 0.35 for accuracy, in the peritoneum and lymph nodes, respectively). Smaller peritoneal/lymph node lesions close to physiological FDG uptake sources were found in the cases of misidentification by PET/ldCT. PET/ceCT prompted a change in clinical management in four cases (3.2%) compared to PET/ldCT. Conclusions: PET/ceCT does not perform better than PET/ldCT but can occasionally clarify doubtful peritoneal findings on PET/ldCT. To avoid unnecessary dose to the patient, PET/ceCT should be excluded in selected cases.


Assuntos
Carcinoma , Fluordesoxiglucose F18 , Humanos , Recidiva Local de Neoplasia/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tomografia por Emissão de Pósitrons , Compostos Radiofarmacêuticos , Estudos Retrospectivos , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X
4.
Clin Case Rep ; 9(1): 31-33, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33505683

RESUMO

Nodular fasciitis has to be considered as an option in the presence of a solitary, rapidly growing mass even in older adults. When possible, direct surgery should be preferred to FNAC, particularly in the older adults because of high misdiagnostic risk.

5.
J Craniofac Surg ; 32(5): e498-e500, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33481474

RESUMO

ABSTRACT: Since 1980s, the use of dermal regeneration templates (DRT) for reconstructive purposes has been described in Literature.1 The authors present their experience of 13 patients treated with integra dermal regeneration template and a single-stage surgery for different indications like oncologic reconstruction, trauma injuries, and preprosthetic surgery in the maxillo-facial district.The authors retrospectively reviewed a total of 13 patients treated with DRT at Maxillo-Facial Department of S. Maria Hospital in Terni.Inclusion criteria included the presence of a defect nonapproachable primarily or by secondary intention with an easy locoregional flap reconstruction, a complete clinical record, and a minimum 6 months follow-up.A total of 12 patients underwent surgical reconstruction with DRT at the S. Maria Hospital from June 2018 to February 2020.During follow-up, all patients in which intraoral reconstruction was performed showed first signs of re-mucosization and neovascularization after 10 days.Only in 1 patient (8%) a seroma underneath the silicon sheet was observed. Afterward, the patient healed correctly with no other complications.Dermal regeneration template represents an option that should be considered in the head and neck district reconstruction, especially for intraoral defects where, thanks to its long-term functional results and limited alternatives, should represent a relevant choice.


Assuntos
Procedimentos de Cirurgia Plástica , Transplante de Pele , Sulfatos de Condroitina , Colágeno , Humanos , Regeneração , Estudos Retrospectivos
7.
Eur Radiol Exp ; 4(1): 55, 2020 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-33000373

RESUMO

We investigated whether the internal gantry components of our computed tomography (CT) scanner contain severe acute respiratory syndrome 2 (SARS-CoV-2) ribonucleic acid (RNA), bacterial or fungal agents. From 1 to 27 March 2020, we performed 180 examinations of patients with confirmed SARS-CoV-2 infection using a dedicated CT scanner. On 27 March 2020, this CT gantry was opened and sampled in each of the following components: (a) gantry case; (b) inward airflow filter; (c) gantry motor; (d) x-ray tube; (e) outflow fan; (f) fan grid; (g) detectors; and (h) x-ray tube filter. To detect SARS-CoV-2 RNA, samples were analysed using reverse transcriptase-polymerase chain reaction (RT-PCR). To detect bacterial or fungal agents, samples have been collected using "replicate organism detection and counting" contact plates of 24 cm2, containing tryptic soy agar, and subsequently cultured. RT-PCR detected SARS-CoV-2 RNA in the inward airflow filter sample. RT-PCR of remaining gantry samples did not reveal the presence of SARS-CoV-2 RNA. Neither bacterial nor fungal agents grew in the agar-based growth medium after the incubation period. Our data showed that SARS-Cov-2 RNA can be found inside the CT gantry only in the inward airflow filter. All remaining CT gantry components were devoid of SARS-CoV-2 RNA.


Assuntos
Betacoronavirus/isolamento & purificação , Infecções por Coronavirus/virologia , Contaminação de Equipamentos , Pneumonia Viral/virologia , Tomógrafos Computadorizados/virologia , Tomografia Computadorizada por Raios X/instrumentação , COVID-19 , Humanos , Pandemias , RNA Viral/isolamento & purificação , Reação em Cadeia da Polimerase em Tempo Real , SARS-CoV-2
8.
Q J Nucl Med Mol Imaging ; 64(4): 382-392, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32900177

RESUMO

Copper is an essential element that plays an important role in both cancer development and growth. Indeed, high levels of copper have been found in prostate cancer (PCa), and this finding have paved the way for the use of this element as a target for positron emission tomography (PET) imaging. Copper64 (64Cu) can be used alone, as 64CuCl2, and also as a precursor for the in-vitro radio-labelling of specific carriers for PET imaging in PCa, (e.g. associated to prostate-specific membrane antigen: PSMA). The use of 64Cu-PSMA can yield late acquisitions in which PET images are characterized by a higher target-to-background ratio. At the same time, the shorter positron range of 64Cu provides high spatial resolution, which leads to better detection of small lesions. In this context, the aim of this review was to systematically review studies evaluating the identification of PCa in humans by means of 64CuCl2 and other PET tracers radio-labelled with 64Cu.


Assuntos
Antígenos de Superfície/metabolismo , Radioisótopos de Cobre/química , Glutamato Carboxipeptidase II/metabolismo , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Neoplasias da Próstata/radioterapia , Compostos Radiofarmacêuticos/química , Animais , Antígenos de Superfície/uso terapêutico , Biomarcadores Tumorais/metabolismo , Radioisótopos de Cobre/farmacologia , Radioisótopos de Flúor/química , Glutamato Carboxipeptidase II/uso terapêutico , Humanos , Imageamento por Ressonância Magnética , Masculino , Compostos Radiofarmacêuticos/farmacologia , Relação Estrutura-Atividade , Tomografia Computadorizada por Raios X
9.
Eur Radiol Exp ; 4(1): 39, 2020 06 26.
Artigo em Inglês | MEDLINE | ID: mdl-32592118

RESUMO

BACKGROUND: Computed tomography (CT) enables quantification of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection, helping in outcome prediction. METHODS: From 1 to 22 March 2020, patients with pneumonia symptoms, positive lung CT scan, and confirmed SARS-CoV-2 on reverse transcription-polymerase chain reaction (RT-PCR) were consecutively enrolled. Clinical data was collected. Outcome was defined as favourable or adverse (i.e., need for mechanical ventilation or death) and registered over a period of 10 days following CT. Volume of disease (VoD) on CT was calculated semi-automatically. Multiple linear regression was used to predict VoD by clinical/laboratory data. To predict outcome, important features were selected using a priori analysis and subsequently used to train 4 different models. RESULTS: A total of 106 consecutive patients were enrolled (median age 63.5 years, range 26-95 years; 41/106 women, 38.7%). Median duration of symptoms and C-reactive protein (CRP) was 5 days (range 1-30) and 4.94 mg/L (range 0.1-28.3), respectively. Median VoD was 249.5 cm3 (range 9.9-1505) and was predicted by lymphocyte percentage (p = 0.008) and CRP (p < 0.001). Important variables for outcome prediction included CRP (area under the curve [AUC] 0.77), VoD (AUC 0.75), age (AUC 0.72), lymphocyte percentage (AUC 0.70), coronary calcification (AUC 0.68), and presence of comorbidities (AUC 0.66). Support vector machine had the best performance in outcome prediction, yielding an AUC of 0.92. CONCLUSIONS: Measuring the VoD using a simple CT post-processing tool estimates SARS-CoV-2 burden. CT and clinical data together enable accurate prediction of short-term clinical outcome.


Assuntos
Betacoronavirus , Infecções por Coronavirus/diagnóstico , Pulmão/diagnóstico por imagem , Pneumonia Viral/diagnóstico , Reação em Cadeia da Polimerase em Tempo Real/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , COVID-19 , Infecções por Coronavirus/diagnóstico por imagem , Estudos de Avaliação como Assunto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pandemias , Avaliação de Resultados da Assistência ao Paciente , Pneumonia Viral/diagnóstico por imagem , Valor Preditivo dos Testes , Prognóstico , Reprodutibilidade dos Testes , SARS-CoV-2
10.
Abdom Radiol (NY) ; 45(11): 3896-3906, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32451674

RESUMO

PURPOSE: To assess the diagnostic value of retrospectively fused PET/MRI by comparing the detection rates (DRs) of fused 64CuCl2 PET/MRI vs. fused 18F-Choline PET/MRI in patients with suspected prostatic cancer (PCa) recurrence. The secondary objective was to compare the DRs of fused PET/MRI vs. those of the separate imaging modalities. METHODS: We retrospectively evaluated 50 PCa patients with biochemical relapse after radical prostatectomy (RP) or radiotherapy (RT). All patients underwent 64CuCl2 PET/CT, 18F-Choline PET/CT, and multiparametric magnetic resonance imaging (mpMRI) within 15 days. Fused 64CuCl2-PET/MRI and fused 18F-Choline PET/MRI images were obtained by retrospective co-registration of MRI and PET images. Experienced readers interpreted the images, and the DRs of each imaging modality were assessed. RESULTS: In the patient-based analysis, overall DRs of fused 64CuCl2 PET/MRI, fused 18F-Choline PET/MRI, 64CuCl2 PET/CT, 18F-Choline PET/CT, and mpMRI were 88%, 68%, 82%, 56%, and 74%, respectively. In the lesion-based analysis, overall DRs of fused 64CuCl2 PET/MRI, fused 18F-Choline PET/MRI, 64CuCl2 PET/CT, 18 F-Choline PET/CT, and mpMRI were 95%, 66%, 87%, 58%, and 71%, respectively. CONCLUSIONS: Retrospectively fused PET/MRI is able to overcome the limitations of the separate interpretation of the individual imaging modalities. Fused 64CuCl2 PET/MRI provided the highest diagnostic performance in the detection of PCa local relapse.


Assuntos
Imageamento por Ressonância Magnética Multiparamétrica , Neoplasias da Próstata , Colina , Cobre , Humanos , Imageamento por Ressonância Magnética , Masculino , Recidiva Local de Neoplasia/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tomografia por Emissão de Pósitrons , Neoplasias da Próstata/diagnóstico por imagem , Estudos Retrospectivos
11.
Urology ; 141: e43-e44, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32305544

RESUMO

Even though most tumors located in the prostate derive from prostatic glands, there is a long list of malignant and nonmalignant causes for prostatic growths that clinicians should be aware of. Tumors of the prostate can be grouped in epithelial, neuroendocrine, stromal, mesenchymal, hematolymphoid, and miscellaneous. Solitary fibrous tumor of the prostate (SFT), is an extremely rare mesenchymal tumor (only about 20 cases reported in the literature). Histologic features resemble those of the more common variant pleural SFT. Of all, 10%-20% of SFTs, also known as malignant SFTs, behave aggressively. Herein, we describe a case of prostatic SFT in a 66-year-old patient that presented with obstructive urinary symptoms and normal prostate-specific antigen levels.


Assuntos
Neoplasias da Próstata/diagnóstico , Tumores Fibrosos Solitários/diagnóstico , Idoso , Humanos , Masculino
12.
Artigo em Inglês | MEDLINE | ID: mdl-32093315

RESUMO

BACKGROUND: Knowledge of the Adult Baby-Diaper Lovers (ABDL) phenomena is quite recent and there are, of yet, few studies on this phenomenon. AIM: This study was conceived to investigate the functions of ABDL behaviours and the characteristics of ABDL in an online Italian community sample. We hypothesized that ABDL phenomena were associated with general psychological maladjustment and with an experience of parental rejection during childhood. It was also assumed that there would be differences in ABDL profiles based on the age of appearance of their first Adult Baby-Diaper Lover (ABDL) fantasies. METHOD: An internet-based study was conducted and it involved 38 adults aged between 18 and 74 years (M = 34.95; SD = 12.25). Participants were first given an ad hoc questionnaire, which was devised to obtain information about the anamnestic variables related to ABDL. Then, the participants filled out the Cognitive Behaviour Assessment 2.0 battery to obtain anamnestic information regarding their psychological, medical, and personal history and to evaluate primary psychological dimensions in clinical practice. Finally, they filled out the Adult Parental Acceptance-Rejection Questionnaire, to evaluate their recollections of parental perceived rejection, and the Personality Assessment Questionnaire, to evaluate the primary psychological aspects related to parental rejection. RESULTS: The data indicated that adults with ABDL showed the presence of anxious traits and recollections of parental rejection during childhood. Moreover, associations were observed between current or previous ABDL phenomena enuresis and negative mood states. CONCLUSION: Specific kinds of parental modes, anxiety traits, and enuresis seem to be the source of ABDL interests. Moreover, ADBL behaviours seem to assume different functions and meanings.


Assuntos
Fraldas Infantis , Fetichismo Psiquiátrico , Adolescente , Adulto , Idoso , Ansiedade , Enurese , Humanos , Itália , Pessoa de Meia-Idade , Poder Familiar , Rejeição em Psicologia , Inquéritos e Questionários , Adulto Jovem
13.
Abdom Radiol (NY) ; 44(12): 4011-4021, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31696266

RESUMO

PURPOSE: To assess the agreement of one-dimensional transient elastography (1D-TE), two-dimensional shear wave elastography (2D-SWE), and magnetic resonance elastography (MRE) in a consecutive cohort of patients affected by hepatitis C virus (HCV) and to understand which patient-related factors are associated with disagreement. METHODS: Ninety-one consecutive patients with current or previous chronic HCV infection were enrolled between March 2017 and September 2018. We assessed the correlation between stiffness measurements expressed in kilopascals (kPa). After converting kPa values in three groups of increasing fibrosis burden using validated cut-off values, we assessed the agreement among the different techniques. Factors influencing inter-modality disagreement were examined by employing multivariate logistic regression analysis. RESULTS: Seventy-seven patients met the inclusion criteria and had reliable measurements by all stiffness imaging techniques. At the quantitative analysis, a strong correlation between stiffness measurements was found (Spearman's rho values ranging from 0.7 to 0.89 in all pairs of techniques). Complete concordance among MRE, 1D-TE, and 2D-SWE was found in 64.9% of patients, and the agreement was highest between MRE and 1D-TE, with κ value of 0.801. In only 2/77 patients (2.6%), there was complete disagreement. High body mass index (BMI) was the only factor significantly associated with inter-modality discordance. CONCLUSIONS: MRE, 1D-TE, and 2D-SWE assigned the majority of patients to the same fibrosis group. The agreement was at least good, and there was a strong correlation between kPa values in all three pairs of techniques. Highest agreement was found between MRE and 1D-TE. High BMI was associated with discordance among the techniques.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Hepatite C Crônica/diagnóstico por imagem , Hepatite C Crônica/virologia , Cirrose Hepática/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Biomarcadores/sangue , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Estudos Prospectivos
15.
EJNMMI Res ; 8(1): 18, 2018 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-29492782

RESUMO

BACKGROUND: The aim of the present study is to evaluate the kinetics and dosimetry of 64CuCl2 in human prostate cancer (PCa) lesions. We prospectively evaluated 50 PCa patients with biochemical relapse after surgery or external beam radiation therapy. All patients underwent 64CuCl2-PET/CT to detect PCa recurrence/metastases. Volumes of interest were manually drawn for each 64CuCl2 avid PCa lesion with a diameter > 1 cm on mpMRI in each patient. Time-activity curves for all lesions were obtained. The effective and biological half-life and the standard uptake values (SUVs) were calculated. Tumour/background ratio (TBR) curves as a function of time were considered. Finally, the absorbed dose per lesion was estimated. RESULTS: The mean effective half-life of 64CuCl2 calculated in the lymph nodes (10.2 ± 1.7 h) was significantly higher than in local relapses (8.8 ± 1.1 h) and similar to that seen in bone metastases (9.0 ± 0.4 h). The mean 64CuCl2 SUVmax calculated 1 h after tracer injection was significantly higher in the lymph nodes (6.8 ± 4.3) and bone metastases (6.8 ± 2.9) than in local relapses (4.7 ± 2.4). TBR mean curve of 64CuCl2 revealed that the calculated TBRmax value was 5.0, 7.0, and 6.2 in local relapse and lymph node and bone metastases, respectively, and it was achieved about 1 h after 64CuCl2 injection. The mean absorbed dose of the PCa lesions per administrated activity was 6.00E-2 ± 4.74E-2mGy/MBq. Indeed, for an administered activity of 3.7 GBq, the mean dose absorbed by the lesion would be 0.22 Gy. CONCLUSIONS: Dosimetry showed that the dose absorbed by PCa recurrences/metastases per administrated activity was low. The dosimetric study performed does not take into account the possible therapeutic effect of the Auger electrons. Clinical trials are needed to evaluate 64Cu internalization in the cell nucleus that seems related to the therapeutic effectiveness reported in preclinical studies.

16.
J Nucl Med ; 59(3): 444-451, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-28887398

RESUMO

Our objective was to evaluate the biodistribution, kinetics, and radiation dosimetry of 64CuCl2 in humans and to assess the ability of 64CuCl2 PET/CT to detect prostate cancer (PCa) recurrence in patients with biochemical relapse. Methods: We prospectively evaluated 50 PCa patients with biochemical relapse after surgery or external-beam radiation therapy. All patients underwent 64CuCl2 PET/CT, 18F-choline PET/CT, and multiparametric MRI within 15 d of each other. Experienced readers interpreted the images, and the detection rate (DR) of each imaging modality was calculated. Histopathology, when available; clinical or laboratory response; and multidisciplinary follow-up were used to confirm the site of disease. In parallel, biodistribution, kinetics of the lesions, and radiation dosimetry of 64CuCl2 were evaluated. Results: From a dosimetric point of view, an administered dose of 200 MBq for 64CuCl2 translated into a 5.7-mSv effective dose. Unlike 18F-choline, 64CuCl2 was not excreted or accumulated in the urinary tract, thus allowing thorough pelvic exploration. The maximum 64CuCl2 uptake at the sites of PCa relapse was observed 1 h after tracer injection. In our cohort, 64CuCl2 PET/CT proved positive in 41 of 50 patients, with an overall DR of 82%. The DRs of 18F-choline PET/CT and multiparametric MRI were 56% and 74%, respectively. The difference between the DRs of 64CuCl2 PET/CT and 18F-choline PET/CT was statistically significant (P < 0.001). Interestingly, on considering prostate-specific antigen (PSA) value, 64CuCl2 PET/CT had a higher DR than 18F-choline PET/CT in patients with a PSA of less than 1 ng/mL. Conclusion: The biodistribution of 64CuCl2 is more suitable than that of 18F-choline for exploring the pelvis and prostatic bed. The 64CuCl2 effective dose is like those of other established PET tracers. In patients with biochemical relapse and a low PSA level, 64CuCl2 PET/CT shows a significantly higher DR than 18F-choline PET/CT.


Assuntos
Radioisótopos de Cobre , Cobre/química , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Neoplasias da Próstata/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva
17.
Acta Radiol ; 58(7): 800-808, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27784760

RESUMO

Background Breast magnetic resonance imaging (MRI) is more accurate than ultrasound and mammography in estimating local extension of both invasive breast cancer and ductal carcinoma in situ (DCIS) and it is part of a breast cancer patient's preoperative management. Purpose To verify if time interval between breast biopsy and preoperative MRI, lesion margins, and biopsy technique can influence tumor sizing on MRI. Material and Methods By a database search, we retrospectively identified all women with a newly diagnosed, biopsy-proven, primary breast cancer who underwent MRI before surgery. The time interval between biopsy and MRI, the type of biopsy procedure, and various pathological features of tumors were collected. We defined the concordance between MRI and pathology measurements as a difference of <5 mm in lesion sizing. Results One hundred and sixty-six women (mean age, 51.4 ± 10.4 years) were included. The time interval between biopsy and MRI showed only a weak correlation with the absolute MRI-pathology difference (r = 0.236). Stratifying the whole cohort of patients using a cutoff value of 30 days, we found that the MRI-pathology discordance was significantly higher in patients with a biopsy-MRI time interval >30 days ( P < 0.05). By means of multivariate analysis, we found that DCIS subtype and the presence of poorly defined margins on MRI are the only two factors independently and strongly associated with MRI-pathology discordance in lesion sizing. Conclusion Size, histology, and margins of tumors may affect the accuracy of MRI measurements. The type of biopsy procedure and the time interval between biopsy and preoperative MRI are not independently associated to MRI-pathology discordance.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Imageamento por Ressonância Magnética , Adulto , Idoso , Biópsia , Feminino , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Tempo , Carga Tumoral
18.
Arch Esp Urol ; 69(9): 662-665, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27845699

RESUMO

OBJECTIVE: Kidney is the most commonly injured organ of the genitourinary tract after trauma. Half of blunt renal injuries are caused by traffic accidents, but sport activities are also included as frequent causes. Skatebording is popular among young people but it deserves being considered a potential cause of severe injuries. A number of published medical reports mainly refer to bone, joint and head injuries but no cases have been reported on urologic or kidney trauma. METHODS: We present two cases of renal trauma in adolescent males occurred while doing skateboarding. RESULTS: The first patient had a grade 3 renal trauma with urinary extravasation, managed conservatively with ureteral stenting. The second patient had a grade 4 to 5 renal trauma with cardiovascular instability requiring an urgent nephrectomy. CONCLUSIONS: We would emphasize these cases as an emergent urological warning. Scientific information and medical education should be addressed from physicians to a targeted population, in order to reduce among teens the incidence of injuries of such at-risk activity.


Assuntos
Rim/lesões , Patinação/lesões , Adolescente , Humanos , Masculino
19.
BMC Anesthesiol ; 16(1): 67, 2016 08 24.
Artigo em Inglês | MEDLINE | ID: mdl-27553378

RESUMO

BACKGROUND: Computed tomography (CT) reconstruction parameters, such as slice thickness and convolution kernel, significantly affect the quantification of hyperaerated parenchyma (VHYPER%). The aim of this study was to investigate the mathematical relation between VHYPER% calculated at different reconstruction settings, in mechanically ventilated and spontaneously breathing patients with different lung pathology. METHODS: In this retrospective observational study, CT scans of patients of the intensive care unit and emergency department were collected from two CT scanners and analysed with different kernel-thickness combinations (reconstructions): 1.25 mm soft kernel, 5 mm soft kernel, 5 mm sharp kernel in the first scanner; 2.5 mm slice thickness with a smooth (B41s) and a sharp (B70s) kernel on the second scanner. A quantitative analysis was performed with Maluna® to assess lung aeration compartments as percent of total lung volume. CT variables calculated with different reconstructions were compared in pairs, and their mathematical relationship was analysed by using quadratic and power functions. RESULTS: 43 subjects were included in the present analysis. Image reconstruction parameters influenced all the quantitative CT-derived variables. The most relevant changes occurred in the hyperaerated and normally aerated volume compartments. The application of a power correction formula led to a significant reduction in the bias between VHYPER% estimations (p < 0.001 in all cases). The bias in VHYPER% assessment did not differ between lung pathology nor ventilation mode groups (p > 0.15 in all cases). CONCLUSIONS: Hyperaerated percent volume at different reconstruction settings can be described by a fixed mathematical relationship, independent of lung pathology, ventilation mode, and type of CT scanner.


Assuntos
Medidas de Volume Pulmonar/métodos , Pulmão/diagnóstico por imagem , Tomografia Computadorizada por Raios X/estatística & dados numéricos , Idoso , Feminino , Humanos , Processamento de Imagem Assistida por Computador/estatística & dados numéricos , Pulmão/patologia , Masculino , Pessoa de Meia-Idade , Respiração , Respiração Artificial , Estudos Retrospectivos
20.
J Craniofac Surg ; 27(7): e636-e637, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27513781

RESUMO

The authors present a rare patient of right synovial chondromatosis (SC) of the temporomandibular joint in which diagnosis was late and delay led to SC extension to the cranial base. Synovial chondromatosis is a rare benign disorder characterized by multiple cartilaginous free-floating nodules originated from the synovial membrane of large articular joints of the body. Differential diagnosis is with neoplasm and radical surgical removal is essential. The patient came to the authors' observation complaining about long-lasting temporomandibular joint dysfunction. The patient already underwent either functional or medical therapy in times without any improvement. Clinical examination showed limited mouth opening and swelling of the right preauricolar region with no signs of facial nerve palsy and without paresthesia or hearing loss. No history of recent trauma was recorded. Magnetic resonance imaging showed a mucous-like hyperintense mass with small hypointense spots inside. A preoperative computed tomography scan was performed and showed a mass extending from the superior aspect of the temporomandibular joint to the glenoid fossa, which was partially eroded. The patient underwent either open joint surgery or arthroscopy of the superior joint space and a large number of chondrocytes were removed. No complications were recorded postoperatively and the patient completely recovered after 6 months. Histology confirmed the diagnosis of synovial condromatosys of the right temporomandibular joint.


Assuntos
Condromatose/diagnóstico , Diagnóstico Tardio , Transtornos da Articulação Temporomandibular/diagnóstico , Síndrome da Disfunção da Articulação Temporomandibular/diagnóstico , Articulação Temporomandibular/diagnóstico por imagem , Adulto , Artroscopia , Condromatose/etiologia , Diagnóstico Diferencial , Feminino , Seguimentos , Humanos , Imageamento por Ressonância Magnética , Síndrome da Disfunção da Articulação Temporomandibular/complicações , Fatores de Tempo , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA