Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
2.
Neuroradiology ; 54(1): 51-9, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21455720

RESUMO

INTRODUCTION: Vein of Galen aneurysmal malformation (VGAM) is a severe pediatric neurovascular disease. Children often present with congestive heart failure in the neonatal period. In the last decades, endovascular treatment became the first therapeutic option. The purpose of this study is to report our results in the treatment of VGAM with a combined transvenous and transarterial method in the last ten years. METHODS: In our cohort of 28 patients with VGAM, 22 patients were treated endovascularly between 1992 and 2010. In the last 10 years, a consecutive series of 14 children were treated with a combined transvenous and transarterial method. The therapeutic goal was immediate shunt reduction of the arteriovenous malformation, especially in the neonatal period. Closure of the fistulous connections was achieved by coiling using a combined transvenous and transarterial approach, called "kissing microcatheter technique". RESULTS: Eight of 14 children presented in the neonatal period with severe congestive heart failure. The other six patients presented between the age of 2 and 17 months. One patient died due to a non-procedural complication in another hospital 2 years after the last treatment. Complete or >90% of angiographically confirmed closure of the malformation was documented in 11 of 14 patients. Normal or near-normal outcome was achieved in 9 of 13 surviving children, a non-favorable outcome was observed in four children. Control of heart failure was achieved in all patients. CONCLUSION: Endovascular treatment of VGAM using a combined transvenous and transarterial method is a safe procedure with a low complication rate. The overall outcome can be improved, especially in the high-risk neonatal group with congestive heart failure.


Assuntos
Malformações Vasculares do Sistema Nervoso Central/terapia , Veias Cerebrais/anormalidades , Embolização Terapêutica/métodos , Aneurisma Intracraniano/terapia , Malformações Vasculares do Sistema Nervoso Central/diagnóstico , Malformações Vasculares do Sistema Nervoso Central/diagnóstico por imagem , Meios de Contraste/administração & dosagem , Feminino , Humanos , Lactente , Recém-Nascido , Aneurisma Intracraniano/diagnóstico , Aneurisma Intracraniano/diagnóstico por imagem , Iohexol/administração & dosagem , Iohexol/análogos & derivados , Angiografia por Ressonância Magnética , Imageamento por Ressonância Magnética , Masculino , Estudos Retrospectivos , Análise de Sobrevida , Resultado do Tratamento , Ultrassonografia Doppler Transcraniana
3.
J Med Case Rep ; 5: 424, 2011 Aug 31.
Artigo em Inglês | MEDLINE | ID: mdl-21880120

RESUMO

INTRODUCTION: Tumors of the pancreatic head can infiltrate the superior mesenteric vein. In such cases, the deep veins of the lower limbs can serve as suitable autologous conduits for superior mesenteric vein reconstruction after its resection. Few data exist, however, describing the technique and the immediate patency of such reconstruction. CASE REPORT: We present the case of a 70-year-old Caucasian man with a metachronous metastasis of colon cancer and infiltration of the uncinate pancreatic process, on the anterior surface of which the tumor was located. En bloc resection of the tumor was performed with resection of the superior mesenteric vein and reconstruction. A 10 cm segment of the superficial femoral vein was harvested for the reconstruction. The superficial femoral vein segment was inter-positioned in an end-to-end fashion. The post-operative conduit patency was documented ultrasonographically immediately post-operatively and after a six-month period. The vein donor limb presented subtle signs of post-operative venous hypertension with edema, which was managed with compression stockings and led to significant improvement after six months. CONCLUSION: In cases of exploratory laparotomies with high clinical suspicion of pancreatic involvement, the potential need for vascular reconstruction dictates the preparation for leg vein harvest in advance. The superficial femoral vein provides a suitable conduit for the reconstruction of the superior mesenteric vein. This report supports the uncomplicated nature of this technique, since few data exist about this type of reconstruction.

4.
Radiology ; 244(2): 532-40, 2007 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-17641372

RESUMO

PURPOSE: To evaluate the sensitivity of 16-detector row computed tomographic (CT) angiography in diagnosis of intracranial aneurysms and to determine whether multidetector CT angiography provides sufficient diagnostic information to guide endovascular treatment, with combined imaging and clinical data as the reference standard. MATERIALS AND METHODS: Institutional review board approval and informed consent were obtained. Eighty-seven patients clinically suspected of having subarachnoid hemorrhage underwent multidetector CT angiography and digital subtraction angiography (DSA). Aneurysm detection with multidetector CT angiography and DSA was analyzed on a per-patient and a per-aneurysm basis. For each aneurysm deemed ruptured on multidetector CT angiograms, the same multidetector CT angiography data set was used to determine whether the aneurysm was suitable for endovascular coil placement or whether a neurosurgical procedure was preferable. Criteria were based on neck width in relation to aneurysm size and the presence of vessels originating from the aneurysm. Results were compared with actual treatment that had been performed in each aneurysm after full diagnostic work-up, including DSA. Sensitivity, specificity, and positive and negative predictive values for aneurysm presence were determined. RESULTS: The reference standard revealed 84 aneurysms in 63 patients. Multidetector CT angiography was used to correctly identify 62 of 63 patients with 80 of 84 aneurysms and to correctly rule out aneurysms in 24 patients. DSA was used to correctly identify 62 of 63 patients with 79 of 84 aneurysms and to correctly rule out aneurysms in 23 patients. Per patient, the sensitivity, specificity, and positive and negative predictive values, respectively, for presence of aneurysm(s) were 98%, 100%, 100%, and 96% for multidetector CT angiography and 98%, 100%, 98%, and 96% for DSA. Per aneurysm, the possibility of coil embolization was correctly assessed with multidetector CT angiography in 69 (93%) of 74 target aneurysms for acute occlusive treatment. CONCLUSION: Multidetector CT angiography offers high diagnostic accuracy-equivalent to that of DSA-in the detection of intracranial aneurysms. Also, the possibility of coil embolization can be reliably determined with multidetector CT angiography.


Assuntos
Angiografia Cerebral/métodos , Aneurisma Intracraniano/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Adulto , Idoso , Idoso de 80 Anos ou mais , Angiografia Digital , Meios de Contraste , Embolização Terapêutica , Feminino , Humanos , Aneurisma Intracraniano/terapia , Iohexol/análogos & derivados , Masculino , Pessoa de Meia-Idade , Planejamento de Assistência ao Paciente , Estudos Prospectivos , Interpretação de Imagem Radiográfica Assistida por Computador
5.
Eur Radiol ; 16(9): 2051-66, 2006 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-16416105

RESUMO

Digital subtraction angiography (DSA) is still considered the gold standard for most applications in neurovascular imaging. However, with the ongoing development of cross-sectional imaging modalities DSA is increasingly being replaced by less invasive methods. This contribution describes the diagnostic value and the increasing potential of computed tomography angiography (CTA) and magnetic resonance angiography (MRA) in the diagnosis and follow-up of intracranial aneurysms. The main role of CTA is in the diagnosis and therapy planning of ruptured aneurysms; in contrast, MRA plays an increasingly important role in the screening for asymptomatic aneurysms (especially in cases of familial subarachnoid hemorrhage) and in the follow-up after endovascular therapy with coils and/or intracranial stents. Technical issues concerning examination technique are covered here as well as an approach to advanced postprocessing of the image data. Furthermore, a brief outlook on the impact of new developments (MRA with parallel imaging and at 3.0 T) is given.


Assuntos
Aneurisma Intracraniano/diagnóstico , Angiografia por Ressonância Magnética , Tomografia Computadorizada por Raios X , Angiografia Digital , Seguimentos , Programas de Rastreamento
6.
Radiology ; 232(3): 693-700, 2004 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-15273341

RESUMO

PURPOSE: To compare three tube voltages in digital selenium radiography for the detection of simulated interstitial lung disease, nodules, and catheters. MATERIALS AND METHODS: Simulated catheters, nodules, and ground-glass, linear, miliary, and reticular patterns were superimposed over an anthropomorphic chest phantom. Digital selenium radiography was performed with different tube voltages (70, 90, and 150 kVp). Hard-copy images were generated. Detection performance of five radiologists was compared by using receiver operating characteristic (ROC) analysis involving 54,000 observations. RESULTS: The detection of ground-glass, linear, miliary, and reticular patterns over lucent lung and of nodules equal to, smaller than, and larger than 10 mm increased when 70 kVp and/or 90 kVp was used. However, only the reticular pattern was significantly better detected at lower peak voltage (P <.05). Simulated catheters and nodules over the mediastinum showed smaller areas under the ROC curve at lower peak voltage. These results were not statistically significant (P >.05). CONCLUSION: The diagnostic performance of digital selenium radiography at lower peak voltage is at least as good as that at higher peak voltage for interstitial lung disease over lucent lung. Performance is equivalent for nodules and catheters over obscured chest regions at lower peak voltages compared with that at 150 kVp. Our results implicate that the use of high-voltage technique in digital selenium radiography should be reassessed.


Assuntos
Doenças Pulmonares Intersticiais/diagnóstico por imagem , Imagens de Fantasmas , Cateterismo , Pneumopatias/diagnóstico por imagem , Radiografia , Selênio
7.
Invest Radiol ; 39(2): 97-103, 2004 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-14734924

RESUMO

RATIONALE AND OBJECTIVES: To evaluate a large area, cesium iodide amorphous silicon flat-panel detector (CsI/a-Si) at 3 tube voltages to detect simulated interstitial lung disease, nodules, and catheters. METHODS: Simulated interstitial lung disease, nodules, and catheters were superimposed over a chest phantom. Images were generated at 125 kVp, 90 kVp, and 70 kVp at the same surface dose and reduced effective dose equivalent for 90 kVp and 70 kVp and printed on hard copies. Fifty-four thousand observations were analyzed by receiver operating characteristic (ROC). RESULTS: Detectability of linear, miliary, reticular pattern, and nodules over lucent lung as well as of catheters and nodules over obscured chest areas increased at 90 and/or 70 kVp with higher Az values; however, only it was statistically significant for reticular pattern at 70 kVp and nodules at 90 kVp compared with 125 kVp (P < 0.05). The detection of ground-glass pattern was worse at lower kVp (P > 0.05). CONCLUSION: For most simulated patterns, differences in diagnostic performance at 70 kVp/90 kVp and 125 kVp were not significant, except for reticular pattern and nodules over lucent lung.


Assuntos
Pulmão/diagnóstico por imagem , Imagens de Fantasmas , Ecrans Intensificadores para Raios X , Césio , Humanos , Iodetos , Pneumopatias/diagnóstico por imagem , Doses de Radiação , Intensificação de Imagem Radiográfica , Silício
8.
Radiology ; 225(2): 567-74, 2002 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-12409596

RESUMO

PURPOSE: To compare the accuracy of magnetic resonance (MR) imaging scores with that of 3-(iodine 123)-L-alpha-methyltyrosine ((123)I-IMT) single photon emission computed tomography (SPECT) in the noninvasive grading of untreated gliomas. MATERIALS AND METHODS: The study comprised 15 patients with low-grade gliomas (grades I-II, according to World Health Organization criteria) and 33 patients with high-grade gliomas (grades III-IV). The lesions were evaluated by using an MR imaging score based on nine criteria. The (123)I-IMT uptake was quantified as the ratio between the amino acid uptake in the tumor and that in the contralateral hemisphere. To test for potentially significant differences in diagnostic performance between contrast material-enhanced MR imaging and (123)I-IMT SPECT, binormal receiver operating characteristic curves were fitted to the data and compared by using the area test. RESULTS: The accuracy of MR imaging in the noninvasive grading of untreated gliomas was higher than that of (123)I-IMT SPECT (88% vs 79%). However, the difference in diagnostic performance was not significant on the basis of findings at receiver operating characteristic analysis (P >.2). Neither MR imaging nor (123)I-IMT SPECT allowed differentiation between high-grade gliomas (grades III and IV). CONCLUSION: Although (123)I-IMT uptake is significantly higher in high-grade gliomas than in low-grade gliomas, the performance of (123)I-IMT SPECT adds little to the accuracy of determining tumor grade when MR imaging is performed.


Assuntos
Neoplasias Encefálicas/diagnóstico , Glioma/diagnóstico , Imageamento por Ressonância Magnética , Tomografia Computadorizada de Emissão de Fóton Único , Adulto , Idoso , Idoso de 80 Anos ou mais , Astrocitoma/diagnóstico , Astrocitoma/patologia , Biópsia , Encéfalo/patologia , Neoplasias Encefálicas/classificação , Neoplasias Encefálicas/patologia , Feminino , Glioblastoma/diagnóstico , Glioblastoma/patologia , Glioma/classificação , Glioma/patologia , Humanos , Radioisótopos do Iodo/farmacocinética , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade , alfa-Metiltirosina/farmacocinética
9.
Cerebrovasc Dis ; 14(2): 139-42, 2002.
Artigo em Inglês | MEDLINE | ID: mdl-12187021

RESUMO

BACKGROUND: Primary angiitis of the central nervous system (PACNS) is a rare disease. The definite diagnosis is made upon proof of mononuclear inflammation of the vessel wall on brain biopsy. The diagnosis can also be established on clinical grounds, typical findings on intra-arterial angiography and other investigatory grounds excluding other diseases. Therapy comprises an aggressive immunosuppressive approach. Close monitoring of the patients is mandatory. Transcranial Doppler ultrasound (TCD) has not yet been used to follow up the vasculitic lesions in PACNS. CASE: We report on a 32-year-old female with massive cerebral infarctions secondary to multiple large-vessel stenoses because of probable PACNS. The patient was followed closely by means of TCD. During therapy the cerebral blood flow velocities normalized as displayed by TCD. Clinical improvement followed several days after normalization of cerebral blood flow. CONCLUSIONS: TCD is a valuable noninvasive bedside tool to monitor cerebral blood flow velocities and therapy response in patients with cerebral vasculitis, if large arteries are involved.


Assuntos
Ultrassonografia Doppler Transcraniana , Vasculite do Sistema Nervoso Central/diagnóstico por imagem , Adulto , Sistema Nervoso Central/diagnóstico por imagem , Sistema Nervoso Central/patologia , Feminino , Seguimentos , Humanos , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA