Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros








Intervalo de ano de publicação
1.
Arq. bras. oftalmol ; 74(6): 410-413, nov.-dez. 2011. tab
Artigo em Inglês | LILACS | ID: lil-613439

RESUMO

PURPOSE: To analyze the correlation between quantitative measurements outcomes and keratoconus patients' vision related quality of life (v-QoL) following intrastromal corneal ring segment implantation. METHODS: The NEI-RQL (National Eye Institute Refractive Error Quality of Life) was administered to patients requiring intrastromal corneal ring segment implantation, before and after surgery, wearing best correction for 40 days minimum. Visual acuity, refraction, corneal topography, aberrometry data (VOL-CT. software) and contrast sensitivity were recorded before and 3 months after surgery. The main outcome measures were best corrected visual acuity, refraction, steep keratometric value (Kmax), aberrometry, contrast sensitivity and v-QoL. RESULTS: There were 42 keratoconic patients (69 eyes): 19 male and 23 female, mean age 24.9 ± 5 years in this prospective study. Binocular best corrected visual acuity improved (0.13 ± 0.03 before to -0.01 ± 0.01 logMAR after surgery, p<0.001). There was a statistically significant improvement in mean spherical refraction (2.81 ± 0.44 to 1.71 ± 0.31), cylinder component (3.89 ± 0.22 to 1.82 ± 0.21), spherical equivalent (4.55 ± 0.46 to 2.40 ± 0.30), Kmax (55.92 D ± 0.62 to 52.16 D ± 0.58 D) and root mean square low order (p<0.001). Contrast sensitivity (CS) improved at all spatial frequencies: at 6 cpd improvement was higher. Root mean square higher order did not improved p=0.422. There was significant improvement across all NEI-RQL scales after surgery. Multivariate analysis showed that gender (males more satisfied than females), cylinder (1 D reduction improves 5 points in general NEI-RQL scores) and normal contrast sensitivity at 3 and 6 cpd were correlated with v-QoL. Other variables such as best corrected visual acuity, root mean square low order, root mean square higher order and Kmax did not show influence on NEI-RQL scores. CONCLUSIONS: The best patient response predictors with the NEI-RQL instrument were gender, normal CS at 3 and 6 cpd and cylinder reduction. The use of this questionnaire was crucial to assess the influence of optical tests on v-QoL in keratoconus patients who were referred for intrastromal corneal ring segment implantation.


OBJETIVO: Analisar a correlação entre fatores relacionados aos pacientes com ceratocone e suas medidas quantitativas e os resultados da qualidade de vida com o implante do anel intraestromal (ICRS). MÉTODOS: O questionário de qualidade de vida relacionado a visão (QdV-v) NEI-RQL (National Eye Institute Refractive Error Quality of Life) validado na língua portuguesa foi administrado a pacientes com indicação de implante do anel intraestromal antes e depois da cirurgia quando eles já estavam usando a correção por pelo menos 40 dias. Acuidade visual com a melhor correção, topografia de córnea, aberrometria e sensibilidade ao contraste foram medidos antes e três meses após a cirurgia. RESULTADOS: Foram incluídos neste estudo prospectivo 42 pacientes (69 olhos): 19 homens e 23 mulheres com idade média de 24,9 ± 5 anos. Houve melhora estatisticamente significante na acuidade visual com a melhor correção binocular (0,13 ± 0,03 antes para -0,01 ± 0,01 logMAR após a cirurgia, p<0,001), na refração esférica média (2,81 ± 0,44 para 1,71 ± 0,31), no componente cilíndrico (3,89 ± 0,22 para 1,82 ± 0,21), no equivalente esférico (4,55 ± 0,46 para 2,40 ± 0,30), na ceratometria máxima (55,92 D ± 0,62 para 52,16 D ± 0,58 D) e no RMS (root mean square) de baixa ordem (p<0,001). O RMS de alta ordem não teve melhora significante p=0,422. A sensibilidade ao contraste (SC) melhorou significativamente em todas as frequências especialmente na de 6 cpg. Houve melhora significante em todas as escalas do NEI-RQL após a cirurgia. A análise multivariada mostrou que sexo (homens com melhores índices de QdV-v que as mulheres), cilindro (1 D de redução aumenta em 5 pontos a escala geral do NEI-RQL) e SC normal nas frequências de 3 e 6 cpg são os fatores que interferem nos escores de QdV-v dos pacientes com implante de anel intraestromal. As outras variáveis como acuidade visual com a melhor correção, aberrometria e ceratometria máxima não influenciaram nos escores do NEI-RQL. CONCLUSÕES: Os fatores que se correlacionam a melhores pontuações na QdV-v dos pacientes com implante de anel intraestromal são: sexo, SC normal nas frequências de 3 e 6 cpg e diminuição do cilindro. A análise das medidas objetivas em conjunto com o NEI-RQL foi fundamental para identificar os fatores que influenciam nos resultados subjetivos dos pacientes com ceratocone e implante de anel intraestromal.


Assuntos
Adolescente , Adulto , Feminino , Humanos , Masculino , Adulto Jovem , Ceratocone/cirurgia , Próteses e Implantes , Qualidade de Vida , Fatores Etários , Sensibilidades de Contraste , Topografia da Córnea , Escolaridade , Estudos Prospectivos , Implantação de Prótese/métodos , Fatores Sexuais , Inquéritos e Questionários , Resultado do Tratamento , Acuidade Visual
2.
Arq Bras Oftalmol ; 74(6): 410-3, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-22331112

RESUMO

PURPOSE: To analyze the correlation between quantitative measurements outcomes and keratoconus patients' vision related quality of life (v-QoL) following intrastromal corneal ring segment implantation. METHODS: The NEI-RQL (National Eye Institute Refractive Error Quality of Life) was administered to patients requiring intrastromal corneal ring segment implantation, before and after surgery, wearing best correction for 40 days minimum. Visual acuity, refraction, corneal topography, aberrometry data (VOL-CT. software) and contrast sensitivity were recorded before and 3 months after surgery. The main outcome measures were best corrected visual acuity, refraction, steep keratometric value (Kmax), aberrometry, contrast sensitivity and v-QoL. RESULTS: There were 42 keratoconic patients (69 eyes): 19 male and 23 female, mean age 24.9 ± 5 years in this prospective study. Binocular best corrected visual acuity improved (0.13 ± 0.03 before to -0.01 ± 0.01 logMAR after surgery, p<0.001). There was a statistically significant improvement in mean spherical refraction (2.81 ± 0.44 to 1.71 ± 0.31), cylinder component (3.89 ± 0.22 to 1.82 ± 0.21), spherical equivalent (4.55 ± 0.46 to 2.40 ± 0.30), Kmax (55.92 D ± 0.62 to 52.16 D ± 0.58 D) and root mean square low order (p<0.001). Contrast sensitivity (CS) improved at all spatial frequencies: at 6 cpd improvement was higher. Root mean square higher order did not improved p=0.422. There was significant improvement across all NEI-RQL scales after surgery. Multivariate analysis showed that gender (males more satisfied than females), cylinder (1 D reduction improves 5 points in general NEI-RQL scores) and normal contrast sensitivity at 3 and 6 cpd were correlated with v-QoL. Other variables such as best corrected visual acuity, root mean square low order, root mean square higher order and Kmax did not show influence on NEI-RQL scores. CONCLUSIONS: The best patient response predictors with the NEI-RQL instrument were gender, normal CS at 3 and 6 cpd and cylinder reduction. The use of this questionnaire was crucial to assess the influence of optical tests on v-QoL in keratoconus patients who were referred for intrastromal corneal ring segment implantation.


Assuntos
Ceratocone/cirurgia , Próteses e Implantes , Qualidade de Vida , Adolescente , Adulto , Fatores Etários , Sensibilidades de Contraste , Topografia da Córnea , Escolaridade , Feminino , Humanos , Masculino , Estudos Prospectivos , Implantação de Prótese/métodos , Fatores Sexuais , Inquéritos e Questionários , Resultado do Tratamento , Acuidade Visual , Adulto Jovem
3.
Arq. bras. oftalmol ; 64(3): 185-187, maio-jun. 2001. tab
Artigo em Português | LILACS | ID: lil-289237

RESUMO

Objetivo: Comparar a paquimetria corneana encontrada (PEn) com a esperada (PEs) 3 meses após a cirurgia de LASIK para correçäo de miopia. Métodos: 77 olhos de 39 pacientes míopes foram incluídos neste estudo. A cirurgia foi realizada utilizando-se o excimer laser Technolas 217 e o microcerátomo automático da Chiron. Paquimetria foi realizada em todos os olhos antes e 3 meses após o LASIK. PEs foi obtida subtraindo-se a profundidade de ablaçäo realizada pelo laser, da paquimetria pré-operatória. Os pacientes foram divididos em 3 grupos: grupo A (55 olhos) com miopia variando de -1,00D a -5,75D; grupo B (14 olhos), de -6,00D a -10,00D e grupo C (8 olhos) acima de -10,00D. Resultados: Houve uma diminuiçäo da média do equivalente esférico de -2,71D para 0,00 no grupo A, -8,18D para 0,00 no grupo B e de -11,4D para -1,06D no grupo C. As médias das PEs foram 468 mm, 370 mm e 382 mm para os grupos A,B e C, respectivamente. As médias das PEn foram de 491 mm, 431 mm e 427 mm nos grupos A, B e C, respectivamente. Em 70 olhos (90,9 por cento) a PEn foi superior a PEs, sendo esta diferença estatisticamente significativa (p=0,001). Conclusäo: Apesar dos resultados mostrarem que a córnea encontrava-se mais espessa do que o esperado após a cirurgia de LASIK, näo foi observada hipocorreçäo significativa. Após 3 meses a refraçäo da maioria dos pacientes estava próxima da emetropia.


Assuntos
Humanos , Masculino , Feminino , Adulto , Ceratomileuse Assistida por Excimer Laser In Situ , Miopia/cirurgia , Estudos Prospectivos , Refração Ocular , Topografia da Córnea/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA