Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 131
Filtrar
1.
Front Cardiovasc Med ; 11: 1429222, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39221421

RESUMO

Background: This study aimed to investigate the influence of early diagnosis (ED) on surgical outcomes in patients definitively diagnosed with Loeys-Dietz syndrome (LDS). Methods: A retrospective review was conducted on 38 patients with LDS who underwent aortic surgery at our institution between January 1995 and June 2022. The primary endpoint was freedom from aortic reoperation. Results: Among the patients, the median age at the initial surgery was 33 (range: 39-44) years, and 23 (60.5%) patients were male. Twenty-one (55.3%; aortic dissection or rupture (n = 2) and aneurysm (n = 19)) patients were diagnosed with LDS before the initial surgery (ED group). Meanwhile, the remaining 17 (44.7%; aortic dissection or rupture (n = 13) and aneurysm (n = 4)) patients were after surgery [delayed diagnosis (DD) group]. The ED group had significantly lower rates of emergency surgery and concomitant arch procedure (P < .001, respectively) but a higher rate of valve-sparing root surgery (P = .018) compared to the DD group. No in-hospital mortality was observed in either group. Nevertheless, the ED group had a shorter postoperative hospital stay (median difference: 3 days, P = .032) and a lower rate of aortic reoperation (P = .013). Conclusion: Early detection of LDS may help in preventing acute aortic syndrome, reducing the risk of aortic reoperation, and potentially shortening hospital stay. Careful medical management before surgery could contribute to better clinical outcomes and an improved quality of life for patients with LDS.

2.
Sci Rep ; 14(1): 8087, 2024 04 06.
Artigo em Inglês | MEDLINE | ID: mdl-38582803

RESUMO

The increasing use of sodium glucose transporter 2 inhibitors (SGLT2i) for treating cardiovascular (CV) diseases and type 2 diabetes (T2D) is accompanied by a rise in euglycemic diabetic ketoacidosis occurrences in cardiac surgery patients. Patients undergoing cardiac surgery, due to their pre-existing CV disease which often requires SGLT2i prescriptions, face an increased risk of postoperative metabolic acidosis (MA) or ketoacidosis (KA) associated with SGLT2i, compounded by fasting and surgical stress. The primary aim of this study is to quantify the incidence of SGLT2i-related postoperative MA or KA and to identify related risk factors. We analyzed data retrospectively of 823 cardiac surgery patients, including 46 treated with SGLT2i from November 2019 to October 2022. Among 46 final cohorts treated preoperatively with SGLT2i, 29 (63%) developed postoperative metabolic complications. Of these 46 patients, stratified into two categories based on postoperative laboratory findings, risk factor analysis were conducted and compared. Analysis indicated a prescription duration over one week significantly elevated the risk of complications (Unadjusted OR, 11.7; p = 0.032*; Adjusted OR, 31.58; p = 0.014*). A subgroup analysis showed that a cardiopulmonary bypass duration of 60 min or less significantly raises the risk of SGLT2i-related postoperative MA in patients with a sufficient prescription duration. We omitted the term "diabetes" in describing complications related to SGLT2i, as these issues are not exclusive to T2D patients. Awareness of SGLT2i-related postoperative MA or KA can help clinicians distinguish between non-life-threatening conditions and severe causes, thereby preventing unnecessary tests and ensuring best practice.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Doenças Cardiovasculares , Diabetes Mellitus Tipo 2 , Cetoacidose Diabética , Inibidores do Transportador 2 de Sódio-Glicose , Humanos , Inibidores do Transportador 2 de Sódio-Glicose/efeitos adversos , Diabetes Mellitus Tipo 2/complicações , Diabetes Mellitus Tipo 2/tratamento farmacológico , Diabetes Mellitus Tipo 2/induzido quimicamente , Hipoglicemiantes/farmacologia , Estudos Retrospectivos , Cetoacidose Diabética/complicações , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/induzido quimicamente , Doenças Cardiovasculares/complicações , Glucose
3.
J Korean Med Sci ; 39(15): e143, 2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38651225

RESUMO

BACKGROUND: We aimed to analyze the impact of concomitant Maze procedure on the clinical and rhythm outcomes, and echocardiographic parameters in tricuspid repair for patients with severe tricuspid regurgitation (TR) and persistent atrial fibrillation (AF). METHODS: Patients who had severe TR and persistent AF and underwent tricuspid valve (TV) repair were included in the study. Both primary TR and secondary TR were included in the current study. The study population was stratified according to Maze procedure. The primary outcome was major adverse cardiovascular and cerebrovascular event (MACCE) at 15 years post-surgery. Propensity-score matching analyses was performed to adjust baseline differences. RESULTS: Three hundred seventy-one patients who underwent tricuspid repair for severe TR and persistent AF from 1994 to 2021 were included, and 198 patients (53.4%) underwent concomitant Maze procedure. The maze group showed 10-year sinus rhythm (SR) restoration rate of 55%. In the matched cohort, the maze group showed a lower cumulative incidence of cardiac death (4.6% vs. 14.4%, P = 0.131), readmission for heart failure (8.1% vs. 22.2%, P = 0.073), and MACCE (21.1% vs. 42.1%, P = 0.029) at 15 years compared to the non-maze group. Left atrial (LA) diameter significantly decreased in the maze group at 5 years (53.3 vs. 59.6 mm, P < 0.001) after surgery compared to preoperative level, and there was a significant difference in the change of LA diameter over time between the two groups (P = 0.013). CONCLUSION: The Maze procedure during TV repair in patients with severe TR and persistent AF showed acceptable SR rates and lower MACCE rates compared to those without the procedure, while also promoting LA reverse remodeling.


Assuntos
Fibrilação Atrial , Ecocardiografia , Insuficiência da Valva Tricúspide , Valva Tricúspide , Humanos , Insuficiência da Valva Tricúspide/cirurgia , Masculino , Feminino , Pessoa de Meia-Idade , Fibrilação Atrial/cirurgia , Idoso , Valva Tricúspide/cirurgia , Resultado do Tratamento , Estudos Retrospectivos , Procedimento do Labirinto , Pontuação de Propensão
4.
Artigo em Inglês | MEDLINE | ID: mdl-37890658

RESUMO

BACKGROUND: Cardiovascular involvement in pediatric patients with connective tissue disease (CTD) is life-threatening, with aortic root dilatation being the most prevalent cardiovascular abnormality. We attempted to determine long-term outcomes of valve-sparing root replacement (VSRR) in this group, including cardiovascular reoperations for aortic aneurysm and dissection. METHODS: We conducted a retrospective analysis of pediatric patients with CTD who received VSRR in a single center from 2002 to 2021. The primary end point was a composite event of all-cause death and cardiovascular reoperations. The median follow-up duration was 8.3 years, with a maximum of 20.7 years. RESULTS: The median age of 24 pediatric patients who had VSRR was 14.4 years. Marfan syndrome and Loeys-Dietz syndrome affected 19 (79.2%) and 5 (20.8%) patients, respectively. There was no early death. The 15-year survival rate was 91.7%. At 10 years after VSRR, the cumulative incidence of reoperation for aortic regurgitation was 15.6%, and for aortic aneurysm or dissection, it was 29.1%. The 10-year rate of freedom from the primary end point was 53.1%. The Cox multivariable analysis revealed younger age at surgery (hazard ratio, 1.279; 95% confidence interval, 1.086-1.505; P = .003) and VSRR before 13 years of age (hazard ratio, 5.005; 95% confidence interval, 1.146-21.850; P = .032) as independent prognostic factors for the primary endpoint. CONCLUSIONS: VSRR for aortic root dilatation in pediatric patients with CTD demonstrated good long-term survival and low reoperation rates for aortic regurgitation. However, several patients developed later aortic aneurysm or dissection, and careful surveillance may be required, particularly in those who received VSRR at younger age.

5.
J Thorac Cardiovasc Surg ; 166(2): 478-488.e5, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34872766

RESUMO

OBJECTIVE: Patients with severe tricuspid regurgitation and persistent atrial fibrillation may not be good candidates for maze procedure due to preoperative atrial remodeling and various comorbidities. We attempted to evaluate the rhythm and clinical outcomes of maze procedure in these patients. METHODS: Patients with severe tricuspid regurgitation and persistent atrial fibrillation who underwent tricuspid valve surgery between January 1994 and December 2017 at a single tertiary center were analyzed. The primary end point was sinus rhythm restoration. The key secondary end point was major adverse cardiovascular and cerebrovascular event rate, which is the composite event of stroke, cardiac death, major bleeding, and readmission for heart failure. Propensity score matching analysis was used. RESULTS: A total of 388 patients underwent tricuspid valve surgery, and among them 172 patients (44%) underwent concomitant maze procedure. The maze group had sinus rhythm restoration rate of 56% in 9 years. Further, in the matched cohort, the maze group had higher freedom from major adverse cardiovascular and cerebrovascular event rate at 10 years than the nonmaze group (55.6% vs 36.2%; P = .047). Preoperative left atrial diameter (hazard ratio, 1.022; 95% CI, 1.012-1.033; P < .001) and right atrial diameter (hazard ratio, 1.012; 95% CI, 1.003-1.022; P = .013) were independent risk factors for failure of sinus rhythm. CONCLUSIONS: Maze procedure in severe tricuspid regurgitation and persistent atrial fibrillation had acceptable rates of sinus rhythm restoration and reduced major adverse cardiovascular and cerebrovascular events in the long-term. Careful patient selection considering preoperative atrial diameters is needed to enhance maze success rate and long-term clinical outcomes.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Insuficiência da Valva Tricúspide , Humanos , Fibrilação Atrial/complicações , Fibrilação Atrial/cirurgia , Insuficiência da Valva Tricúspide/complicações , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/cirurgia , Procedimento do Labirinto/efeitos adversos , Resultado do Tratamento , Átrios do Coração , Ablação por Cateter/efeitos adversos
6.
Ann Thorac Surg ; 114(6): 2244-2252, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-34953787

RESUMO

BACKGROUND: Cryoablation is effective for not only ablating the myocardium, but also maintaining the structure of the ablated tissue. However, data comparing nitrous oxide (N2O)-based and argon gas-based cryoprobes are limited. METHODS: This study was a follow-up study of a single-center, prospective, randomized controlled trial in which 60 patients were randomly allocated to either the N2O group or the argon group. The primary endpoint of this study was sinus rhythm maintenance, and the key secondary endpoint was a composite of major adverse cardiovascular and cerebrovascular events (MACCEs) (ie, cardiac death, stroke, major bleeding, and readmission for heart failure). RESULTS: The baseline and operative characteristics of the patients in the N2O and argon groups were comparable. At the 5-year follow-up, the rate of sinus rhythm maintenance was 81.8% in the N2O group, whereas it was 78.5% in the argon group (P > .999). No significant differences in the rate of freedom from MACCEs (80.6% in the N2O group vs 81.9% in the argon group; P = .978) were observed at the 5-year follow-up. The left atrial volume index decreased over time from 114.65 mL/m2 to 65.74 mL/m2 (P < .0001) and reached similar values in the 2 groups (P = .279) at the 5-year follow-up. CONCLUSIONS: Both N2O- and argon gas-based cryoprobes showed similar rates of sinus rhythm maintenance and freedom from MACCEs at the 5-year follow-up. Both cryoprobes might have similar efficacy and safety in the arrested heart in the long term.


Assuntos
Fibrilação Atrial , Procedimentos Cirúrgicos Cardíacos , Criocirurgia , Humanos , Criocirurgia/métodos , Procedimento do Labirinto , Argônio , Óxido Nitroso , Seguimentos , Estudos Prospectivos , Fibrilação Atrial/complicações , Procedimentos Cirúrgicos Cardíacos/métodos , Resultado do Tratamento
7.
J Thorac Dis ; 13(6): 3359-3368, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34277032

RESUMO

BACKGROUND: This study aimed to investigate the early and late outcomes of mechanical tricuspid valve replacement (mTVR). METHODS: We evaluated 113 patients (82 women; median age, 53 years) who underwent mTVR between 1995 and 2017. Based on a history of cardiac surgery, patients were divided into primary (n=42) and reoperative mTVR (n=71) groups. The median follow-up duration was 12.7 years in primary and 9.3 years in reoperative mTVR, respectively (P=0.045). RESULTS: Patients in the reoperative group were older (54 vs. 46 years; P=0.007) and showed higher central venous pressure (16±6 vs. 13±6 mmHg; P=0.002) than the primary group. Early mortality occurred in 2 patients in the reoperative group (2 vs. 0; P=0.529). There was no significant difference in overall survival between the primary and reoperation groups (15-year survival rate: 86% vs. 78%; P=0.215). The independent risk factors of overall survival were age [P<0.001; hazard ratio (HR), 1.11; 95% confidential interval (CI), 1.05-1.18], left ventricular ejection fraction of less than 40% (P=0.001; HR, 5.1; 95% CI, 2.21-28.2), and central venous pressure over 20 mmHg (P=0.016; HR, 3.7; 95% CI, 1.28-10.7). Overall survival did not differ between the age groups (<60 vs. 60-70 years) in the reoperative group (P=0.772). Tricuspid valve thrombosis occurred in 8 patients (7 primary, 1 reoperative; P=0.004). CONCLUSIONS: The incidence of tricuspid valve thrombosis was significantly higher in the primary mTVR group compared with the reoperative mTVR group. The patients who underwent mTVR at a relatively young age showed good early and late outcomes in both groups.

8.
Thorac Cardiovasc Surg ; 69(1): 26-33, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-31299696

RESUMO

BACKGROUND: Several reports described the repair of sinus of Valsalva aneurysms (SVAs); however, there is still debate regarding the optimal method of operation. We investigated the determinants of the development of significant aortic regurgitation (AR) and long-term survival after surgical repair. METHODS: Between January 1995 and December 2016, 71 patients (31 females; median age: 33.3 years) underwent surgical SVA repair with (n = 60) or without (n = 11) rupture. Aortic valvuloplasty (AVP) was performed using Trusler's technique in 28 patients (39.4%), and 11 patients (15.5%) underwent aortic valve replacement during the first operation. RESULTS: There was no early mortality, and three deaths occurred during follow-up (median: 65.4 months). Patients with grade II preoperative AR who underwent AVP tended to develop significant postoperative AR, but freedom from significant AR did not differ statistically (p = 0.387). Among patients who underwent AVP, freedom from significant AR did not differ statistically between those with grades I and II and those with grades III and IV (p = 0.460). CONCLUSION: Surgical repair of SVA with or without rupture can be performed safely using the dual approach technique. Concomitant aortic valve repair can be performed without difficulty and should be recommended not only for patients with moderate or severe preoperative AR (grades III and IV) but also for those with minimal or mild preoperative AR (grades I and II), whose aortic valve geometry needs correction.


Assuntos
Aneurisma Aórtico/cirurgia , Ruptura Aórtica/cirurgia , Insuficiência da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca , Seio Aórtico/cirurgia , Procedimentos Cirúrgicos Vasculares , Adolescente , Adulto , Aneurisma Aórtico/diagnóstico por imagem , Aneurisma Aórtico/mortalidade , Ruptura Aórtica/diagnóstico por imagem , Ruptura Aórtica/mortalidade , Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/mortalidade , Criança , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Seio Aórtico/diagnóstico por imagem , Fatores de Tempo , Resultado do Tratamento , Procedimentos Cirúrgicos Vasculares/efeitos adversos , Procedimentos Cirúrgicos Vasculares/mortalidade , Adulto Jovem
9.
Ann Thorac Surg ; 111(5): 1502-1511, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33002510

RESUMO

BACKGROUND: This study aimed to evaluate the long-term clinical impacts of prophylactic tricuspid annuloplasty (TAP) in patients with mild tricuspid regurgitation (TR) who underwent mitral valve repair. METHODS: One hundred fifty-one patients with mild TR who underwent mitral valve repair for degenerative mitral regurgitation between 1997 and 2013 were categorized into the TAP (n = 85) or no TAP (n = 66) groups. The indications for TAP were atrial fibrillation and tricuspid annular dilatation. The mean follow-up duration was 115.5 ± 48.6 months. Inverse probability of treatment weighting analysis and propensity score matching with 53 patients in each group were used to adjust for the baseline differences between the 2 groups. RESULTS: There were no early mortalities in either group, and early morbidities, including heart block, were not different between the groups. Inverse probability of treatment weighting-adjusted survival analysis did not reveal any difference in overall survival (P = .862), freedom from cardiac-related mortality (P = .535), or major adverse valve-related events (P = .972) between the groups. There was no difference in late TR progression (moderate or greater) between the groups (P = .316). These results were consistent in the matched analysis. CONCLUSIONS: Prophylactic TAP in mild TR may not have a beneficial effect on TR progress in degenerative mitral regurgitation. Further large studies are necessary to define the role of prophylactic TAP in mild TR.


Assuntos
Anuloplastia da Valva Cardíaca , Insuficiência da Valva Mitral/cirurgia , Procedimentos Cirúrgicos Profiláticos , Insuficiência da Valva Tricúspide/cirurgia , Valva Tricúspide/cirurgia , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/complicações , Estudos Retrospectivos , Índice de Gravidade de Doença , Insuficiência da Valva Tricúspide/complicações
10.
Korean J Thorac Cardiovasc Surg ; 53(5): 306-309, 2020 Oct 05.
Artigo em Inglês | MEDLINE | ID: mdl-33020348

RESUMO

A 59-year-old man presented for possible durable ventricular assist device (VAD) implantation. He had previously been diagnosed with congenitally corrected transposition of the great arteries, a ventricular septal defect, an atrial septal defect, pulmonary valve stenosis, and aortic valve regurgitation. In the previous 22 years, he had undergone palliative cardiac surgery 3 times. VAD implantation as a bridge to transplantation was planned. Owing to severe adhesions, mesocardia, a left ascending aorta, and moderate aortic regurgitation, we performed VAD implantation and aortic valve closure via a dual left thoracotomy and partial sternotomy.

12.
Korean J Thorac Cardiovasc Surg ; 52(2): 109-111, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31089449

RESUMO

We report the case of a female patient who underwent late reoperation following endocarditis surgery. The patient first underwent surgery at 22 years of age for endocarditis with aortic and tricuspid insufficiency. She underwent aortic root replacement with a homograft and tricuspid valve replacement with a tissue valve. Coronary artery bypass using the internal thoracic artery and ligation of the left main coronary artery were performed. Ten years later, failure of the homograft and the tricuspid valve developed. In the second operation, the patient underwent a successful Bentall operation and tricuspid valve replacement with a mechanical valve under deep hypothermia and retrograde cold cardioplegia without drainage.

13.
Ann Thorac Surg ; 108(1): 30-36, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-30716291

RESUMO

BACKGROUND: Currently, two types of cryoprobes are available: nitrous oxide (N2O)-based and argon gas-based. However, few studies have compared the outcomes obtained with these two cryoprobe types. The aim of this study was to compare the early outcomes of a concomitant maze procedure using N2O-based cryoablation (the N2O group) versus argon gas-based cryoablation (the argon group) in patients with persistent atrial fibrillation (AF). METHODS: This study was a single-center, prospective, randomized controlled clinical trial. Sixty patients were randomly assigned to receive a concomitant maze procedure using N2O-based cryoablation (n = 30) or argon gas-based cryoablation (n = 30) for persistent AF. Patients were followed up at 3, 6, and 12 months by electrocardiography, 24-hour Holter monitoring, and transthoracic echocardiography. RESULTS: No important intergroup differences were observed in terms of preoperative variables, morbidity, or mortality. During 1 year of follow-up, normal sinus rhythm was maintained in 26 patients in the N2O group and 26 patients in the argon group (86.7% versus 86.7%, p = 1.000). Freedom from atrial arrhythmia events at 12 months was observed in 84.5% ± 4.7% without intergroup differences. Early AF episode before discharge was correlated with atrial arrhythmia events during follow-up (hazard ratio 7.89, 95% confidence interval: 1.75 to 35, p = 0.007). The N2O group showed earlier recovery of left atrial activity compared with the argon group (p = 0.043); however, this difference disappeared after 6 months. CONCLUSIONS: Both procedures have similar 1-year sinus rhythm maintenance rates. Left atrial contractile activity tends to return earlier in the N2O group.


Assuntos
Argônio/farmacologia , Fibrilação Atrial/cirurgia , Criocirurgia/métodos , Óxido Nitroso/farmacologia , Idoso , Fibrilação Atrial/fisiopatologia , Remodelamento Atrial , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
14.
Heart Lung Circ ; 28(4): 647-654, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29588110

RESUMO

BACKGROUND: Although flexible-ring annuloplasty is more inclined to increase the transmitral gradient over time, its effect on the tricuspid annulus is unknown. This study was conducted to evaluate serial changes in mean pressure gradient (mPG) across tricuspid and mitral valves after simultaneous dual implantation of flexible bands. METHODS: Seventy-one (71) patients (median age, 61.6 years; IQR: 50.8-69.0 years) underwent simultaneous mitral/tricuspid annuloplasties using St. Jude Tailor rings. Serial mPGs across mitral and tricuspid valves were evaluated at three postoperative time points: predischarge, 3 years, and 5 years. To gauge the effects and clinical outcomes of prophylactic intervention, patients were categorised as tricuspid regurgitation (TR)≥moderate or TR

Assuntos
Anuloplastia da Valva Cardíaca/métodos , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Estenose da Valva Tricúspide/cirurgia , Valva Tricúspide/cirurgia , Pressão Ventricular/fisiologia , Idoso , Ecocardiografia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/fisiopatologia , Monitorização Fisiológica/métodos , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/fisiopatologia , Estenose da Valva Tricúspide/diagnóstico , Estenose da Valva Tricúspide/fisiopatologia
15.
Thorac Cardiovasc Surg ; 67(6): 458-466, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-29843185

RESUMO

BACKGROUND: Whether percutaneous coronary intervention (PCI) is superior to coronary artery bypass grafting (CABG) for the right coronary territory is unknown. The aim of this study was to compare the outcomes and patency in the right coronary territory after CABG or PCI. METHODS: We studied 2,467 multivessel coronary artery disease patients from January 2001 to December 2011; 1,672 were off-pump CABG patients and 795 were PCI. The graft patency and the presence of major adverse cardiac and cerebrovascular events (MACCEs) including death, myocardial infarction, target vessel revascularization, and stroke were analyzed. RESULTS: After propensity score matching, cardiac-related survival was found to be significantly higher in the CABG group than in the PCI group (hazard ratio (HR) for the PCI group: 2.445, p = 0.006). The PCI group showed higher rates of myocardial infarction (HR: 2.571, p = 0.011) and target vessel revascularization (HR: 3.337, p < 0.001). In the right coronary territory, the right internal thoracic artery patency was not different in the PCI group compared with the CABG group (p = 0.248). In CABG group, low right coronary artery graft patency was associated with cardiac-related death (HR: 0.17, p = 0.003) and the occurrence of MACCEs (HR: 0.22, p < 0.001). CONCLUSION: CABG was superior to PCI in patients with multivessel disease. Low graft patency in the right coronary territory was associated with cardiac-related death and the occurrence of MACCEs.


Assuntos
Ponte de Artéria Coronária sem Circulação Extracorpórea , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Idoso , Ponte de Artéria Coronária sem Circulação Extracorpórea/efeitos adversos , Ponte de Artéria Coronária sem Circulação Extracorpórea/mortalidade , Doença da Artéria Coronariana/mortalidade , Doença da Artéria Coronariana/fisiopatologia , Doença da Artéria Coronariana/cirurgia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Complicações Pós-Operatórias/mortalidade , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular
16.
JACC Cardiovasc Imaging ; 12(1): 109-119, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30448148

RESUMO

OBJECTIVES: This study assessed diffuse myocardial fibrosis (MF) by cardiac magnetic resonance (CMR) imaging and speckle-tracking echocardiography (STE) in patients with severe aortic stenosis (AS) and validated findings by using histologic confirmation of MF. BACKGROUND: MF is a concomitant pathologic finding related to hypertrophic response in severe AS. It would be beneficial to have reliable imaging methods to assess MF. METHODS: CMR and STE were performed in 71 consecutive patients with severe AS before aortic valve replacement. The extracellular volume (ECV) and native T1 values obtained by CMR and global longitudinal strain (GLS) values by STE were measured. The degree of MF was quantified by using Masson trichrome stain in myocardial biopsy specimens obtained intraoperatively. The study population was divided into 3 groups according to the degree of MF on histology (mild, moderate, and severe MF). RESULTS: The severe MF group had a higher incidence of heart failure (HF) and diastolic dysfunction than the mild and moderate MF groups. The ECV (r = 0.465; p < 0.0001), GLS (r = 0.421; p = 0.0003), and native T1 (r = 0.429; p = 0.0002) values were significantly correlated with the degree of MF. GLS was moderately correlated with ECV (r = 0.455; p = 0.0001) and less with the native T1 (r = 0.372; p = 0.0014) value. The model using ECV (R2 = 0.44; Akaike Information Criterion [AIC] = 55.8) was found to predict the degree of MF most accurately than that with GLS (R2 = 0.35; AIC = 66.84) and the native T1 (R2 = 0.36; AIC = 66.18) value. The secondary endpoint of interest was clinical outcome of a composite of total mortality, admission for HF, or development of HF symptoms. During follow-up (median: 4.6 years), and there were 16 clinical events. Although statistically insignificant, ECV is more closely related to prediction of the clinical outcome than native T1 or GLS. CONCLUSIONS: ECV as assessed by CMR could be an ideal surrogate marker for diffuse MF in patients with severe AS among all 3 models considered.


Assuntos
Estenose da Valva Aórtica/complicações , Ecocardiografia Doppler de Pulso , Hipertrofia Ventricular Esquerda/diagnóstico por imagem , Hipertrofia Ventricular Esquerda/patologia , Imagem Cinética por Ressonância Magnética , Imagem Multimodal/métodos , Miocárdio/patologia , Idoso , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/patologia , Estenose da Valva Aórtica/fisiopatologia , Biópsia , Feminino , Fibrose , Humanos , Hipertrofia Ventricular Esquerda/etiologia , Hipertrofia Ventricular Esquerda/fisiopatologia , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Índice de Gravidade de Doença , Função Ventricular Esquerda , Remodelação Ventricular
17.
J Thorac Dis ; 11(12): 5372-5381, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32030255

RESUMO

BACKGROUND: The present study aimed to compare the long-term clinical and hemodynamic outcomes of aortic valve replacement using Carpentier-Edwards Perimount (Perimount) or Perimount Magna (Magna) valves. METHODS: We enrolled 430 patients who underwent aortic valve replacements with Perimount (n=58) or Magna (n=372) valves [1998-2013]. Multivariable and inverse probability of treatment weight (IPTW) analyses were performed. RESULTS: Before IPTW analysis, the overall 8-year survival rate differed significantly between the groups [Perimount 90%±4% vs. Magna 76%±4%; P=0.02; hazard ratio (HR): 0.37 for the Perimount group; 95% confidence interval (CI): 0.17-0.83]. Multivariable analysis of the overall survival identified Perimount valve use as a protective factor (P=0.009; HR: 0.32; 95% CI: 0.14-0.75). Independent risk factors of overall survival were older age, male sex, higher preoperative left ventricular mass index, lower ejection fraction, lower aortic valve pressure gradient, and lower haemoglobin. After applying IPTW, overall survival was again found to be significantly longer in the Perimount group (P=0.04; HR: 0.43; 95% CI: 0.20-0.93). Event-free survival was also better in the Perimount group (P=0.006; HR: 0.38; 95% CI: 0.19-0.75). However, the Magna group had significantly lower aortic valve pressure gradients at one year and five years postoperative. CONCLUSIONS: Although Magna use led to decreased aortic valve pressure gradients at follow-up, overall and event-free survival rates were significantly better with use of the Perimount valve. Additional and larger studies are needed to confirm these results.

18.
J Korean Med Sci ; 33(42): e267, 2018 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-30310367

RESUMO

BACKGROUND: This study aimed to review the long-term clinical outcomes and graft patency of coronary artery bypass grafting (CABG) using arterial grafts in patients with Kawasaki disease (KD) affecting the coronary artery. METHODS: Twenty patients with KD who underwent CABG from January 2002 to June 2014 were enrolled. There were 4 male (20%) and 16 female (80%) patients with ages at operation ranging from 2 to 42 years (median, 17.5 years). Our routine operative strategy was off-pump CABG with arterial grafts. The mean follow-up duration was 59.5 ± 48.5 months (range, 1-159 months). Coronary angiogram or computed tomography angiogram was used to evaluate graft patency in 16 patients (80%). RESULTS: All patients survived CABG without late mortality. Left internal thoracic arteries were used in 19 patients, while right internal thoracic arteries were used in 10 patients. Right gastroepiploic arteries were used in 3 patients, and a saphenous vein graft (SVG) was used in 1 patient. Among the 20 patients, 2 patients underwent coronary reintervention with balloon angioplasty because of graft failure. Two patients underwent coronary reintervention because of new obstructive lesions that were not significant at the time of the initial operation. Patency rates at 5 and 10 years were 94% and 87%, respectively. The rate of freedom from coronary reintervention at 10 years was 82%. CONCLUSION: Off-pump CABG with mainly arterial graft revascularization may be considered a good surgical option for coronary lesions caused by KD.


Assuntos
Ponte de Artéria Coronária , Vasos Coronários/cirurgia , Síndrome de Linfonodos Mucocutâneos/terapia , Adolescente , Adulto , Angioplastia com Balão , Criança , Pré-Escolar , Ponte de Artéria Coronária sem Circulação Extracorpórea , Feminino , Humanos , Masculino , Síndrome de Linfonodos Mucocutâneos/patologia , República da Coreia , Estudos Retrospectivos , Adulto Jovem
19.
Heart Surg Forum ; 21(4): E263-E268, 2018 06 18.
Artigo em Inglês | MEDLINE | ID: mdl-30084776

RESUMO

BACKGROUND: Repeated thoracic aorta repair is increasingly common. With the increase in hybrid procedures, determination of the best treatment strategy requires evaluation of the clinical outcomes of classic open surgery. METHODS: We retrospectively reviewed 119 patients (84 men and 35 women, aged 51.0 ± 16.7 years) with a history of open repair involving the thoracic aorta above the diaphragm. The patients underwent an average of 1.3 ± 0.8 surgeries (range: 1-8) on the thoracic aorta before the final operation. Clinical outcomes were evaluated on the basis of the need for emergency surgery, indications for surgery, pathologic causes, and other operative variables. RESULTS: Hospital mortality was 6.7% (n = 8). Postoperative bleeding occurred in 16% (n = 19). On multivariable analysis, emergency surgery (odds ratio [OR], 19.005; P = .003; 95% confidence interval [CI], 2.710-133.305) and cardiopulmonary bypass (CPB) time (OR, 1.562 per 30 minutes; P = .007; 95% CI, 1.126-2.165) were predictors of hospital death. Emergency surgery (OR, 4.105; P = .029; 95% CI, 1.157-14.567) and CPB time (OR, 1.189 per 30 minutes; P = .035; 95% CI, 1.012-1.396) were also associated with postoperative bleeding, in addition to surgery for an infectious cause (OR, 10.824; P = .010; 95% CI, 1.755-66.770). Estimated survival at 1, 5, and 7 years was 86.6%, 80.5%, and 78.2%, respectively. CONCLUSION: Despite the variety of preoperative conditions and operations performed, repeated open surgery for thoracic aorta repair can be performed with acceptable early and late outcomes.


Assuntos
Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Dissecção Aórtica/cirurgia , Complicações Pós-Operatórias/mortalidade , Procedimentos Cirúrgicos Vasculares/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Dissecção Aórtica/mortalidade , Aneurisma da Aorta Torácica/mortalidade , Feminino , Seguimentos , Mortalidade Hospitalar/tendências , Humanos , Masculino , Pessoa de Meia-Idade , República da Coreia/epidemiologia , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento , Adulto Jovem
20.
Circ J ; 82(10): 2535-2541, 2018 09 25.
Artigo em Inglês | MEDLINE | ID: mdl-30068855

RESUMO

BACKGROUND: This study aimed to evaluate the early and late clinical outcomes after repeat aortic valve replacement (AVR) for subaortic pannus in patients with mechanical valves. Methods and Results: Between 2001 and 2017, 51 patients (median age, 59 years; 42 women) with prosthetic aortic stenosis (AS) caused by pannus ingrowth underwent repeat AVR because of acute malfunction of monoleaflet valve (3 patients), severe prosthetic AS (30 patients), and moderate prosthetic AS at the time of tricuspid or mitral valve surgery (18 patients). The median follow-up duration was 100 (interquartile range, 64-138) months. Double valve replacement was performed in 45 (88%) patients. Median time interval from previous operation was 161 (interquartile range, 121-194) months. The explanted mechanical AV was monoleaflet and bileaflet in 16 (31%) and 34 (67%) patients, respectively. Concomitant procedures included 16 mitral valve replacements (14 repeat) and 36 tricuspid valve surgeries (15 replacements, 21 repairs). No hospital deaths or cases of heart block occurred. Overall survival and event-free survival rates at 10 years were 88% and 51%, respectively. Late complications included recurrent prosthetic AS (4 patients), new paravalvular leakage of the mitral valve (5 patients), and severe tricuspid regurgitation (2 patients). CONCLUSIONS: Although repeat AVR for subaortic pannus had acceptable early and late survival, recurrent prosthetic AS was frequently observed during late follow-up.


Assuntos
Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca , Reoperação/estatística & dados numéricos , Idoso , Estenose da Valva Aórtica , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/cirurgia , Falha de Prótese , Fatores de Tempo , Resultado do Tratamento , Valva Tricúspide/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA