Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
2.
Rev Esp Cardiol (Engl Ed) ; 76(7): 531-538, 2023 Jul.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-36427787

RESUMO

INTRODUCTION AND OBJECTIVES: The use of a pressure wire as a jailed wire to evaluate side branch results during provisional stenting seems feasible. However, safety concerns exist due to the mechanical damage of the wire and the lack of prospective data evaluating the prognosis of patients treated using this technique. This study sought to evaluate the structural damage of the pressure wire in patients treated using the jailed pressure wire technique and to assess mid-term clinical outcomes. METHODS: We enrolled 99 patients with single bifurcation lesions and provisional stenting as the strategy of choice. A jailed pressure wire was used to guide side branch intervention according to the instantaneous wave-free ratio (iFR). A total of 114 patients and the respective nonpolymer-coated jailed wires were used as historical controls. Guidewire damage was evaluated by stereomicroscopy. The primary endpoint was significant microscopic damage. Major adverse cardiac events were evaluated at 2-year follow-up. RESULTS: Significant microscopic damage was more frequent in pressure wires than in nonpolymer-coated wires (53.5% vs 22.8%, P<.001). There were no fractures in either group. There were fewer side branch interventions in the pressure wire group (postdilation/kissing balloon, 32.3% vs 56.1%, P=.001; stenting, 0.0% vs 2.6%, P=.104). The 2-year rate of major adverse cardiac events was similar between the 2 groups (HRadj, 0.42; 95%CI, 0.10-1.73; P=.229). CONCLUSIONS: Pressure wires were less resistant to jailing than conventional nonpolymer-coated wires. Patients treated with iFR-guided provisional stenting required fewer side branch interventions but had similar 2-year clinical outcomes than patients treated with the angiography-guided technique.


Assuntos
Angioplastia Coronária com Balão , Doença da Artéria Coronariana , Humanos , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/cirurgia , Doença da Artéria Coronariana/etiologia , Angioplastia Coronária com Balão/métodos , Prognóstico , Stents , Angiografia Coronária , Resultado do Tratamento
3.
Med Clin (Barc) ; 159(2): 78-84, 2022 07 22.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-35074177

RESUMO

AIM: Amyloidosis is a disease in which amyloid fibrils can be deposited in different cardiac structures, and several electrocardiographic abnormalities can be produced by this phenomenon. The objective of this study was to describe the most common basal electrocardiographic alterations in patients diagnosed with cardiac amyloidosis (CA) and to determine if these abnormalities have an impact on the need of pacemaker. METHODS: This retrospective study included patients who had an established diagnosis of CA [light-chain cardiac amyloidosis (LA-CA) or transthyretin cardiac amyloidosis (TTR-CA)] between January 2013 and March 2021. The baseline heart rate, the percentage of patients with a pseudo-infarct pattern, low-voltage pattern or cardiac conductions disturbances, and the impact of these factors on the need of pacemaker were analysed. RESULTS: Fifty-eight patients with CA (20 with LA-CA and 38 with TTR-CA) were included, and the majority were male (69.0%). Twenty-one patients had atrial fibrillation (AF) at diagnosis. Thirty-five patients had a pseudo-infarct pattern, 35% had a low-voltage pattern, and 22% had criteria for ventricular hypertrophy. Two hirds had a conduction disorder: 18 patients with first degree atrioventricular block, 12 right bundle branch block, 3 left bundle branch block and 25 with a branch hemiblock. There were no differences between LA-CA and TTR-CA. Patients with TTR-CA had a greater need for pacemakers in the folow-up (39±40 meses). Bundle branch block was a predictor of the need for a permanent pacemaker (HR: 23.43; CI 95%: 4.09.134.09; P=.01). CONCLUSIONS: Electrocardiographic abnormalities in patients diagnosed wich CA are heterogeneus. Most frecuent is the presence of conduction disorders, the pseudoinfarction pattern, followed by the low voltage pattern. Patients with any bundle branch block at the baseline electrocardiogram need more frecuent to require a pacemaker during follow-up, especially in TTR-CA.


Assuntos
Amiloidose , Fibrilação Atrial , Marca-Passo Artificial , Amiloidose/complicações , Amiloidose/diagnóstico , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/etiologia , Bloqueio de Ramo/terapia , Doença do Sistema de Condução Cardíaco , Eletrocardiografia , Feminino , Bloqueio Cardíaco , Humanos , Infarto , Masculino , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA