Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Appl Environ Microbiol ; 90(6): e0024424, 2024 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-38780510

RESUMO

Ribosomally synthesized and post-translationally modified peptides (RiPPs) are a broad group of compounds mediating microbial competition in nature. Azole/azoline heterocycle formation in the peptide backbone is a key step in the biosynthesis of many RiPPs. Heterocycle formation in RiPP precursors is often carried out by a scaffold protein, an ATP-dependent cyclodehydratase, and an FMN-dependent dehydrogenase. It has generally been assumed that the orchestration of these modifications is carried out by a stable complex including the scaffold, cyclodehydratase, and dehydrogenase. The antimicrobial RiPP micrococcin begins as a precursor peptide (TclE) with a 35-amino acid N-terminal leader and a 14-amino acid C-terminal core containing six Cys residues that are converted to thiazoles. The putative scaffold protein (TclI) presumably presents the TclE substrate to a cyclodehydratase (TclJ) and a dehydrogenase (TclN) to accomplish the two-step installation of the six thiazoles. In this study, we identify a minimal TclE leader region required for thiazole formation, demonstrate complex formation between TclI, TclJ, and TclN, and further define regions of these proteins required for complex formation. Our results point to a mechanism of thiazole installation in which TclI associates with the two enzymes in a mutually exclusive fashion, such that each enzyme competes for access to the peptide substrate in a dynamic equilibrium, thus ensuring complete modification of each Cys residue in the TclE core. IMPORTANCE: Thiopeptides are a family of antimicrobial peptides characterized for having sulfur-containing heterocycles and for being highly post-translationally modified. Numerous thiopeptides have been identified; almost all of which inhibit protein synthesis in gram-positive bacteria. These intrinsic antimicrobial properties make thiopeptides promising candidates for the development of new antibiotics. The thiopeptide micrococcin is synthesized by the ribosome and undergoes several post-translational modifications to acquire its bioactivity. In this study, we identify key interactions within the enzymatic complex that carries out cysteine to thiazole conversion in the biosynthesis of micrococcin.


Assuntos
Bacteriocinas , Cisteína , Tiazóis , Tiazóis/metabolismo , Cisteína/metabolismo , Bacteriocinas/metabolismo , Bacteriocinas/química , Bacteriocinas/genética , Proteínas de Bactérias/metabolismo , Proteínas de Bactérias/genética , Proteínas de Bactérias/química , Processamento de Proteína Pós-Traducional , Escherichia coli/genética , Escherichia coli/metabolismo
2.
Clin Proteomics ; 21(1): 23, 2024 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-38481131

RESUMO

BACKGROUND: Human tear protein biomarkers are useful for detecting ocular and systemic diseases. Unfortunately, existing tear film sampling methods (Schirmer strip; SS and microcapillary tube; MCT) have significant drawbacks, such as pain, risk of injury, sampling difficulty, and proteomic disparities between methods. Here, we present an alternative tear protein sampling method using soft contact lenses (SCLs). RESULTS: We optimized the SCL protein sampling in vitro and performed in vivo studies in 6 subjects. Using Etafilcon A SCLs and 4M guanidine-HCl for protein removal, we sampled an average of 60 ± 31 µg of protein per eye. We also performed objective and subjective assessments of all sampling methods. Signs of irritation post-sampling were observed with SS but not with MCT and SCLs. Proteomic analysis by mass spectrometry (MS) revealed that all sampling methods resulted in the detection of abundant tear proteins. However, smaller subsets of unique and shared proteins were identified, particularly for SS and MCT. Additionally, there was no significant intrasubject variation between MCT and SCL sampling. CONCLUSIONS: These experiments demonstrate that SCLs are an accessible tear-sampling method with the potential to surpass current methods in sampling basal tears.

3.
bioRxiv ; 2023 Oct 23.
Artigo em Inglês | MEDLINE | ID: mdl-37961320

RESUMO

Ribosomally synthesized and post-translationally modified peptides (RiPPs) are a broad group of compounds mediating microbial competition in nature. Azole/azoline heterocycle formation in the peptide backbone is a key step in the biosynthesis of many RiPPs. Heterocycle formation in RiPP precursors is often carried out by a scaffold protein, an ATP-dependent cyclodehydratase, and an FMN-dependent dehydrogenase. It has generally been assumed that the orchestration of these modifications is carried out by a stable complex including the scaffold, cyclodehydratase and dehydrogenase. The antimicrobial RiPP micrococcin begins as a precursor peptide (TclE) with a 35-amino acid N-terminal leader and a 14-amino acid C-terminal core containing six Cys residues that are converted to thiazoles. The putative scaffold protein (TclI) presumably presents the TclE substrate to a cyclodehydratase (TclJ) and a dehydrogenase (TclN) to accomplish the two-step installation of the six thiazoles. In this study, we identify a minimal TclE leader region required for thiazole formation, we demonstrate complex formation between TclI, TclJ and TclN, and further define regions of these proteins required for complex formation. Our results point to a mechanism of thiazole installation in which TclI associates with the two enzymes in a mutually exclusive fashion, such that each enzyme competes for access to the peptide substrate in a dynamic equilibrium, thus ensuring complete modification of each Cys residue in the TclE core.

4.
J Chromatogr A ; 1701: 464044, 2023 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-37196519

RESUMO

Offline peptide separation (PS) using high-performance liquid chromatography (HPLC) is currently used to enhance liquid chromatography-tandem mass spectrometry (LC-MS/MS) detection of proteins. In search of more effective methods for enhancing MS proteome coverage, we developed a robust method for intact protein separation (IPS), an alternative first-dimension separation technique, and explored additional benefits that it offers. Comparing IPS to the traditional PS method, we found that both enhance detection of unique protein IDs to a similar magnitude, though in diverse ways. IPS was especially effective in serum, which has a small number of extremely high abundance proteins. PS was more effective in tissues with fewer dominating high-abundance proteins and was more effective in enhancing detection of post-translational modifications (PTMs). Combining the IPS and PS methods together (IPS+PS) was especially beneficial, enhancing proteome detection more than either method could independently. The comparison of IPS+PS versus six PS fractionation pools increased total number of proteins IDs by nearly double, while also significantly increasing number of unique peptides detected per protein, percent peptide sequence coverage of each protein, and detection of PTMs. This IPS+PS combined method requires fewer LC-MS/MS runs than current PS methods would need to obtain similar improvements in proteome detection, and it is robust, time- and cost-effective, and generally applicable to various tissue and sample types.


Assuntos
Proteoma , Proteômica , Cromatografia Líquida de Alta Pressão/métodos , Cromatografia Líquida/métodos , Proteoma/análise , Proteômica/métodos , Espectrometria de Massas em Tandem , Peptídeos/análise
5.
J Sep Sci ; 43(9-10): 1623-1627, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-31960568

RESUMO

A newly developed portable capillary liquid chromatograph was investigated for the separation of various pharmaceutical and illicit drug compounds. The system consists of two high-pressure syringe pumps capable of delivering capillary-scale flow rates at pressures up to 10 000 psi. Capillary liquid chromatography columns packed with sub-2 µm particles are housed in cartridges that can be inserted into the system and easily connected through high-pressure fluidic contact points by simply applying a specific, predetermined torque rather than using standard fittings and less precise sealing protocols. Several over-the-counter analgesic drug separations are demonstrated, along with a simple online measurement of tablet dissolution. Twenty illicit drug compounds were also separated across six targeted drug panels. The results described in this study demonstrate the capability of this compact liquid chromatography instrument to address several important drug-related applications while simplifying system operation, and greatly reducing solvent usage and waste generation essential for onsite analysis.


Assuntos
Drogas Ilícitas/análise , Cromatografia Líquida/instrumentação , Ciências Forenses/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA