Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros








Intervalo de ano de publicação
1.
Clin Exp Optom ; 107(7): 691-697, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39025787

RESUMO

Amblyopia is the most frequent cause of monocular vision loss. Transcranial Magnetic Stimulation (TMS) has been used to improve several vision parameters of the amblyopic eye in adulthood. This study is relevant in order to evaluate TMS effects and to raise awareness of the need for further research. Transcranial Magnetic Stimulation (TMS) is a neuromodulation technique capable of changing cortical excitability. In the last decade, it has been used to improve visual parameters in amblyopic patients. The main goal of this systematic review is to evaluate the influence of TMS in the amblyopic eye, in the visual parameters of amblyopic patients. Searches were done in PubMed and Embase databases, and a combined search strategy was performed using the following Mesh, EMBASE, and keywords: 'Amblyopia', 'Transcranial Magnetic Stimulation', and 'theta burst stimulation'. This review included randomised controlled studies, descriptive cases, and clinical case studies with adult amblyopes. All articles that had any of the following characteristics were excluded: children or animal studies, reviews, pathologies other than amblyopia, and other techniques rather than repetitive TMS (rTMS), or Theta Burst Stimulation (TBS). A total of 42 articles were found, of which only four studies (46 amblyopes) meet the criteria above. Three of the articles found significant improvement after one session of continuous TBS (cTBS) in visual parameters like visual acuity, contrast sensitivity, suppressive imbalance, and stereoacuity. One study found a significant visual improvement with 10 Hz rTMS. Only one stimulation-related dropout was reported. The few existing studies found in this review seem to show that through the usage of high-frequency rTMS and cTBS, it is possible to re-balance the eyes of an adult amblyope. However, despite the promising results, further research with larger randomised double-blind studies is needed for a better understanding of this process.


Assuntos
Ambliopia , Estimulação Magnética Transcraniana , Acuidade Visual , Córtex Visual , Ambliopia/terapia , Ambliopia/fisiopatologia , Humanos , Estimulação Magnética Transcraniana/métodos , Córtex Visual/fisiopatologia , Córtex Visual/fisiologia , Acuidade Visual/fisiologia , Adulto
2.
Clin Neurophysiol ; 163: 174-184, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38759513

RESUMO

OBJECTIVE: This systematic review aimed to evaluate if event-related potentials (ERPs) can be a relevant tool for cognitive dysfunction diagnosis in Multiple Sclerosis (MS). METHODS: Four databases were consulted (PubMed, Embase, Scielo, and Web of Science). The included studies should include adults with clear MS diagnoses, independently of having cognitive complaints, and all should have been submitted to ERPs (P300, N400 or mismatch negativity (MMN)). The main outcomes evaluated were ERPs' amplitude and/or latency. RESULTS: 425 studies were obtained initially from all databases, with 26 studies fulfilling the eligibility criteria. P300 was the most used ERP (25 studies), showing a reduced amplitude or an increased latency in 84% of those. N400 was evaluated in one study, showing also abnormal results. MMN was addressed in two studies with inconsistent findings. Some studies further suggest that ERPs may show earlier abnormal results compared with neuropsychological tests. CONCLUSIONS: Most MS patient groups revealed ERP abnormalities, suggesting that these neurophysiological tests may be a relevant and appropriate diagnostic aid method for cognitive impairment in MS. SIGNIFICANCE: The use of ERPs in MS patients seems able to demonstrate cognitive impairment and its use should be considered as part of the regular patient evaluation.


Assuntos
Potenciais Evocados , Esclerose Múltipla , Humanos , Esclerose Múltipla/fisiopatologia , Esclerose Múltipla/complicações , Potenciais Evocados/fisiologia , Disfunção Cognitiva/fisiopatologia , Disfunção Cognitiva/etiologia , Disfunção Cognitiva/diagnóstico , Eletroencefalografia/métodos
3.
Int Ophthalmol ; 44(1): 86, 2024 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-38363441

RESUMO

INTRODUCTION: Amblyopia is generally a unilateral disorder, defined by at least a difference of two lines of visual acuity between both eyes with the best-corrected visual acuity, a decrease in contrast sensitivity, and a decrease in stereopsis. Pattern electroretinogram (PERG) is a noninvasive technique that provides a retinal biopotential and is a highly sensitive indicator of changes in the macular area. Our aim was to evaluate if there are differences in the retinal response of an amblyopic eye compared with a normal eye (NE). METHODS: We evaluated twenty-four adult volunteers, twelve amblyopes (mean 43.42 ± 12.72 years old), and twelve subjects with NE (mean 35.58 ± 12.85 years old). None of the subjects in the two groups had comorbidities. A complete optometric examination was performed including parameters such as visual acuity (VA) by far and near with ETDRS chart, eye alignment with cover test, and evaluation of retinal cells response with PERG. RESULTS: The refractive error found in the NE group of subjects had a mean of - 0.95 ± 1.65D, while the amblyopic group showed a mean of - 2.03 ± 4.29D. The VA in amblyopic eyes had a mean of 0.38 ± 0.20 logMAR. Analyzing PERG data, we observed significant differences in the P50-N95 amplitudes of the amblyopic group compared with the NE group (p < 0.0001-amblyopic eye vs. NE; p = 0.039-fellow eye vs. NE). DISCUSSION: These findings suggest that amblyopic patients may also present other impairments beyond the visual cortex. PERGs seem to be an important complementary examination in the diagnosis of other impairments in amblyopia.


Assuntos
Ambliopia , Erros de Refração , Adulto , Humanos , Pessoa de Meia-Idade , Adulto Jovem , Ambliopia/diagnóstico , Eletrorretinografia , Acuidade Visual , Retina/diagnóstico por imagem
4.
Int Ophthalmol ; 42(9): 2785-2799, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35353292

RESUMO

PURPOSE: Theta Burst Stimulation can influence adult neuro-visual response in imbalanced visual pathways, possibly by influencing cortical excitability. Our objective was to compare suppressive imbalance (SI) and visual acuity (VA) after applying repetitive Transcranial Magnetic Stimulation between groups of subjects with normal binocular vision, visual asymmetry, and amblyopia. METHODS: Thirty-five volunteers between 19 and 51 years of age were split into three groups: 6 volunteers with asymmetric VA (group A); 19 amblyopes (group B); and 10 subjects with normal binocular vision (group C). VA and SI of all groups were evaluated before and after a single session of continuous Theta Burst Stimulation (cTBS) or placebo stimulation over the right occipital cortex. RESULTS: In both groups A and B, we found a significant VA improvement in the non-dominant eye after cTBS (p = 0.04 and p = 0.01, respectively). In SI evaluation, group A and group B also revealed a significant improvement after the cTBS session (p = 0.03 and p = 0.01, respectively). Finally, in the group of volunteers with normal binocular vision and for placebo groups A and B, there were no significant differences in VA and SI after cTBS. CONCLUSIONS: Amblyopic and visually asymmetric individuals improved VA and SI of the non-dominant eye after cTBS when compared to baseline and to placebo stimulation. These enhancements were not found in the group of volunteers with normal binocular vision. We can therefore reasonably assume that cTBS may interfere with the visual system of subjects that present some kind of asymmetry, possibly by improving neuronal imbalances.


Assuntos
Ambliopia , Estimulação Magnética Transcraniana , Adulto , Humanos , Pessoa de Meia-Idade , Visão Binocular , Acuidade Visual
5.
Neuropsychobiology ; 80(4): 288-298, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33395687

RESUMO

INTRODUCTION: Theta-burst stimulation (TBS) is a safe non-invasive neurostimulation technique used to improve cognitive and neuropsychiatric impairments. Combined outcome evaluation using event-related potentials (ERPs) and neuropsychological tests may allow a more thorough assessment of TBS treatment efficacy; however, some mixed results have been found, and their use remains scarce. Our main objective was to evaluate whether a session of TBS to the left dorsolateral prefrontal cortex (DLPFC) can impact upon the performance of both neuropsychological and neurophysiological tests. METHODS: This double-blind sham-controlled study involved 28 healthy adults, between 18 and 30 years. Volunteers were randomly allocated to receive excitatory (intermittent [iTBS]), inhibitory (continuous TBS [cTBS]) or sham stimulation on the left DLPFC. Subjects were evaluated using ERPs (auditory oddball paradigm P300) and neuropsychological tests (Trail making test [TMT] and Stroop test of words and colours [STWC]), using a pre-post stimulation protocol. RESULTS: Inhibitory stimulation led to significantly delayed P300 peak latencies (p < 0.001), with no consistent change in N2P3 amplitudes. cTBS also significantly influenced the expected group performance in Stroop C and Stroop interference (p = 0.025) compared to the iTBS and sham groups. No significant results were found in TMT tests after TBS. CONCLUSION: Our results suggest that P300 and specific Stroop colour and words test parameters can be similarly influenced by the same TBS protocol. This emphasizes the importance of mixed evaluation using neuropsychological and neurophysiological resources in research associated with the use of transcranial magnetic stimulation and cognition.


Assuntos
Córtex Pré-Frontal Dorsolateral , Estimulação Magnética Transcraniana , Adulto , Cognição , Método Duplo-Cego , Humanos , Testes Neuropsicológicos , Córtex Pré-Frontal
6.
J Neuroophthalmol ; 40(2): 185-192, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-31453915

RESUMO

BACKGROUND: Through transcranial magnetic stimulation (TMS) it is possible to change cortical excitability of the visual cortex, and to influence binocular balance. The main goal of our study is to assess the effect of transcranial magnetic stimulation, specifically theta burst stimulation (TBS), in a group of amblyopic volunteers measuring several visual parameters: visual acuity, suppressive imbalance, and stereoacuity. METHODS: Thirteen volunteers aged 19 to 24 years, randomly split in 2 groups, underwent 1 session of continuous TBS, stimulating the right occipital lobe. The first group with 8 volunteers was exposed to active stimulation with cTBS, and the other group with 5 volunteers was exposed to placebo stimulation. RESULTS: Significant improvements in visual acuity, suppressive imbalance, and stereoacuity were found in the amblyopic eye after cTBS. The average value of amblyopia in visual acuity before stimulation was 0.32 ± 0.20 logMar and after cTBS was 0.19 ± 0.17 logMar. The mean value for the control group before placebo stimulation was 0.28 ± 0.17 and after placebo stimulation was 0.28 ± 0.16. The suppressive imbalance in the group of amblyope subjects stimulated before cTBS was 0.26 ± 0.18 and after was 0.12 ± 0.12; the suppressive imbalance of the control group before the placebo stimulation was 0.34 ± 0.37 and after was 0.32 ± 0.40. CONCLUSIONS: Visual acuity, suppressive imbalance, and stereoacuity had significant enhancements compared with baseline after cTBS over the right occipital lobe in an ambliopic population.


Assuntos
Ambliopia/terapia , Estimulação Magnética Transcraniana/métodos , Acuidade Visual , Córtex Visual/fisiopatologia , Adulto , Ambliopia/fisiopatologia , Feminino , Humanos , Masculino , Resultado do Tratamento , Adulto Jovem
7.
PLoS One ; 13(1): e0190693, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29304065

RESUMO

Theta-burst stimulation (TBS) can be a non-invasive technique to modulate cognitive functions, with promising therapeutic potential, but with some contradictory results. Event related potentials are used as a marker of brain deterioration and can be used to evaluate TBS-related cognitive performance, but its use remains scant. This study aimed to study bilateral inhibitory and excitatory TBS effects upon neurocognitive performance of young healthy volunteers, using the auditory P300' results. Using a double-blind sham-controlled study, 51 healthy volunteers were randomly assigned to five different groups, two submitted to either excitatory (iTBS) or inhibitory (cTBS) stimulation over the left dorsolateral pre-frontal cortex (DLPFC), two other actively stimulated the right DLPFC and finally a sham stimulation group. An oddball based auditory P300 was performed just before a single session of iTBS, cTBS or sham stimulation and repeated immediately after. P300 mean latency comparison between the pre- and post-TBS stimulation stages revealed significantly faster post stimulation latencies only when iTBS was performed on the left hemisphere (p = 0.003). Right and left hemisphere cTBS significantly delayed P300 latency (right p = 0.026; left p = 0.000). Multiple comparisons for N200 showed slower latencies after iTBS over the right hemisphere. No significant difference was found in amplitude variation. TBS appears to effectively influence neural networking involved in P300 formation, but effects seem distinct for iTBS vs cTBS and for the right or the left hemisphere. P300 evoked potentials can be an effective and practical tool to evaluate transcranial magnetic stimulation related outcomes.


Assuntos
Encéfalo/fisiologia , Potenciais Evocados P300 , Estimulação Magnética Transcraniana/métodos , Adolescente , Adulto , Método Duplo-Cego , Feminino , Humanos , Masculino , Tempo de Reação , Adulto Jovem
8.
Arq Bras Oftalmol ; 77(1): 21-4, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25076368

RESUMO

PURPOSE: Translate and adapt the Convergence Insuficiency Symptom Survey (CISS) questionnaire to the Portuguese language and culture and assess the psychometric properties of the translated questionnaire (CISSvp). METHODS: The CISS questionnaire was adapted according to the methodology recommended by some authors. The process involved two translations and back-translations performed by independent evaluators, evaluation of these versions, preparation of a synthesis version and its pre-test. The final version (CISSvp) was applied in 70 patients (21.79 ± 2.42 years) students in higher education, and at two different times, by two observers, to assess its reliability. RESULTS: The results showed good internal consistency of the CISSvp (Cronbach's alpha - α=0.893). The test re-test revealed an average of the differences between the first and second evaluation of 0.75 points (SD ± 3.53), which indicates a minimum bias between the two administrations. The interrater reliability assessed by intraclass correlation coefficient ranged from 0.880 to 0.952, revealing that the CISSvp represents an appropriate tool for measuring the visual discomfort associated with near vision tasks with a high level of reproducibility. CONCLUSIONS: The CISS Portuguese version, showed good psychometric properties and has been sown to be applicable to the Portuguese population, to quantify the visual discomfort associated with near vision, in higher education students.


Assuntos
Astenopia/diagnóstico , Transtornos da Motilidade Ocular/diagnóstico , Inquéritos e Questionários , Traduções , Adolescente , Adulto , Brasil , Comparação Transcultural , Feminino , Humanos , Idioma , Masculino , Psicometria , Reprodutibilidade dos Testes , Adulto Jovem
9.
Arq. bras. oftalmol ; 77(1): 21-24, Jan-Feb/2014. tab
Artigo em Inglês | LILACS | ID: lil-715564

RESUMO

Purpose: Translate and adapt the Convergence Insuficiency Symptom Survey (CISS) questionnaire to the Portuguese language and culture and assess the psychometric properties of the translated questionnaire (CISSvp). Methods: The CISS questionnaire was adapted according to the methodology recommended by some authors. The process involved two translations and back-translations performed by independent evaluators, evaluation of these versions, preparation of a synthesis version and its pre-test. The final version (CISSvp) was applied in 70 patients (21.79 ± 2.42 years) students in higher education, and at two different times, by two observers, to assess its reliability. Results: The results showed good internal consistency of the CISSvp (Cronbach's alpha - α=0.893). The test re-test revealed an average of the differences between the first and second evaluation of 0.75 points (SD ± 3.53), which indicates a minimum bias between the two administrations. The interrater reliability assessed by intraclass correlation coefficient ranged from 0.880 to 0.952, revealing that the CISSvp represents an appropriate tool for measuring the visual discomfort associated with near vision tasks with a high level of reproducibility. Conclusions: The CISS Portuguese version, showed good psychometric properties and has been sown to be applicable to the Portuguese population, to quantify the visual discomfort associated with near vision, in higher education students. .


Objetivo: Traduzir e adaptar transculturalmente o questionário Convergence Insuficiency Symptom Survey (CISS) para a língua portuguesa e avaliar as propriedades psicométricas do questionário traduzido (CISSvp). Métodos: O questionário CISS foi adaptado segundo metodologia recomendada por alguns autores. O processo envolveu duas traduções e retrotraduções realizadas por avaliadores independentes, avaliação das versões seguida da elaboração de uma versão síntese e pré-teste comentado. A versão final (CISSvp) foi aplicada em 70 indivíduos (21,79 ± 2,42 anos) estudantes do ensino superior, em dois momentos distintos e por dois observadores, para avaliar a confiabilidade do mesmo. Resultados: Os resultados evidenciaram boa consistência interna do CISSvp (alfa de Cronbach - α=0,893). O teste re-teste revelou uma media das diferenças entre a primeira e a segunda avaliação de 0,75 pontos (SD=±3,53) o que indica um viés mínimo entre as duas administrações. A confiabilidade inter-examinadores avaliada pelo coeficiente de correlação intraclasse variou de 0,880 e 0,952, revelando que o CISSvp representa uma ferramenta de medida do desconforto visual associado a tarefas em visão próxima com um nível de reprodutibilidade elevado. Conclusões: O CISS versão portuguesa apresentou boas propriedades psicométricas e demonstrou ser aplicável na população portuguesa, para quantificar a o desconforto visual associado à visão de perto, em estudantes do ensino superior. .


Assuntos
Adolescente , Adulto , Feminino , Humanos , Masculino , Adulto Jovem , Astenopia/diagnóstico , Transtornos da Motilidade Ocular/diagnóstico , Inquéritos e Questionários , Traduções , Brasil , Comparação Transcultural , Idioma , Psicometria , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA