Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Hum Vaccin Immunother ; 20(1): 2311480, 2024 Dec 31.
Artigo em Inglês | MEDLINE | ID: mdl-38608171

RESUMO

Six serotypes (Ia, Ib, II, III, IV, and V) cause nearly all group B streptococcal (GBS) disease globally. Capsular polysaccharide (CPS) conjugate vaccines aim to prevent GBS disease, however, licensure of a vaccine would depend on a standardized serological assay for measuring anti-CPS IgG responses. A multiplex direct Luminex-based immunoassay (dLIA) has been developed to simultaneously measure the concentration of serum IgG specific for the six prevalent GBS CPS serotypes. Assay validation was performed using serum samples obtained from human subjects vaccinated with an investigational 6-valent GBS CPS conjugate vaccine. Results for the assay are expressed as IgG concentrations (µg/mL) using a human serum reference standard composed of pooled sera from vaccinated subjects. The lower limits of quantitation (LLOQ) for all serotypes covered in the 6-plex GBS IgG dLIA fell within the range of 0.002-0.022 µg/mL IgG. Taken together, the 6-plex GBS IgG dLIA platform is specific for the six GBS serotypes included in Pfizer's investigational vaccine, has a wide dilution adjusted assay range, and is precise (<18.5% relative standard deviation) for all serotypes, and, therefore, is suitable for quantitatively measuring vaccine-induced or naturally acquired serotype-specific anti-CPS IgG responses against GBS.


Assuntos
Licenciamento , Polissacarídeos , Humanos , Streptococcus agalactiae , Vacinas Conjugadas , Imunoglobulina G
2.
N Engl J Med ; 389(3): 215-227, 2023 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-37467497

RESUMO

BACKGROUND: Natural history studies have correlated serotype-specific anti-capsular polysaccharide (CPS) IgG in newborns with a reduced risk of group B streptococcal disease. A hexavalent CPS-cross-reactive material 197 glycoconjugate vaccine (GBS6) is being developed as a maternal vaccine to prevent invasive group B streptococcus in young infants. METHODS: In an ongoing phase 2, placebo-controlled trial involving pregnant women, we assessed the safety and immunogenicity of a single dose of various GBS6 formulations and analyzed maternally transferred anti-CPS antibodies. In a parallel seroepidemiologic study that was conducted in the same population, we assessed serotype-specific anti-CPS IgG concentrations that were associated with a reduced risk of invasive disease among newborns through 89 days of age to define putative protective thresholds. RESULTS: Naturally acquired anti-CPS IgG concentrations were associated with a reduced risk of disease among infants in the seroepidemiologic study. IgG thresholds that were determined to be associated with 75 to 95% reductions in the risk of disease were 0.184 to 0.827 µg per milliliter. No GBS6-associated safety signals were observed among the mothers or infants. The incidence of adverse events and of serious adverse events were similar across the trial groups for both mothers and infants; more local reactions were observed in the groups that received GBS6 containing aluminum phosphate. Among the infants, the most common serious adverse events were minor congenital anomalies (umbilical hernia and congenital dermal melanocytosis). GBS6 induced maternal antibody responses to all serotypes, with maternal-to-infant antibody ratios of approximately 0.4 to 1.3, depending on the dose. The percentage of infants with anti-CPS IgG concentrations above 0.184 µg per milliliter varied according to serotype and formulation, with 57 to 97% of the infants having a seroresponse to the most immunogenic formulation. CONCLUSIONS: GBS6 elicited anti-CPS antibodies against group B streptococcus in pregnant women that were transferred to infants at levels associated with a reduced risk of invasive group B streptococcal disease. (Funded by Pfizer and the Bill and Melinda Gates Foundation; C1091002 ClinicalTrials.gov number, NCT03765073.).


Assuntos
Infecções Estreptocócicas , Vacinas Estreptocócicas , Streptococcus agalactiae , Feminino , Humanos , Lactente , Recém-Nascido , Gravidez , Anticorpos Antibacterianos , Imunoglobulina G , Estudos Soroepidemiológicos , Infecções Estreptocócicas/epidemiologia , Infecções Estreptocócicas/imunologia , Infecções Estreptocócicas/prevenção & controle , Vacinas Combinadas/administração & dosagem , Vacinas Combinadas/efeitos adversos , Vacinas Combinadas/imunologia , Vacinas Combinadas/uso terapêutico , Vacinas Conjugadas/administração & dosagem , Vacinas Conjugadas/efeitos adversos , Vacinas Conjugadas/imunologia , Vacinas Conjugadas/uso terapêutico , Vacinas Estreptocócicas/administração & dosagem , Vacinas Estreptocócicas/efeitos adversos , Vacinas Estreptocócicas/imunologia , Vacinas Estreptocócicas/uso terapêutico , Imunidade Materno-Adquirida/imunologia
3.
Lancet Infect Dis ; 21(2): 263-274, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-32891191

RESUMO

BACKGROUND: Group B streptococcus (GBS) is a major cause of invasive disease in young infants. Infants born to women with sufficient pre-existing anti-GBS capsular IgG antibodies are at reduced risk of GBS disease, making maternal immunisation a potential strategy for prevention. We aimed to assess the safety and immunogenicity of a novel hexavalent (serotypes Ia, Ib, II, III, IV, and V) GBS conjugate vaccine (GBS6). METHODS: This phase 1/2, placebo-controlled, observer-blinded, dose-escalation trial, was done at four clinical research centres in the USA (Kentucky, Georgia, and two sites in Utah). Healthy, non-pregnant adults aged 18-49 years were randomly assigned using an interactive, web-based response technology system. Within each dose group (low, medium, or high), participants in sentinel cohorts were randomly assigned 2:2:1 and expanded cohort participants were randomly assigned 4:4:1 to receive GBS6 with aluminium phosphate (AlPO4), GBS6 without AlPO4, or placebo (saline control). One 0·5 mL dose of either saline placebo or 5 µg capsular polysaccharide per serotype in the low-dose group, 10 µg capsular polysaccharide per serotype in the medium-dose group, or 20 µg capsular polysaccharide per serotype in the high-dose group was administered by intramuscular injection into the deltoid muscle on day 1. The primary outcome was safety up to 6 months after vaccination, including the proportion of sentinel cohort participants with clinical laboratory abnormalities at 1 week, the proportion of all participants reporting solicited local reactions, systemic events, or use of antipyretic or pain medication within 14 days, adverse events up to 1 month, and medically attended or serious adverse events up to 6 months. The secondary outcome was GBS immunogenicity (serotype-specific IgG geometric mean concentrations at 1 month). This study is registered with ClinicalTrials.gov, NCT03170609. FINDINGS: Between June 5, 2017, and June 25, 2018, 365 participants were randomly assigned and 364 (52 in each dose group) were vaccinated and included in the safety analysis. Unsolicited adverse events were reported by 15 (29%) participants in the 5 µg with AlPO4 group, 13 (25%) in the 5 µg without AlPO4 group, 22 (42%) in the 10 µg with AlPO4 group, 12 (23%) in the 10 µg without AlPO4 group, 25 (48%) in the 20 µg with AlPO4 group, 21 (40%) in the 20 µg without AlPO4 group, and 20 (38%) in the placebo group. The most common unsolicited adverse events were in the system organ class of infections and infestations in any dose or formulation of GBS6 (ranging from six [12%] in the 10 µg without AlPO4 group to 15 [29%] in the 20 µg with AlPO4 group and placebo group). Three participants reported at least one serious adverse event during the study, one each in the 5 µg GBS6 with AlPO4 group (diabetic ketoacidosis, two events; resolved), 10 µg GBS6 with AlPO4 group (died by suicide), and 20 µg GBS6 with AlPO4 group (metrorrhagia; resolved). None of these serious adverse events were considered related to the vaccine. 11 of the 365 participants were excluded from the evaluable immunogenicity population, including one participant who did not receive the vaccine, and ten who at 1 month after vaccination were withdrawn for various reasons. GBS serotype-specific IgG geometric mean concentrations increased by 1 week after vaccination for all GBS6 groups, peaked at 2 weeks, stabilised by 1 month, and declined gradually but remained higher than placebo at 6 months. INTERPRETATION: GBS6 was well tolerated in healthy adults and elicited robust immune responses for all dose levels and formulations that persisted 6 months after vaccination. This study supports further evaluation of GBS6 in pregnant women. FUNDING: Pfizer.


Assuntos
Infecções Estreptocócicas/prevenção & controle , Vacinas Estreptocócicas/imunologia , Streptococcus agalactiae , Adolescente , Adulto , Relação Dose-Resposta Imunológica , Feminino , Humanos , Masculino , Vacinas Estreptocócicas/efeitos adversos , Vacinas Combinadas , Vacinas Conjugadas , Adulto Jovem
4.
J Infect Dis ; 220(1): 105-115, 2019 06 05.
Artigo em Inglês | MEDLINE | ID: mdl-30778554

RESUMO

BACKGROUND: Group B streptococcus (GBS) causes serious diseases in newborn infants, often resulting in lifelong neurologic impairments or death. Prophylactic vaccination of pregnant women prior to delivery could provide comprehensive protection, as early onset and late-onset disease and maternal complications potentially could be addressed. METHODS: Capsular polysaccharide conjugate vaccine GBS6 was designed using surveillance data yielded by whole-genome sequencing of a global collection of recently recovered GBS isolates responsible for invasive neonatal GBS disease. Capsular polysaccharides were isolated, oxidized using sodium periodate, and conjugated to CRM197 by reductive amination in dimethyl sulfoxide. Immune responses in mice and rhesus macaques were measured in a multiplex Luminex immunoglobulin G (IgG) assay and opsonophagocytic activity assays. RESULTS: The optimized conjugates were immunogenic, alone and in combination, in mice and rhesus macaques, inducing IgG antibodies that mediated opsonophagocytic killing. Active immunization of murine dams with GBS6 prior to mating resulted in serotype-specific protection of pups from a lethal challenge with GBS. Protection following passive administration of serotype-specific IgG monoclonal antibodies to dams demonstrated conclusively that anticapsular polysaccharide IgG alone is sufficient for protection. CONCLUSIONS: The findings support the ongoing clinical evaluation of maternal GBS6 vaccination as a potential alternative method to prevent GBS disease in infants.


Assuntos
Animais Recém-Nascidos/imunologia , Imunidade Materno-Adquirida/imunologia , Polissacarídeos Bacterianos/imunologia , Infecções Estreptocócicas/imunologia , Vacinas Estreptocócicas/imunologia , Streptococcus/imunologia , Vacinas Conjugadas/imunologia , Animais , Animais Recém-Nascidos/microbiologia , Anticorpos Antibacterianos/imunologia , Feminino , Imunização/métodos , Imunoglobulina G/imunologia , Macaca mulatta/imunologia , Macaca mulatta/microbiologia , Camundongos , Sorogrupo , Infecções Estreptocócicas/microbiologia , Vacinação/métodos
5.
mSphere ; 3(4)2018 08 08.
Artigo em Inglês | MEDLINE | ID: mdl-30089644

RESUMO

This article describes the results of a study designed to bridge the World Health Organization (WHO) pneumococcal enzyme-linked immunosorbent assay (ELISA) platform to the validated Luminex-based 13-plex direct immunoassay (dLIA) platform developed by Pfizer, Inc. Both assay platforms quantify serotype-specific serum IgG antibodies (in micrograms per milliliter) against an international reference standard serum. The primary goal of this study was to determine if the dLIA is a suitable replacement for the ELISA to support clinical vaccine studies that include the evaluation of immune responses to serotypes 1, 3, 4, 5, 6A, 6B, 7F, 9V, 14, 18C, 19A, 19F, and 23F. Serum samples were selected from four pivotal 13-valent pneumococcal conjugate vaccine (13vPnC; Prevnar 13) clinical trials on the basis of their serotype-specific IgG concentrations by ELISA. In these studies, subjects were immunized either with 13vPnC or with 7-valent pneumococcal conjugate vaccine (7vPnC; Prevnar). There were 1,528 of 1,574 selected samples with sufficient remaining volume for reanalysis in the dLIA. A comparison of assay results from the dLIA and ELISA platforms showed clear and robust linear quantitative relationships across all 13 serotypes. In addition, lower IgG antibody concentrations in preimmunization samples were measured in the dLIA, thus allowing better differentiation between preimmunization and low-titer postimmunization samples. Overall, the results showed that the established population-level protective threshold IgG concentration, 0.35 µg/ml of serotype-specific serum IgG antibodies, is appropriate for use for data generated using the dLIA platform developed by Pfizer, Inc., for 10 serotypes: serotypes 1, 3, 4, 6A, 7F, 9V, 14, 18C, 19F, and 23F. On the basis of the extensive bridging analyses, however, the use of dLIA cutoff values of 0.23, 0.10, and 0.12 µg/ml is recommended for serotypes 5, 6B, and 19A, respectively. This adjustment will ensure that the consistency of the established population-level protective threshold IgG concentration is maintained when switching from the ELISA to the dLIA platform. The results of this bridging study demonstrate that the 13-plex dLIA platform is a suitable replacement for the WHO reference ELISA platform.IMPORTANCE The pneumococcal enzyme-linked immunosorbent assay (ELISA) measures IgG antibodies in human serum, and it is an important assay that supports licensure of pneumococcal vaccines. The immune correlate of protection, 0.35 µg/ml of IgG antibodies, was determined by the ELISA method. Pfizer has developed a new Luminex-based assay platform to replace the ELISA. These papers describe the important work of (i) validating the Luminex-based assay and (ii) bridging the immune correlate of protection (0.35 µg/ml IgG) to equivalent values reported by the Luminex platform.


Assuntos
Anticorpos Antibacterianos/sangue , Vacina Pneumocócica Conjugada Heptavalente/imunologia , Imunoensaio/métodos , Imunoglobulina G/sangue , Vacinas Pneumocócicas/imunologia , Polissacarídeos Bacterianos/imunologia , Streptococcus pneumoniae/imunologia , Ensaios Clínicos como Assunto , Vacina Pneumocócica Conjugada Heptavalente/administração & dosagem , Humanos , Vacinas Pneumocócicas/administração & dosagem , Soro/imunologia
6.
mSphere ; 3(4)2018 08 08.
Artigo em Inglês | MEDLINE | ID: mdl-30089645

RESUMO

A Luminex-based direct immunoassay (dLIA) platform has been developed to replace the standardized pneumococcal enzyme-linked immunosorbent assay platform. The multiplex dLIA simultaneously measures the concentration of serum immunoglobulin G (IgG) antibodies specific for pneumococcal capsular polysaccharide (PnPS) serotypes 1, 3, 4, 5, 6A, 6B, 7F, 9V, 14, 18C, 19A, 19F, and 23F. The assay uses poly-l-lysine (PLL)-conjugated PnPS, chemically coupled to spectrally distinct Luminex microspheres. Assay validation experiments were performed using residual human serum samples obtained from 13-valent pneumococcal conjugate vaccine (13vPnC) clinical studies. Assay results are expressed as IgG antibody concentrations in micrograms per milliliter using the international reference serum, 007sp. The lower limit of quantitation (LLOQ) for all serotypes covered in the 13-plex dLIA fell within the range of 0.002 to 0.038 µg/ml serum IgG. The difference between the lower limit and upper limit of the assay range was >500-fold for all serotypes, and assay variability was <20% relative standard deviation (RSD) for all serotypes. IgG antibody measurements were shown to be serotype-specific (some cross-reactivity was observed only between the structurally related serotypes 6A and 6B as well as 19A and 19F), and no interference was observed between the serotypes when the assay was performed in the 13-plex format compared to the singleplex assays. The 13-plex dLIA platform developed by Pfizer Inc. generates up to 143 test results in a single 96-well plate and is a suitable replacement of the enzyme-linked immunosorbent assay (ELISA) platform for evaluating vaccine clinical trials.IMPORTANCE The pneumococcal enzyme-linked immunosorbent assay (ELISA) measures IgG antibodies in human serum, and it is an important assay that supports licensure of pneumococcal vaccines. The immune correlate of protection, 0.35 µg/ml of IgG antibodies, was determined by the ELISA method. Pfizer has developed a new Luminex-based assay platform to replace the ELISA. These papers describe the important work of (i) validating the Luminex-based assay and (ii) bridging the immune correlate of protection (0.35 µg/ml IgG) to equivalent values reported by the Luminex platform.


Assuntos
Anticorpos Antibacterianos/sangue , Imunoensaio/métodos , Imunoglobulina G/sangue , Polissacarídeos Bacterianos/imunologia , Streptococcus pneumoniae/imunologia , Reações Cruzadas , Humanos , Vacinas Pneumocócicas/administração & dosagem , Vacinas Pneumocócicas/imunologia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Soro/imunologia
7.
PLoS One ; 10(2): e0116945, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25719409

RESUMO

Staphylococcus aureus is a versatile pathogen of medical significance, using multiple virulence factors to cause disease. A prophylactic S. aureus 4-antigen (SA4Ag) vaccine comprising capsular polysaccharide (types 5 and 8) conjugates, clumping factor A (ClfA) and manganese transporter C (MntC) is under development. This study was designed to characterize S. aureus isolates recovered from infected patients and also to investigate approaches for examining expression of S. aureus vaccine candidates and the host response during human infection. Confirmation of antigen expression in different disease states is important to support the inclusion of these antigens in a prophylactic vaccine. Hospitalized patients with diagnosed S. aureus wound (27) or bloodstream (24) infections were enrolled. Invasive and nasal carriage S. aureus isolates were recovered and characterized for genotypic diversity. S. aureus antigen expression was evaluated directly by real-time, quantitative, reverse-transcriptase PCR (qRT-PCR) analysis and indirectly by serology using a competitive Luminex immunoassay. Study isolates were genotypically diverse and all had the genes encoding the antigens present in the SA4Ag vaccine. S. aureus nasal carriage was detected in 55% of patients, and in those subjects 64% of the carriage isolates matched the invasive strain. In swab samples with detectable S. aureus triosephosphate isomerase housekeeping gene expression, RNA transcripts encoding the S. aureus virulence factors ClfA, MntC, and capsule polysaccharide were detected by qRT-PCR. Antigen expression was indirectly confirmed by increases in antibody titer during the course of infection from acute to convalescent phase. Demonstration of bacterial transcript expression together with immunological response to the SA4Ag antigens in a clinically relevant patient population provides support for inclusion of these antigens in a prophylactic vaccine.


Assuntos
Sorogrupo , Infecções Estafilocócicas/microbiologia , Staphylococcus aureus/imunologia , Fatores de Virulência/genética , Adulto , Idoso , Idoso de 80 Anos ou mais , Cápsulas Bacterianas/imunologia , Coagulase/genética , Coagulase/imunologia , Coagulase/metabolismo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Mucosa Nasal/microbiologia , Vacinas Antiestafilocócicas/imunologia , Staphylococcus aureus/genética , Staphylococcus aureus/patogenicidade , Fatores de Virulência/imunologia , Fatores de Virulência/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA