1.
Phys Med ; 123: 103415, 2024 Jun 19.
Artigo em Inglês | MEDLINE | ID: mdl-38901143

RESUMO

PURPOSE: Employing a Fresnel lens and a point-like light source to create a convergent light beam for the camera effectively minimizes stray light and enhances image quality in optical computed tomography (OCT), benefiting 3D dosimetry applications. This study outlines the development of an economical cone-beam optical computed scanner for 3D dosimetry. METHODS: Optical performance was assessed by calculating modulation transfer function (MTF) with pattern charts. Stray light was evaluated by imaging a cylinder flask and a square grid with 5 mm diameter holes to determine the stray-to-primary ratio. Reconstruction quality was determined using SIRT-TV and compared with spectrophotometry attenuation coefficients, with the best regularization parameter (λ = 0.01) chosen based on contrast-to-noise ratio (CNR). Dosimetry performance was assessed by determining percentage dose depth (PDD) for a 6MV beam with a 5 × 5 cm2 field using FXO-f gel dosimeter, compared with ionization chamber data. RESULTS: MTF evaluation yielded ≥ 50 % agreement with pattern charts. Stray-to-primary ratio was less than 0.1 or 10 % of the total signal. Reconstruction showed low noise and artifacts, with optimal CNR at λ = 0.01. Attenuation coefficients from optical CT aligned with spectrometer measurements within 1.2 %. PDD calculated with FXO-f gel dosimeter closely matched ionization chamber data (<1.2 % difference), achieving a dose resolution of 0.1 Gy. CONCLUSION: The built and optimization the de optical-CT based on a convergent beam is read to perform the 3D quality assurance in clinical applications.

2.
Phys Med Biol ; 68(22)2023 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-37852274

RESUMO

Metallic nanoparticles, such as gold (Au, Z = 79) and silver (Ag, Z = 47) nanoparticles (AuNPs and AgNPs, respectively), possess strong surface plasmonic resonance (SPR) and high atomic number, which makes them ideal candidates for enhancing dosimeter sensitivity. In this study, we have inserted different mass percentages (from 0 to 0.015 wt%) of AuNPs into a gelatinous Fricke-xylenol-orange (FXO-f) gel matrix and irradiated it with doses ranging from 2 to 32 Gy, using a source of x-ray of low energy with an effective energy of 42 keV. Optical absorption increased significantly; sensitivity gains of up to 50% were achieved for the FXO-f gel matrix containing 0.011 wt% AuNPs. To elucidate the mechanism underlying this increased sensitivity, we also evaluated FXO-f gel matrixes containing AgNPs. AgNPs insertion into the FXO-f gel matrix did not enhance sensitivity, which suggested that the AgNPs plasmonic absorption band and the FXO-f gel matrix absorption band at 441 nm overlapped, to increase absorption even after the gel matrix was irradiated. To visualize the dose distribution, we recorded optical tomography and acquired 3D reconstruction maps. In addition, we analyzed the dose enhancement factor (DEF) by using magnetic resonance images. AuNPs insertion into the FXO-f gel matrix resulted in a DEF gain of 1.37, associated with the photoelectric effect originating from the increased number of free radicals.


Assuntos
Ouro , Nanopartículas Metálicas , Radiometria/métodos , Imageamento por Ressonância Magnética
3.
Clin Oncol (R Coll Radiol) ; 35(9): 611-620, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37365062

RESUMO

AIMS: Reports of stereotactic arrhythmia radioablation (STAR) in patients with refractory ventricular tachycardia after catheter ablation are limited to small series. Here, we carried out a systematic review and meta-analysis of studies to better determine the efficacy and toxicity of STAR for ventricular tachycardia. MATERIALS AND METHODS: Following the Preferred Reporting Items for Systematic Reviews and Meta-analysis (PRISMA) and the Meta-analyses Of Observational Studies in Epidemiology (MOOSE) guidelines, eligible studies were identified on Medline, Embase, Cochrane Library and the proceedings of annual meetings to 10 February 2023. Efficacy was defined as a ventricular tachycardia burden reduction >70% at 6 months; safety was defined as <10% of any grade ≥3 toxicity. RESULTS: Seven observational studies with a total of 61 patients treated were included. At 6 months, the ventricular tachycardia burden reduction was 92% (95% confidence interval 85-100%) and use of fewer than two anti-arrhythmic drugs was seen in 85% (95% confidence interval 50-100). Six months after STAR, an 86% reduction (95% confidence interval 80-93) in the number of implantable cardioverter-defibrillator shocks was observed. The rates for improved, unchanged and decreased cardiac ejection fraction were 10%, 84% and 6%, respectively. Overall survival at 6 and 12 months was 89% (95% confidence interval 81-97) and 82% (95% confidence interval 65-98). The cardiac-specific survival at 6 months was 87%. Late grade 3 toxicity occurred in 2% (95% confidence interval 0-5%) with no grade 4-5 toxicity. CONCLUSION: STAR demonstrated both satisfactory efficacy and safety for the management of refractory ventricular tachycardia and was also associated with a significant decline in anti-arrhythmic drugs consumption. These findings support the continued development of STAR as a treatment option.


Assuntos
Ablação por Cateter , Desfibriladores Implantáveis , Taquicardia Ventricular , Humanos , Antiarrítmicos/uso terapêutico , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/radioterapia , Taquicardia Ventricular/cirurgia , Coração , Ablação por Cateter/efeitos adversos , Resultado do Tratamento
4.
Acta Trop ; 190: 395-402, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30552880

RESUMO

Arboviruses have become a major public health concern in Brazil, especially after Zika virus (ZIKV) and Chikungunya virus (CHIKV) introduction, leading to massive epidemics. We conducted an investigation of arboviruses in patients with acute febrile illness for less than five days in Mato Grosso state (MT) during the period of ZIKV and CHIKV dissemination in Brazil. To achieve that, 453 human serum samples of patients suspected of Dengue (DENV), Yellow Fever (YFV), ZIKV or CHIKV collected in health units of 31 cities of MT were subjected to RT-PCR protocols for 10 flaviviruses, 5 alphaviruses and orthobunyaviruses from Simbu serogroup, nucleotide sequencing and viral isolation. Regarding flaviviruses, five (1.1%) patients were infected with DENV-1 genotype V, 22 (4.4%) with DENV-4 genotype II, 3 (0.7%) with YFV South American genotype II and five (1.1%) with ZIKV Asian genotype. The first human case of ZIKV in MT was detected in this study during August, 2015 in Tapurah. Alphaviruses were detected in 2 (0.4%) patients infected with CHIKV genotype ECSA, 1 (0.2%) with Madariaga (EEEV) lineage III and 34 (7.5%) with Mayaro (MAYV) genotype L. Four (11.4%) patients presented dual infections with DENV-1/ZIKV, DENV-1/DENV4, DENV-4/MAYV and ZIKV/MAYV. The majority - 13/34 positive for MAYV, one for Madariaga virus - are residents in Várzea Grande (VG), metropolitan region of Cuiabá, capital of MT. The first CHIKV infection in MT was detected in this study in Mirassol D'Oeste, during July, 2015. In addition, 20 (4.4%) patients were positive for OROV Segment S genotype IA. These results reinforce the variation in arboviruses frequency and distribution during outbreaks, highlinghing the importance of differential diagnosis to identify agents silently co-circulating with major health problem arboviruses.


Assuntos
Arbovírus/genética , Arbovírus/isolamento & purificação , Febre de Chikungunya/epidemiologia , Dengue/epidemiologia , Febre/virologia , Infecção por Zika virus/epidemiologia , Adolescente , Adulto , Brasil/epidemiologia , Febre de Chikungunya/virologia , Vírus Chikungunya/genética , Vírus Chikungunya/isolamento & purificação , Criança , Pré-Escolar , Coinfecção/epidemiologia , Coinfecção/virologia , Dengue/virologia , Vírus da Dengue/genética , Vírus da Dengue/isolamento & purificação , Feminino , Genótipo , Humanos , Masculino , Pessoa de Meia-Idade , Febre Amarela/epidemiologia , Febre Amarela/virologia , Vírus da Febre Amarela/genética , Vírus da Febre Amarela/isolamento & purificação , Adulto Jovem , Zika virus/genética , Zika virus/isolamento & purificação , Infecção por Zika virus/virologia
5.
Braz J Med Biol Res ; 50(3): e5848, 2017 Mar 02.
Artigo em Inglês | MEDLINE | ID: mdl-28273210

RESUMO

This study presents the characterization of an X-ray irradiator through dosimetric tests, which confirms the actual dose rate that small animals and cells will be exposed to during radiobiological experiments. We evaluated the linearity, consistency, repeatability, and dose distribution in the positions in which the animals or cells are placed during irradiation. In addition, we evaluated the performance of the X-ray tube (voltage and tube operating current), the radiometric survey (leakage radiation) and safety devices. The irradiator default setting was established as 160 kV and 25 mA. Tests showed that the dose rate was linear overtime (R2=1) and remained stable for long (constant) and short (repeatability) intervals between readings. The mean dose rate inside the animal cages was 1.27±0.06 Gy/min with a uniform beam of 95.40% (above the minimum threshold guaranteed by the manufacturer). The mean dose rate inside the cell plates was 0.92±0.19 Gy/min. The dose rate dependence with tube voltage and current presented a quadratic and linear relationship, respectively. There was no observed mechanical failure during evaluation of the irradiator safety devices and the radiometric survey obtained a maximum ambient equivalent dose rate of 0.26 mSv/h, which exempts it from the radiological protection requirements of the International Atomic Energy Agency. The irradiator characterization enables us to perform radiobiological experiments, and assists or even replaces traditional therapy equipment (e.g., linear accelerators) for cells and small animal irradiation, especially in early research stages.


Assuntos
Doses de Radiação , Radiometria/instrumentação , Animais , Calibragem , Desenho de Equipamento , Aceleradores de Partículas , Radiometria/métodos , Raios X
6.
Phys Med ; 34: 1-6, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28108100

RESUMO

Intensity modulated radiotherapy (IMRT) is one of the most modern radiation therapy treatment techniques. Although IMRT can deliver high and complex conformational doses to the tumor volume, its implementation requires rigorous quality assurance (QA) procedures that include a dosimetric pre-treatment verification of individual patient planning. This verification usually involves measuring a small volume of absolute dose with an ionization chamber and checking bi-dimensional fluency with an array of detectors. The planning technique has tri-dimensional characteristics, but no tridimensional dosimetry has been established in the clinical routine. One strategy to perform three-dimensional dosimetry is to use polymeric gels associated with magnetic resonance imaging to evaluate dose distribution. Here, we have compared the results of conventional QA procedures involving one- and two-dimensional dosimetry to the results of three-dimensional dosimetry conducted with MAGIC-f gel in 10 cases of prostate cancer IMRT planning. More specifically, we used the gamma index (3%/3mm) to compare the results of three-dimensional dosimetry to the expected dose distributions obtained with the treatment planning system. Except for one IMRT treatment plan, the gel dosimetry results agreed with the conventional quality control and provided an overview of dose distribution in the target volume.


Assuntos
Imageamento Tridimensional , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Garantia da Qualidade dos Cuidados de Saúde , Radioterapia de Intensidade Modulada , Calibragem , Géis , Humanos , Imageamento por Ressonância Magnética , Masculino , Radiometria , Planejamento da Radioterapia Assistida por Computador
7.
Med Phys ; 39(5): 2877-84, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22559660

RESUMO

PURPOSE: This paper presents the application of MAGIC-f gel in a three-dimensional dose distribution measurement and its ability to accurately measure the dose distribution from a tomotherapy unit. METHODS: A prostate intensity-modulated radiation therapy (IMRT) irradiation was simulated in the gel phantom and the treatment was delivered by a TomoTherapy equipment. Dose distribution was evaluated by the R2 distribution measured in magnetic resonance imaging. RESULTS: A high similarity was found by overlapping of isodoses of the dose distribution measured with the gel and expected by the treatment planning system (TPS). Another analysis was done by comparing the relative absorbed dose profiles in the measured and in the expected dose distributions extracted along indicated lines of the volume and the results were also in agreement. The gamma index analysis was also applied to the data and a high pass rate was achieved (88.4% for analysis using 3%∕3 mm and of 96.5% using 4%∕4 mm). The real three-dimensional analysis compared the dose-volume histograms measured for the planning volumes and expected by the treatment planning, being the results also in good agreement by the overlapping of the curves. CONCLUSIONS: These results show that MAGIC-f gel is a promise for tridimensional dose distribution measurements.


Assuntos
Polímeros/química , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Animais , Géis , Humanos , Masculino , Neoplasias da Próstata/radioterapia , Radiometria , Software
10.
Appl Microbiol ; 18(6): 965-71, 1969 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-5370666

RESUMO

The feasibility of removing algae from water and wastewater by chemical flocculation techniques was investigated. Mixed cultures of algae were obtained from both continuous- and batch-fed laboratory reactors. Representative cationic, anionic, and nonionic synthetic organic polyelectrolytes were used as flocculants. Under the experimental conditions, chemically induced algal flocculation occurred with the addition of cationic polyelectrolyte, but not with anionic or nonionic polymers, although attachment of all polyelectrolyte species to the algal surface is shown. The mechanism of chemically induced algal flocculation is interpreted in terms of bridging phenomena between the discrete algal cells and the linearly extended polymer chains, forming a three-dimensional matrix that is capable of subsiding under quiescent conditions. The degree of flocculation is shown to be a direct function of the extent of polymer coverage of the active sites on the algal surface, although to induce flocculation by this method requires that the algal surface charge must concurrently be reduced to a level at which the extended polymers can bridge the minimal distance of separation imposed by electrostatic repulsion. The influence of pH, algal concentration, and algal growth phase on the requisite cationic flocculant dose is also reported.


Assuntos
Eucariotos , Polímeros , Microbiologia da Água , Amidas , Aminas , Fenômenos Químicos , Físico-Química , Concentração de Íons de Hidrogênio , Poliestirenos , Abastecimento de Água
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA