Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 75
Filtrar
1.
Int Dent J ; 2024 Feb 29.
Artigo em Inglês | MEDLINE | ID: mdl-38429145

RESUMO

OBJECTIVE: The aim of this scoping review was to explore and synthesise the current evidence on the antimicrobial activity of antibacterial suture materials used in oral surgery. METHODS: The review was conducted following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) Extension for Scoping Reviews. A bibliographic search was carried out in the PubMed and Scopus databases to retrieve all human clinical studies that investigated the antimicrobial efficacy of antibacterial-coated sutures used in oral surgery. Included studies were screened and extracted independently by 2 examiners. Data were tabulated and qualitatively described. RESULTS: The search initially returned 150 articles and resulted in 5 included studies after the duplicates' removal and the full-text screening. Selected studies were published from 2014 to 2019. Three studies (60%) were randomised clinical trials, whilst the remaining studies did not report information on randomisation. The antimicrobial agents for coated sutures included triclosan and chlorhexidine. In almost all the studies, antibacterial-coated sutures exhibited lower bacterial retention compared to those without coating. CONCLUSIONS: Within limitations, the antimicrobial-coated sutures employed in oral surgery exhibited good results in terms of their microbicidal activity when compared with sutures that were not coated. Considering the high variability and confounding factors identified in the included studies, more high-quality research is needed to confirm these results. Antimicrobial-coated sutures could represent a promising and clinically valid strategy to reduce microbial colonisation in oral surgery. The reduced bacterial adherence is likely to improve the clinical success of the surgical procedures. Yet, the cost-benefit ratio of antimicrobial-coated sutures should be assessed in larger clinical trials to confirm their efficacy over conventional noncoated sutures.

2.
Clin Oral Investig ; 28(4): 213, 2024 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-38480533

RESUMO

OBJECTIVE: The limitations of spontaneous bone healing underscore the necessity for exploring alternative strategies to enhance bone regeneration in maxillary radicular cyst cases. This retrospective study aimed to assess the impact of a bone substitute material (i.e., Bio-Oss) on bone volume regeneration following maxillary radicular cyst enucleation using cone-beam computed tomography (CBCT). MATERIALS AND METHODS: Seventy-three patients with maxillary radicular cysts were divided into two groups: one undergoing guided bone regeneration (GBR) with Bio-Oss and absorbable collagen membrane (n = 35), and the other receiving cyst excision alone (n = 38). Volumetric measurements using Amira software on CBCT scans evaluated bone regeneration, with cystic lesion shrinkage rates calculated. Intergroup comparisons utilized independent sample t-tests (P < 0.05), and linear regression analysis assessed the influence of preoperative cyst volume and group on bone healing. RESULTS: Both groups showed similar success rates in bone formation at the 12-month follow-up, with no significant differences between them (mean (SD), control: 75.16 (19.17) vs. GBR: 82 (20.22), P > 0.05). Linear regression analysis revealed a negative correlation between preoperative cyst volume and bone regeneration in both groups (P < 0.05). CONCLUSION: Bio-Oss may not significantly enhance bone augmentation in maxillary radicular cysts. In addition, preoperative cyst volume negatively affected the shrinkage rate of cystic lesions. CLINICAL RELEVANCE: Clinicians should consider patient-specific factors such as anatomy and lesion size when determining the need for bone substitute materials. Future research could focus on optimizing treatment protocols and alternative regenerative strategies to improve patient outcomes in maxillary cyst cases.


Assuntos
Substitutos Ósseos , Minerais , Cisto Radicular , Humanos , Transplante Ósseo/métodos , Estudos Retrospectivos , Cisto Radicular/cirurgia , Substitutos Ósseos/uso terapêutico , Regeneração Óssea
3.
Clin Oral Investig ; 28(4): 218, 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38489136

RESUMO

OBJECTIVES: This study aimed to compare the impact of pre- and postoperative etoricoxib administration versus only postoperative on third molar extraction sequelae and oral health quality of life. MATERIALS AND METHODS: This prospective quasi experimental study involved 56 patients, divided into a study group receiving preemptive etoricoxib 120 mg before surgery and postoperative etoricoxib 120 mg (n = 28), and a control group receiving preemptive placebo before surgery and postoperative etoricoxib 120 mg (n = 28). Follow-up assessments were conducted at 3- and 7-days post-surgery, recording swelling, trismus, and adverse events. Patients rated perceived pain using the visual analog scale (VAS) and completed an oral health-related quality of life (OHRQoL) questionnaire at specified intervals. Statistical analysis employed non-parametric tests (i.e., the Mann-Whitney test, Friedman test, and Wilcoxon sign test) with P < 0.05. RESULTS: Significantly lower VAS scores were reported in the study group throughout the follow-up period (P < 0.05). Pharmacological protocol did not have a significant impact on postoperative edema and trismus (P > 0.05). However, double etoricoxib intake significantly improved postoperative quality of life on day 3 after surgery (P < 0.05). CONCLUSIONS: Pre- and postoperative etoricoxib 120 mg intake in third molar surgery reduced postoperative pain and enhanced postoperative quality of life on day 3 after surgery. Importantly, it was equally effective in managing swelling and trismus compared to exclusive postoperative intake. CLINICAL RELEVANCE: Preemptive etoricoxib use may decrease patient discomfort following impacted mandibular third molar extraction.


Assuntos
Dente Serotino , Dente Impactado , Humanos , Etoricoxib/uso terapêutico , Dente Serotino/cirurgia , Trismo/prevenção & controle , Trismo/etiologia , Qualidade de Vida , Estudos Prospectivos , Saúde Bucal , Extração Dentária/efeitos adversos , Dor Pós-Operatória/tratamento farmacológico , Dor Pós-Operatória/prevenção & controle , Dente Impactado/cirurgia , Edema/etiologia
4.
J Dent ; 142: 104865, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38311017

RESUMO

OBJECTIVES: To evaluate the fracture strength and linear elongation at break of three-units fixed partial dentures (FPDs) fabricated with traditional and new materials for fixed prosthodontics before and after ageing. METHODS: Sixty models of three-units FPDs were fabricated and cemented onto a Co-Cr model simulating the replacement of a maxillary second premolar. The samples were randomly divided into 3 groups: metal-ceramic (MCR), graphene-doped polymethylmethacrylate (PMMA-GR) and polymethylmethacrylate (PMMA). Half of the samples were directly subjected to fracture test, while the remaining half underwent an ageing process and then a fracture loading test using an electrodynamic testing machine. Fracture load and elongation at break values were taken and statistically analysed. RESULTS: Significant differences were detected between the different materials (p<0.05). All groups showed a reduction of the fracture load and elongation at break values after ageing, but not statistically significant, except for PMMA group (p = 2.012e-19) (p = 3.8e-11). CONCLUSIONS: MCR and PMMA-GR three-units FPDs showed higher fracture strength and lower elongation at break compared to PMMA. MCR and PMMA-GR had higher resistance to ageing processes compared to PMMA. CLINICAL SIGNIFICANCE: PMMA-GR could be considered a material for long-term provisional restorations as its mechanical behaviour and ageing resistance are more like MCR than PMMA.


Assuntos
Resistência à Flexão , Grafite , Polimetil Metacrilato , Teste de Materiais , Cerâmica , Prótese Parcial Fixa , Falha de Restauração Dentária , Análise do Estresse Dentário , Porcelana Dentária
5.
J Craniofac Surg ; 2024 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-38315758

RESUMO

This experimental anatomic study aimed to investigate the correlations between the mesio-vestibular canal (MB1) and the second mesio-vestibular canal (MB2) of the mesio-vestibular root of the upper sexts using cone-beam computed tomography (CBCT) imaging. A total of 24 extracted maxillary first molars were collected and subjected to CBCT imaging. The presence, location, and morphology of MB1 and MB2 canals were evaluated using axial, coronal, and sagittal CBCT sections. The interrelation between MB1 and MB2 canals was assessed, including their separate canals, merging, and division points. Among the 24 maxillary first molars examined, 86.5% demonstrated the presence of an MB2 canal in addition to MB1. The MB2 and MB1 were confluent in 80% of the cases with a confluent height of 4,16 mm. The mean distance between MB1 and MB2 canals was 1.85 mm. This study provides detailed information on the anatomic correlations between MB1 and MB2 canals of the mesio-vestibular root in the upper sexts using CBCT imaging. The high prevalence of MB2 canals suggests their significance in endodontic procedures and emphasizes the importance of thorough exploration and identification during root canal treatment. The knowledge of the location and morphology of these canals can aid in successful endodontic therapy and enhance treatment outcomes.

6.
JMIR Res Protoc ; 13: e53222, 2024 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-38393754

RESUMO

BACKGROUND: Although the detrimental effects of conventional combustible cigarettes on oral health and dental esthetics are well known, there is limited information about the long-term impact of combustion-free nicotine alternatives (C-F NA) such as e-cigarettes or heated tobacco products. OBJECTIVE: This multicenter, prospective, 3-parallel-arm randomized controlled trial will investigate whether switching from combustible cigarettes to C-F NA will lead to measurable improvements in oral health parameters and dental esthetics over 18 months in adult smokers with limited gum disease. METHODS: Regular smokers not intending to quit and without clinical signs of periodontitis will be randomly assigned (1:4 ratio) to either standard of care with brief cessation advice (control group; arm A) or C-F NA use (intervention group; arm B). The study will also include a reference group of never smokers (reference group; arm C). The primary end point is the change in the Modified Gingival Index (MGI) score from baseline between the control arm (arm A) and the intervention arm (arm B) at the 18-month follow-up. In addition, the study will analyze the within- and between-group (arms A, B, and C) changes in MGI assessment, plaque imaging, dental shade quantitation, tooth stain scores, and oral health-related quality of life questionnaires measured at each study time point. All participants will attend a total of 7 clinic visits: screening, enrollment, and randomization (visit 0); baseline visit-day 14 (visit 1); day 90 (visit 2); day 180 (visit 3); day 360 (visit 4); and day 540 (visit 5). This multicenter study will be conducted in 4 dental clinics in 4 countries. The statistical analysis will involve descriptive statistics for continuous and categorical data. Primary end points will undergo tests for normality and, based on distribution, either a 2-sided t test or Mann-Whitney U test. Linear mixed model with random factors center and study arms by center will also be applied. Secondary end points, including MGI assessment and quality of life, will be subjected to similar tests and comparisons. Only if one value of the parameter MGI is missing after day 1, the last available observation will be carried forward. The analysis will be performed on the substituted data. Secondary parameters will not have missing value replacement. RESULTS: Participant recruitment began in October 2021, and enrollment was completed in June 2023. Results will be reported in 2025. CONCLUSIONS: This will be the first study to provide key insights into oral health benefits or risks associated with using C-F NA in smokers who are seeking alternatives to cigarette smoking. TRIAL REGISTRATION: ClinicalTrials.gov NCT04649645; https://clinicaltrials.gov/ct2/show/NCT04649645. INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): DERR1-10.2196/53222.

7.
Int Dent J ; 2024 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-38350803

RESUMO

OBJECTIVE: This is the first study evaluating the impact of different pecking motion depths on dynamic cyclic fatigue resistance of different endodontic instruments. METHODS: Four nickel-titanium systems (Hyflex EDM OneFile 25/. ∼; Rotate 25/0.6; Mtwo 25/0.6; Reciproc Blue R25) were tested. Forty instruments from each group were subjected to 4 different pecking movements to evaluate their cyclic fatigue resistance. The distances for the pecking motion were 3-mm forward and backward, 1-mm (3-mm forward and 2-mm backward), 2-mm (4-mm forward and 2-mm backward), and 3-mm (5-mm forward and 2-mm backward). Speeds were 100 and 200 mm/min for the descending and ascending motion, respectively. The times to fracture (TtF) in seconds were recorded for each instrument. Data were statistically analysed by using 2-way ANOVA and Bonferroni multiple comparison post hoc test (P < .05). RESULTS: All instruments had a significant increase in cyclic fatigue resistance during the forward dynamic motion compared with the axial continuous. Overall, the heat-treated instruments reported higher fatigue strength than the untreated files (P < .05). Reciproc Blue and Hyflex EDM showed higher TtF in the forward movements of 1-/2-mm and 2-mm (P < .05), respectively while Mtwo 25.06 and Rotate 25.06 in the forward movement of 3-mm (P < .05). CONCLUSIONS: Within the limits of this in vitro study, the pecking motion depths had varying impacts on the cyclic fatigue resistance of instruments. Reciproc Blue and Hyflex EDM performed significantly better with pecking motions of 1-and 2-mm. Improving endodontic instrument durability through specific pecking depths has the potential for improving clinical performance and reducing instrument failures.

8.
Odontology ; 112(1): 158-168, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37173534

RESUMO

Detachment is the major cause of failure of endodontic fibre posts. Hollow posts have been recently introduced to overcome such issue. The primary aim of this pilot study was to compare the push-out bond strength of hollow posts and traditional solid posts. Eight round-shaped single-canal premolars extracted for periodontal reason were selected as sample and equally randomized into two groups: (i) traditional solid fibre posts-TECH21xop and ii) hollow fibre posts-TECHOLE. A dual-curing self-adhesive cement (new TECHCEM) was used for posts placement. Six horizontal sections-two from each portion of the root (coronal, middle and apical)-were obtained from each sample root, yielding a total of 24 sections for each group. Push-out test was performed on the sections and bond strength values were compared between groups and within each group. Scanning electron microscope (SEM) fractographical analysis was conducted on each section. Additional SEM and EDX analyses were performed on new samples of both posts, to assess fibres density and distribution, and the chemical composition of the fibres and the matrix. Hollow posts showed a significantly higher push-out bond strength (6.36 ± 1.22 MPa) than solid posts (3.64 ± 1.62 MPa). Among the three root portions of the same group, there was no significant difference in bond strength. In both groups, the most frequent type of fracture was a mixed adhesive failure with the cement covering 0 to 50% of the post perimeter. Hollow post fibres appear more similar in size and have a more homogeneous distribution, compared to solid posts. The two post types also have different chemical compositions.


Assuntos
Colagem Dentária , Técnica para Retentor Intrarradicular , Cimentos de Resina/química , Projetos Piloto , Teste de Materiais , Análise do Estresse Dentário , Dentina , Vidro
9.
Odontology ; 112(1): 1-18, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37433927

RESUMO

This scoping review aimed to synthesize and explore the current boundaries and limitations of laboratory research on the effectiveness of continuous chelation irrigation protocol in endodontics. This scoping review was reported according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) Extension for Scoping Reviews. Literature search was conducted on Pubmed and Scopus to identify all laboratory studies evaluating smear layer and hard-tissue debris removal or, antimicrobial efficacy, or dentine erosion induced by continuous chelation. Two independent reviewers performed the all review steps and the relevant items were recorded. Seventy-seven potentially relevant studies were identified. Finally, 23 laboratory studies met the eligibility criteria for qualitative synthesis. Seven studies focused on the smear layer/debris removal outcome, 10 on antimicrobial activity, and 10 on dentine erosion. In general, the continuous chelation protocol was equally or more effective in the cleanliness of root canals and antimicrobial activity compared with traditional sequential protocol. In addition, etidronate solutions seemed to be milder chelating agents compared to those with EDTA, thus resulting in reduced or no dentine erosion and roughness modification. Yet, the methodological differences among the included studies limit the results' generalizability. The continuous chelation seems to be equally or more effective in all investigated outcomes when compared with the traditional sequential protocol. The methodological variability among the studies and shortcomings in the methods employed limit the generalizability and clinical relevance of the results. Standardized laboratory conditions combined with reliable three-dimensional investigation approaches are necessary to obtain clinically informative findings.


Assuntos
Anti-Infecciosos , Camada de Esfregaço , Humanos , Quelantes/farmacologia , Anti-Infecciosos/farmacologia , Assistência Odontológica , Revisões Sistemáticas como Assunto
10.
Clin Exp Dent Res ; 10(1): e811, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38053521

RESUMO

OBJECTIVES: The aim of this study is to determine the cyclic fatigue resistance of Mtwo Minimal in static and dynamic tests, with different amplitudes of pecking movements, at intracanal temperature. MATERIALS AND METHODS: Two hundred new 25-mm Mtwo Minimal rotary files (#10/0.035, #17.5/0.045, #25/0.05, #40/0.03, #45/0.03) were tested in static and dynamic cyclic fatigue tests at 35°C (±1°C). An artificial stainless-steel canal was used. In the dynamic mode, axial movements were set at 1 and 3 mm. The number of cycles to fracture (NCF) was recorded and statistically analyzed by one-way analysis of variance (p < 0.05). RESULTS: The 3-mm dynamic test showed significantly increased NCF than the other tests for the #10/0.035, #17.5/0.045, and #25/0.05 files (p < 0.05). The #40/0.03 and #45/0.03 files showed no significant differences in all the tests (p > 0.05). CONCLUSION: Mtwo Minimal showed higher cyclic fatigue resistance in the dynamic test than the static test, except for the larger instruments. The 3-mm pecking amplitude increased the cyclic fatigue resistance of the smaller instruments.


Assuntos
Níquel , Titânio , Ligas
11.
J Dent ; 139: 104772, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37939996

RESUMO

OBJECTIVES: To determine the validity and reliability of novel digitalized tools for dental plaque detection and explore the benefits and limitations connected to their use. DATA: Reporting followed the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) Extension for Scoping Reviews. All human clinical studies comparing dental plaque detection using digitalized systems against a standard reference were included. SOURCES: PubMed and Scopus were screened from 01 January 2013 to 28 September 2023. Bibliographies of primary studies and principal peer-reviewed scientific journals were manually searched. STUDY SELECTION: The initial search identified 576 articles, with a total of 13 included in the review, published between 2015 and 2023. Most of the studies included (77 %) were cross-sectional with three being prospective. Digital devices captured 2D and 3D images via cameras and intra-oral scanners, respectively. The Turesky's modified plaque index was the most frequent clinical index. Correlation with clinical examination was moderate to strong, with good to excellent intra- and inter-system agreement. CONCLUSIONS: Within the limitations of this scoping review, image analysis-based plaque detection systems demonstrated good correlations with clinical plaque indices, using both 2D and 3D imaging systems. Whilst digital plaque detection devices offer advantages in terms of procedural standardization and reproducibility, they also have limitations, therefore currently, their application should be underpinned by a comprehensive clinical examination. CLINICAL SIGNIFICANCE: Digital plaque detection tools, that provide standardized measurements and store acquired images, facilitate more informed feedback to patients. This objective analysis may enhance clinician confidence in their utility for clinical trials and other applications.


Assuntos
Placa Dentária , Humanos , Reprodutibilidade dos Testes , Placa Dentária/diagnóstico , Estudos Prospectivos , Índice de Placa Dentária , Imageamento Tridimensional
12.
Aust Endod J ; 49(3): 623-630, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37667824

RESUMO

The aim of the study was to evaluate the impact of kinematics and irrigation protocols on the extrusion of apical debris during removal of different obturation techniques. A total of 144 single-rooted teeth were instrumented and obturated with Thermafil+AH Plus, Thermafil+AH Plus Bioceramic and single gutta-percha cone+AH Plus Bioceramic. Samples were divided according to the retreatment kinematics: continuous rotation or Jeni motion. Each sub-group was subjected to conventional irrigation or irrigation activated by EDDY. Extruded debris was collected in Eppendorf tubes, weighted and retreatment time was digitally recorded. Data were analysed with two-way ANOVA (p < 0.05). Debris extrusion was not significantly different between all groups. EDDY activation system and CanalPro Jeni required significantly longer time compared with other groups to remove Thermafil+AH Plus and single cone+AH Plus Bioceramic. Within current limitations, obturation technique, irrigation protocol and kinematics tested had no influence on apical extrusion debris, while they significantly impacted the retreatment time.


Assuntos
Guta-Percha , Materiais Restauradores do Canal Radicular , Preparo de Canal Radicular/métodos , Obturação do Canal Radicular/métodos , Fenômenos Biomecânicos , Cavidade Pulpar , Retratamento
13.
Aust Endod J ; 49(3): 592-598, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37592880

RESUMO

The aim of this study was to compare the cyclic fatigue resistance of nickel-titanium instruments inside single and double-curved canals at different temperatures. 160 HyFlex EDM #20.05 (HEDM), VDW.ROTATE #20.05 and #25.06, Mtwo #25.06 were randomised (n = 10) for the dynamic cyclic fatigue tests according to the curvature (i.e. single and double) at 20° ± 1°C and 35° ± 1°C. The number of cycles to fracture (NCF) was analysed by two-way ANOVA with p < 0.05. Fatigue resistance of all instruments significantly decreased at body temperature in single and double curvatures, except for HEDM in double curvature. The NCF was significantly lower in double curvature than single at both temperatures for all files, except for VDW.ROTATE #20.05 at 35° ± 1°C. Within the study limitations, temperature significantly impaired cyclic fatigue resistance of all files except HEDM #20.05 in double curvature. Similarly, double curvature had a detrimental effect on cyclic fatigue resistance of all files except for VDW.ROTATE #20.05 at body temperature.


Assuntos
Instrumentos Odontológicos , Níquel , Titânio , Temperatura Corporal , Ligas Dentárias , Desenho de Equipamento , Falha de Equipamento , Teste de Materiais , Preparo de Canal Radicular , Resistência à Flexão
14.
J Endod ; 49(10): 1344-1351, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37516238

RESUMO

INTRODUCTION: This laboratory study aimed to evaluate the accumulated hard tissue debris (AHTD) and shaping performance following root canal instrumentation with a novel stainless steel rotary system (Gentlefile; MedicNRG, Kibbutz Afikim, Israel) compared with two single-file nickel-titanium instruments of different kinematics through micro-computed tomography (micro-CT) analysis. METHODS: Thirty isthmus-containing mesial roots of human mandibular molars with a curvature of 15°-35° were scanned with micro-CT at an isotropic resolution of 12 µm and randomly assigned to three groups (n = 10) according to the instruments used for canal preparation: Gentlefile (GF; #23/.04), One Curve (OC; #25/.06; Micro-Mega, Besancon, France), and Reciproc Blue R25 (RB; #25/.08; VDW, Munich, Germany). The AHTD, unprepared canal surface area, volume changes, surface area changes, and transportation were evaluated by comparing preoperative and postoperative micro-CT images. In addition, the time required for canal preparation was recorded. Data were statistically analyzed using the one-way analysis of variance (ANOVA) test or the Kruskal-Wallis test at a significance level of 5%. RESULTS: No significant differences were observed in the percentage of AHTD or in the unprepared canal surface area between the three groups (P > .05). The RB group demonstrated a significantly greater percentage increase in volume and surface area than the GF group (P < .05). The GF and OC groups showed significantly less transportation at 3 mm from the apex than the RB group (P < .001). The OC group required significantly less time for instrumentation than the RB and GF groups (P < .05). CONCLUSIONS: Instrumentation with GF (#23/.04), OC, and RB yielded similar levels of AHTD and unprepared surface area in isthmus-containing curved canals. GF achieved this with less dentin removal and apical transportation, at the expense of a longer preparation time.


Assuntos
Cavidade Pulpar , Preparo de Canal Radicular , Humanos , Cavidade Pulpar/diagnóstico por imagem , Cavidade Pulpar/cirurgia , Microtomografia por Raio-X , Raiz Dentária , Dente Molar/diagnóstico por imagem , Dente Molar/cirurgia , Desenho de Equipamento
15.
Microsc Res Tech ; 86(10): 1345-1352, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37066970

RESUMO

To compare the shaping ability of Procodile and R6 Reziflow instruments used in reciprocating motion in severely curved root canals, assessed with micro-computed tomography (µCT). Fourteen extracted human mandibular first molars were randomly assigned to two instrumentation techniques (n = 14 mesial root canals): Procodile or R6 Reziflow. For both groups, root canals were prepared to the working length up to a size 25, .06 taper. Molars were virtually divided into apical, middle and coronal thirds and µCT was used to scan all samples pre- and post-root canal. Canal transportation, centring ability, volume, surface area and unprepared area were evaluated. Geometrical parameter changes were compared with preoperative values (one-way analyses of variance and Tukey multiple comparison post-hoc test) between groups and Student t-test within groups (α = 0.05) Significantly less transportation was observed associated with the Procodile technique in the molar's coronal third compared to the R6 Reziflow technique (p < .05). No significant differences in root canal centring ability, volume, surface area and unprepared area were observed. Procodile showed a lower percentage increase of surface area compared to R6 Reziflow (p < .05). The Procodile and R6 Reziflow techniques applied to first molar root canal performed similarly except for the less transportation observed in the coronal third using Procodile. RESEARCH HIGHLIGHTS: MicroCT analysis of canal geometry before and after instrumentation revealed that Procodile and R6 Reziflow showed a similar shaping ability to shape curved root canals without substantially modifications of the original tooth anatomy.


Assuntos
Cavidade Pulpar , Níquel , Humanos , Microtomografia por Raio-X/métodos , Cavidade Pulpar/diagnóstico por imagem , Titânio , Preparo de Canal Radicular/métodos , Desenho de Equipamento
16.
J Clin Med ; 12(8)2023 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-37109310

RESUMO

This paper investigates the influence of cavity configuration and post-endodontic restoration on the fracture resistance, failure mode and stress distribution of premolars by using a method of fracture failure test and finite elements analysis (FEA) coupled to Weibull analysis (WA). One hundred premolars were divided into one control group (Gcontr) (n = 10) and three experimental groups, according to the post-endodontic restoration (n = 30), G1, restored using composite, G2, restored using single fiber post and G3, restored using multifilament fiberglass posts (m-FGP) without post-space preparation. Each experimental group was divided into three subgroups according to the type of coronal cavity configuration (n = 10): G1O, G2O, and G3O with occlusal (O) cavity configuration; G1MO, G2MO, and G3MO with mesio-occlusal (MO); and G1MOD, G2MOD, and G3MOD with mesio-occluso-distal (MOD). After thermomechanical aging, all the specimens were tested under compression load, and failure mode was determined. FEA and WA supplemented destructive tests. Data were statistically analyzed. Irrespective of residual tooth substance, G1 and G2 exhibited lower fracture resistance than Gcontr (p < 0.05), whereas G3 showed no difference compared to Gcontr (p > 0.05). Regarding the type of restoration, no difference was highlighted between G1O and G2O, G1MO and G2MO, or G1MOD and G2MOD (p > 0.05), whereas G3O, G3MO, and G3MOD exhibit higher fracture resistance (p < 0.05) than G1O and G2O, G1MO and G2MO, and G1MOD and G2MOD, respectively. Regarding cavity configuration: in G1 and G2, G1O and G2O exhibited higher fracture resistance than G1MOD and G2MOD, respectively (p < 0.05). In G3, there was no difference among G3O, G3MO and G3MOD (p > 0.05). No difference was found among the different groups and subgroups regarding the failure mode. After aging, premolars restored with multifilament fiberglass posts demonstrated fracture resistance values comparable to those of an intact tooth, irrespective of the different type of cavity configuration.

17.
Clin Oral Investig ; 27(7): 3321-3330, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37014504

RESUMO

OBJECTIVES: The aim of this scoping review was to determine the effectiveness of the platelet-rich fibrin in the control of pain associated with alveolar osteitis. MATERIALS AND METHODS: Reporting was based on Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) Extension for Scoping Reviews. A literature search was conducted in the PubMed and Scopus databases to identify all clinical studies on the application of platelet-rich fibrin in the control of pain caused by alveolar osteitis. Data were extracted independently by two reviewers and qualitatively described. RESULTS: The initial search returned 81 articles, with 49 identified after duplicates removal; of these, 8 were selected according to the inclusion criteria. Three of the eight studies were randomized controlled clinical trials, and four were non-randomized clinical studies, two of which were controlled. One study was case series. In all of these studies, pain control was evaluated using the visual analog scale. Overall, the use of platelet-rich fibrin resulted effective in the control of pain determined by alveolar osteitis. CONCLUSIONS: Within the limits of this scoping review, the application of platelet-rich fibrin in the post-extra-extraction alveolus reduced the pain associated with alveolar osteitis in almost all the included studies. Nevertheless, high-quality randomized trials with adequate sample size are warranted to draw firm conclusions. CLINICAL RELEVANCE: Pain associated with alveolar osteitis causes discomfort to the patient and is challenging to be treated. Use of platelet-rich fibrin could be a promising clinical strategy for pain control in alveolar osteitis if its effectiveness will be confirmed by further high-quality studies.


Assuntos
Alvéolo Seco , Fibrina Rica em Plaquetas , Humanos , Dente Serotino , Dor , Extração Dentária/efeitos adversos , Cicatrização
18.
Aust Endod J ; 49 Suppl 1: 353-358, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36960975

RESUMO

The aim of this study was to evaluate the debridement efficacy of sonic irrigation (EDDY; VDW, Munich, Germany and EndoActivator; Dentsply-Sirona, Ballaigues, Switzerland) and ultrasonically activated irrigation (Irrisafe; Satelec Acteon, Merignac, France) in a simulated canal isthmus connecting curved canals. Transparent resin blocks were produced containing two curved canals connected with an isthmus. The isthmus was then filled with dentin debris. Three irrigant activation cycles were performed and the amount of remaining debris was compared analysing pictures taken after each activation cycle. Data were statistically analysed using one-way ANOVA and post hoc Tukey tests at a significance level of p < 0.05. EDDY showed greater efficiency in removing dentin debris from the simulated isthmus than the other techniques tested. An increase in the activation time enhanced the efficiency of both EDDY and ultrasonically activated irrigation in debris removal.


Assuntos
Cavidade Pulpar , Preparo de Canal Radicular , Preparo de Canal Radicular/métodos , Irrigantes do Canal Radicular/uso terapêutico , Dente Molar , Irrigação Terapêutica/métodos , Dentina
19.
Odontology ; 111(4): 910-915, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36917401

RESUMO

To compare the amount of extruded debris caused by different motions using a single-file system. Fifty mandibular first molar teeth were randomized into 5 groups (n = 10) according to the motion tested: Optimize Torque Reverse (OTR), TF Adaptive Motion (TFA), continuous rotation (CR), reciprocation motion (+ 150°, -30°) (REC), and Jeni motion (Jeni). One Curve single file 25/06 (Micro-Mega, Besançon, France) was used in all experimental groups. The root canals were irrigated with 2.5% NaOCl, and the extruded debris were collected at pre-weighted glass vials. The glass vials were kept inside an incubator for one week at 70 °C to dry out the irrigating solution. The extruded debris was quantified by subtracting the pre-instrumentation from the post-instrumentation weight of the glass vials. The time required for each instrumentation procedure was digitally recorded. All data were analyzed statistically with one way ANOVA and post hoc Tukey test (P < 0.05). All the motions extruded apically debris with Jeni mode caused significantly less debris extrusion than TFA, REC, and CR (P < 0.05) while no significant difference emerged with OTR. Preparation time was not significantly different in all groups. Within the limits of the present study, all the kinematics produced apically debris extrusion, with Jeni reporting a similar amount of debris compared with OTR and significantly less than TFA, REC, and CR. Preparation time was similar among the tested kinematics.


Assuntos
Preparo de Canal Radicular , Ápice Dentário , Fenômenos Biomecânicos , Cavidade Pulpar , Dente Molar
20.
J Clin Med ; 12(1)2023 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-36615157

RESUMO

Nickel-titanium (NiTi) usage is associated in endodontics with some complications including canal transportation. Centering ability of a NiTi file is the ability to stay centered in the root canal system during instrumentation. Any undesirable deviation from the natural canal path is indicated as canal transportation. A possible strategy to improve the centering ability of NiTi instruments is the pre-enlargement of the coronal third of the root canal to minimize coronal interferences. This procedure is known as coronal flaring. The aim of this study was to perform a micro-computed tomographic (micro-CT) evaluation of the effect of coronal flaring on canal transportation and centering ability of two heat treated nickel-titanium rotary instruments, 2Shape (Micro Mega, Besançon, France) and HyFlex CM (Coltène Whaledent, Altstätten, Switzerland). Thirty extracted mandibular molars with two independent mesial canals were selected and randomly instrumented (n = 15 canals) with One Flare (Micro Mega, Besançon, France) before HyFlex CM, HyFlex CM (without coronal flaring), One Flare before 2Shape and 2Shape (without coronal flaring). One Flare (Micro Mega, Besançon, France) was introduced 4 mm below the canal entrance for canals prepared with coronal flaring. HyFlex CM and 2Shape were used accordingly to manufacturers' instructions. New files were used for each canal. During and after instrumentation, irrigation procedures were performed. Micro-CT images were obtained pre- and post-preparation to measure and record root canal transportation and centralization. They were reconstructed from root apex to canal orifices, generating approximately 1000 sections per specimen. The anatomical thirds were determined by dividing the number of cross-sectional slices by three. Root canal transportation and centralization were determined by Gambil method, and the mean values were analyzed by repeated measures analysis of variance followed by multiple comparisons of Bonferroni to compare the different instrumentations procedures and the root thirds (p < 0.05). As for root canal transportation, 2Shape reported significantly higher values compared to HyFlex CM in the cervical region independently from the coronal flaring. In the apical region, 2Shape caused significantly minor canal transportation when used with coronal flaring with compared with the absence of coronal flaring. Regarding the centralization, HyFlex CM showed higher values than 2Shape in the cervical, independently from coronal flaring. In the apical region, 2Shape with coronal flaring exhibited significant major centering ratio, compared with not. Within the limitations of this study, coronal flaring reduced canal transportation and improved centralization of the 2Shape files in the apical section while it had no significant influence on shaping ability of the HyFlex CM instruments. Coronal flaring could represent a valid strategy to improve the shaping ability of NiTi files knowing that its benefit could be influenced by the shaping file used.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA