Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
1.
Arthroscopy ; 36(11): 2805-2811, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32554073

RESUMO

PURPOSE: The purpose of this study was to evaluate the cyclic displacement, stiffness, and ultimate load to failure of 3 all-suture anchors in human cadaveric greater tuberosities. METHODS: Three all-suture anchors indicated for rotator cuff repair were tested in 14 matched pairs of human cadaver fresh-frozen humeri. Anchors were inserted at 3 locations from anterior to posterior along the greater tuberosity and placed 5 mm from the articular margin. The constructs were cycled from 10 to 60 N at 1 Hz for 200 cycles. The anchors that survived cycling were then subjected to a single pull to failure test. A Kruskal-Wallis 1-way analysis of variance on ranks was performed to compare the displacement, stiffness, and ultimate load to failure of the different anchors tested. RESULTS: One matched pair was excluded because of poor bone quality; therefore, 13 matched pairs were included in the study. After 20, 100, and 200 cycles, there was no difference in median displacement between the anchors tested (P = .23, P = .21, P = .18, respectively). The median ultimate load-to-failure between the Iconix (295.2 N, 95% confidence interval [CI], 125-762.2), JuggerKnot (287.6 N, 95% CI, 152.9-584.4), and Q-fix (333.3 N, 95% CI, 165.0-671.9) showed no statistically significant difference (P = .58). After 20, 100, and 200 cycles, there was no difference in median stiffness between the anchors tested (P = .41, P = .19, P = .26 respectively). Displacement greater than 5 mm occurred in 0 Iconix anchors (0%), 1 JuggerKnot anchor (3.64%), and 2 Q-fix anchors (7.69%). One JuggerKnot anchor failed by anchor pullout during cyclic loading. CONCLUSIONS: When tested in human cadaveric humeral greater tuberosities 3 all-suture anchors, the 2.9-mm JuggerKnot, the 2.8-mm Q-fix, and the 2.3-mm Iconix, showed no significant differences in median displacement or stiffness after 20, 100, or 200 cycles or in median ultimate load to failure. Although not statistically significant, the Iconix was the only anchor tested to have no failures, whereas the JuggerKnot had both a clinical and catastrophic failure and the Q-fix had 2 clinical failures. LEVEL OF EVIDENCE: Level V, Controlled Laboratory Study.


Assuntos
Ombro/cirurgia , Âncoras de Sutura , Técnicas de Sutura , Idoso , Artroplastia , Fenômenos Biomecânicos , Cadáver , Feminino , Humanos , Úmero/cirurgia , Masculino , Teste de Materiais , Pessoa de Meia-Idade , Falha de Prótese , Estresse Mecânico
2.
Gait Posture ; 76: 193-197, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31862669

RESUMO

BACKGROUND: Wearable sensors have allowed researchers to instrument tests of gait-related mobility, including the widely used timed 'up-and-go' test (TUG). Currently, there is a lack of instrumented test data on whether children with moderate to severe traumatic brain injury (TBI) perform differently on the TUG compared to typically developed (TD) controls during a cognitive-motor task. RESEARCH QUESTION: The aim was to explore the effects of a cognitive-motor task on TUG subcomponents among children with TBI compared to TD children. METHODS: This observational cross-sectional study included 12 children with moderate to severe TBI (6 males and 6 females, age 10.5 ±â€¯1.5 years of age) and 10 age and sex-matched TD controls (5 males and 5 females, 10.4 ±â€¯1.3 years of age). Each participant completed 6 trials of the TUG wearing a single inertial measurement unit sensor at a self-selected walking pace while listening to an array of 10 randomly presented single digits during each TUG trial. RESULTS: Total time to complete the TUG was not significantly different between groups. The cognitive-motor task led to significantly lower mean turn and peak turn angular velocity values during the turn-around-the-cone and turn-before-sitting TUG subcomponents in children with TBI compared to the TD controls (p ≤ 0.05). Additionally, the cognitive-motor task led to significantly lower values for maximum torso flexion to extension angle, peak flexion and extension angular velocity and peak vertical acceleration for the sit-to-stand subcomponent (p < 0.05). Peak flexion angular velocity during the stand-to-sit subcomponent was lower for the TBI group compared to the children with TD (p < 0.05). SIGNIFICANCE: The study provides new insights into the performance of complex gait-related mobility tasks in the context of an instrumented TUG among children with moderate to severe TBI. Our results highlight the potential benefits of outfitting pediatric inpatients with an IMU while completing the TUG.


Assuntos
Lesões Encefálicas Traumáticas/fisiopatologia , Desenvolvimento Infantil , Marcha/fisiologia , Programas de Rastreamento/métodos , Equilíbrio Postural/fisiologia , Velocidade de Caminhada/fisiologia , Aceleração , Adolescente , Lesões Encefálicas Traumáticas/diagnóstico , Criança , Estudos Transversais , Feminino , Humanos , Masculino , Estudos de Tempo e Movimento , Tronco/fisiopatologia
3.
J Orthop Trauma ; 34(1): e20-e25, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31567796

RESUMO

OBJECTIVES: To describe surgical technique for proper placement of the clavicle hook plate, determine whether there is subacromial impingement caused by hook plate fixation, and evaluate the mechanical strength of the clavicle hook plate construct. METHODS: Eight fresh-frozen cadaveric shoulders with a mean age of 48 years (range, 37-69) were used. Open reduction and internal fixation of simulated Rockwood type V AC joint dislocation was performed with the clavicle hook plate. Three-dimensional computed tomography studies and arthroscopic evaluation were performed with the glenohumeral joint in different orientations to assess the position of the hook plate relative to relevant joint structures. The clavicle was then superiorly loaded to mechanical failure. RESULTS: Computed tomography evaluations showed no contact between the humerus and the hook plate. Distance between the greater tuberosity and hook plate ranged from 14 to 31 mm with maximal shoulder forward flexion and 8.1-25.4 mm with maximal shoulder abduction. Arthroscopic evaluation of the subacromial space demonstrated that with maximal abduction/forward flexion, there was abutment of the rotator cuff with the hook plate in 6 of 8 specimens. In mechanical testing, mean failure load was determined to be 1011 N (range, 380-1563 N). Failure mechanisms included acromion fracture (4), slippage of the hook under acromion (3), and distal clavicle fracture (1). CONCLUSIONS: This study demonstrates that the clavicle hook plate reduces AC joint dislocation or distal clavicle fractures anatomically, has supra-physiologic mechanical strength, does not cause bony impingement, and exhibits rotator cuff impingement only with maximal abduction/forward flexion of the shoulder.


Assuntos
Articulação Acromioclavicular , Luxações Articulares , Articulação Acromioclavicular/diagnóstico por imagem , Articulação Acromioclavicular/cirurgia , Acrômio , Adulto , Idoso , Placas Ósseas , Cadáver , Clavícula/diagnóstico por imagem , Clavícula/cirurgia , Fixação Interna de Fraturas , Humanos , Pessoa de Meia-Idade , Resultado do Tratamento
4.
Arthroscopy ; 35(7): 1954-1959.e4, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-30979619

RESUMO

PURPOSE: To evaluate the cyclic displacement and ultimate load to failure of 4 all-suture anchors in human cadaveric shoulder glenoid bone. METHODS: Four all-suture anchors indicated for glenoid labral repair were tested in 14 matched pairs of human cadaveric fresh-frozen glenoids. Anchors were inserted at 4 different locations for a total of 112 tests (12-, 3-, 6-, and 9-o'clock positions for right glenoids). Cyclic loading (10 to 60 N at 1 Hz for 200 cycles) and single pull-to-failure testing (33 mm/s) were performed. A Kruskal-Wallis 1-way analysis of variance with the Dunn multiple-comparison post hoc test was used for statistical analysis. RESULTS: One matched pair was excluded because of poor bone quality. Thus, 13 matched pairs were included in the study, and a total of 104 tests were performed. The Q-Fix anchors showed significantly less displacement after 100 cycles (mean ± standard deviation, 1.40 ± 0.97 mm; P < .001) and 200 cycles (1.53 ± 1.00 mm, P < .001) than all other anchors tested. The Q-Fix (191.3 ± 65.8 N), Suturefix (188.3 ± 61.4 N), and JuggerKnot (183.6 ± 63.5 N) anchors had significantly greater ultimate loads to failure than the Iconix anchors (143.5 ± 54.1 N) (P = .01, P = .012, and P = .021, respectively). Displacement greater than 5 mm occurred in 6 Iconix anchors (22.1%), 5 Suturefix anchors (19.2%), 4 JuggerKnot anchors (15.4%), and 0 Q-Fix anchors (0%). CONCLUSIONS: The Q-Fix anchors showed less displacement with cyclic loading than the Iconix, JuggerKnot, and Suturefix anchors. The Iconix anchors had a lower ultimate load to failure than the Q-Fix, Suturefix, and JuggerKnot anchors. Only the Q-Fix group had no anchors displace greater than 5 mm with cyclic loading. CLINICAL RELEVANCE: All-suture anchors vary in their deployment mechanism, which may alter their strength and performance. Operators must be aware of these anchors' propensity to displace while deploying them.


Assuntos
Artroscopia/métodos , Articulação do Ombro/cirurgia , Âncoras de Sutura , Técnicas de Sutura/instrumentação , Idoso , Fenômenos Biomecânicos , Cadáver , Humanos , Pessoa de Meia-Idade , Articulação do Ombro/fisiopatologia
5.
Arthroscopy ; 34(10): 2777-2781, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-30195950

RESUMO

PURPOSE: To evaluate the effect of greater tuberosity decortication on ultimate load to failure and displacement after cyclic loading with an all-suture anchor. METHODS: A 2.9-mm all-suture anchor was evaluated in decorticated and nondecorticated greater tuberosities of 10 matched pairs of human cadaveric shoulders. Greater tuberosity decortication was performed to a mean depth of 1.7 mm. Anchors were placed in the anterior, middle, and posterior tuberosity. Anchors were tested under cyclic loads followed by load-to-failure testing. Displacement after 20, 100, and 200 cycles and ultimate failure strength were determined. Clinical failure was defined as displacement greater than 5 mm during cyclic loading. RESULTS: After 20 and 100 cycles, there was no difference in mean displacement between the decorticated and nondecorticated cohorts (P = .139 and P = .127, respectively). The mean displacement after 200 cycles was greater in the decorticated cohort, although not significantly (3.4 vs 2.7 mm; P = .05). The mean ultimate load to failure was significantly lower in the decorticated cohort (314 vs 386 N, P = .049). There were 2 clinical failures in the decorticated specimens and 1 in the nondecorticated specimens. CONCLUSIONS: A minimal greater tuberosity decortication significantly decreases the ultimate load to failure of an all-suture anchor. However, decreased biomechanical strength may not necessitate actual clinical failure. CLINICAL RELEVANCE: A decrease in ultimate load to failure could increase the risk of catastrophic postoperative anchor failure. However, while this decrease in strength is statistically significant, the overall decrease in strength may not be sufficient in magnitude to translate to clinical failure.


Assuntos
Artroplastia/métodos , Lesões do Manguito Rotador/cirurgia , Manguito Rotador/cirurgia , Âncoras de Sutura , Idoso , Fenômenos Biomecânicos , Cadáver , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estresse Mecânico , Técnicas de Sutura
6.
Gait Posture ; 63: 248-253, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29778065

RESUMO

BACKGROUND: Studies have evaluated the test-re-test reliability of subcomponents of the timed up and-go test in adults by using body-worn inertial sensors. However, studies in children have not been reported in the literature. RESEARCH QUESTION: To evaluate the within-session reliability of subcomponents of a newly developed electronically augmented timed 'upand-go' test (EATUG) in ambulatory children with traumatic brain injury (TBI) and children with typical development (TD). METHOD: The timed up and go test was administered to twelve consecutive ambulatory children with moderate to severe TBI (6 males and 6 females, age 10.5 ±â€¯1.5 years, range 8-13 years, during inpatient rehabilitation at 27.0 ±â€¯11.8 days following injury) and 10 TD age and sex-matched children (5 males and 5 females, 10.4 ±â€¯1.3 years, range 8-11 years). Participants wore a single chest-mounted inertial measurement sensor package with custom software that measured angular and acceleration velocity and torso flexion and extension angles, while they performed 6 trials of the EATUG test. Measures were derived from the overall time to complete the TUG test, angular velocity and angular displacement data for torso flexion and extension during sit-to-stand and stand-to-sit segments and both mean and peak angular velocities for two turning segments (i.e. turning around a cone and turning-before-sitting). RESULTS: Within-session reliability of the subcomponents of the TUG test for children with TBI assessed by the intra-class correlation coefficient was ICC (1,1) = 0.84, (range 0.82-0.96), and for TD children ICC (1,1) = 0.73, (range 0.53-0.89). Scores on Total Time, maximum torso flexion/extension angle and peak flexion angular velocity during sit-tostand, and peak turn angular velocity for both turns around the cone and turns before sitting were lower for children with TBI than for TD children (p ≤ 0.05). SIGNIFICANCE: The EATUG test is a reliable measure of physical function in children with TBI who are being discharged from inpatient rehabilitation.


Assuntos
Lesões Encefálicas Traumáticas/diagnóstico , Atividade Motora/fisiologia , Postura , Tempo de Reação , Processamento de Sinais Assistido por Computador/instrumentação , Aceleração , Adolescente , Lesões Encefálicas Traumáticas/fisiopatologia , Lesões Encefálicas Traumáticas/reabilitação , Criança , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Tronco
7.
Arthroscopy ; 34(5): 1384-1390, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29456066

RESUMO

PURPOSE: To determine if the depth of anchor insertion affects the biomechanical performance of a 1.5-mm all-suture anchor in glenoid bone. METHODS: A 1.5-mm all-suture anchor was tested in 8 matched pairs of human cadaver fresh-frozen glenoids. Anchors were inserted at 6 different locations and tested at 3 different depths: 21 mm (preset drilling depth), 17 mm, and 13 mm. Cyclic loading and destructive testing was performed. Displacement after 100 and 200 cycles, along with ultimate failure strength, was determined. RESULTS: After 100 and 200 cycles, anchors placed at 13 and 17 mm had undergone significantly less displacement than those at 21 mm (P < .05). No difference was observed in ultimate load to failure between anchors placed at 21 and 17 mm. However, the ultimate load to failure was significantly lower in anchors placed at 13 mm (P < .05). There were 5 clinical failures in anchors placed at 21 mm, one at 17 mm, and none at 13 mm. CONCLUSIONS: The 1.5-mm all-suture anchor tested in this study has an optimal insertion depth of 17 mm, 4 mm shallower than the preset drill depth. At the optimal insertion depth of 17 mm, it underwent significantly less displacement after cyclic loading without a reduction in the ultimate load to failure. CLINICAL RELEVANCE: Given the results of this study, the optimal insertion depth for this 1.5-mm all-suture anchor is 17 mm, 4 mm shallower than the preset drill depth.


Assuntos
Artroscopia/instrumentação , Cavidade Glenoide/fisiologia , Cavidade Glenoide/cirurgia , Âncoras de Sutura , Idoso , Fenômenos Biomecânicos , Cadáver , Humanos , Teste de Materiais , Pessoa de Meia-Idade , Técnicas de Sutura , Resistência à Tração
8.
Orthop J Sports Med ; 5(8): 2325967117719857, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28840144

RESUMO

BACKGROUND: Improved biomechanical and clinical outcomes are seen when the femoral tunnels of the anterior cruciate ligament (ACL) are placed in the center of the femoral insertion. The transtibial (TT) technique has been shown to be less capable of this than an anteromedial (AM) portal approach but is more familiar to surgeons and less technically challenging. A hybrid transtibial (HTT) technique using medial portal guidance of a transtibial guide wire without knee hyperflexion may offer anatomic tunnel placement while maintaining the relative ease of a TT technique. PURPOSE: To evaluate the anatomic and biomechanical performance of the HTT technique compared with TT and AM approaches. STUDY DESIGN: Controlled laboratory study. METHODS: Thirty-six paired, fresh-frozen human knees were used. Twenty-four knees (12 pairs) underwent all 3 techniques (TT, AM, HTT) for femoral tunnel placement, with direct measurement of femoral insertional overlap and femoral tunnel length. The remaining 12 knees (6 pairs) underwent completed reconstructions to evaluate graft anisometry and tunnel orientation, with each technique performed in 4 specimens and tested using motion sensors with a quad-load induced model. Graft length changes and graft/femoral tunnel angle were measured at varying degrees of flexion. RESULTS: Percentage overlap of the femoral insertion averaged 37.0% ± 28.6% for TT, 93.9% ± 5.6% for HTT, and 79.7% ± 7.7% for AM, with HTT significantly greater than both TT (P = .007) and AM (P = .001) approaches. Graft length change during knee flexion (anisometry) was 30.1% for HTT, 12.8% for AM, and 8.5% for TT. When compared with the TT approach, HTT constructs exhibited comparable graft-femoral tunnel angulation (TT, 150° ± 3° vs HTT, 142° ± 2.3°; P < .001) and length (TT, 42.6 ± 2.8 mm vs HTT, 38.5 ± 2.0 mm; P = .12), while AM portal tunnels were significantly shorter (31.6 ± 1.6 mm; P = .001) and more angulated (121° ± 6.5°; P < .001). CONCLUSION: The HTT technique avoids hyperflexion and maintains femoral tunnel orientation and length, similar to the TT technique, but simultaneously achieves anatomic graft positioning. CLINICAL RELEVANCE: The HTT technique offers an anatomic alternative to an AM portal approach while maintaining the technical advantages of a traditional TT reconstruction.

9.
Arthroscopy ; 32(12): 2490-2494, 2016 12.
Artigo em Inglês | MEDLINE | ID: mdl-27614390

RESUMO

PURPOSE: To quantify the distance of the dorsal ulnar sensory branch, floor of the extensor carpi ulnaris (ECU) subsheath, and ulnar neurovascular bundles from the triangular fibrocartilage complex (TFCC), and secondarily to assess the safety of an all-inside arthroscopic repair of the TFCC with a commonly used meniscal repair device with respect to the aforementioned structures. METHODS: A custom K-wire with 1-mm gradation was used to determine the distance of at-risk structures from the periphery of the TFCC in 13 above-elbow human cadaver specimens. An all-inside repair of the TFCC at the location of a Palmer 1B tear was then performed using a commonly employed meniscal repair device. The distance from the deployed devices to the structure in closest proximity was then measured using digital calipers. RESULTS: The mean distance from the deployed device to the nearest structure of concern for iatrogenic injury was 9.4 mm (range, 5-15 mm). The closest structure to iatrogenic injury was usually, but not always, the dorsal ulnar sensory nerve in 9 of 13 wrists (69.2%) at 9.3 mm (range, 5-15 mm); on 3 occasions it was instead the ulnar nerve (23.1%) at 9.5 mm (range, 9-10 mm), and on 1 occasion 6 mm from the flexor digitorum profundus to the little finger (7.7%). Forearm rotation had no significant effect on measured distances (ulnar nerve: P = .98; dorsal sensory: P = .89; ECU: P = .90). The largest influence of forearm rotation was a 0.4-mm difference between pronation and supination with respect to the distance of the TFCC periphery on the ECU subsheath. CONCLUSIONS: An all-inside arthroscopic TFCC repair using a commonly used meniscal repair device appears safe with respect to nearby neurovascular structures and tendons under typical arthroscopic conditions. CLINICAL RELEVANCE: An all-inside arthroscopic TFCC repair using a commonly employed meniscal repair device appears safe in terms of proximity to important structures although further clinical investigation is warranted.


Assuntos
Artroscopia/métodos , Fibrocartilagem Triangular/anatomia & histologia , Fibrocartilagem Triangular/cirurgia , Artroscopia/instrumentação , Cadáver , Humanos , Doença Iatrogênica/prevenção & controle , Traumatismos dos Tendões/prevenção & controle , Tendões/anatomia & histologia , Nervo Ulnar/anatomia & histologia
10.
Am J Sports Med ; 44(10): 2622-2628, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27390345

RESUMO

BACKGROUND: Patellar tendon ruptures require surgical repair to optimize outcomes, but no consensus exists regarding the ideal repair technique. Cortical button fixation is a secure method for tendon repair that has not been studied in patellar tendons. HYPOTHESIS: Cortical button repair is biomechanically superior to the standard transpatellar repair and biomechanically equivalent to suture anchor repair. STUDY DESIGN: Controlled laboratory study. METHODS: Twenty-three fresh-frozen cadaveric knees were used to compare 3 techniques of patellar tendon repair after a simulated rupture at the inferior pole of the patella. Repairs were performed at 45° of flexion using a standard transpatellar suture repair (n = 7), polyetheretherketone (PEEK) suture anchor repair (n = 8), or cortical button repair (n = 8). All specimens were tested on a custom apparatus to simulate cyclic open kinetic chain quadriceps contraction from extension to 90o of flexion. Outcomes of gap formation up to 250 cycles, maximum load to failure, and mode of failure were evaluated. RESULTS: Cortical button repair had significantly less gap formation than anchor repair after 1 cycle (P < .001) and 20 cycles (P < .01) and significantly less gap formation than suture repair from 1 to 250 cycles (P < .05). Cortical button repair sustained significantly higher loads to failure than anchor repair and suture repair (P < .001). All suture repairs failed through the suture. Anchor repairs failed at the suture-anchor eyelet interface (n = 4) or by anchor pullout (n = 3). Cortical button repairs either failed through the suture (n = 5), secondary failure of the patellar tendon (n = 2), or subsidence of the button through the anterior cortex of the patella (n = 1). CONCLUSION: Patellar tendon repair using cortical button fixation demonstrated mechanical advantages over suture repair and anchor repair in cadaveric specimens. Cortical button fixation showed less cyclic gap formation and withstood at least twice the load to failure of the construct. CLINICAL RELEVANCE: The biomechanical superiority of cortical button fixation may impart clinical advantages in accelerating postoperative rehabilitation.


Assuntos
Patela/cirurgia , Ligamento Patelar/cirurgia , Âncoras de Sutura , Traumatismos dos Tendões/cirurgia , Adulto , Idoso , Fenômenos Biomecânicos , Cadáver , Feminino , Humanos , Traumatismos do Joelho/cirurgia , Masculino , Pessoa de Meia-Idade , Músculo Quadríceps/cirurgia , Amplitude de Movimento Articular , Ruptura/cirurgia , Técnicas de Sutura , Suturas , Tendões/cirurgia
11.
J Sport Rehabil ; 25(3): 213-8, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27445119

RESUMO

CONTEXT: Knee osteoarthritis (OA) is a debilitating disease that affects an estimated 27 million Americans. Changes in lower-extremity alignment and joint laxity have been found to redistribute the medial and/or lateral loads at the joint. However, the effect that changes in anteroposterior knee-joint laxity have on lower-extremity alignment and function in individuals with knee OA remains unclear. OBJECTIVE: To examine anteroposterior knee-joint laxity, lower-extremity alignment, and subjective pain, stiffness, and function scores in individuals with early-stage knee OA and matched controls and to determine if a relationship exists among these measures. DESIGN: Case control. SETTING: Sports-medicine research laboratory. PARTICIPANTS: 18 participants with knee OA and 18 healthy matched controls. INTERVENTION: Participants completed the Western Ontario McMaster (WOMAC) osteoarthritis questionnaire and were tested for total anteroposterior knee-joint laxity (A-P) and knee-joint alignment (ALIGN). MAIN OUTCOME MEASURES: WOMAC scores, A-P (mm), and ALIGN (°). RESULTS: A significant multivariate main effect for group (Wilks' Λ = 0.30, F7,26 = 8.58, P < .0001) was found. Knee-OA participants differed in WOMAC scores (P < .0001) but did not differ from healthy controls on ALIGN (P = .49) or total A-P (P = .66). No significant relationships were identified among main outcome measures. CONCLUSION: These data demonstrate that participants with early-stage knee OA had worse pain, stiffness, and functional outcome scores than the matched controls; however, ALIGN and A-P were no different. There was no association identified among participants' subjective scores, ALIGN, or A-P measures in this study.


Assuntos
Anteversão Óssea/etiologia , Retroversão Óssea/etiologia , Instabilidade Articular/etiologia , Articulação do Joelho/fisiopatologia , Extremidade Inferior/fisiopatologia , Osteoartrite do Joelho/fisiopatologia , Índice de Gravidade de Doença , Idoso , Anteversão Óssea/diagnóstico , Anteversão Óssea/fisiopatologia , Retroversão Óssea/diagnóstico , Retroversão Óssea/fisiopatologia , Estudos de Casos e Controles , Feminino , Humanos , Instabilidade Articular/diagnóstico , Instabilidade Articular/fisiopatologia , Masculino , Pessoa de Meia-Idade , Osteoartrite do Joelho/diagnóstico , Medição da Dor , Qualidade de Vida
12.
Am J Orthop (Belle Mead NJ) ; 44(2): 82-5, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25658077

RESUMO

We conducted a study to biomechanically compare 4 tibial hamstring tendon fixation devices commonly used in anterior cruciate ligament reconstruction. Quadrupled human semitendinosus-gracilis tendon grafts were fixed into porcine tibias using 4 separate fixation devices. For each device, 10 specimens were tested (1500-cycle loading test at 50-200 N). Specimens surviving the cyclic loading then underwent a single load-to-failure test. Failure mode, stiffness, ultimate load, and residual displacement were recorded. Eight of 10 Delta screw (Arthrex), 2 of 10 Retroscrew (Arthrex), 10 of 10 WasherLoc (Arthrotek), and 10 of 10 Intrafix (Depuy Mitek) devices completed the 1500-cycle loading test. Residual displacement was significantly (P < .001) lower for Intrafix (2.9 mm), WasherLoc (5.6 mm), and Delta (6.4 mm) than for Retroscrew (25.5 mm). Mean stiffness was significantly (P < .05) higher for Intrafix (129 N/mm) than for the other devices. Mean load to failure was highest for Intrafix (656 N), then WasherLoc (630 N), Delta (430 N), and Retroscrew (285 N). The Intrafix device demonstrated superior strength in the fixation of hamstring grafts in the tibia. WasherLoc was close behind.


Assuntos
Reconstrução do Ligamento Cruzado Anterior/instrumentação , Tendões/cirurgia , Tíbia/cirurgia , Animais , Ligamento Cruzado Anterior/cirurgia , Fenômenos Biomecânicos , Parafusos Ósseos , Humanos , Teste de Materiais , Próteses e Implantes , Suínos , Tendões/transplante
13.
Am J Orthop (Belle Mead NJ) ; 44(1): 32-6, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25566554

RESUMO

We conducted a study to biomechanically compare 5 femoral hamstring tendon fixation devices commonly used in anterior cruciate ligament reconstruction. Quadrupled human semitendinosus-gracilis tendon grafts were fixed into porcine femurs using 5 separate fixation devices. For each device, 10 specimens were tested (1500-cycle loading test at 50-200 N). Specimens surviving the cyclic loading then underwent a single load-to-failure (LTF) test. Failure mode, stiffness, ultimate load, and rigidity were recorded. Two of 10 Delta screw (Arthrex), 10 of 10 Bio-TransFix (Arthrex), 10 of 10 Bone Mulch screw (Arthrotek), 10 of 10 EZLoc (Arthrotek), and 10 of 10 Zip Loop (Arthrotek) devices completed the 1500-cycle loading test. Residual displacement was lowest for Bio-TransFix (4.1 mm) followed by Bone Mulch (5.2 mm), EZLoc (6.4 mm), Zip Loop (6.8 mm), and Delta (8.2 mm). Mean stiffness was significantly (P < .001) higher for Bone Mulch (218 N/mm) than for Bio-TransFix (171 N/mm), EZLoc (122 N/mm), Zip Loop (105 N/mm), or Delta (84 N/mm). Mean LTF was significantly ( P < .001) higher for Bone Mulch (867 N) than for Zip Loop (615 N), Bio-TransFix (552 N), EZLoc (476 N), or Delta (410 N). The Bone Mulch screw demonstrated superior strength in the fixation of hamstring grafts in the femur. Bio-TransFix was close behind. The Delta screw demonstrated poor displacement, stiffness, and LTF. When used as the sole femoral fixation device, a device with low LTF, decreased stiffness, and high residual displacement should be used cautiously in patients undergoing aggressive rehabilitation.


Assuntos
Reconstrução do Ligamento Cruzado Anterior/instrumentação , Fêmur/cirurgia , Fixadores Internos , Tendões/cirurgia , Animais , Fenômenos Biomecânicos , Parafusos Ósseos , Fêmur/fisiopatologia , Xenoenxertos/fisiopatologia , Modelos Animais , Suínos , Tendões/fisiopatologia
14.
J Orthop Res ; 31(3): 407-12, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23070709

RESUMO

Rotator cuff pathology causes substantial pain/disability and health care costs. Cell-based tissue engineering offers promise for improved outcomes in tendon to bone healing. Cells from the tendon-bone interface were used here to amplify surgical defect healing in a rat model. Cells from tendon-to-bone interface of the rotator cuff were seeded in sponges and implanted into critical rotator cuff defects: Group I, control; II, surgical defect only; III, suture-repaired defect; IV, surgical defect, repair with sponge only; V, surgical defect, repair with sponge with cells. Three, 6-, and 12-week results were assessed for histologic features. At 3 weeks, histologic indices in Group V were significantly increased versus other treatment groups. Group V (12 weeks) showed significantly improved collagen organization versus other treatment groups; there was no difference in collagen organization in Group I versus V. In summary, increased cellularity, inflammation, vascularity, and collagen organization were present at 3 weeks; increased collagen organization at 12 weeks in Group V provides evidence for improved healing with cells. Data further support the utility of tendon-bone interface cells in rotator cuff healing.


Assuntos
Lesões do Manguito Rotador , Manguito Rotador/fisiologia , Traumatismos dos Tendões/terapia , Engenharia Tecidual/métodos , Cicatrização/fisiologia , Animais , Células Cultivadas , Colágeno/fisiologia , Modelos Animais de Doenças , Úmero/lesões , Úmero/fisiologia , Úmero/cirurgia , Ratos , Ratos Endogâmicos Lew , Regeneração/fisiologia , Manguito Rotador/cirurgia , Traumatismos dos Tendões/fisiopatologia , Traumatismos dos Tendões/cirurgia , Transplantes
15.
J Arthroplasty ; 27(6): 1183-9, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22386607

RESUMO

Knee osteoarthritis (OA) accounts for more functional disability of the lower extremity than any other disease. We recruited 18 patients with knee OA and 18 healthy age-, height-, mass-, and gender-matched control subjects to investigate the effects knee OA has on select spatial and temporal gait variables during a stair climbing task. No group-by-direction interaction was observed; however, significant effects did occur for group and direction. Specifically, patients with knee OA demonstrated less time in single support, greater time in double support, decreased step length, greater step width, less stride length, decreased total gait velocity, greater total time in support, and less total time in swing, compared with controls. Early-stage knee OA directly influences specific temporal and spatial gait characteristics during stair climbing.


Assuntos
Adaptação Fisiológica/fisiologia , Marcha/fisiologia , Osteoartrite do Joelho/fisiopatologia , Amplitude de Movimento Articular/fisiologia , Idoso , Fenômenos Biomecânicos , Estudos de Casos e Controles , Avaliação da Deficiência , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Tempo , Caminhada/fisiologia
16.
Med Sci Sports Exerc ; 43(3): 516-24, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-20689453

RESUMO

PURPOSE: Knee osteoarthritis (OA) is one of the most prevalent chronic lower extremity diseases, causing profound limitation of movement and ability to perform activities of daily living. The purpose of this study was to compare various hip, knee, and ankle joint kinematic variables between knee OA subjects and matched healthy controls during stair ascent and descent. METHODS: Eighteen subjects with knee OA (age = 60.2 ± 9.9 yr, mass = 90.3 ± 16.7 kg, height = 168.4 ± 9.9 cm) and 18 healthy matched controls (age = 60.3 ± 10.7 yr, mass = 81.1 ± 21.2 kg, height = 168.3 ± 11.9 cm) participated in the study. Subjects performed five ascending and descending trials on a custom-built staircase while their motion was captured three-dimensionally using an eight-camera optical video motion capture system. RESULTS: Significant group × direction interactions were found for average hip flexion angle at foot strike (P = 0.04), for average ankle adduction angle at foot strike (P = 0.01), and for peak ankle dorsiflexion angle during support (P = 0.05) and swing (P = 0.01). Specifically, knee OA and control subjects demonstrated greater hip flexion angle at foot strike and ankle dorsiflexion angle during swing but showed smaller ankle dorsiflexion angle during support during stair ascent compared with descent. Furthermore, compared with controls, knee OA patients demonstrated greater hip abduction at foot strike (-3.1° ± 3.9°) and smaller peak knee flexion during support (60.4° ± 5.0°) and swing (86.7° ± 5.4°). Time of peak hip abduction (34.2% ± 7.1%), hip flexion (7.0% ± 12.3%), knee flexion (69.8% ± 4.6%), dorsiflexion (51.4% ± 2.9%), and ankle adduction (37.3% ± 20.8%) during support occurred later in the gait cycle for knee OA patients. CONCLUSIONS: These data demonstrate that knee OA directly influences specific knee joint kinematics and induces kinematic alterations at the hip and ankle perhaps to compensate for the existing knee joint pathology.


Assuntos
Articulação do Joelho/fisiopatologia , Osteoartrite do Joelho/fisiopatologia , Atividades Cotidianas , Idoso , Articulação do Tornozelo/fisiopatologia , Fenômenos Biomecânicos/fisiologia , Estudos de Casos e Controles , Feminino , Articulação do Quadril/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Amplitude de Movimento Articular/fisiologia
17.
Am J Sports Med ; 38(7): 1448-55, 2010 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-20442324

RESUMO

BACKGROUND: Techniques for ulnar collateral ligament (UCL) reconstruction have evolved since its original description. HYPOTHESIS: Ulnar collateral ligament reconstruction using the ZipLoop for ulnar-sided fixation, as combined with the humeral docking technique supplemented with an interference screw, will restore valgus stability similar to that of the Jobe technique and the native ligament. STUDY DESIGN: Controlled laboratory study. METHODS: Kinematic testing was performed on 8 matched pairs of cadaver elbows with an electromagnetic tracking system through an arc of motion for the intact, disrupted, and reconstructed states of the UCL in an unloaded and loaded condition. From each pair, the docking technique using the ZipLoop for ulnar fixation and humeral docking technique supplemented with an interference screw and the traditional Jobe technique were performed with matched gracilis allograft tendons. After kinematic testing, both reconstruction groups were tested to failure at 70 degrees of flexion. RESULTS: Kinematic results for the unloaded condition showed that both reconstruction techniques significantly overcorrected (less valgus angulation) the specimens between 40 degrees and 120 degrees of flexion when compared with the intact ligament (all P values < .027). Under loaded conditions, the ulnar trajectories for both reconstruction techniques exhibited significantly greater valgus angulation (undercorrection) at 20 degrees of flexion (Jobe, P = .0084; ZipLoop, P = .0289) when compared with the intact ligament but were not significantly different over the remaining arc of motion. Failure testing resulted in no significant statistical difference between the 2 reconstruction groups. Failure testing demonstrated that humeral tunnel egress, midsubstance elongation, and ulnar tunnel egress of the ligament were similar between the reconstruction techniques. CONCLUSION: The docking technique using the ZipLoop for ulnar-sided fixation is biomechanically equivalent to the Jobe technique for UCL reconstruction. Both reconstruction techniques restore valgus stability similar to that of the native UCL ligament. CLINICAL RELEVANCE: This modification in the docking technique restores elbow kinematics while eliminating the risk of ulnar bone bridge fracture, and it allows for retensioning of the graft after cortical fixation.


Assuntos
Ligamentos Colaterais/cirurgia , Articulação do Cotovelo/cirurgia , Dispositivos de Fixação Ortopédica , Procedimentos Ortopédicos , Procedimentos de Cirurgia Plástica , Ulna/cirurgia , Adolescente , Adulto , Fenômenos Biomecânicos , Parafusos Ósseos , Articulação do Cotovelo/fisiologia , Feminino , Humanos , Instabilidade Articular/cirurgia , Masculino , Pessoa de Meia-Idade , Tendões/cirurgia , Adulto Jovem
18.
J Surg Res ; 162(1): 148-52, 2010 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19783006

RESUMO

BACKGROUND: Effectiveness of acellular human dermis (AHD) as an alternative to synthetic mesh in contaminated fields has been described. Cellular migration after implantation and corresponding strength of attachment is not well documented. Our aim is to correlate AHD vascularization, fibroblast migration, and strength of attachment with presence of inflammatory cells in clean and contaminated fields. MATERIALS AND METHODS: Lewis rats were randomized to a control and three experimental groups. AHD was placed as an onlay over the intact abdominal wall. Experimental groups (n=72) were exposed to Staphylococcus aureus at 1 x 10(4), 1 x 10(5), or 1 x 10(6) by direct application; controls (n=12) were not exposed. At 5 and 28 d, abdominal walls were explanted and tissue ingrowth assessed via tensiometry measuring energy (E) and max stress (MS) at the AHD-tissue interface. Vascularity, fibroblast migration, and inflammatory cell migration were compared using light microscopy. RESULTS: Shear strength reported as energy and max stress were significantly greater at 28 versus 5 d in all experimental groups, remaining unchanged in controls. Plasma cells and histiocytes significantly increased in all groups; macrophages increased in experimental groups only. Vascular ingrowth increased significantly in all groups; fibroblast migration was greater in controls and 1 x 10(6) exposed group only. CONCLUSIONS: Contamination of AHD results in inflammatory cell influx and a surprising increase in shear strength. Interestingly, shear strength does not increase without contamination. Inflammation stimulates vascular ingrowth, but not equally significant fibroblast migration. Longer survivals are required to determine if energy and max stress of controls increase, and fibroblast migration follows vascular ingrowth.


Assuntos
Bioprótese/microbiologia , Colágeno , Animais , Movimento Celular , Fibroblastos/fisiologia , Herniorrafia , Humanos , Masculino , Neovascularização Fisiológica , Distribuição Aleatória , Ratos , Ratos Endogâmicos Lew
19.
Surg Endosc ; 23(4): 800-7, 2009 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-18830746

RESUMO

INTRODUCTION: The addition of staple-line reinforcements on circular anastomoses has not been well studied. We histologically and mechanically analyzed circular- stapled anastomoses with and without bioabsorbable staple-line reinforcement (SeamGuard, W. L. Gore & Associates, Flagstaff, AZ) in a porcine model. METHODS: Gastrojejunal anastomoses were constructed using a #25 EEA Proximate ILS (Ethicon Endo-Surgery, Cincinnati, OH) mechanical stapling device with and without Bioabsorbable SeamGuard (BSG). Gastrojejunal anastomoses were resected acutely and at 1 week, and burst-pressure testing and histological analysis were performed. Standardized grading systems for inflammation, collagen deposition, vascularity, and serosal inflammation were used to compare the two anastomosis types. RESULTS: Acute burst pressures were significantly higher with BSG than with staples alone (1.37 versus 0.39 psi, p=0.0075). Burst pressures at 1 week were significantly lower with BSG than with staples alone (2.24 versus 3.86 psi, p=0.0353); however, both readings were above normal physiologic intestinal pressures. There was no statistical difference in inflammation (13.4 versus 15.6, p=0.073), width of mucosa (3.2 mm versus 3.2 mm, p=0.974), adhesion formation (0 versus 0.5, p=0.575), number of blood vessels (0.5 versus 1.0, p=0.056), or serosal inflammation (2.0 versus 1.0, p=0.27) between the stapled anastomoses and those buttressed with BSG. Stapled-only anastomoses had statistically more collagen (2.0 versus 1.0, p=0.005) than the anastomoses supported with BSG. CONCLUSIONS: The addition of BSG as a staple-line reinforcement acutely improves the burst strength of a circular anastomosis but not at 1 week. At 1 week, a decrease in collagen content with the BSG-buttressed stapled anastomosis was the only difference in the histologic parameters studied with no difference in vascularity, adhesions, or inflammation. The long-term effect of BSG on anastomotic strength or scarring is yet to be determined. The clinical implications may include decreased stricture formation and also decreased strength at anastomoses.


Assuntos
Materiais Biocompatíveis , Jejuno/cirurgia , Estômago/cirurgia , Grampeamento Cirúrgico/instrumentação , Suturas , Anastomose em-Y de Roux/métodos , Animais , Colágeno/metabolismo , Modelos Animais de Doenças , Desenho de Equipamento , Feminino , Mucosa Intestinal/metabolismo , Mucosa Intestinal/patologia , Jejuno/patologia , Jejuno/fisiopatologia , Pressão , Estômago/patologia , Estômago/fisiopatologia , Suínos
20.
J Arthroplasty ; 23(6): 873-8, 2008 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-18534544

RESUMO

Cementing polyethylene liners into well-fixed metal shells at revision total hip arthroplasty is an accepted technique. Previous studies have tested the initial strength of this construct, but none have tested the construct under physiologic and abnormal loading conditions. The current study examines liner-shell performance under these conditions. In addition, this study quantitates whether hand-modified regular liners or liners designed for cementation with integrated cement spacers, which provide an even cement mantle, perform better. Cyclic loads of up to 4000 N for 500,000 cycles followed by 2000 N for 200,000 cycles of edge loading were used. The liners with integrated spacers demonstrated higher lever-out moments and statistically significant increase in tear-out loads.


Assuntos
Artroplastia de Quadril/instrumentação , Cimentos Ósseos , Prótese de Quadril , Metais , Polietileno , Fenômenos Biomecânicos , Articulação do Quadril/fisiologia , Articulação do Quadril/cirurgia , Humanos , Modelos Biológicos , Desenho de Prótese , Reoperação , Suporte de Carga/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA