Phys Med Biol ; 65(1): 015012, 2020 01 13.
Artigo em Inglês | MEDLINE | ID: mdl-31775123

RESUMO

Improvements in dosimetry in preclinical radiation research facilitate the application of results to the newest radiotherapy techniques, reducing gaps that hinder translation. Currently, guidelines for small-field kV photon dosimetry of small animal irradiators have not been published, and most of the publications are based on radiochromic film dosimetry. In this study, we evaluated the performance of four detectors, three ionization chambers (ICs): (PTW Advanced Markus, PTW Semiflex 31010, PTW PinPoint-3D 31016) and one solid-state detector (PTW 60017 unshielded Diode E) regarding their suitability for relative dosimetry of the small animal radiation research platform SARRP (220 kVp). The measurements were performed in a high-resolution 3D scanning phantom, centering the detectors in the field following the in-plane and cross-plane profiles method at two depths. Depth dose curves (PDDs) and profiles were measured in water for field sizes ranging from 40 × 40 mm2 to 5 × 5 mm2. Quantitative analysis was performed through global and local dose differences (DDs) between the PDDs and the Advanced Markus parallel plate IC data and through the gamma index (γ) criteria for profiles compared against data from EBT3 films provided by the manufacturer. Compared to the Advanced Markus IC, the PDD results suggest that PinPoint-3D is suitable for depth measurements at this beam quality, even near the surface, with agreements better than 1%. Semiflex 31010 was accurate to within 1.5% for measurements deeper than 5 mm. Diode E showed a dramatic DD and should not be recommended for the field sizes and kVp evaluated in this study. In agreement with γ analyses, PinPoint-3D and Diode E are good candidates for profile measurements of field sizes from 40 × 40 mm2 to 10 × 10 mm2. For 5 × 5 mm2 profiles, only Diode E showed good results, making it a recommended detector for profile measurements.


Assuntos
Dosimetria Fotográfica/instrumentação , Dosimetria Fotográfica/métodos , Imagens de Fantasmas , Fótons , Animais , Água/química
2.
PLoS One ; 9(12): e115155, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25521914

RESUMO

High dose rate brachytherapy (HDR) using 192Ir sources is well accepted as an important treatment option and thus requires an accurate dosimetry standard. However, a dosimetry standard for the direct measurement of the absolute dose to water for this particular source type is currently not available. An improved standard for the absorbed dose to water based on Fricke dosimetry of HDR 192Ir brachytherapy sources is presented in this study. The main goal of this paper is to demonstrate the potential usefulness of the Fricke dosimetry technique for the standardization of the quantity absorbed dose to water for 192Ir sources. A molded, double-walled, spherical vessel for water containing the Fricke solution was constructed based on the Fricke system. The authors measured the absorbed dose to water and compared it with the doses calculated using the AAPM TG-43 report. The overall combined uncertainty associated with the measurements using Fricke dosimetry was 1.4% for k = 1, which is better than the uncertainties reported in previous studies. These results are promising; hence, the use of Fricke dosimetry to measure the absorbed dose to water as a standard for HDR 192Ir may be possible in the future.


Assuntos
Braquiterapia/normas , Compostos Ferrosos/efeitos da radiação , Radioisótopos de Irídio/uso terapêutico , Radiometria/métodos , Soluções/efeitos da radiação , Absorção de Radiação , Algoritmos , Braquiterapia/métodos , Estudos de Viabilidade , Dosagem Radioterapêutica/normas , Água/química
3.
In. Schiabel, Homero; Slaets, Annie France Frère; Costa, Luciano da Fontoura; Baffa Filho, Oswaldo; Marques, Paulo Mazzoncini de Azevedo. Anais do III Fórum Nacional de Ciência e Tecnologia em Saúde. Säo Carlos, s.n, 1996. p.261-262, tab, graf.
Monografia em Português | LILACS | ID: lil-236346

RESUMO

Foi testada a repetibilade da câmara de ionização tipo Radeal para radiodiagnóstico após ter sido calibrada no laboratório primário da Alemanha / PTB. A resposta durante toda prática experimental manteve-se dentro do limite de repetibilidade de 0,1 por cento.


Abstract - Before calibration in Germany Primary Laboratory / PTB the Radcal diagnostic ionization chamber repeatability was tested in LNMRI / Brazil. Response of the chamber during experiment for repeatability demonstrate a variance in the range of O, 1 %


Assuntos
Calibragem , Radiografia , Radiação Ionizante , Brasil