1.
Cell Commun Signal ; 22(1): 353, 2024 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-38970072

RESUMO

Copper is a crucial trace element that plays a role in various pathophysiological processes in the human body. Copper also acts as a transition metal involved in redox reactions, contributing to the generation of reactive oxygen species (ROS). Under prolonged and increased ROS levels, oxidative stress occurs, which has been implicated in different types of regulated cell death. The recent discovery of cuproptosis, a copper-dependent regulated cell death pathway that is distinct from other known regulated cell death forms, has raised interest to researchers in the field of cancer therapy. Herein, the present work aims to outline the current understanding of cuproptosis, with an emphasis on its anticancer activities through the interplay with copper-induced oxidative stress, thereby providing new ideas for therapeutic approaches targeting modes of cell death in the future.


Assuntos
Antineoplásicos , Cobre , Estresse Oxidativo , Cobre/metabolismo , Humanos , Estresse Oxidativo/efeitos dos fármacos , Antineoplásicos/farmacologia , Animais , Espécies Reativas de Oxigênio/metabolismo , Neoplasias/metabolismo , Neoplasias/tratamento farmacológico , Neoplasias/patologia
2.
Polymers (Basel) ; 16(9)2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38732740

RESUMO

Polyetheretherketone (PEEK), an organic thermoplastic polymer, has gained interest in dentistry due to its excellent mechanical strength, flexibility, and biocompatibility. Furthermore, the ability to utilize CAD/CAM in the fabrication of PEEK enhances accuracy, reliability, and efficiency while also saving time. Hence, several orthodontic studies have explored the utilization of PEEK in various applications, such as archwires, brackets, fixed lingual retainers, palatal expansion devices, transpalatal arches, Tübingen palatal plates, different types of space maintainers, mini-implant insertion guides, and more. However, a complete systematic review of the available data comparing the performance of PEEK with traditional orthodontic materials has not yet been conducted. Therefore, this systematic review seeks to assess if PEEK material meets the required mechanical criteria to serve as an alternative to conventional orthodontic appliances. To ensure clarity and precision, this review will specifically concentrate on fixed appliances. This systemic review followed the PRISMA guidelines and utilized databases including PubMed/MEDLINE, Embase, Springer, Web of Science, and Wiley. Searches were restricted to English language articles from January 2013 to February 2024. Keywords such as "Polyetheretherketone" or "PEEK" and "Orthodontic" or "Orthodontic device" or "Orthodontic materials" were employed across all databases. Nine studies were incorporated, covering orthodontic archwires, brackets, and fixed lingual retainers. Based on the reviewed literature, PEEK demonstrates promising potential in orthodontic fixed appliances, offering advantages in force delivery, friction reduction, and aesthetic appeal. Further research is needed to fully explore its capabilities and optimize its application in clinical practice.

3.
J Dent ; 145: 105023, 2024 06.
Artigo em Inglês | MEDLINE | ID: mdl-38670331

RESUMO

OBJECTIVES: Multilayer monolithic zirconia (M-Zr) crowns can be engineered to achieve gradational translucency and color intensity. However, this modification may compromise the mechanical strength, raising concerns regarding the ability of M-Zr crowns to withstand occlusal stresses. The effects of M-Zr crown thickness on translucency and ability to endure occlusal forces were investigated at different tooth positions (incisors, premolars, and molars). The objective was to determine the minimal thickness of M-Zr crowns used in tooth preparation to meet aesthetic and functional demands. METHODS: M-Zr samples (Vita A1) with four thicknesses (0.5, 1.0, 1.5, and 2.0 mm) were prepared and subjected to translucency testing using a digital colorimeter by 3-third and 9-square division methods. Crown-shaped M-Zr samples with three thicknesses (1.0, 1.5, and 2.0 mm) and three tooth positions (incisor, premolar, and molar) were digitally designed, and 2.0 mm metal abutments were fabricated. The samples were bonded to the abutments; their fracture characteristics were evaluated using a universal testing machine, and their fracture surfaces examined using an optical microscope. Statistical analyses included the Shapiro-Wilk test, Pearson correlation, and one-way and two-way ANOVA with a post hoc Tukey HSD test (α = 0.05). RESULTS: Color analysis results revealed a significant negative correlation between thickness and translucency (r < -0.96, P < 0.01), with the highest values in the incisal region. Cross-sectional profiles confirmed the uniform thickness and morphology of the digitally designed M-Zr crowns. The results of fracture strength analysis showed position-dependent variability, a strong positive correlation with thickness (r > 0.96, P < 0.01), and fracture strengths consistently exceeding 1200 N across all tooth positions. Fracture patterns indicated that thinner crowns at the incisors and molars were more prone to cracking, whereas those at the premolars demonstrated significantly higher strength (4872.51 N, P < 0.05), only with crack or even no fracture occurring at 2.0 mm. CONCLUSIONS: Thickness significantly influenced both the translucency and fracture strength of M-Zr, with the tooth position playing an additional role, albeit to a lesser extent. Although thinner crowns exhibited lower strength at each tooth position, even at a thickness of 1.0 mm, fracture strength exceeding 1200 N was maintained, surpassing the typical occlusal forces. Thus, it can be asserted that M-Zr crowns with a minimum thickness of 1.0 mm can meet both aesthetic and functional requirements.


Assuntos
Dente Pré-Molar , Coroas , Materiais Dentários , Planejamento de Prótese Dentária , Teste de Materiais , Zircônio , Zircônio/química , Humanos , Materiais Dentários/química , Propriedades de Superfície , Dente Molar , Análise do Estresse Dentário , Falha de Restauração Dentária , Cor , Dente Suporte , Força de Mordida , Incisivo , Porcelana Dentária/química , Estresse Mecânico
4.
J Dent Sci ; 19(2): 919-928, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38618085

RESUMO

Background/purpose: The chemo-mechanical caries-removal technique is known to offer advantages of selective dentin caries treatment while leaving healthy dental tissues intact. However, current sodium hypochlorite based reagents usually excessively damage dentin collagen. Therefore, the purpose of this study was to develop a novel chemo-mechanical caries-removal system to preserve the collagen network for subsequent prosthetic restorations. Materials and methods: The calfskin-derived collagen was chosen as a model system to investigate the dissolution behavior of collagen under different operating conditions of chemical-ultrasonic treatment systems. The molecular weight, triple-helix structure, the morphology, and functional group of collagen after treatment were investigated. Results: Various concentrations of sodium hypochlorite or zinc chloride together with ultrasonic machinery were chosen to investigate. The outcomes of circular dichroism (CD) spectra demonstrated stability of the triple-helix structure after treatment of a zinc chloride solution. In addition, two apparent bands at molecular weights (MWs) of 130 and 121 kDa evidenced the stability of collagen network. The positive 222 nm and 195 nm negative CD absorption band indicated the existence of a triple-helix structure for type I collagen. The preservation of the morphology and functional group of the collagen network on the etched dentin surface were investigated by in vitro dentin decalcification model. Conclusion: Unlike NaOCl, the 5 wt% zinc chloride solution combined with ultra-sonication showed dissolution rather than denature as well as degradation of the dentin collagen network. Additional in vivo evaluations are needed to verify its usefulness in clinical applications.

5.
Dent Mater J ; 43(3): 394-399, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38599831

RESUMO

The purpose of this study was to construct deep learning models for more efficient and reliable sex estimation. Two deep learning models, VGG16 and DenseNet-121, were used in this retrospective study. In total, 600 lateral cephalograms were analyzed. A saliency map was generated by gradient-weighted class activation mapping for each output. The two deep learning models achieved high values in each performance metric according to accuracy, sensitivity (recall), precision, F1 score, and areas under the receiver operating characteristic curve. Both models showed substantial differences in the positions indicated in saliency maps for male and female images. The positions in saliency maps also differed between VGG16 and DenseNet-121, regardless of sex. This analysis of our proposed system suggested that sex estimation from lateral cephalograms can be achieved with high accuracy using deep learning.


Assuntos
Aprendizado Profundo , Humanos , Feminino , Masculino , Estudos Retrospectivos , Cefalometria/métodos , Adulto , Determinação do Sexo pelo Esqueleto/métodos , Curva ROC
6.
ACS Nano ; 2024 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-38315422

RESUMO

Absorption of photons in atomically thin materials has become a challenge in the realization of ultrathin, high-performance optoelectronics. While numerous schemes have been used to enhance absorption in 2D semiconductors, such enhanced device performance in scalable monolayer photodetectors remains unattained. Here, we demonstrate wafer-scale integration of monolayer single-crystal MoS2 photodetectors with a nitride-based resonant plasmonic metasurface to achieve a high detectivity of 2.58 × 1012 Jones with a record-low dark current of 8 pA and long-term stability over 40 days. Upon comparison with control devices, we observe an overall enhancement factor of >100; this can be attributed to the local strong EM field enhanced photogating effect by the resonant plasmonic metasurface. Considering the compatibility of 2D semiconductors and hafnium nitride with the Si CMOS process and their scalability across wafer sizes, our results facilitate the smooth incorporation of 2D semiconductor-based photodetectors into the fields of imaging, sensing, and optical communication applications.

7.
J Dent Sci ; 19(1): 32-38, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38303863

RESUMO

Background/purpose: Polyetheretherketone (PEEK) is a highly sought-after thermoplastic due to its exceptional mechanical properties and biocompatibility. However, bonding PEEK to indirect composite resin (ICR) or denture-based resin (DBR) can be challenging. Laser engraving technology has shown potential to improve bonding for other materials; thus, this study aims to evaluate its effectiveness for PEEK. Materials and methods: The experiment involved preparing ingot-shaped PEEK samples, which were then categorized into four groups based on the treatment method employed: without treatment, air abrasion, sulfuric acid etching, and laser engraving (LS). Subsequently, the samples were bonded to ICR or DBR, and their shear bond strength (SBS) was tested with or without thermocycling using a universal testing machine. Furthermore, the failure mode was observed, with statistical analyses conducted to compare the results. Results: The grid-like microslit structure of LS group displayed the highest SBS for bonding PEEK to ICR or DBR (P < 0.05). During the bonding of PEEK to ICR, resin residue and penetration into the microslits were frequently observed in the LS group, indicating cohesive failure. However, when PEEK was bonded to DBR, mixture failure was frequently observed without thermocycling. After thermocycling, only the LS group showed cohesive failure, while the majority of specimens exhibited mixture failure. Conclusion: Laser engraving significantly improves the SBS between PEEK and both ICR and DBR. Furthermore, it was observed that resin had penetrated the microslits, indicating that laser engraving has great potential as a surface treatment method.

8.
J Prosthodont Res ; 68(3): 466-473, 2024 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-38220161

RESUMO

PURPOSE: This study aimed to investigate the retentive force and deformation of double Akers' polyetherketoneketone (PEKK) clasps on removable partial dentures (RPDs) with varying designs and undercut depths. METHODS: Thirty double Akers' PEKK clasps with two different widths and heights (Groups I and II) were fabricated using computer-aided design and computer-aided manufacturing (CAD/CAM). Each design was further subdivided (n = 5) into three undercut depths (0.25, 0.50, and 0.75 mm). The retentive force of the clasps was measured after 10 years of clinical use (15,000 insertion/removal cycles), and the deformation of the clasp tips was analyzed before and after cycling. RESULTS: Clasps with 0.50-mm and 0.75-mm undercut depths exhibited greater initial retentive forces (3.15-3.51 N) compared to those in the 0.25-mm undercut group (2.40-2.80 N). Group I maintained consistent retentive forces over the cycles (P = 0.345), whereas Group II showed declining forces after the initial use (P < 0.003). In both groups, the 0.50-mm undercut exhibited a greater retentive force than the 0.25-mm (P < 0.001 and P < 0.004, respectively), with no significant differences between the 0.50-mm and 0.75-mm undercut depths. Despite a lower initial retentive force, the 0.25-mm undercut showed less deformation and clasp tip wear. CONCLUSIONS: The PEKK clasps did not exhibit significantly reduced retentive forces or permanent deformations after 15,000 fatigue cycles. These results suggest that the PEKK polymer displays superior mechanical properties as an esthetic clasp material, and clasps with 0.50-mm and 0.75-mm undercut depths are recommended for long-term clinical use.


Assuntos
Desenho Assistido por Computador , Grampos Dentários , Planejamento de Dentadura , Prótese Parcial Removível , Cetonas , Planejamento de Dentadura/métodos , Polímeros , Retenção de Dentadura , Benzofenonas , Teste de Materiais , Técnicas In Vitro , Análise do Estresse Dentário
9.
J Prosthet Dent ; 131(2): 291.e1-291.e9, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38057199

RESUMO

STATEMENT OF PROBLEM: The retentive force and deformation of milled polyetheretherketone (PEEK) and polyetherketoneketone (PEKK) removable partial denture (RPD) frameworks are not well understood. PURPOSE: The purpose of this in vitro study was to assess the retentive force and deformation of PEEK and PEKK Akers clasps with different designs and undercut depths. MATERIAL AND METHODS: A master model containing the first and second molar abutments was used to design Akers clasps of different cross-sectional dimensions, undercut depths (0.5 and 0.75 mm), and materials. The components of the removable partial denture framework also included an occlusal rest and were manufactured using a milling machine (n=5). The fatigue resistance of the Akers clasps was measured before and after deformation regarding the retentive forces. RESULTS: The PEEK2-U50 clasp had the largest retentive force with no significant difference among all groups before and after the insertion and removal cycle. In addition, the increased cross-sectional dimensions of the design resulted in significant differences in retentive forces between the PEEK1 and PEEK2 groups and between the PEEK and PEKK materials. CONCLUSIONS: Increasing the clasp's cross-sectional dimensions significantly impacted retentive forces, especially between different PEEK groups and between PEEK and PEKK materials.


Assuntos
Benzofenonas , Ligas de Cromo , Prótese Parcial Removível , Polímeros , Estudos Transversais , Retenção de Dentadura , Polietilenoglicóis , Cetonas , Grampos Dentários
10.
J Prosthodont Res ; 68(2): 319-325, 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-37574275

RESUMO

PURPOSE: Polyetheretherketone (PEEK) is a new polymeric material that has received significant attention in dentistry because of its mechanical properties, biocompatibility, and aesthetics. However, the bonding performance of PEEK to other materials is not preferable. This study aimed to analyze the variations in the surface characteristics of PEEK under the chemical action of primers containing different functional monomers or polymers and to evaluate the bonding performance of PEEK and dental cement. METHODS: Disk-shaped PEEK samples were prepared by dental milling, blasting with alumina oxide, and covering with primers containing functional monomers or polymers. The surface characteristics of the samples were analyzed by microscopy and spectroscopy. The shear bond strength (SBS) between PEEK and dental cement, with and without thermocycling, was tested using a universal testing machine. Finally, the data were statistically analyzed and compared. RESULTS: Functional monomers or polymers were successfully bonded to the surface of PEEK. This treatment significantly improved its hydrophilicity and surface free energy (P < 0.05). The primer containing pentaerythritol triacrylate had the highest SBS without thermocycling (13.89 MPa). Meanwhile, the primers containing urethane dimethacrylate (UDMA) and methyl methacrylate (MMA) (abbreviated as the HC group) showed the highest SBS and lowest reduction (25.51%) after thermocycling. Notably, all the testing groups achieved the ISO10477 standard of 5 MPa. After thermocycling, adhesive failure accounted for the largest proportion of failures in all the groups except the HC group. CONCLUSIONS: The chemical priming treatment can significantly improve the SBS of PEEK and dental cement. Moreover, a primer containing both UDMA and MMA can provide improved bonding for PEEK materials.


Assuntos
Colagem Dentária , Metacrilatos , Poliuretanos , Colagem Dentária/métodos , Cimentos de Resina/química , Polímeros , Benzofenonas , Polietilenoglicóis , Cetonas , Propriedades de Superfície , Teste de Materiais , Resistência ao Cisalhamento , Análise do Estresse Dentário
11.
Heliyon ; 9(12): e23046, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38076041

RESUMO

Statement of problem: The relation between cement color and abutment substrate material and the corresponding effect on the color accuracy of high-transparency pre-colored zirconia (HT-Zr) remains unclear. Purpose: This in-vitro study aimed to investigate the difference in color accuracy when the HT-Zr is bonded to different materials-based substrates with differently colored resin cement. Materials and methods: Vita A1 shade HT-Zr with 1 mm thickness was used as the testing sample. The samples were first placed on zirconia (ZR), tooth color resin (CR), and metallic (MT) abutment substrates. Subsequently, four differently colored cements (translucent (TR), bleach, opaque, and A2 shade (A2)) were used for bonding HT-Zr onto the substrate, and the non-bonded group was used as the control group (CG). There were 15 groups in total (n = 10 per group). A digital colorimeter was used to obtain Commission Internationale de l'Eclairage (CIELab) color parameters. The translucency parameter (TP00) of the substrate and sample, as well as color difference (ΔE00) and chroma (C) between the different groups were calculated. Additionally, the ΔE00 and TP00 were compared with the moderately unacceptable match of ΔE00 = 3.6. The statistical analysis was conducted using ANOVA and Tukey HSD post-hoc test (α = 0.05). Results: HT-Zr exhibited high translucency (TP00 = 11.02 ± 0.18), and the mean ΔE00 of the testing samples ranged between 2.18 ± 0.20 and 13.14 ± 0.31. The ZR-CG and MT-A2 groups showed the highest and lowest lightness separately. The CR-CG group exhibited the highest C, and the ΔE00 was lower than that of 3.6. The MT-TR group showed the lowest C and the highest ΔE00. The inter-group comparison revealed that the ΔE00 for different cement is mostly lower than the acceptable color match of 1.0; moreover, the ΔE00 for all the substrates, excluding the CG group, is higher than 3.6. Conclusions: The abutment substrate materials and the cement color should be considered with caution when using HT-Zr, with the effect of abutment substrate materials being more apparent in color accuracy. HT-Zr restorations are not recommended for discolored or bleached abutments but only for natural-colored abutments to achieve the optimal color appearance.

12.
Biomedicines ; 11(11)2023 Nov 08.
Artigo em Inglês | MEDLINE | ID: mdl-38001996

RESUMO

This review examines the modifying factors affecting bond strength in various bonding scenarios, particularly their relevance to the longevity of dental restorations. Understanding these factors is crucial for improving clinical outcomes in dentistry. Data were gathered from the PubMed database, ResearchGate, and Google Scholar resources, covering studies from 1992 to 2022. The findings suggest that for dentin-resin bonds, minimizing smear layers and utilizing MMP inhibitors to prevent hybrid layer degradation are essential. In the case of resin-resin bonds, reversing blood contamination is possible, but preventing saliva contamination is more challenging, underscoring its critical importance during clinical procedures. Additionally, while pretreatment on ceramics has minimal impact on bond strength, the influence of specific colorings should be carefully considered in treatment planning. This comprehensive review highlights that although established practices recognize significant bond strength factors, ongoing research provides valuable insights to enhance the clinical experience for patients. Once confirmed through rigorous experimentation, these emerging findings should be swiftly integrated into dental practice to improve patient outcomes.

13.
J Dent Sci ; 18(4): 1804-1811, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37799918

RESUMO

Background/purpose: Polyetheretherketone (PEEK) is known for its strength, flexibility, biocompatibility, and potential as a replacement for metals in dental appliances; however, uncertainty remains about the mechanical characteristics and dimensions of PEEK-made orthodontic fixed lingual retainers (FLRs). This study aimed to determine the optimal shape of PEEK-made orthodontic FLRs using the finite element method (FEM) and the three-point bending test (TPBT). Materials and methods: Seventy-five three-dimensional PEEK rod-shaped models were created, which included five thicknesses (0.4, 0.6, 0.8, 1.0, and 1.2 mm), five widths (0.7, 0.9, 1.1, 1.3, and 1.5 mm), and three cross-sectional shapes (rectangular, oval, and hemielliptical). A 0.9-mm (0.036-inch) stainless steel wire (SSW) was used as a control and the FEM was used to determine six optimal dimensions among the PEEK models. The selected models were then fabricated and subjected, along with the SSW, to the experimental TPBT to assess their mechanical responses against lingual and biting pressures. Results: The FEM analysis revealed that Von Mises stresses on the PEEK models decreased with an increase in width and thickness. Six optimal shapes of PEEK models were chosen based on acceptable lingual and biting stresses as well as patient comfort compared to the SSW. Furthermore, PEEK models showed significantly lower deformation during the 3.1-mm deflection test than did the SSW, while no notable differences were observed among different sizes of PEEK models. The hemielliptical PEEK model with a thickness of 1.0 mm and width of 1.5 mm was found to be mechanically robust enough to withstand lingual forces, while none of the PEEK models, including the SSW, were able to resist biting forces. Conclusion: Within the limitations of this in vitro study, PEEK-made orthodontic FLRs with a hemielliptical cross-sectional shape and a thickness-to-width ratio of 1.0:1.5 would be suitable for use as orthodontic FLRs.

14.
Nano Lett ; 23(24): 11387-11394, 2023 Dec 27.
Artigo em Inglês | MEDLINE | ID: mdl-37906586

RESUMO

With a growing demand for detecting light at the single-photon level in various fields, researchers are focused on optimizing the performance of superconducting single-photon detectors (SSPDs) by using multiple approaches. However, input light coupling for visible light has remained a challenge in the development of efficient SSPDs. To overcome these limitations, we developed a novel system that integrates NbN superconducting microwire photon detectors (SMPDs) with gap-plasmon resonators to improve the photon detection efficiency to 98% while preserving all detector performance features, such as polarization insensitivity. The plasmonic SMPDs exhibit a hot-belt effect that generates a nonlinear photoresponse in the visible range operated at 9 K (∼0.64Tc), resulting in a 233-fold increase in phonon-electron interaction factor (γ) compared to pristine SMPDs at resonance under CW illumination. These findings open up new opportunities for ultrasensitive single-photon detection in areas like quantum information processing, quantum optics, imaging, and sensing at visible wavelengths.

15.
Cancers (Basel) ; 15(19)2023 Sep 30.
Artigo em Inglês | MEDLINE | ID: mdl-37835505

RESUMO

Oral submucous fibrosis (OSF) stands as a progressive oral ailment, designated as a potentially malignant disorder. OSF has gained widespread recognition as a significant precursor to malignant transformation. In the pursuit of dependable, straightforward, and non-invasive diagnostic measures for the early detection of oral malignant progression, research has delved into potential diagnostic biomarkers of OSF. This comprehensive review delves into current investigations that explore the correlation between various biomarkers and OSF. The molecular biomarkers of OSF are categorized based on cytology and sampling methods. Moreover, this review encompasses pertinent studies detailing how these biomarkers are acquired and processed. Within this scope, we scrutinize four potential biomarkers that hold the promise of facilitating the development of diagnostic tools for detecting early-stage OSF.

16.
Biomedicines ; 11(10)2023 Oct 14.
Artigo em Inglês | MEDLINE | ID: mdl-37893162

RESUMO

Periodontitis involves the inflammation of the periodontal tissue, leading to tissue loss, while coronavirus disease 2019 (COVID-19) is a highly transmissible respiratory disease caused by the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), which is amplified by poor systemic health. Key facilitators of SARS-CoV-2's entry into host cells are angiotensin-converting enzyme 2 (ACE2) and transmembrane serine protease 2 (TMPRSS2). This review reveals that periodontal pockets can serve as a hotspot for virus accumulation, rendering surrounding epithelia more susceptible to infection. Given that ACE2 is expressed in oral mucosa, it is reasonable to suggest that poor periodontal health could increase the risk of COVID-19 infection. However, recent studies have not provided sufficient evidence to imply a significant effect of COVID-19 on periodontal health, necessitating further and more long-term investigations. Nevertheless, there are hypotheses linking the mechanisms of the two diseases, such as the involvement of interleukin-17 (IL-17). Elevated IL-17 levels are observed in both COVID-19 and periodontitis, leading to increased osteoclast activity and bone resorption. Lastly, bidirectional relationships between periodontitis and systemic diseases like diabetes are acknowledged. Given that COVID-19 symptoms may worsen with these conditions, maintaining good oral health and managing systemic diseases are suggested as potential ways to protect against COVID-19.

17.
Polymers (Basel) ; 15(18)2023 Sep 06.
Artigo em Inglês | MEDLINE | ID: mdl-37765524

RESUMO

Polyetheretherketone (PEEK) is widely used in dentistry owing to its exceptional properties, including its natural appearance; however, existing surface treatment methods for bonding PEEK have limitations. Autofocus laser cutters, known for their precise engraving and cutting capabilities, offer potential for surface treatment of PEEK; thus, the objective of this study was to investigate the creation of laser groove structures on PEEK to enhance its bonding capability with dental resin cement. A dental computer-aided design and manufacturing system was used to fabricate PEEK samples, and three groove patterns (circle, line, and grid) were generated on PEEK surfaces, with air-abrasion used as the control group. The surface characteristics, cell viability, and bond strength were evaluated, and the data were statistically analyzed using one-way analysis of variance and post hoc Tukey's tests (α = 0.05). Laser-treated PEEK exhibited a uniform texture with a groove depth of approximately 39.4 µm, hydrophobic properties with a contact angle exceeding 90°, a surface roughness of 7.3-12.4 µm, consistent topography, and comparable cell viability compared with untreated PEEK. Despite a decrease in bond strength after thermal cycling, no significant intergroup differences were observed, except for the line-shaped laser pattern. These findings indicate that the autofocus laser cutter effectively enhances the surface characteristics of PEEK by creating a uniform texture and grooves, showing promise in improving bonding properties, even considering the impact of thermal cycling effects.

18.
Polymers (Basel) ; 15(9)2023 Apr 28.
Artigo em Inglês | MEDLINE | ID: mdl-37177258

RESUMO

The effects of alumina particle size and jet pressure on the bond strength of polyetheretherketone (PEEK) were examined to determine the airborne particle abrasion parameters with minimal effects on PEEK and to achieve optimal bond strength, as a reference for future clinical use. An alumina particle with four particle sizes and three jet pressures was used to air-abrade PEEK. Surface roughness (Ra), morphology, chemical structure, and wettability were analyzed using a stylus profilometer, scanning electron microscope, X-ray diffractometer, and contact angle analyzer, respectively. The shear bond strength (SBS) of PEEK and dental resin cement was analyzed using a universal testing machine (n = 10). The failure modes and debonded fracture surfaces were observed using optical microscopy. Airborne particle abrasion increased the Ra and hydrophobicity of PEEK and deposited alumina residues. The SBS generally decreased after thermal cycling. A large particle size damaged the PEEK surface. The effects of different particle sizes and jet pressures on the SBS were only significant in certain groups. Adhesive failure was the main mode for all groups. Within the limitations of this study, 110 µm grain-sized alumina particles combined with a jet pressure of 2 bar prevented damage to PEEK, providing sufficient SBS and bonding durability between PEEK and dental resin cement.

19.
J Oral Sci ; 65(2): 127-130, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36990757

RESUMO

PURPOSE: The purpose of this study was to perform an in vitro evaluation of digital impressions using a mobile device and monoscopic photogrammetry in cases of orbital defects with undercuts. METHODS: Three 10-mm-square cubes were attached to a diagnostic cast of a patient with a right orbital defect. Still images acquired with a mobile device were used to generate facial three-dimensional (3D) data. Two types of still images were used: one was a whole face image, and the other was a defect site-focused image. For comparison, an extraoral scanner was used to obtain facial 3D data. Five dental technicians fabricated 3D printed models using additive manufacturing and measured the distances between the measurement points using a digital caliper. The discrepancy between the distances measured on the diagnostic cast of the patient and the 3D printed model was calculated. Friedman test was used to analyze the discrepancy, and the Bonferroni test was used to verify the differences between the pairs. RESULTS: Statistical significance was found with respect to the type of 3D model fabrication method. CONCLUSION: Within the limitations of this in vitro study, the results suggested that the workflow can be applied to digital impressions of the maxillofacial region.


Assuntos
Computadores de Mão , Imageamento Tridimensional , Humanos , Imageamento Tridimensional/métodos , Fotogrametria/métodos
20.
Int J Mol Sci ; 23(21)2022 Oct 24.
Artigo em Inglês | MEDLINE | ID: mdl-36361575

RESUMO

Glass-ceramic spray deposition (GCSD) is a novel technique for coating lithium disilicate (LD) glass-ceramics onto zirconia through simple tempering steps. GCSD has been proven to improve the bonding of zirconia to resin cement, but the effect of etching time on GCSD and the long-term durability of the bond achieved remain unknown. The effects of air abrasion with aluminum particles (ABB) and air abrasion (GAB) or etching with 5.0% hydrogen fluoride (HF) for 20, 60, 90, and 120 s (G20, G60, G90, and G120) on the resin cement−zirconia bond were studied. LD was included as a control (LDG). The microstructure, sub-micron roughness, wettability, and phase changes of samples were analyzed. After resin cement was bonded to zirconia, half of the samples were subjected to thermocycling (5000 cycles at 5−55 °C). The bond strengths of the samples were determined in shear bond strength (SBS) tests (n = 10 per group). An LD structure can be formed on zirconia after GCSD and proper etching processes, which result in high roughness and a hydrophilic nature. GCSD and HF etching significantly improved SBS, with G90 and G120 samples with pre- or post-thermocycling exhibiting SBS values comparable to those of LDG (p > 0.760). The surface characteristics of the LD layer are influenced by the etching time and affect the SBS of the bond of zirconia to resin cement. HF etching for 90−120 s after GCSD results in zirconia with SBS and bond durability comparable to LD.


Assuntos
Colagem Dentária , Zircônio , Zircônio/química , Cimentos de Resina/química , Adesivos , Teste de Materiais , Propriedades de Superfície , Cerâmica/química , Resistência ao Cisalhamento , Ácido Fluorídrico/química , Tecnologia