Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Tipo de estudo
Intervalo de ano de publicação
1.
Microorganisms ; 12(1)2024 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-38276198

RESUMO

Hospital-acquired pneumonia (HAP) and its subtype, ventilator-associated pneumonia (VAP), remain two significant causes of morbidity and mortality worldwide, despite the better understanding of pathophysiological mechanisms, etiology, risk factors, preventive methods (bundle of care principles) and supportive care. Prior detection of the risk factors combined with a clear clinical judgement based on clinical scores and dosage of different inflammatory biomarkers (procalcitonin, soluble triggering receptor expressed on myelloid cells type 1, C-reactive protein, mid-regional pro-adrenomedullin, mid-regional pro-atrial natriuretic peptide) represent the cornerstones of a well-established management plan by improving patient's outcome. This review article provides an overview of the newly approved terminology considering nosocomial pneumonia, as well as the risk factors, biomarkers, diagnostic methods and new treatment options that can guide the management of this spectrum of infections.

2.
J Pers Med ; 13(4)2023 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-37108973

RESUMO

The C-Nail® system is a novel intramedullary fixation method for displaced intra-articular calcaneal fractures. The aim of this study was to evaluate the biomechanical performance of the C-Nail® system and compare it with conventional plate fixation for the treatment of displaced intra-articular calcaneal fractures using finite element analysis. The geometry of a Sanders type-IIB fracture was constructed using the computer-aided design software Ansys SpaceClaim. The C-Nail® system (Medin, Nové Mesto n. Morave, Czech Republic) and the calcaneal locking plate (Auxein Inc., 35 Doral, Florida) and screws were designed according to the manufacturer specifications. Vertical loading of 350 N and 700 N were applied to the subtalar joint surfaces to simulate partial weight bearing and full weight bearing. Construct stiffness, total deformation, and von Mises stress were assessed. The maximum stress on the C-Nail® system was lower compared with the plate (110 MPa vs. 360 MPa). At the bone level the stress was found to have higher values in the case of the plate compared to the C-Nail® system. The study suggests that the C-Nail® system can provide sufficient stability, making it a viable option for the treatment of displaced intra-articular calcaneal fractures.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA