Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 46
Filtrar
1.
Am J Physiol Gastrointest Liver Physiol ; 326(2): G95-G106, 2024 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-38014449

RESUMO

Dried blood spot (DBS) analysis has existed for >50 years, but application of this technique to fecal analysis remains limited. To address whether dried fecal spots (DFS) could be used to measure fecal bile acids, we collected feces from five subjects for each of the following cohorts: 1) healthy individuals, 2) individuals with diarrhea, and 3) Clostridioides difficile-infected patients. Homogenized fecal extracts were loaded onto quantitative DBS (qDBS) devices, dried overnight, and shipped to the bioanalytical lab at ambient temperature. For comparison, source fecal extracts were shipped on dry ice and stored frozen. After 4 mo, frozen fecal extracts and ambient DFS samples were processed and subjected to targeted liquid chromatography-tandem mass spectrometry (LC-MS/MS)-based metabolomics with stable isotope-labeled standards. We observed no differences in the bile acid levels measured between the traditional extraction and the qDBS-based DFS methods. This pilot data demonstrates that DFS-based analysis is feasible and warrants further development for fecal compounds and microbiome applications.NEW & NOTEWORTHY Stool analysis in remote settings can be challenging, as the samples must be stored at -80°C and transported on dry ice for downstream processing. Our work indicates that dried fecal spots (DFS) on Capitainer quantitative DBS (qDBS) devices can be stored and shipped at ambient temperature and yields the same bile acid profiles as traditional samples. This approach has broad applications for patient home testing and sample collection in rural communities or resource-limited countries.


Assuntos
Gelo-Seco , Espectrometria de Massas em Tandem , Humanos , Cromatografia Líquida/métodos , Espectrometria de Massas em Tandem/métodos , Tecnologia , Ácidos e Sais Biliares
2.
PLoS One ; 18(2): e0281772, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36791076

RESUMO

Lipoprotein(a), also known as Lp(a), is an LDL-like particle composed of apolipoprotein(a) (apo(a)) bound covalently to apolipoprotein B100. Plasma concentrations of Lp(a) are highly heritable and vary widely between individuals. Elevated plasma concentration of Lp(a) is considered as an independent, causal risk factor of cardiovascular disease (CVD). Targeted mass spectrometry (LC-SRM/MS) combined with stable isotope-labeled recombinant proteins provides robust and precise quantification of proteins in the blood, making LC-SRM/MS assays appealing for monitoring plasma proteins for clinical implications. This study presents a novel quantitative approach, based on proteotypic peptides, to determine the absolute concentration of apo(a) from two microliters of plasma and qualified according to guideline requirements for targeted proteomics assays. After optimization, assay parameters such as linearity, lower limits of quantification (LLOQ), intra-assay variability (CV: 4.7%) and inter-assay repeatability (CV: 7.8%) were determined and the LC-SRM/MS results were benchmarked against a commercially available immunoassay. In summary, the measurements of an apo(a) single copy specific peptide and a kringle 4 specific peptide allow for the determination of molar concentration and relative size of apo(a) in individuals.


Assuntos
Apolipoproteínas A , Proteômica , Humanos , Apoproteína(a) , Peptídeos/química , Lipoproteína(a)
3.
Metabolomics ; 18(4): 24, 2022 04 09.
Artigo em Inglês | MEDLINE | ID: mdl-35397018

RESUMO

INTRODUCTION: The metabolomics quality assurance and quality control consortium (mQACC) is enabling the identification, development, prioritization, and promotion of suitable reference materials (RMs) to be used in quality assurance (QA) and quality control (QC) for untargeted metabolomics research. OBJECTIVES: This review aims to highlight current RMs, and methodologies used within untargeted metabolomics and lipidomics communities to ensure standardization of results obtained from data analysis, interpretation and cross-study, and cross-laboratory comparisons. The essence of the aims is also applicable to other 'omics areas that generate high dimensional data. RESULTS: The potential for game-changing biochemical discoveries through mass spectrometry-based (MS) untargeted metabolomics and lipidomics are predicated on the evolution of more confident qualitative (and eventually quantitative) results from research laboratories. RMs are thus critical QC tools to be able to assure standardization, comparability, repeatability and reproducibility for untargeted data analysis, interpretation, to compare data within and across studies and across multiple laboratories. Standard operating procedures (SOPs) that promote, describe and exemplify the use of RMs will also improve QC for the metabolomics and lipidomics communities. CONCLUSIONS: The application of RMs described in this review may significantly improve data quality to support metabolomics and lipidomics research. The continued development and deployment of new RMs, together with interlaboratory studies and educational outreach and training, will further promote sound QA practices in the community.


Assuntos
Lipidômica , Metabolômica , Espectrometria de Massas/métodos , Metabolômica/métodos , Controle de Qualidade , Reprodutibilidade dos Testes
4.
Methods Mol Biol ; 2228: 353-384, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33950503

RESUMO

The use of stable isotope-labeled standards (SIS) is an analytically valid means of quantifying proteins in biological samples. The nature of the labeled standards and their point of insertion in a bottom-up proteomic workflow can vary, with quantification methods utilizing curves in analytically sound practices. A promising quantification strategy for low sample amounts is external standard addition (ExSTA). In ExSTA, multipoint calibration curves are generated in buffer using serially diluted natural (NAT) peptides and a fixed concentration of SIS peptides. Equal concentrations of SIS peptides are spiked into experimental sample digests, with all digests (control and experimental) subjected to solid-phase extraction prior to liquid chromatography tandem mass spectrometry (LC-MS/MS) analysis. Endogenous peptide concentrations are then determined using the regression equation of the standard curves. Given the benefits of ExSTA in large-scale analysis, a detailed protocol is provided herein for quantifying a multiplexed panel of 125 high-to-moderate abundance proteins in undepleted and non-enriched human plasma samples. The procedural details and recommendations for successfully executing all phases of this quantification approach are described. As the proteins have been putatively correlated with various noncommunicable diseases, quantifying these by ExSTA in large-scale studies should help rapidly and precisely assess their true biomarker efficacy.


Assuntos
Proteínas Sanguíneas/análise , Marcação por Isótopo , Proteoma , Proteômica , Espectrometria de Massas por Ionização por Electrospray , Espectrometria de Massas em Tandem , Calibragem , Cromatografia de Fase Reversa , Humanos , Marcação por Isótopo/normas , Proteômica/normas , Padrões de Referência , Projetos de Pesquisa , Espectrometria de Massas em Tandem/normas
5.
Mol Cell Proteomics ; 18(12): 2433-2446, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31591263

RESUMO

Stable isotope-labeled standard (SIS) peptides are used as internal standards in targeted proteomics to provide robust protein quantification, which is required in clinical settings. However, SIS peptides are typically added post trypsin digestion and, as the digestion efficiency can vary significantly between peptides within a protein, the accuracy and precision of the assay may be compromised. These drawbacks can be remedied by a new class of internal standards introduced by the Human Protein Atlas project, which are based on SIS recombinant protein fragments called SIS PrESTs. SIS PrESTs are added initially to the sample and SIS peptides are released on trypsin digestion. The SIS PrEST technology is promising for absolute quantification of protein biomarkers but has not previously been evaluated in a clinical setting. An automated and scalable solid phase extraction workflow for desalting and enrichment of plasma digests was established enabling simultaneous preparation of up to 96 samples. Robust high-precision quantification of 13 apolipoproteins was achieved using a novel multiplex SIS PrEST-based LC-SRM/MS Tier 2 assay in non-depleted human plasma. The assay exhibited inter-day coefficients of variation between 1.5% and 14.5% (median = 3.5%) and was subsequently used to investigate the effects of omega-3 carboxylic acids (OM3-CA) and fenofibrate on these 13 apolipoproteins in human plasma samples from a randomized placebo-controlled trial, EFFECT I (NCT02354976). No significant changes were observed in the OM3-CA arm, whereas treatment with fenofibrate significantly increased apoAII and reduced apoB, apoCI, apoE and apoCIV levels. The reduction in apoCIV following fenofibrate treatment is a novel finding. The study demonstrates that SIS PrESTs can facilitate the generation of robust multiplexed biomarker Tier 2 assays for absolute quantification of proteins in clinical studies.


Assuntos
Apolipoproteínas/sangue , Ácidos Carboxílicos/farmacologia , Ácidos Graxos Ômega-3/farmacologia , Fenofibrato/farmacologia , Marcação por Isótopo , Espectrometria de Massas em Tandem/métodos , Adulto , Idoso , Biomarcadores/sangue , Estudos de Coortes , Método Duplo-Cego , Humanos , Marcação por Isótopo/normas , Pessoa de Meia-Idade , Fragmentos de Peptídeos , Proteínas Recombinantes , Reprodutibilidade dos Testes
6.
Sci Rep ; 9(1): 8570, 2019 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-31171809

RESUMO

A correction to this article has been published and is linked from the HTML and PDF versions of this paper. The error has been fixed in the paper.

7.
BMC Med Genomics ; 12(Suppl 2): 45, 2019 03 13.
Artigo em Inglês | MEDLINE | ID: mdl-30871558

RESUMO

BACKGROUND: The conditions of space flight have a significant effect on the physiological processes in the human body, yet the molecular mechanisms driving physiological changes remain unknown. METHODS: Blood samples of 18 Russian cosmonauts who had conducted long-duration missions to the International Space Station were collected 30 days before launch and on the first and seventh days after landing. RESULTS: A panel of 125 proteins in the blood plasma was quantitated by a well-established and highly regarded targeted mass spectrometry approach. This method involves the monitoring of multiple reactions in conjunction with stable isotope-labeled standards at the University of Victoria - Genome BC Proteomics Centre. CONCLUSIONS: Reduction of circulating plasma volume during space flight and activation of fluid retention at the final stage of the flight affect the changes in plasma protein concentrations present in the first days after landing. Using an ANOVA approach, it was revealed that only 1 protein (S100A9) reliably responded to space flight conditions. This protein plays an important role in the functioning of the endothelium and can serve as a marker for activation of inflammatory reactions. Concentrations of the proteins of complement, coagulation cascades, and acute phase reactants increase in the blood of cosmonauts as measured the first day after landing. Most of these proteins' concentrations continue to increase by the 7th day after space flight. Similar dynamics are observed for proteases and their inhibitors. Thus, there is a shift in proteolytic blood systems, which is necessary for the restoration of muscle tissue and maintenance of oncotic homeostasis.


Assuntos
Proteínas Sanguíneas/metabolismo , Proteômica/métodos , Voo Espacial , Adulto , Proteínas Sanguíneas/genética , Calgranulina B/metabolismo , Cromatografia Líquida de Alta Pressão , Humanos , Marcação por Isótopo , Masculino , Espectrometria de Massas , Pessoa de Meia-Idade
8.
J Proteomics ; 168: 28-36, 2017 09 25.
Artigo em Inglês | MEDLINE | ID: mdl-28757464

RESUMO

Offline high-pH reversed-phase fractionation is widely used to reduce sample complexity in proteomic workflows. This is due to the semi-orthogonality and high peak resolution of the two separations. Offline 2D fractionation, however, is low throughput and requires several manual manipulations and is prone to sample losses. To address these issues, we developed an online two dimensional high-pH - low-pH reversed-phase-reversed-phase (2D RPRP) LC-MRM method whereby hundreds of peptides can be quantified in a single LC-MS/MS injection. The method allowed the reproducible and sensitive quantitation of a test panel of 367 peptides (168 proteins) from undepleted and non-enriched human plasma. Of these, we were able to detect and quantify 95 peptides (29 proteins) by 2D-RPRP that were not detectable by 1D LC-MRM-MS. Online 2D RPRP resulted in an average increase of roughly 10-fold in sensitivity compared to traditional 1D low-pH separations, while improving reproducibility and sample throughput relative to offline 2D RPRP by factors of 1.7 and 5, respectively, compared to offline 2D RPRP. This paper serves as proof-of-concept of the feasibility and efficacy of online 2D RPRP at analytical flow rates for highly multiplexed targeted proteomic analyses.


Assuntos
Proteínas Sanguíneas/análise , Cromatografia de Fase Reversa/métodos , Sistemas On-Line/normas , Proteômica/normas , Humanos , Concentração de Íons de Hidrogênio , Proteômica/métodos
9.
Sci Rep ; 7(1): 8142, 2017 08 15.
Artigo em Inglês | MEDLINE | ID: mdl-28811532

RESUMO

The effects of spaceflight on human physiology is an increasingly studied field, yet the molecular mechanisms driving physiological changes remain unknown. With that in mind, this study was performed to obtain a deeper understanding of changes to the human proteome during space travel, by quantitating a panel of 125 proteins in the blood plasma of 18 Russian cosmonauts who had conducted long-duration missions to the International Space Station. The panel of labeled prototypic tryptic peptides from these proteins covered a concentration range of more than 5 orders of magnitude in human plasma. Quantitation was achieved by a well-established and highly-regarded targeted mass spectrometry approach involving multiple reaction monitoring in conjunction with stable isotope-labeled standards. Linear discriminant function analysis of the quantitative results revealed three distinct groups of proteins: 1) proteins with post-flight protein concentrations remaining stable, 2) proteins whose concentrations recovered slowly, or 3) proteins whose concentrations recovered rapidly to their pre-flight levels. Using a systems biology approach, nearly all of the reacting proteins could be linked to pathways that regulate the activities of proteases, natural immunity, lipid metabolism, coagulation cascades, or extracellular matrix metabolism.


Assuntos
Astronautas , Proteoma , Proteômica , Voo Espacial , Adulto , Cromatografia Líquida , Humanos , Masculino , Espectrometria de Massas , Pessoa de Meia-Idade , Proteômica/métodos
10.
J Proteome Res ; 16(7): 2527-2536, 2017 07 07.
Artigo em Inglês | MEDLINE | ID: mdl-28516774

RESUMO

When quantifying endogenous plasma proteins for fundamental and biomedical research - as well as for clinical applications - precise, reproducible, and robust assays are required. Targeted detection of peptides in a bottom-up strategy is the most common and precise mass spectrometry-based quantitation approach when combined with the use of stable isotope-labeled peptides. However, when measuring protein in plasma, the unknown endogenous levels prevent the implementation of the best calibration strategies, since no blank matrix is available. Consequently, several alternative calibration strategies are employed by different laboratories. In this study, these methods were compared to a new approach using two different stable isotope-labeled standard (SIS) peptide isotopologues for each endogenous peptide to be quantified, enabling an external calibration curve as well as the quality control samples to be prepared in pooled human plasma without interference from endogenous peptides. This strategy improves the analytical performance of the assay and enables the accuracy of the assay to be monitored, which can also facilitate method development and validation.


Assuntos
Bioensaio , Proteínas Sanguíneas/normas , Cromatografia Líquida/normas , Espectrometria de Massas/normas , Peptídeos/sangue , Proteômica/normas , Sequência de Aminoácidos , Aminoácidos/química , Proteínas Sanguíneas/química , Calibragem , Isótopos de Carbono , Humanos , Marcação por Isótopo/métodos , Isótopos de Nitrogênio , Peptídeos/normas , Proteômica/métodos , Padrões de Referência , Coloração e Rotulagem/métodos
11.
Proteomics ; 17(6)2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-27538354

RESUMO

An increasingly popular "absolute" quantitative technique involves the SRM or MRM approach with stable isotope-labeled standards (SIS). Using this approach, many proteins in human plasma/serum have been quantified for biomarker assessment and disease stratification. Due to the complexity of plasma and the invasive nature of its collection, alternative biosamples are currently being explored. Here, we present the broadest panel of multiplexed MRM assays with SIS peptides for saliva proteins developed to date. The validated panel consists of 158 candidate human saliva protein biomarkers, inferred from 244 interference-free peptides. The resulting concentrations were reproducibly quantified over a 6 order-of-magnitude concentration range (from 218 µg/mL to 88 pg/mL; average CVs of 12% over analytical triplicates). All concentrations were determined from reverse standard curves, which were generated using a constant concentration of endogenous material with varying concentrations of spiked-in SIS peptides. The large-scale screening of the soluble and membrane-associated proteins contained within the 158-plex assay could present new opportunities for biomarker assessment and clinical diagnostics.


Assuntos
Biomarcadores/metabolismo , Proteômica/métodos , Proteínas e Peptídeos Salivares/metabolismo , Adulto , Feminino , Humanos , Masculino , Peptídeos/metabolismo , Reprodutibilidade dos Testes , Saliva/metabolismo , Adulto Jovem
12.
Proteomics ; 17(7)2017 04.
Artigo em Inglês | MEDLINE | ID: mdl-27688154

RESUMO

The mouse is the most commonly used laboratory animal, with more than 14 million mice being used for research each year in North America alone. The number and diversity of mouse models is increasing rapidly through genetic engineering strategies, but detailed characterization of these models is still challenging because most phenotypic information is derived from time-consuming histological and biochemical analyses. To expand the biochemists' toolkit, we generated a set of targeted proteomic assays for mouse plasma and heart tissue, utilizing bottom-up LC/MRM-MS with isotope-labeled peptides as internal standards. Protein quantitation was performed using reverse standard curves, with LC-MS platform and curve performance evaluated by quality control standards. The assays comprising the final panel (101 peptides for 81 proteins in plasma; 227 peptides for 159 proteins in heart tissue) have been rigorously developed under a fit-for-purpose approach and utilize stable-isotope labeled peptides for every analyte to provide high-quality, precise relative quantitation. In addition, the peptides have been tested to be interference-free and the assay is highly multiplexed, with reproducibly determined protein concentrations spanning >4 orders of magnitude. The developed assays have been used in a small pilot study to demonstrate their application to molecular phenotyping or biomarker discovery/verification studies.


Assuntos
Proteínas Sanguíneas/análise , Miocárdio/metabolismo , Animais , Biomarcadores/sangue , Cromatografia Líquida/métodos , Marcação por Isótopo , Espectrometria de Massas/métodos , Camundongos , Camundongos Endogâmicos C57BL , Miocárdio/química
14.
Blood Adv ; 1(15): 1080-1087, 2017 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-29296750

RESUMO

The plasma levels of pro- and anticoagulant proteins are important markers for venous thrombosis (VT) risk and can be affected by both genetic and acquired factors, including cancer. Generally, these markers are measured using activity- or antibody-based assays. Targeted proteomics with stable-isotope-labeled internal standards has proven adept at the rapid, multiplex, and precise quantification of proteins in complex biological samples such as plasma. We used liquid chromatography coupled to multiple reaction monitoring (MRM) mass spectrometry to evaluate the concentrations of 31 coagulation- and fibrinolysis-related proteins in plasma from 25 healthy controls, 25 patients with VT, and 25 patients with VT who were also diagnosed with cancer. The concentration level of 1 to 3 proteotypic peptides per protein was determined, and all samples were previously characterized using traditional antibody- or activity-based methods. When comparing the conventional and the MRM strategies, the mean Pearson correlation for the 13 proteins (covered by 36 target peptides) shared between the 2 approaches was 0.77, indicating a good correlation. Additionally, MRM offers higher sensitivity (mean regression slope, 0.81), higher multiplicity in a single run, and good ability to leverage all measurements to discriminate groups using unsupervised clustering, which identified vitamin K antagonist users as well as patients with VT and cancer. The data collected using MRM show that the combination of coagulation factor levels yields signature information on VT and cancer, which was not obvious from a single measurement. These results encourage the further validation and investigation of MRM in profiling protein signature of disease.

15.
Adv Exp Med Biol ; 919: 515-530, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27975233

RESUMO

Quantitative mass spectrometry (MS)-based approaches are emerging as a core technology for addressing health-related queries in systems biology and in the biomedical and clinical fields. In several 'omics disciplines (proteomics included), an approach centered on selected or multiple reaction monitoring (SRM or MRM)-MS with stable isotope-labeled standards (SIS), at the protein or peptide level, has emerged as the most precise technique for quantifying and screening putative analytes in biological samples. To enable the widespread use of MRM-based protein quantitation for disease biomarker assessment studies and its ultimate acceptance for clinical analysis, the technique must be standardized to facilitate precise and accurate protein quantitation. To that end, we have developed a number of kits for assessing method/platform performance, as well as for screening proposed candidate protein biomarkers in various human biofluids. Collectively, these kits utilize a bottom-up LC-MS methodology with SIS peptides as internal standards and quantify proteins using regression analysis of standard curves. This chapter details the methodology used to quantify 192 plasma proteins of high-to-moderate abundance (covers a 6 order of magnitude range from 31 mg/mL for albumin to 18 ng/mL for peroxidredoxin-2), and a 21-protein subset thereof. We also describe the application of this method to patient samples for biomarker discovery and verification studies. Additionally, we introduce our recently developed Qualis-SIS software, which is used to expedite the analysis and assessment of protein quantitation data in control and patient samples.


Assuntos
Biologia Computacional/métodos , Mineração de Dados/métodos , Bases de Dados de Proteínas , Espectrometria de Massas/métodos , Proteínas/análise , Proteoma , Proteômica/métodos , Algoritmos , Biomarcadores/análise , Calibragem , Biologia Computacional/normas , Mineração de Dados/normas , Ensaios de Triagem em Larga Escala , Humanos , Espectrometria de Massas/normas , Valor Preditivo dos Testes , Proteômica/normas , Padrões de Referência , Reprodutibilidade dos Testes , Software
16.
Medicine (Baltimore) ; 95(39): e4808, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27684807

RESUMO

Although great success of microvascular free-flap transplantation surgery has been achieved in recent years, between 1.5% and 15% of flaps are still lost due to vascular occlusion. The clinical challenge remains to salvage a transplant in the case of vascular complications. Since flap loss is devastating for the patient, it is of utmost importance to detect signs of complications or of conspicuities as soon as possible. Rescue success rates highly depend on early revision. In this study, we collected blood samples during transplantation surgery from either the contributory artery or the effluent vein of the flap and applied a targeted mass spectrometry-based approach to quantify 24 acute phase proteins, cytokines, and growth factors in 63 plasma samples from 21 hospitalized patients, generating a dataset with 9450 protein concentration values. Biostatistical analyses of the targeted plasma protein concentrations in all 63 plasma samples showed that venous concentrations of macrophage colony-stimulating factor (M-CSF) provided the highest accuracy for discriminating patients with either clinical conspicuities or complications from control individuals. Using 21.33 ng/mL of M-CSF as the diagnostic threshold when analyzing venous blood plasma samples, the assay obtained a sensitivity of 0.93 and a specificity of 0.85 with an area under the curve value of 0.902 in the receiver operating characteristic analysis. Overall, our results indicate that M-CSF is a potential molecular marker for early risk prognosis of free-flap transplant failure.


Assuntos
Fator Estimulador de Colônias de Macrófagos/metabolismo , Disfunção Primária do Enxerto/sangue , Disfunção Primária do Enxerto/diagnóstico , Retalhos Cirúrgicos/efeitos adversos , Adulto , Idoso , Cromatografia Líquida , Citocinas/metabolismo , Feminino , Humanos , Peptídeos e Proteínas de Sinalização Intercelular/metabolismo , Masculino , Espectrometria de Massas , Pessoa de Meia-Idade , Imagem Multimodal , Prognóstico , Curva ROC , Risco , Sensibilidade e Especificidade
17.
Expert Rev Proteomics ; 13(7): 673-84, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-27341553

RESUMO

INTRODUCTION: Aided by the advent of advanced mass spectrometry (MS)-based technologies and methodologies, quantitative proteomics has emerged as a viable technique to capture meaningful data for candidate biomarker evaluation. To aid clinical translation, these methods generally utilize a bottom-up strategy with isotopically labeled standards and a targeted form of MS measurement. AREAS COVERED: This article reviews the status, challenges, requirements, and potential of translating current, MS-based methods to the clinical laboratory. The described methods are discussed and contrasted within a fit-for-purpose approach, while different resources for quality control, quantitative analysis, and data interpretation are additionally provided. Expert commentary: Although great strides have been made over the past five years in developing reliable quantitative assays for plasma protein biomarkers, it is crucial for investigators to have an understanding of the clinical validation process, a major roadblock in translational research. Continued progress in method design and validation of protein assays is necessary to ultimately achieve widespread adoption and regulatory approval.


Assuntos
Biomarcadores/sangue , Proteínas Sanguíneas/genética , Espectrometria de Massas , Proteômica , Proteínas Sanguíneas/biossíntese , Humanos
18.
Methods Mol Biol ; 1410: 1-21, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26867735

RESUMO

Absolute quantitative strategies are emerging as a powerful and preferable means of deriving concentrations in biological samples for systems biology applications. Method development is driven by the need to establish new-and validate current-protein biomarkers of high-to-low abundance for clinical utility. In this chapter, we describe a methodology involving two-dimensional (2D) reversed-phase liquid chromatography (RPLC), operated under alkaline and acidic pH conditions, combined with multiple reaction monitoring (MRM)-mass spectrometry (MS) (also called selected reaction monitoring (SRM)-MS) and a complex mixture of stable isotope-labeled standard (SIS) peptides, to quantify a broad and diverse panel of 253 proteins in human blood plasma. The quantitation range spans 8 orders of magnitude-from 15 mg/mL (for vitamin D-binding protein) to 450 pg/mL (for protein S100-B)-and includes 31 low-abundance proteins (defined as being <10 ng/mL) of potential disease relevance. The method is designed to assess candidates at the discovery and/or verification phases of the biomarker pipeline and can be adapted to examine smaller or alternate panels of proteins for higher sample throughput. Also detailed here is the application of our recently developed software tool-Qualis-SIS-for protein quantitation (via regression analysis of standard curves) and quality assessment of the resulting data. Overall, this chapter provides the blueprint for the replication of this quantitative proteomic method by proteomic scientists of all skill levels.


Assuntos
Proteínas Sanguíneas/análise , Cromatografia Líquida/métodos , Espectrometria de Massas/métodos , Peptídeos/análise , Proteômica/métodos , Humanos
19.
Bioanalysis ; 7(23): 2991-3004, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26626236

RESUMO

BACKGROUND: An increasingly popular mass spectrometry-based quantitative approach for health-related research in the biomedical field involves the use of stable isotope-labeled standards (SIS) and multiple/selected reaction monitoring (MRM/SRM). To improve inter-laboratory precision and enable more widespread use of this 'absolute' quantitative technique in disease-biomarker assessment studies, methods must be standardized. Results/methodology: Using this MRM-with-SIS-peptide approach, we developed an automated method (encompassing sample preparation, processing and analysis) for quantifying 76 candidate protein markers (spanning >4 orders of magnitude in concentration) in neat human plasma. DISCUSSION/CONCLUSION: The assembled biomarker assessment kit - the 'BAK-76' - contains the essential materials (SIS mixes), methods (for acquisition and analysis), and tools (Qualis-SIS software) for performing biomarker discovery or verification studies in a rapid and standardized manner.


Assuntos
Biomarcadores/sangue , Proteínas Sanguíneas/análise , Padrões de Referência , Humanos , Controle de Qualidade
20.
Mol Cell Proteomics ; 14(11): 3094-104, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26342038

RESUMO

The dried blood spot (DBS) methodology provides a minimally invasive approach to sample collection and enables room-temperature storage for most analytes. DBS samples have successfully been analyzed by liquid chromatography multiple reaction monitoring mass spectrometry (LC/MRM-MS) to quantify a large range of small molecule biomarkers and drugs; however, this strategy has only recently been explored for MS-based proteomics applications. Here we report the development of a highly multiplexed MRM assay to quantify endogenous proteins in human DBS samples. This assay uses matching stable isotope-labeled standard peptides for precise, relative quantification, and standard curves to characterize the analytical performance. A total of 169 peptides, corresponding to 97 proteins, were quantified in the final assay with an average linear dynamic range of 207-fold and an average R(2) value of 0.987. The total range of this assay spanned almost 5 orders of magnitude from serum albumin (P02768) at 18.0 mg/ml down to cholinesterase (P06276) at 190 ng/ml. The average intra-assay and inter-assay precision for 6 biological samples ranged from 6.1-7.5% CV and 9.5-11.0% CV, respectively. The majority of peptide targets were stable after 154 days at storage temperatures from -20 °C to 37 °C. Furthermore, protein concentration ratios between matching DBS and whole blood samples were largely constant (<20% CV) across six biological samples. This assay represents the highest multiplexing yet achieved for targeted protein quantification in DBS samples and is suitable for biomedical research applications.


Assuntos
Bioensaio , Proteínas Sanguíneas/isolamento & purificação , Teste em Amostras de Sangue Seco/normas , Peptídeos/isolamento & purificação , Cromatografia Líquida , Teste em Amostras de Sangue Seco/instrumentação , Teste em Amostras de Sangue Seco/métodos , Humanos , Marcação por Isótopo , Estabilidade Proteica , Proteômica , Reprodutibilidade dos Testes , Espectrometria de Massas em Tandem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA