Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Anal Chem ; 96(4): 1397-1401, 2024 01 30.
Artigo em Inglês | MEDLINE | ID: mdl-38243802

RESUMO

An instrument integrating thermal desorption (TD) to selected ion flow tube mass spectrometry (SIFT-MS) is presented, and its application to analyze volatile organic compounds (VOCs) in human breath is demonstrated for the first time. The rationale behind this development is the need to analyze breath samples in large-scale multicenter clinical projects involving thousands of patients recruited in different hospitals. Following adapted guidelines for validating analytical techniques, we developed and validated a targeted analytical method for 21 compounds of diverse chemical class, chosen for their clinical and biological relevance. Validation has been carried out by two independent laboratories, using calibration standards and real breath samples from healthy volunteers. The merging of SIFT-MS and TD integrates the rapid analytical capabilities of SIFT-MS with the capacity to collect breath samples across multiple hospitals. Thanks to these features, the novel instrument has the potential to be easily employed in clinical practice.


Assuntos
Líquidos Corporais , Compostos Orgânicos Voláteis , Humanos , Compostos Orgânicos Voláteis/análise , Testes Respiratórios/métodos , Espectrometria de Massas/métodos , Líquidos Corporais/química
2.
Anal Methods ; 15(46): 6435-6443, 2023 11 30.
Artigo em Inglês | MEDLINE | ID: mdl-37971404

RESUMO

In September 2020, traces of ethylene oxide (a toxic substance used as a pesticide in developing countries but banned for use on food items within the European Union) were found in foodstuffs containing ingredients derived from imported sesame seed products. Vast numbers of foodstuffs were recalled across Europe due to this contamination, leading to expensive market losses and extensive trace exposure of ethylene oxide to consumers. Therefore, a rapid analysis method is needed to ensure food safety by high-throughput screening for ethylene oxide contamination. Selected ion flow tube mass spectrometry (SIFT-MS) is a suitable method for rapid quantification of trace amounts of vapours in the headspace of food samples. It turns out, however, that the presence of acetaldehyde complicates SIFT-MS analyses of its isomer ethylene oxide. It was proposed that a combination of the H3O+ and NO+ reagent ions can be used to analyse ethylene oxide in the presence of acetaldehyde. This method is, however, not robust because of the product ion overlaps and potential interferences from other matrix species. Thus, we studied the kinetics of the reactions of the H3O+, NO+, OH- and O-˙ ions with these two compounds and obtained their rate coefficients and product ion branching ratios. Interpretation of these experimental data revealed that the OH- anions are the most suitable SIFT-MS reagents because the product ions of their reactions with acetaldehyde (CH2CHO- at m/z 43) and ethylene oxide (C2H3O2- at m/z 59) do not overlap.


Assuntos
Acetaldeído , Óxido de Etileno , Espectrometria de Massas/métodos , Gases/química , Íons
3.
Rapid Commun Mass Spectrom ; 36(4): e9230, 2022 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-34862682

RESUMO

RATIONALE: Recycled plastics are increasingly used for packaging of fast-moving consumer goods (FMCG). Compared with packaging made from virgin polymers, there is greater risk of taints entering products due to prior use of the polymers and incomplete cleaning. Increased quality assurance testing of polymer feedstock is required for recycled packaging. Selected ion flow tube mass spectrometry (SIFT-MS) analysis coupled with multivariate statistical data processing can provide high-throughput untargeted screening of recycled polymers at low cost per sample. METHODS: SIFT-MS is a direct-injection MS technique that provides high-throughput automated headspace analysis of polymer samples when coupled with a syringe-injection autosampler (12 incubated samples per hour). Full-scan SIFT-MS data were processed using multivariate statistical analysis (specifically, the soft independent modeling by class analogy (SIMCA) algorithm). RESULTS: SIFT-MS full-scan data were acquired for ten replicates each of ten recycled and four virgin high-density polyethylene (HDPE) pellet products from multiple manufacturers. The samples varied approximately 20-fold in terms of total volatile residue, while showing very high repeatability across replicates. SIFT-MS scan data were dominated by aliphatic and monoterpene hydrocarbon residues, and - to a lesser extent - alcohols. Application of the SIMCA algorithm to the data resulted in successful classification by both individual samples and manufacturers. CONCLUSIONS: Automated, untargeted SIFT-MS analysis coupled with multivariate statistical data analysis has the potential to provide rapid, effective screening of recycled polymer products, which would provide increased quality assurance of recycled polymers used for FMCG.

4.
Anal Chem ; 93(24): 8386-8392, 2021 06 22.
Artigo em Inglês | MEDLINE | ID: mdl-34101412

RESUMO

Analysis of volatile organic compounds (VOCs) in water is conventionally conducted using gas chromatography (GC)-based methods, for which sample preparation demands are relatively high and throughput is relatively low due to the time taken to achieve chromatographic separation. Direct mass spectrometry (DMS) techniques such as selected ion flow tube mass spectrometry (SIFT-MS) have potential to analyze water headspace (HS) at high sensitivity with minimal sample preparation, eliminating preconcentration/purging and/or water management steps. However, the dearth of guidance for validation of DMS methods is an impediment to their adoption in routine analysis. This study applies and adapts an internationally recognized pharmaceutical industry guidance document for method validation to a prototypical SIFT-MS headspace analysis method for 17 toxic VOCs in water. The approach to validation is, however, applicable to any routine analysis conducted using SIFT-MS, and very likely to any methods developed using other DMS techniques. For the method developed and validated here, linearities (as measured by the linear regression coefficient, R2) were better than 0.990 for all compounds. Repeatability (measured using relative standard deviation, RSD) was less than 10% for all compounds. Similar method performance was observed for accuracy and recovery. The performance criteria achieved by this HS-SIFT-MS method suggest it has potential application in environmental and pharmaceutical routine analyses, perhaps as a rapid screening tool.


Assuntos
Compostos Orgânicos Voláteis , Cromatografia Gasosa-Espectrometria de Massas , Espectrometria de Massas , Compostos Orgânicos Voláteis/análise , Água
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA