Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 74
Filtrar
1.
Physiol Rep ; 12(11): e16096, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38837627

RESUMO

Superficial, systemic microcirculations, distinct from the pulmonary circulation, supply the mucosae of human nasal and conducting airways. Non-injurious, inflammatory challenges of the airway mucosa cause extravasation without overt mucosal oedema. Instead, likely reflecting minimal increases in basolateral hydrostatic pressure, circulating proteins/peptides of all sizes are transmitted paracellularly across the juxtaposed epithelial barrier. Thus, small volumes of extravasated, unfiltered bulk plasma appear on the mucosal surface at nasal and bronchial sites of challenge. Importantly, the plasma-exuding mucosa maintains barrier integrity against penetrability of inhaled molecules. Thus, one-way epithelial penetrability, strict localization, and well-controlled magnitude and duration are basic characteristics of the plasma exudation response in human intact airways. In vivo experiments in human-like airways demonstrate that local plasma exudation is also induced by non-sanguineous removal of epithelium over an intact basement membrane. This humoral response results in a protective, repair-promoting barrier kept together by a fibrin-fibronectin net. Plasma exudation stops once the provisional barrier is substituted by a new cellular cover consisting of speedily migrating repair cells, which may emanate from all types of epithelial cells bordering the denuded patch. Exuded plasma on the surface of human airways reflects physiological microvascular-epithelial cooperation in first line mucosal defense at sites of intact and regenerating epithelium.


Assuntos
Proteínas Sanguíneas , Mucosa Respiratória , Humanos , Proteínas Sanguíneas/metabolismo , Regeneração/fisiologia , Mucosa Respiratória/metabolismo
5.
Am J Respir Crit Care Med ; 206(7): 922-923, 2022 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-35737585

Assuntos
Asma , COVID-19 , Humanos , SARS-CoV-2
8.
J Allergy Clin Immunol ; 149(3): 1131-1132, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-35000774
9.
10.
Scand J Immunol ; 93(6): e13024, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33523532

RESUMO

Early airway responses to severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) infection are of interest since they could decide whether coronavirus disease-19 (COVID-19) will proceed to life-threatening pulmonary disease stages. Here I discuss endothelial-epithelial co-operative in vivo responses producing first-line, humoral innate defence opportunities in human airways. The pseudostratified epithelium of human nasal and tracheobronchial airways are prime sites of exposure and infection by SARS-CoV-2. Just beneath the epithelium runs a profuse systemic microcirculation. Its post-capillary venules respond conspicuously to mucosal challenges with autacoids, allergens and microbes, and to mere loss of epithelium. By active venular endothelial gap formation, followed by transient yielding of epithelial junctions, non-sieved plasma macromolecules move from the microcirculation to the mucosal surface. Hence, plasma-derived protein cascade systems and antimicrobial peptides would have opportunity to operate jointly on an unperturbed mucosal lining. Similarly, a plasma-derived, dynamic gel protects sites of epithelial sloughing-regeneration. Precision for this indiscriminate humoral molecular response lies in restricted location and well-regulated duration of plasma exudation. Importantly, the endothelial responsiveness of the airway microcirculation differs distinctly from the relatively non-responsive, low-pressure pulmonary microcirculation that non-specifically, almost irreversibly, leaks plasma in life-threatening COVID-19. Observations in humans of infections with rhinovirus, coronavirus 229E, and influenza A and B support a general but individually variable early occurrence of plasma exudation in human infected nasal and tracheobronchial airways. Investigations are warranted to elucidate roles of host- and drug-induced airway plasma exudation in restriction of viral infection and, specifically, whether it contributes to variable disease responses following exposure to SARS-CoV-2.


Assuntos
COVID-19/imunologia , COVID-19/virologia , Interações Hospedeiro-Patógeno/imunologia , Imunidade Humoral , Mucosa Respiratória/imunologia , Mucosa Respiratória/virologia , SARS-CoV-2/imunologia , Anticorpos Antivirais/sangue , Anticorpos Antivirais/imunologia , Biomarcadores/sangue , Proteínas Sanguíneas , COVID-19/diagnóstico , COVID-19/metabolismo , Permeabilidade Capilar/imunologia , Ativação do Complemento/imunologia , Proteínas do Sistema Complemento/imunologia , Proteínas do Sistema Complemento/metabolismo , Exsudatos e Transudatos , Humanos , Imunidade Inata , Imunoglobulina M/sangue , Imunoglobulina M/imunologia , Microvasos/imunologia , Microvasos/metabolismo , Mucosa Respiratória/metabolismo
11.
J Innate Immun ; 12(5): 373-386, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32203966

RESUMO

Based on observations in vivo in guinea-pig and human airways, this review presents plasma exudation as non-sieved transmission of bulk plasma across an unperturbed mucosa that maintains its normal barrier functions. Several steps have led to the present understanding of plasma exudation as a non-injurious response to mucosal challenges. The implication of a swift appearance of all circulating multipotent protein systems (also including antimicrobial peptides that now are viewed as being exclusively produced by local cells) on challenged, but intact, mucosal surfaces cannot be trivial. Yet, involvement of early plasma exudation responses in innate mucosal immunology has dwelled below the radar. Admittedly, exploration of physiological plasma exudation mechanisms requires in vivo approaches beyond mouse studies. Plasma exudation also lacks the specificity that is a hallmark of biological revelations. These aspects separate plasma exudation from mainstream progress in immunology. The whole idea, presented here, thus competes with strong paradigms currently entertained in the accepted research front. The present focus on humoral innate immunity in vivo further deviates from most discussions, which concern cell-mediated innate defence. Indeed, plasma exudation has emerged as sole in vivo source of major mucosal defence proteins that now are viewed as local cell produce. In conclusion, this review highlights opportunities for complex actions and interactions provided by non-sieved plasma proteins/peptides on the surface of intact mucosal barriers in vivo.


Assuntos
Imunidade Inata , Mucosa/imunologia , Animais , Proteínas Sanguíneas/imunologia , Proteínas Sanguíneas/metabolismo , Exsudatos e Transudatos/imunologia , Exsudatos e Transudatos/metabolismo , Humanos , Mucosa/metabolismo , Plasma/imunologia , Plasma/metabolismo , Doenças Respiratórias/imunologia , Doenças Respiratórias/patologia
13.
Eur Respir J ; 54(4)2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31248957

RESUMO

Observations in vivo in patients, supported by guinea-pig in vivo data, take centre stage in this perspective. Its objective is to highlight dichotomies between asthma features observed in vivo and accepted views involving cell/molecular biology research paradigms. For example, increased bronchial epithelial permeability is now considered a major paradigm and trait of asthma, yet, absorption of inhaled tracers has not been increased in vivo in asthma. Such maintained barrier function in exudative asthma reflects in vivo asymmetry of the epithelial lining as barrier between outside and inside world of molecules and cells. In desquamatory asthma, maintained epithelial tightness may be explained by in vivo demonstrations of exceedingly patchy epithelial loss, prompt creation of plasma-derived provisional barriers, and high-speed epithelial regeneration. Acknowledged protein/peptide secretion by epithelial cells in vitro is contrasted here with a dominant, unidirectional movement in vivo of plasma-derived proteins/peptides (including antimicrobial peptides) to the surface of an intact epithelial lining. Furthermore, longstanding claims that epithelium-produced adenosine is a mediator of asthma are eroded by observations in vivo in asthmatics. Notions concerning activation/fate of mucosal tissue eosinophils illustrate additional distinctions between accepted views and in vivo patient observations. Finally, in vitro-based paradigms preaching defect epithelial regeneration and increased permeability in pathogenesis of asthma are contrasted with experimental in vivo observations of exaggerated epithelial regeneration, which is multipathogenic in its own right. In conclusion, unexpected and challenging in vivo observations in recent decades underpin novel insights into mucosal mechanisms in asthma.


Assuntos
Asma/metabolismo , Eosinófilos/metabolismo , Células Epiteliais/metabolismo , Mucosa Respiratória/metabolismo , Animais , Peptídeos Catiônicos Antimicrobianos/metabolismo , Apoptose , Asma/patologia , Asma/fisiopatologia , Morte Celular , Eosinófilos/patologia , Eosinófilos/fisiologia , Células Epiteliais/patologia , Células Epiteliais/fisiologia , Exsudatos e Transudatos , Cobaias , Humanos , Permeabilidade , Fagocitose , Regeneração , Mucosa Respiratória/patologia , Mucosa Respiratória/fisiopatologia
14.
Int J Sport Nutr Exerc Metab ; 29(4): 435­440, 2019 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-30632440

RESUMO

Dual-energy X-ray absorptiometry is a commonly used clinical assessment tool for body composition and bone mineral density, which is gaining popularity in athletic cohorts. Results from body composition scans are useful for athletic populations to track training and nutritional interventions, while bone mineral density scans are valuable for athletes at risk of developing stress fractures due to low bone mineral density. However, no research has ascertained if a novice technician (accredited but not experienced) could produce similar results to an experienced technician. Two groups of recreational athletes were scanned, one by an experienced technician, one by a novice technician. All participants were scanned twice with repositioning between scans. The experienced technician's reliability (intraclass correlation coefficient = .989-.998; percentage change in mean = -0.01 to 0.10), precision (typical error as coefficient of variation percentage = 0.01-0.47; SEM% = 0.61-1.39), and sensitivity to change (smallest real difference percentage = 1.70-3.85) were similar; however, superior to those of the novice technician. The novice technician results were reliability (intraclass correlation coefficient = .985-.997; percentage change in mean = -0.03 to 0.23), precision (typical error as coefficient of variation percentage = 0.03-0.75; SEM% = 1.06-2.12), and sensitivity to change (smallest real difference percentage = 2.73-5.86). Extensive experience, while valuable, is not a necessary requirement to produce quality results when undertaking whole-body dual-energy X-ray absorptiometry scanning.


Assuntos
Absorciometria de Fóton , Composição Corporal , Densidade Óssea , Variações Dependentes do Observador , Competência Profissional , Adolescente , Adulto , Feminino , Humanos , Masculino , Projetos Piloto , Reprodutibilidade dos Testes , Adulto Jovem
15.
J Allergy Clin Immunol ; 143(4): 1271-1286, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30170125

RESUMO

This review discusses in vivo airway aspects of plasma exudation in relation to current views on epithelial permeability and epithelial regeneration in health and disease. Microvascular-epithelial exudation of bulk plasma proteins characteristically occurs in asthmatic patients, being especially pronounced in those with severe and exacerbating asthma. Healthy human and guinea pig airways challenged by noninjurious histamine-leukotriene-type autacoids also respond through prompt mucosal exudation of nonsieved plasma macromolecules. Contrary to current beliefs, epithelial permeability in the opposite direction (ie, absorption of inhaled molecules) has not been increased in patients with asthma and allergic rhinitis or in acutely exuding healthy airways. A slightly increased subepithelial hydrostatic pressure produces such unidirectional outward perviousness to macromolecules. Lack of increased absorption permeability in asthmatic patients can further be reconciled with occurrence of epithelial shedding, leaving small patches of denuded basement membrane. Counteracting escalating barrier breaks, plasma exudation promptly covers the denuded patches. Here it creates and sustains a biologically active barrier involving a neutrophil-rich, fibrin-fibronectin net. Furthermore, in the plasma-derived milieu, all epithelial cell types bordering the denuded patch dedifferentiate and migrate from all sides to cover the denuded basement membrane. However, this speedy epithelial regeneration can come at a cost. Guinea pig in vivo studies demonstrate that patches of epithelial denudation regeneration are exudation hot spots evoking asthma-like features, including recruitment/activation of granulocytes, proliferation of fibrocytes/smooth muscle cells, and basement membrane thickening. In conclusion, nonsieved plasma macromolecules can operate on the intact airway mucosa as potent components of first-line innate immunity responses. Exuded plasma also takes center stage in epithelial regeneration. When exaggerated, epithelial regeneration can contribute to the inception and development of asthma.


Assuntos
Asma/metabolismo , Permeabilidade da Membrana Celular/fisiologia , Imunidade Inata/imunologia , Plasma/metabolismo , Mucosa Respiratória/metabolismo , Animais , Asma/imunologia , Exsudatos e Transudatos/imunologia , Exsudatos e Transudatos/metabolismo , Humanos , Plasma/imunologia , Regeneração/fisiologia , Mucosa Respiratória/imunologia
17.
J Sci Med Sport ; 21(10): 1038-1044, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29588115

RESUMO

OBJECTIVES: To systematically identify and assess methods and protocols used to reduce technical and biological errors in published studies that have investigated reliability of dual energy X-ray absorptiometry (DXA) for assessing body composition. DESIGN: Systematic review. METHODS: Systematic searches of five databases were used to identify studies of DXA reliability. Two independent reviewers used a modified critical appraisal tool to assess their methodological quality. Data was extracted and synthesised using a level of evidence approach. Further analysis was then undertaken of methods used to decrease DXA errors (technical and biological) and so enhance DXA reliability. RESULTS: Twelve studies met eligibility criteria. Four of the articles were deemed high quality. Quality articles considered biological and technical errors when preparing participants for DXA scanning. The Nana positioning protocol was assessed to have a strong level of evidence. The studies providing this evidence indicated very high test-retest reliability (ICC 0.90-1.00 or less than 1% change in mean) of the Nana positioning protocol. The National Health and Nutrition Examination Survey (NHANES) positioning protocol was deemed to have a moderate level of evidence due to lack of high quality studies. However, the available studies found the NHANES positioning protocol had very high test-retest reliability. Evidence is limited and reported reliability has varied in papers where no specific positioning protocol was used or reported. CONCLUSIONS: Due to the strong level of evidence of excellent test-retest reliability that supports use of the Nana positioning protocol, it is recommended as the first choice for clinicians when using DXA to assess body composition.


Assuntos
Absorciometria de Fóton , Composição Corporal , Posicionamento do Paciente/métodos , Humanos , Reprodutibilidade dos Testes
19.
Int J Sport Nutr Exerc Metab ; 28(1): 19-25, 2018 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-28871851

RESUMO

The Nana positioning protocol is widely used to position participants to minimize technical error when undertaking body composition scanning and analysis with a Dual energy X-Ray absorptiometry (DXA) machine. Once biological and technical errors are accounted for, the only variation in test-retest results is from statistical fluctuation or machine error. Therefore, the aim of this study is to assess the test-retest reliability of the Nana positioning protocol and establish the smallest real difference percentage (SRD%). A gender-balanced group of 30 participants (15 males, 15 females) underwent two scans in succession using the Nana positioning protocol, with repositioning between scans. Percentage change in mean with typical error, Intraclass Correlation Coefficients (ICC), and standard error measurement percentage (SEM%) were used to identify the test-retest reliability and error rate of these protocols. Additionally, SRD% was calculated to assess the point at which clinically important changes occurred in a participant. The reliabilities of the whole body and regional scans were excellent. Percentage change in mean ranged between 0.00% and 0.23%. High reproducibility of the Nana positioning protocol was evident through an ICC ranging between 0.966-1.000. Additionally, typical error, SEM%, and SRD% were all low. Interestingly, fat mass was associated with the largest fluctuations observed to be associated with any of the parameters assessed. When all sources of biological and technical errors have been accounted for, the Nana positioning protocol has excellent test-retest reliability and produces low SEM% and SRD%.


Assuntos
Absorciometria de Fóton , Composição Corporal , Posicionamento do Paciente/métodos , Adulto , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Adulto Jovem
20.
PeerJ ; 5: e3880, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29062599

RESUMO

BACKGROUND: Dual energy X-ray absorptiometry (DXA) is a commonly used instrument for analysing segmental body composition (BC). The information from the scan guides the clinician in the treatment of conditions such as obesity and can be used to monitor recovery of lean mass following injury. Two commonly used DXA positioning protocols have been identified-the Nana positioning protocol and the National Health and Nutrition Examination Survey (NHANES). Both protocols have been shown to be reliable. However, only one study has assessed the level of agreement between the protocols and ascertained the participants' preference of protocol based upon comfort. Given the paucity of research in the field and the growing use of DXA in both healthy and pathological populations further research determining the most appropriate positioning protocol is warranted. Therefore, the aims of this study were to assess the level of agreement between results from the NHANES protocol and Nana protocol, and the participants' preference of protocol based on comfort. METHODS: Thirty healthy participants (15 males, 15 females, aged 23-59 years) volunteered to participate in this study. These participants underwent two whole body DXA scans in a single morning (Nana positioning protocol and NHANES positioning protocol), in a randomised order. Each participant attended for scanning wearing minimal clothing and having fasted overnight, refrained from exercise in the past 24 h and voided their bladders. Level of agreement, comparing NAHNES to Nana protocol was assessed using an intra-class correlation coefficient (ICC), concordance correlation coefficient (CCC) and percentage change in mean. Limit of agreement comparing the two protocols were assessed using plots, mean difference and confidence limits. Participants were asked to indicate the protocol they found most comfortable. RESULTS: When assessing level of agreement between protocols both the ICC and CCC scores were very high and ranged from 0.987 to 0.997 for whole body composition, indicating excellent agreement between the Nana and NHANES protocols. Regional analysis (arms, legs, trunk) ICC scores, ranged between 0.966 and 0.996, CCC ranged between 0.964 and 0.997, change in mean percentage ranged between -0.58% and 0.37% which indicated a very high level of agreement. Limit of agreement analysis using mean difference ranged between -0.223 and 0.686 kg and 95% CL produced results ranging between -1.262 kg and 1.630 kg. The majority (80%) of participants found the NHANES positioning protocol more comfortable. DISCUSSION: This study reveals a strong level of agreement as illustrated by high ICC's and CCC's between the positioning protocols, however systematic bias within limit of agreement plot and a large difference in 95% confidence limits indicates that the protocols should not be interchanged when assessing an individual. The NHANES protocol affords greater participant comfort.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA