Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Proc Natl Acad Sci U S A ; 115(5): E925-E933, 2018 01 30.
Artigo em Inglês | MEDLINE | ID: mdl-29339495

RESUMO

Proximity ligation assay (PLA) is a powerful tool for quantitative detection of protein biomarkers in biological fluids and tissues. Here, we present the circular proximity ligation assay (c-PLA), a highly specific protein detection method that outperforms traditional PLA in stringency, ease of use, and compatibility with low-affinity reagents. In c-PLA, two proximity probes bind to an analyte, providing a scaffolding that positions two free oligonucleotides such that they can be ligated into a circular DNA molecule. This assay format stabilizes antigen proximity probe complexes and enhances stringency by reducing the probability of random background ligation events. Circle formation also increases selectivity, since the uncircularized DNA can be removed enzymatically. We compare this method with traditional PLA on several biomarkers and show that the higher stringency for c-PLA improves reproducibility and enhances sensitivity in both buffer and human plasma. The limit of detection ranges from femtomolar to nanomolar concentrations for both methods. Kinetic analyses using surface plasmon resonance (SPR) and biolayer interferometry (BLI) reveal that the variation in limit of detection is due to the variation in antibody affinity and that c-PLA outperforms traditional PLA for low-affinity antibodies. The lower background signal can be used to increase proximity probe concentration while maintaining a high signal-to-noise ratio, thereby enabling the use of low-affinity reagents in a homogeneous assay format. We anticipate that the advantages of c-PLA will be useful in a variety of clinical protein detection applications where high-affinity reagents are lacking.


Assuntos
Anticorpos/química , Biomarcadores/química , Proteínas Sanguíneas/química , Mapeamento de Interação de Proteínas/métodos , Afinidade de Anticorpos , DNA de Cadeia Simples/química , Relação Dose-Resposta a Droga , Humanos , Imunoensaio , Oligonucleotídeos , Fosforilação , Reação em Cadeia da Polimerase , Ligação Proteica , Proteômica , Reprodutibilidade dos Testes
2.
PLoS One ; 11(5): e0154707, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27149617

RESUMO

DNA sequencing by imaging in an electron microscope is an approach that holds promise to deliver long reads with low error rates and without the need for amplification. Earlier work using transmission electron microscopes, which use high electron energies on the order of 100 keV, has shown that low contrast and radiation damage necessitates the use of heavy atom labeling of individual nucleotides, which increases the read error rates. Other prior work using scattering electrons with much lower energy has shown to suppress beam damage on DNA. Here we explore possibilities to increase contrast by employing two methods, X-ray photoelectron and Auger electron spectroscopy. Using bulk DNA samples with monomers of each base, both methods are shown to provide contrast mechanisms that can distinguish individual nucleotides without labels. Both spectroscopic techniques can be readily implemented in a low energy electron microscope, which may enable label-free DNA sequencing by direct imaging.


Assuntos
Análise de Sequência de DNA/métodos , Análise Espectral/métodos , Elétrons
3.
Artigo em Inglês | MEDLINE | ID: mdl-23847748

RESUMO

Monochromatic, aberration-corrected, dual-beam low energy electron microscopy (MAD-LEEM) is a novel imaging technique aimed at high resolution imaging of macromolecules, nanoparticles, and surfaces. MAD-LEEM combines three innovative electron-optical concepts in a single tool: a monochromator, a mirror aberration corrector, and dual electron beam illumination. The monochromator reduces the energy spread of the illuminating electron beam, which significantly improves spectroscopic and spatial resolution. The aberration corrector is needed to achieve subnanometer resolution at landing energies of a few hundred electronvolts. The dual flood illumination approach eliminates charging effects generated when a conventional, single-beam LEEM is used to image insulating specimens. The low landing energy of electrons in the range of 0 to a few hundred electronvolts is also critical for avoiding radiation damage, as high energy electrons with kilo-electron-volt kinetic energies cause irreversible damage to many specimens, in particular biological molecules. The performance of the key electron-optical components of MAD-LEEM, the aberration corrector combined with the objective lens and a magnetic beam separator, was simulated. Initial results indicate that an electrostatic electron mirror has negative spherical and chromatic aberration coefficients that can be tuned over a large parameter range. The negative aberrations generated by the electron mirror can be used to compensate the aberrations of the LEEM objective lens for a range of electron energies and provide a path to achieving subnanometer spatial resolution. First experimental results on characterizing DNA molecules immobilized on Au substrates in a LEEM are presented. Images obtained in a spin-polarized LEEM demonstrate that high contrast is achievable at low electron energies in the range of 1-10 eV and show that small changes in landing energy have a strong impact on the achievable contrast. The MAD-LEEM approach promises to significantly improve the performance of a LEEM for a wide range of applications in the biosciences, material sciences, and nanotechnology where nanometer scale resolution and analytical capabilities are required. In particular, the microscope has the potential of delivering images of unlabeled DNA strands with nucleotide-specific contrast. This simplifies specimen preparation and significantly eases the computational complexity needed to assemble the DNA sequence from individual reads.

4.
Nature ; 462(7276): 1075-8, 2009 Dec 24.
Artigo em Inglês | MEDLINE | ID: mdl-20010806

RESUMO

Techniques to detect and quantify DNA and RNA molecules in biological samples have had a central role in genomics research. Over the past decade, several techniques have been developed to improve detection performance and reduce the cost of genetic analysis. In particular, significant advances in label-free methods have been reported. Yet detection of DNA molecules at concentrations below the femtomolar level requires amplified detection schemes. Here we report a unique nanomechanical response of hybridized DNA and RNA molecules that serves as an intrinsic molecular label. Nanomechanical measurements on a microarray surface have sufficient background signal rejection to allow direct detection and counting of hybridized molecules. The digital response of the sensor provides a large dynamic range that is critical for gene expression profiling. We have measured differential expressions of microRNAs in tumour samples; such measurements have been shown to help discriminate between the tissue origins of metastatic tumours. Two hundred picograms of total RNA is found to be sufficient for this analysis. In addition, the limit of detection in pure samples is found to be one attomolar. These results suggest that nanomechanical read-out of microarrays promises attomolar-level sensitivity and large dynamic range for the analysis of gene expression, while eliminating biochemical manipulations, amplification and labelling.


Assuntos
DNA Complementar/genética , Perfilação da Expressão Gênica/métodos , Fenômenos Mecânicos , MicroRNAs/genética , Análise de Sequência com Séries de Oligonucleotídeos/métodos , Perfilação da Expressão Gênica/economia , Humanos , Hibridização de Ácido Nucleico , Análise de Sequência com Séries de Oligonucleotídeos/economia , Sensibilidade e Especificidade
5.
Biotechnol Bioeng ; 100(1): 19-27, 2008 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-18078298

RESUMO

The present study reports on the retention of conformational flexibility of a model allosteric protein upon immobilization on self-assembled monolayers (SAMs) on gold. Organothiolated SAMs of different compositions were utilized for adsorptive and covalent attachment of bovine liver glutamate dehydrogenase (GDH), a well-characterized allosteric enzyme. Sensitive fluorimetric assays were developed to determine immobilization capacity, specific activity, and allosteric properties of the immobilized preparations as well as the potential for repeated use and continuous catalytic transformations. The allosteric response of the free and immobilized forms towards ADP, L-leucine and high concentrations of NAD(+), some of the well-known activators for this enzyme, were determined and compared. The enzyme immobilized by adsorption or chemical binding responded similarly to the activators with a greater degree of activation, as compared to the free form. Also loss of activity involving the two immobilization procedures were similar, suggesting that residues essential for catalytic activity or allosteric properties of GDH remained unchanged in the course of chemical modification. A recently established method was used to predict GDH orientation upon immobilization, which was found to explain some of the experimental results presented. The general significance of these observations in connection with retention of native properties of protein structures upon immobilization on SAMs is discussed.


Assuntos
Materiais Revestidos Biocompatíveis/química , Glutamato Desidrogenase/química , Glutamato Desidrogenase/ultraestrutura , Ouro/química , Modelos Químicos , Modelos Moleculares , Adsorção , Animais , Sítios de Ligação , Bovinos , Simulação por Computador , Ativação Enzimática , Estabilidade Enzimática , Enzimas Imobilizadas/química , Ligação Proteica , Conformação Proteica
6.
Proc Natl Acad Sci U S A ; 103(17): 6466-70, 2006 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-16614066

RESUMO

Rapid, sequence-specific DNA detection is essential for applications in medical diagnostics and genetic screening. Electrical biosensors that use immobilized nucleic acids are especially promising in these applications because of their potential for miniaturization and automation. Current DNA detection methods based on sequencing by synthesis rely on optical readouts; however, a direct electrical detection method for this technique is not available. We report here an approach for direct electrical detection of enzymatically catalyzed DNA synthesis by induced surface charge perturbation. We discovered that incorporation of a complementary deoxynucleotide (dNTP) into a self-primed single-stranded DNA attached to the surface of a gold electrode evokes an electrode surface charge perturbation. This event can be detected as a transient current by a voltage-clamp amplifier. Based on current understanding of polarizable interfaces, we propose that the electrode detects proton removal from the 3'-hydroxyl group of the DNA molecule during phosphodiester bond formation.


Assuntos
Técnicas Biossensoriais/métodos , DNA/biossíntese , Sequência de Bases , Técnicas Biossensoriais/instrumentação , DNA/química , Eletroquímica , Eletrodos , Ouro , Cinética , Propriedades de Superfície
7.
Langmuir ; 21(7): 3096-103, 2005 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-15779990

RESUMO

Magnetic MFe2O4 (M = Fe, Co, or Mn) nanoparticles with uniform diameters in the 4-20 nm range and with excellent material properties, reported previously, can be rendered soluble in water or aqueous buffers using a combination of alkylphosphonate surfactants and other surfactants such as ethoxylated fatty alcohols or phospholipids. Surfactant-modified oligonucleotides can be incorporated into the particles' organic shell. The particles can withstand salt concentrations up to 0.3 M, temperatures up to 90 degrees C, and various operations such as concentration to dryness, column or membrane separations, and electrophoresis. The particles can be selectively hybridized to DNA-functionalized gold surfaces with high coverages using a two-story monolayer structure. These particles may find valuable applications involving the magnetic detection of small numbers of biomolecules using spin valves, magnetic tunnel junctions, or other sensors.


Assuntos
Cobalto/química , Sondas de DNA/química , DNA/química , Ferro/química , Manganês/química , Nanoestruturas/química , Alquilação , Ouro , Microscopia Eletrônica de Varredura , Microscopia Eletrônica de Transmissão , Estrutura Molecular , Nanoestruturas/ultraestrutura , Organofosfonatos/química , Análise Espectral , Propriedades de Superfície , Temperatura
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA