Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 54
Filtrar
2.
Artigo em Inglês | MEDLINE | ID: mdl-38052251

RESUMO

BACKGROUND: Reverse Potts shunt (RPS) and lung or heart-lung transplantation are life-extending surgical interventions for pediatric patients with severe pulmonary arterial hypertension (PAH). Robust criteria for identifying patients who will benefit from these procedures remain elusive. Based on 30 years of experience, we sought to refine the surgical indications. METHODS: This single-center retrospective cohort study included 61 consecutive pediatric patients with PAH managed by RPS (2004-2020) or transplantation (1988-2020). Their mid-term outcomes were assessed. RESULTS: Compared with the 20 patients managed by RPS, the 41 transplant waitlist patients, of whom 28 were transplanted, were older (14.9 vs 8.0 years, P = .0001), had worse right ventricular impairment (tricuspid annular plane systolic excursion, 12.5 mm vs 18.0 mm, P = .03), and were managed later in the evolution of the disease (6.0 vs 1.7 years, P = .002). After implementation of a high-priority allocation program in 2007, waitlist mortality decreased from 52.6% to 13.6% (P = .02) and 5-year survival increased from 57.1% to 74.7% after RPS and 55.6% to 77.2% after transplantation. At a median follow-up of 8.6 years after RPS and 5.9 years after transplantation, functional capacity had improved significantly, and PAH-specific drug requirements had diminished markedly in the RPS group. Two patients successfully underwent double-lung transplant 6 and 9 years after RPS. CONCLUSIONS: In selected children with suprasystemic PAH, RPS is associated with functional capacity improvements and decreased pharmacotherapy needs over the midterm. RPS deserves consideration earlier in the course of pediatric PAH, with transplantation being performed in the event of refractory RV failure.

3.
J Clin Med ; 12(24)2023 Dec 13.
Artigo em Inglês | MEDLINE | ID: mdl-38137725

RESUMO

INTRODUCTION: Percutaneous pulmonary valve implantation (PPVI) with a SAPIEN 3 valve is effective for treating treat right ventricle outflow (RVOT) dysfunction. A modified technique was developed without prestenting using a protective valve delivery method. We aimed to compare the procedural results of the modified technique group (MTG) to those of patients in a conventional technique group (CTG). METHODS: We designed a matched before-after study. All consecutive PPVI with SAPIEN 3 performed in the MTG over 9 months were matched, based on the RVOT type and size, to consecutive procedures performed previously with SAPIEN 3. RESULTS: A total of 54 patients were included, equally distributed in the two groups. The sizes of the SAPIEN 3 valves were 23 mm (n = 9), 26 mm (n = 9), 29 mm (n = 36). The two groups were similar regarding demographic data, RVOT type, and pre-procedure hemodynamics. PPVI was performed in a single procedure in all patients of the MTG, whereas six (22.2%) patients of the CTG group underwent prestenting as a first step and valve implantation later (p = 0.02). The procedures were successful in all cases. Stent embolization was reported in two patients (7.4%) in the CTG, which were impacted in pulmonary arteries. In one case (3.7%), in the MTG, an unstable 29 mm SAPIEN 3 valve was stabilized with two stents and additional valve-in-valve implantation. The hemodynamics results were good in all cases, without significant differences between the two groups. The procedures' durations and fluoroscopy times were significantly reduced in the MTG (48.1 versus 82.6 min, p < 0.0001; 15.2 versus 29.8 min, p = 0.0002). During follow-up, neither stent fracture nor valve dysfunction was noticed in either group. CONCLUSION: PPVI without prestenting and with a protective delivery method of the SAPIEN 3 valve significantly reduces the procedure's complexity, the duration, and the irradiation while maintaining excellent hemodynamics results in selected cases.

4.
Int J Cardiol ; 370: 156-166, 2023 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-36283540

RESUMO

BACKGROUND: Transcatheter pulmonary valve implantation (TPVI) is effective for treating right ventricle outflow tract (RVOT) dysfunction. Factors associated with long-term valve durability remain to be investigated. METHODS: Consecutive patients successfully treated by TPVI with Melody valves (n = 32) and SAPIEN valves (n = 182) between 2008 and 2020 at a single tertiary centre were included prospectively and monitored. RESULTS: The 214 patients had a median age of 28 years (range, 10-81). The RVOT was a patched native pulmonary artery in 96 (44.8%) patients. Median follow-up was 2.8 years (range, 3 months-11.4 years). Secondary pulmonary valve replacement (sPVR) was performed in 23 cases (10.7%), due to stenosis (n = 22, 95.7%) or severe regurgitation (n = 1, 4.3%), yielding an incidence of 7.6/100 patient-years with melody valves and 1.3/100 patient-years with SAPIEN valves (P = 0.06). The 5- and 10-year sPVR-freedom rates were 78.1% and 50.4% with Melody vs. 94.3% and 82.2% with SAPIEN, respectively (P = 0.06). The incidence of infective endocarditis (IE) was 5.5/100 patient-years with Melody and 0.2/100 patient-years with SAPIEN (P < 0.0001). Factors associated with sPVR by univariate analysis were RV obstruction before TPVI (P = 0.04), transpulmonary maximal velocity > 2.7 m/s after TPVI (p = 0.0005), valve diameter ≤ 22 mm (P < 0.003), IE (P < 0.0001), and age < 25 years at TPVI (P = 0.04). By multivariate analysis adjusted for IE occurrence, transpulmonary maximal velocity remained associated with sPVR. CONCLUSIONS: TPVI is effective for treating RVOT dysfunction. Incidence of sPVR is higher in patients with residual RV obstruction or IE. IE add a substantial risk of TPVI graft failure and is mainly linked to the Melody valve. SOCIAL MEDIA ABSTRACT: Transcatheter pulmonary valve implantation is effective for treating right ventricular outflow tract dysfunction in patients with congenital heart diseases. Incidence of secondary valve replacement is higher in patients with residual obstruction or infective endocarditis.


Assuntos
Endocardite Bacteriana , Endocardite , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Pulmonar , Valva Pulmonar , Humanos , Criança , Adolescente , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Próteses Valvulares Cardíacas/efeitos adversos , Cateterismo Cardíaco/efeitos adversos , Resultado do Tratamento , Endocardite/epidemiologia , Endocardite Bacteriana/etiologia , Desenho de Prótese , Insuficiência da Valva Pulmonar/cirurgia , Estudos Retrospectivos
5.
Cardiol Young ; 33(2): 294-300, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35272729

RESUMO

BACKGROUND: Anxiety before an invasive intervention is associated in children with persistent psychological disorders. We studied the effect of the transfer to the catheterisation room by an electric toy car on the anxiety of children and their parents before a cardiac catheterisation. METHODS: Forty-eight children with a median age of 5.6 years [4.2-7.0] were randomised to either riding on an electric car to go to the catheterisation laboratory or being transported lying supine on a gurney. Anxiety assessments were performed by a physician blinded to group allocation on the day before the procedure (T0) and at anaesthesia induction (T1). The modified Yale Preoperative Anxiety Scale Short Form (mYPAS-SF) and visual analogue scale for anxiety (VAS-A) were used in the children and the VAS-A in the parents. RESULTS: The mYPAS-SF, VAS-A-child, and the VAS-A-parent scores were significantly higher at T1 than at T0 (p < 0.001, p < 0.001, and p = 0.005, respectively). The primary outcome (the median mYPAS-SF score at T1) was not significantly different in the two groups when males and females were combined. At T1, the VAS-A-child score, however, was significantly lower in the intervention than the control group (22 versus 55, p < 0.001). In the boys, the median mYPAS-SF score at T1 was significantly lower in the intervention group (25.0 versus 51.0, p = 0.024). No difference was observed in girls. The VAS-A parent score was lower at T1 in the intervention group (60 versus 87, p = 0.05). CONCLUSION: Riding to the catheterisation laboratory on an electric toy car decreased anxiety in boys and decreased parental anxiety.


Assuntos
Ansiedade , Automóveis , Masculino , Feminino , Humanos , Pré-Escolar , Ansiedade/prevenção & controle , Ansiedade/psicologia , Anestesia Geral
6.
Environ Pollut ; 312: 120028, 2022 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-36030963

RESUMO

Eighty eight adult gardeners and their relatives volunteered to provide urine and blood samples for a human biomonitoring survey among users of one of the biggest allotment garden from Wallonia, showing high trace metal(oid) concentrations in soils. The purpose was to determine if environmental levels of lead (Pb), cadmium (Cd) and arsenic (As) led to concentrations of potential health concern in the study population. Blood and urine biomarkers were compared to reference and intervention cut-off values selected from the literature. The study population exhibited (i) moderately high blood lead levels with median value of 23.1 µg/L, (ii) high urinary concentrations of speciated As (inorganic arsenic and its metabolites) with a median value of 7.17 µg/g.cr., i.e. twice the median values usually observed in general populations, and (iii) very high Cd levels in urine with a median value of 1.23 µg/L, in the range of 95th-97.5th percentiles measured in general adult populations. Biomarker levels in the study population were also mostly above those measured in adults from local populations living on contaminated soils, as reported in the current literature. All biomarkers of Pb, Cd and As showed weak to strong statistically significant correlations, pointing towards a joint environmental source to these three contaminants as being at least partially responsible for the high exposure levels observed. Urine and blood biomarkers show statistically significant associations with variables related to individual characteristics (age, smoking status, …) and Pb domestic sources (Pb pipes, cosmetics, …) but involves also behavioral and consuming habits related to gardening activities on the contaminated allotment garden. At such levels, owing to co-exposure and additive effects of Cd, As and Pb regarding renal toxicity known from literature, the study strongly suggests that this population of gardeners is at risk with respect to chronic kidney diseases.


Assuntos
Arsênio , Metais Pesados , Poluentes do Solo , Adulto , Arsênio/análise , Monitoramento Biológico , Cádmio/análise , Monitoramento Ambiental/métodos , Humanos , Chumbo/análise , Metais Pesados/análise , Solo , Poluentes do Solo/análise , Zinco/análise
7.
JACC Clin Electrophysiol ; 8(3): 331-340, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-35331427

RESUMO

OBJECTIVES: This study aimed to assess the incidence, associated factors, and outcomes of atrial arrhythmias in adults with atrioventricular septal defect (AVSD). BACKGROUND: Data regarding atrial arrhythmias in adults with AVSD are particularly scarce. METHODS: Data were analyzed from a multicentric cohort of adult patients with AVSD. Lifetime cumulative incidences of atrial arrhythmias were studied. Multiple logistic regression models were used to identify risk factors. RESULTS: A total of 391 patients (61.6% women) were enrolled with a mean age of 36.3 ± 16.3 years and a mean follow-up of 17.3 ± 14.2 years after initial surgical repair. Overall, 98 patients (25.1%) developed at least 1 episode of atrial arrhythmia at a mean age of 39.2 ± 17.2 years. The mean ages of patients at first episode of intra-atrial re-entrant tachycardia (IART)/ focal atrial tachycardia (FAT) and atrial fibrillation were 33.7 ± 15.3 and 44.3 ± 16.5 years, respectively. The lifetime risks for developing atrial arrhythmia to ages 20, 40, and 60 years were 3.7%, 17.8%, and 55.3%, respectively. IART/FAT was the leading arrhythmia until the age of 45, then atrial fibrillation surpassed IART/FAT. Age (odds ratio [OR]: 1.4; 95% confidence interval [CI]: 1.2-1.6), number of cardiac surgeries (OR: 4.1; 95% CI: 2.5-6.9), left atrial dilatation (OR: 3.1; 95% CI: 1.4-6.8), right atrial dilatation (OR: 4.1; 95% CI: 1.7-10.3), and moderate or severe left atrioventricular valve regurgitation (OR: 3.7; 95% CI: 1.2-11.7) were independently associated with a higher risk of atrial arrhythmias, whereas the type of AVSD and the age at repair were not. The occurrence of atrial arrhythmias was associated with pacemaker implantation (41.8% vs. 8.5%; P < 0.001), heart failure (24.5% vs. 1.0%; P < 0.001), and cerebrovascular accidents (11.2% vs. 3.4%; P = 0.007). CONCLUSIONS: The lifetime risk of atrial arrhythmias in patients with AVSD is considerable with more than half of patients developing ≥1 atrial arrhythmia by the age of 60 and is associated with a significant morbidity. The risk in partial/intermediate AVSD is as high as in complete AVSD and is not impacted by age at repair.


Assuntos
Fibrilação Atrial , Taquicardia Supraventricular , Adulto , Fibrilação Atrial/complicações , Fibrilação Atrial/epidemiologia , Feminino , Defeitos dos Septos Cardíacos , Comunicação Interventricular , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Taquicardia Supraventricular/etiologia , Adulto Jovem
8.
Epilepsy Behav ; 126: 108486, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34929474

RESUMO

OBJECTIVE: To assess the relation between coffee consumption and seizure frequency in patients with drug-resistant focal epilepsy. METHODS: Cross-sectional analysis of data collected in the SAVE study, which included patients with drug-resistant focal epilepsy during long-term EEG monitoring. Patients in whom both coffee consumption and data about seizure frequency, including focal to bilateral tonic-clonic seizures (FBTCS), were available were selected. Coffee consumption was collected using a standardized self-report questionnaire and classified into four groups: none, rare (from less than 1 cup/week to up 3 cups/week), moderate (from 4 cups/week to 3 cups/day), and high (more than 4 cups/day). RESULTS: Six hundred and nineteen patients were included. There was no relation between coffee consumption and total seizure frequency (p = 0.902). In contrast, the number of FBTCS reported over the past year was significantly associated with usual coffee consumption (p = 0.029). Specifically, number of FBCTS in patients who reported moderate coffee consumption was lower than in others. In comparison with patients with moderate coffee consumption, the odds ratio (95%CI) for reporting at least 1 FBTCS per year was 1.6 (1.03-2.49) in patients who never take coffee, 1.62 (1.02-2.57) in those with rare consumption and 2.05 (1.24-3.4) in those with high consumption. Multiple ordinal logistic regression showed a trend toward an association between coffee consumption and number of FBTCS (p = 0.08). CONCLUSIONS AND RELEVANCE: Our data suggest that effect of coffee consumption on seizures might depend on dose with potential benefits on FBTCS frequency at moderate doses. These results will have to be confirmed by prospective studies.


Assuntos
Café , Epilepsias Parciais , Anticonvulsivantes/uso terapêutico , Estudos Transversais , Epilepsias Parciais/tratamento farmacológico , Epilepsias Parciais/epidemiologia , Humanos , Estudos Prospectivos , Convulsões/tratamento farmacológico , Convulsões/epidemiologia
9.
Environ Geochem Health ; 44(11): 3853-3861, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34714462

RESUMO

This study presents an alternative method to the traditional reference dose approach for the determination of health risk-based soil standards for arsenic. The model combines multimedia equations for air, soil and dietary exposure, a toxicokinetic component, a probabilistic output, a reference distribution for urine arsenic in the general population and exposure parameters values traceable in US-EPA or EFSA reference studies. The model calculates a mean inorganic As urine concentration AsU (sum of inorganic arsenic Asi and its metabolites) from environmental data and exposure parameters, which is attributed to the central value of a lognormal distribution. Risk is assessed by comparing a high percentile of the modelled distribution to the target AsU attributed to the reference value of 10 µg/gCREA (microgram As per gram of creatinine), the upper confidence interval of the 95th percentile from the AsU distribution in the French population. A soil standard value of 40 mg/kg is determined as being the arsenic concentration in soil not giving rise to more than 5% probability of having a AsU concentration above the target value of 10 µg/gCREA. Once soil As concentrations above 40 mg/kg are measured, further environmental investigations should be carried, involving an assessment of As bioaccessibility to address health risks and decide of regulatory measures in residential setting.


Assuntos
Arsênio , Humanos , Arsênio/toxicidade , Arsênio/análise , Solo , Creatinina , Toxicocinética , Exposição Ambiental/análise
10.
Am J Dent ; 34(4): 186-189, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34370909

RESUMO

PURPOSE: To compare two methods used by novice and expert operators for selecting interdental brush (IDB) size for periodontitis patients: (1) sequential testing or (2) using a color-coded taper tip device (CTD) corresponding to color-coded brush sizes. METHODS: Six operators, one experienced and five dental students, employed both methods to determine the IDB with best fit for 204 interdental spaces in 34 periodontitis patients. The percentage of agreement and the inter-methods reliability was evaluated. The influence of anatomical features on differences between the operators or method was also investigated. RESULTS: Moderate to substantial correlation was found between the two methods but the reliability was stronger when different operators used the same method, irrespective of the method, than when they used a different method. Among the anatomical factors studied, only sites in molar regions were associated with significant differences. CLINICAL SIGNIFICANCE: Use of a dedicated color-coded taper tip may be an alternative to the fastidious sequential testing of different IDB in selecting best-fit IDB diameter for periodontal patients with moderate to broad interdental spaces.


Assuntos
Placa Dentária , Periodontite , Dispositivos para o Cuidado Bucal Domiciliar , Humanos , Reprodutibilidade dos Testes , Escovação Dentária
11.
Catheter Cardiovasc Interv ; 98(5): 990-999, 2021 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-34227735

RESUMO

OBJECTIVES: This study sought to investigate patient intermediate-term outcomes after transcatheter pulmonary valve replacement (TPVR) with Edwards SAPIEN valve. BACKGROUND: The Edwards SAPIEN valve, initially designed for percutaneous aortic valve replacement, has been approved for TPVR in patients with dysfunctional right ventricular outflow tracts (RVOT), but only short-term follow-up has been reported. METHODS: From 2011 to 2016, 62 patients undergoing successful TPVR using the SAPIEN XT valve were consecutively included into the study. Primary efficacy and safety endpoints were defined as freedom from valve-reintervention and freedom from infective endocarditis at last follow-up, respectively. RESULTS: The primary efficacy outcome was met for 87.1% patients after a mean follow-up of 4.6 ± 1.8 years, corresponding to a freedom of reintervention at 5 years of 89% (95% CI 74.8-95.6%). Reinterventions were exclusively due to recurrent obstruction, no significant valvular regurgitation was observed. One case of infective endocarditis was reported, corresponding to a rate of 0.35% per patient-year (95% CI 0.01-2.00%). At 5 years, freedom from infective endocarditis was 98.4% (95% CI 89.1-99.8%). Six patients died or were transplanted due to advanced cardiac failure, without relationship with TPVR. In univariate analysis, reintervention was associated with young age, a smaller tube-graft, a higher pulmonary valve gradient after the procedure and a ratio of largest implanted stent diameter to invasive balloon conduit diameter over 1.35. CONCLUSIONS: This study documents the mid-term safety and efficacy of the Edwards SAPIEN XT valve in patients with dysfunctional RVOT, and identifies a patient profile associated with an uncertain benefit-risk balance.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Valva Pulmonar , Obstrução do Fluxo Ventricular Externo , Cateterismo Cardíaco/efeitos adversos , Seguimentos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Desenho de Prótese , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/cirurgia , Sistema de Registros , Resultado do Tratamento , Obstrução do Fluxo Ventricular Externo/cirurgia
12.
Epilepsy Behav ; 116: 107795, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33545653

RESUMO

The aim of the study was to develop a new conceptual framework of empowerment based upon the perspective of patients with refractory epilepsy at the medical-social center of La Teppe (France). A qualitative research methodology was used, which consisted of focused ethnography and in-depth interviews. The 19 patients interviewed came from three hospital services and were in the age range of 20-60. Ten interviews were also conducted with healthcare providers, which included neurologists, psychiatrists, nurses, and social educators. Results were analyzed via an intuitive process of thematic analysis. The researcher also constructed narrative cases of the patient interview to better understand patient responses in context. The results show that patients understood empowerment as the ability to develop and take advantage of opportunities in their overall lives. This included searching to be healthy by reducing their seizures, developing their practical reason in order to be able to make more autonomous life choices, and living with and toward others in positive social relationships. The patient's perspective on empowerment encompasses but also goes beyond their medical care. We therefore propose a novel conceptual framework for empowerment as the patient's capabilities to develop and make their life choices, with help as needed from their support network. In order to help patients toward empowerment, clinical care can include discussions and dedicate resources that help patients work toward their overall life projects. Several methodologies, including the use of a personalized project and therapeutic patient education, are elaborated to give ideas for empowerment programming in epilepsy care.


Assuntos
Epilepsia , Participação do Paciente , Empoderamento , Epilepsia/terapia , França , Hospitais , Humanos
13.
Arch Cardiovasc Dis ; 113(8-9): 513-524, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32680737

RESUMO

BACKGROUND: Closure of patent foramen ovale is well-managed in adults, but is performed less frequently in children. AIM: To analyse all patent foramen ovale closures performed in the past 20 years in French paediatric centres. METHODS: Retrospective study of patent foramen ovale closures in children without cardiopathy in nine centres between 2000 and 2019. RESULTS: Forty-one procedures were carried out in children (median age: 14.9 years). Thirty-one patent foramen ovales were closed after a transient ischaemic attack or stroke, six for a left-to-right shunt and four for other reasons. Transthoracic echocardiography was used for 72.2% of the diagnoses and transoesophageal echocardiography for 27.8%. A substantial degree of shunting was found in 42.9% of patients and an atrial septal aneurysm in 56.2%. General anaesthesia with transoesophageal echocardiography guidance was performed in 68.3% of the procedures; local anaesthesia and transthoracic echocardiography or intracardiac echocardiography was performed in 31.7%. The success rate was 100%. The median fluoroscopy time was 4.14minutes: 3.55minutes with transoesophageal echocardiography; and 4.38minutes with transthoracic echocardiography (P=0.67). There was only one periprocedural complication (2.4%). Postoperatively, 80,5% of patients were treated with aspirin and 12,2% with an anticoagulant. The rate of complete occlusion was 56.8% immediately after the procedure, 68.6% at 1 year and 92.3% at the last follow-up. There were no delayed complications or cases of recurrent stroke during follow-up (median follow-up: 568 days). CONCLUSION: Closure of patent foramen ovale in children appears to be safe and effective, as we noted a low rate of immediate complications, no delayed complications and no stroke recurrence in this indication.


Assuntos
Cateterismo Cardíaco/instrumentação , Forame Oval Patente/terapia , Dispositivo para Oclusão Septal , Adolescente , Fatores Etários , Cateterismo Cardíaco/efeitos adversos , Feminino , Forame Oval Patente/complicações , Forame Oval Patente/diagnóstico por imagem , França , Humanos , Ataque Isquêmico Transitório/etiologia , Masculino , Recidiva , Estudos Retrospectivos , Fatores de Risco , Acidente Vascular Cerebral/etiologia , Fatores de Tempo , Resultado do Tratamento
14.
Arch Cardiovasc Dis ; 113(2): 113-120, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32081640

RESUMO

BACKGROUND: The indications for percutaneous pulmonary valve implantation (PPVI) have been extended to include large dysfunctional right ventricular outflow tracts (RVOTs). Prestenting of the RVOT is commonly performed before PPVI in order to ensure a stable landing zone. The AndraStent XXL (AndraMed GmbH, Reutlingen, Germany), a cobalt-chromium stent with semi-open cell design, has unique mechanical properties in this indication but is no longer available in France. AIMS: To assess the efficiency of AndraStent XXL before PPVI. METHODS: In this retrospective multicentre cohort study, 86 AndraStents XXL were implanted in 77 patients in 6 centres. RESULTS: PPVI was indicated mainly for pulmonary regurgitation (75.3%) in native or patched RVOT (88.3%). The stents were manually mounted on balloon catheters and delivered through sheaths using a conventional femoral approach. PPVI was performed successfully in 97.4% of patients after successful prestenting, generally during the same procedure (77.9%). There were no deaths associated with stent implantation, and four patients experienced five complications, mainly stent embolization, including one requiring surgery. Neither stent fracture nor dysfunction were observed in any patient during a mean follow-up of 19.2±8.7months. Stent analysis showed an excellent maximal stent expansion (97.1%) regardless of balloon size. A 22.3%±3.4 stent shortening with a 30mm balloon was observed. CONCLUSIONS: Implantation of large cobalt-chromium AndraStent XXL stents is efficient for prestenting before PPVI.


Assuntos
Cateterismo Cardíaco/instrumentação , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Insuficiência da Valva Pulmonar/cirurgia , Valva Pulmonar/cirurgia , Stents , Obstrução do Fluxo Ventricular Externo/terapia , Adolescente , Adulto , Cateterismo Cardíaco/efeitos adversos , Criança , Feminino , França , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/fisiopatologia , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/fisiopatologia , Recuperação de Função Fisiológica , Estudos Retrospectivos , Resultado do Tratamento , Obstrução do Fluxo Ventricular Externo/diagnóstico por imagem , Obstrução do Fluxo Ventricular Externo/fisiopatologia , Adulto Jovem
15.
Arch Cardiovasc Dis ; 112(5): 323-333, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30797733

RESUMO

BACKGROUND: Transcatheter pulmonary valvuloplasty in neonates with pulmonary atresia and intact ventricular septum (PA-IVS) or duct-dependent pulmonary valve stenosis (DD-PVS) has become a reasonable alternative to surgical right ventricle decompression. AIM: To investigate mid-term outcomes following pulmonary valvuloplasty. METHODS: Sixty-five neonates with PA-IVS (n=29) or DD-PVS (n=36) (median age 4 days; mean weight 3.0kg) undergoing pulmonary valvuloplasty were reviewed retrospectively. Procedural data and clinical outcomes were assessed. RESULTS: Pulmonary valvuloplasty was successful in 59 patients (90.8%). Preterm birth, larger tricuspid valve annulus diameter and PA-IVS correlated with procedural failure. Eleven patients (18.6%) required a Blalock-Taussig shunt during early follow-up, despite valvuloplasty. These neonates had smaller tricuspid and pulmonary valve annulus Z-scores (-1.9 vs. -0.8 [p=0.04] and -2.5 vs. -0.9 [P=0.005], respectively) and a higher incidence of "bipartite" right ventricle (P=0.02). Mean follow-up was 5.4±3.3 years. Mortality after successful valvuloplasty was 8.5% (n=5). Among the 54 survivors, biventricular repair was achieved in 52 patients (96.3%), including nine with a previous Blalock-Taussig shunt. The cumulative rate of subsequent surgery (excluding Blalock-Taussig shunt) was 13.7% (95% confidence interval 6.8-26.7%) and 16.4% (95% confidence interval 8.5-30.4%) at 2 and 4 years, respectively. Secondary surgery was significantly more frequent in PA-IVS compared with DD-PVS, and in neonates with a Blalock-Taussig shunt (P=0.003 and 0.01, respectively). CONCLUSIONS: Selected neonates with DD-PVS or PA-IVS managed by transcatheter pulmonary valvuloplasty had a good mid-term outcome. In neonates with a borderline small right ventricle, a hybrid strategy with a supplementary source of pulmonary blood flow can be efficient to achieve biventricular repair.


Assuntos
Valvuloplastia com Balão/métodos , Cateterismo Cardíaco/métodos , Cardiopatias Congênitas/terapia , Atresia Pulmonar/terapia , Valva Pulmonar/anormalidades , Fatores Etários , Valvuloplastia com Balão/efeitos adversos , Valvuloplastia com Balão/mortalidade , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/mortalidade , Bases de Dados Factuais , Feminino , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/mortalidade , Cardiopatias Congênitas/fisiopatologia , Hemodinâmica , Humanos , Recém-Nascido , Masculino , Atresia Pulmonar/diagnóstico por imagem , Atresia Pulmonar/mortalidade , Atresia Pulmonar/fisiopatologia , Circulação Pulmonar , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/fisiopatologia , Recuperação de Função Fisiológica , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
17.
Circ Cardiovasc Interv ; 11(11): e006765, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30571202

RESUMO

Background Children treated with cardiac catheterization procedures have now a long life expectancy and consequently potential long-term radiation-induced risks. We projected lifetime attributable risks (LARs) of cancer incidence from the most frequent procedures in pediatrics: atrial septal defect closure, patent ductus arteriosus occlusion, or pulmonary valvuloplasty. Methods and Results Organ equivalent doses were estimated for 1251 procedures performed in children aged ≤15 years at 2 reference catheterization centers in France from 2009 to 2013. Sex-specific LARs were projected in lifelong nonsmokers using extended Committee on Biological Effects of Ionizing Radiation VII risk models and considering various sources of risk projection uncertainties and dose variability (Radiation Risk Assessment Tool software). Median LARs ranged between 0.3 and 1.4 (atrial septal defect closure), 0.6 and 5.0 (patent ductus arteriosus occlusion), and 1.0 and 12.0 (pulmonary valvuloplasty) per 1000 procedures, depending on patient sex and age at treatment. These radiation-related risks would represent 0.4% to 6.0% of children's total lifetime cancer risk. For the 10% of procedures (all types combined) with highest exposures, LARs reached 4.2 per 1000 (95% uncertainty interval, 0.8-13.1) in boys and 22.2 per 1000 (95% uncertainty interval, 7.4-45.6) in girls. In boys, lung cancer accounted for 70% to 80% of the projected LARs, whereas in girls it accounted for 20% to 60% and breast cancer for 30% to 80% of the excess risks, depending on the type of procedure and patient age. Conclusions Radiation exposure may lead to substantial radiation doses and increased cancer risks in some cases. This suggests the need for dose reporting to support recommendations for long-term surveillance and prevention strategies when it is necessary.


Assuntos
Cateterismo Cardíaco/efeitos adversos , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/terapia , Neoplasias Induzidas por Radiação/epidemiologia , Exposição à Radiação/efeitos adversos , Radiografia Intervencionista/efeitos adversos , Adolescente , Idade de Início , Feminino , Fluoroscopia/efeitos adversos , França/epidemiologia , Cardiopatias Congênitas/epidemiologia , Humanos , Incidência , Masculino , Neoplasias Induzidas por Radiação/diagnóstico , Doses de Radiação , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
18.
JACC Cardiovasc Interv ; 11(19): 1909-1916, 2018 10 08.
Artigo em Inglês | MEDLINE | ID: mdl-30219326

RESUMO

OBJECTIVES: The aim of this study was to describe and analyze data from patients treated in France with the Edwards SAPIEN transcatheter heart valve (Edwards Lifesciences LLC, Irvine, California) in the pulmonary position. BACKGROUND: The Edwards SAPIEN valve has recently been introduced for percutaneous pulmonary valve implantation (PPVI). METHODS: From April 2011 to May 2017, 71 patients undergoing PPVI were consecutively included. RESULTS: The median age at PPVI was 26.8 years (range 12.8 to 70.1 years). Primary underlying diagnoses were conotruncal malformations (common arterial trunk, tetralogy of Fallot and variants; n = 45), Ross procedure (n = 18), and other diagnoses (n = 8). PPVI indication was pure stenosis in 33.8% of patients, pure regurgitation in 28.1%, and mixed lesions in 38.1%. PPVI was successfully implemented in 68 patients (95.8%). Pre-stenting of the right ventricular outflow tract was performed in 70 patients (98.6%). Early major complications occurred in 4 subjects (5.6%), including 1 death, 1 coronary compression, and 2 pulmonary valve embolizations. Three of the 4 major complications occurred in the first 15 operated patients. No significant regurgitation was recorded after the procedure. Transpulmonary gradient was significantly reduced from 34.5 to 10.5 mm Hg (p < 0.0001). No patient died during a 1-month follow-up period. At 1-year follow-up, the death rate was 2.9%, and 3 patients had undergone surgical reintervention (44%). CONCLUSIONS: Early results with the Edwards SAPIEN valve in the pulmonary position demonstrate an ongoing high rate of procedural success.


Assuntos
Cateterismo Cardíaco/instrumentação , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Insuficiência da Valva Pulmonar/cirurgia , Estenose da Valva Pulmonar/cirurgia , Valva Pulmonar/cirurgia , Adolescente , Adulto , Idoso , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/mortalidade , Criança , Feminino , França , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/mortalidade , Estudos Prospectivos , Desenho de Prótese , Valva Pulmonar/anormalidades , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/fisiopatologia , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/mortalidade , Insuficiência da Valva Pulmonar/fisiopatologia , Estenose da Valva Pulmonar/diagnóstico por imagem , Estenose da Valva Pulmonar/mortalidade , Estenose da Valva Pulmonar/fisiopatologia , Recuperação de Função Fisiológica , Sistema de Registros , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
19.
Int J Cardiol ; 267: 84-87, 2018 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-29871810

RESUMO

BACKGROUND: Atrial septal defects (ASDs) can be symptomatic in small children in cases of co-morbidities. Transcatheter closure remains controversial for large defects in small children. OBJECTIVE: To describe transcatheter closure of ASDs in children with device/weight ratio ≥1.5. METHODS: We retrospectively studied between January 2000 and January 2016 all cases of percutaneous ASD closure with device/weight ratio ≥1.5 in 6 European centres. RESULTS: Forty patients were included with female/male ratio of 1.2. Median age and weight were 30.9 months (4.1-102.0) and 11.0 kg respectively (3.8-19.0). Median device size/weight ratio was 1.7 (1.5-2.3). All patients were symptomatic, with pulmonary hypertension in 13 (33%). Procedures were performed under general anesthesia or light sedation (n = 4), with transthoracic (n = 25) or transesophageal echocardiography (n = 15) guidance. Balloon stretched diameter (n = 32) was larger than the echocardiographic diameter (19 versus 15 mm, R = 0.6; p < 0.001). Deficient rims other than the anterior-superior one were found in 33% of cases. Device implantation was successful in 39 patients (97.5%). Minor complications occurred in 10% of cases, whereas severe complications rate was 5%: Complete atrioventricular block in one patient that resolved after surgical extraction of the device and thrombosis in the inferior vena cava in one patient. During a median follow-up of 52 months, there was no residual shunt. No case of erosion or embolization was reported and pulmonary hypertension resolved in all patients. CONCLUSION: Percutaneous closure of large ASD in small and symptomatic children is feasible and allows clinical improvement with acceptable rate of complications in high risk population.


Assuntos
Cateterismo Cardíaco/métodos , Comunicação Interatrial , Complicações Pós-Operatórias , Implantação de Prótese , Dispositivo para Oclusão Septal , Criança , Pré-Escolar , Ecocardiografia/métodos , Desenho de Equipamento , Estudos de Viabilidade , Feminino , França , Comunicação Interatrial/diagnóstico , Comunicação Interatrial/fisiopatologia , Comunicação Interatrial/cirurgia , Humanos , Lactente , Masculino , Avaliação de Resultados em Cuidados de Saúde , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/terapia , Desenho de Prótese , Implantação de Prótese/efeitos adversos , Implantação de Prótese/instrumentação , Implantação de Prótese/métodos , Estudos Retrospectivos , Índice de Gravidade de Doença , Cirurgia Assistida por Computador/métodos , Ultrassonografia de Intervenção/métodos
20.
JACC Cardiovasc Interv ; 11(8): 795-804, 2018 04 23.
Artigo em Inglês | MEDLINE | ID: mdl-29673513

RESUMO

OBJECTIVES: This study sought to assess procedural characteristics, early clinical outcome, and long-term complications after transcatheter closure of atrial septal defect (ASD) in children. BACKGROUND: Transcatheter closure has become the preferred strategy in most cases of isolated secundum ASD. However, reported experience in the pediatric population is limited. METHODS: A 1998 to 2016 retrospective multicenter study was performed in 9 French tertiary institutions. All children who had an attempt of percutaneous ASD closure with an Amplatzer Septal Occluder were included. RESULTS: In 1,326 children (39% males; median age, 9 years [0.7 to 18]; weight, 29 kg [3.6 to 92]), transcatheter ASD closure was performed. Median ASD size was 15 mm (3 to 41); 254 (19.1%) patients had a large ASD (≥20 mm/m2). Procedural success rate was 95.3% (95% confidence interval: 93.9% to 96.3%). No death was observed but periprocedural complications occurred in 24 patients (1.8%). After a median follow-up of 3.5 years (range 6 months to 18 years; 173 patients [13%] followed >10 years), delayed major complications were minimal (n = 12; 1.04%) including no death and/or cardiac erosion. Periprocedural and delayed complications rates were significantly higher in children ≤15 kg (5.2% vs. 1.5%; p = 0.007 and 3.1% vs. 0.7%; p < 0.007, respectively) and those with large ASD (3.5% vs. 1.4%; p = 0.008 and 1.7% vs. 0.7%; p = 0.052, respectively). CONCLUSIONS: Transcatheter ASD closure using Amplatzer Septal Occluder is safe in children with a minimal rate of periprocedural complications and a favorable long-term outcome, especially with no death or cardiac erosion despite a substantial proportion of large defects. Children ≤15 kg and those with large ASDs had a greater risk of complications.


Assuntos
Cateterismo Cardíaco , Comunicação Interatrial/terapia , Adolescente , Fatores Etários , Peso Corporal , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Criança , Pré-Escolar , Feminino , França , Comunicação Interatrial/diagnóstico por imagem , Comunicação Interatrial/fisiopatologia , Humanos , Lactente , Masculino , Estudos Retrospectivos , Fatores de Risco , Dispositivo para Oclusão Septal , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA