Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Eur J Anaesthesiol ; 37(11): 1032-1039, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32371830

RESUMO

BACKGROUND: The creation of pneumoperitoneum during laparoscopic surgery can lead to adverse effects on the respiratory system. Positive end-expiratory pressure (PEEP) plays an important role in mechanical ventilation during laparoscopic surgery. OBJECTIVE: To evaluate whether PEEP setting guided by oesophageal pressure (Poeso) measurement would affect oxygenation and respiratory mechanics during laparoscopic gynaecological surgery. DESIGN: A randomised controlled study. SETTING: A single-centre trial from March 2018 to June 2018. PATIENTS: Forty-four adult patients undergoing laparoscopic gynaecological surgery with anticipated duration of surgery more than 2 h. INTERVENTION: PEEP set according to Poeso measurement (intervention group) versus PEEP constantly set at 5 cmH2O (control group). MAIN OUTCOME MEASURES: Gas exchange and respiratory mechanics after induction and intubation (T0) and at 15 and 60 min after initiation of pneumoperitoneum (T1 and T2, respectively). RESULTS: PEEP during pneumoperitoneum was significantly higher in the intervention group than in the control group (T1, 12.5 ±â€Š1.9 vs. 5.0 ±â€Š0.0 cmH2O and T2, 12.4 ±â€Š1.9 vs. 5.0 ±â€Š0.0 cmH2O, both P < 0.001). Partial pressures of oxygen decreased significantly from baseline during pneumoperitoneum in the control group but not in the intervention group. Nevertheless, the changes in partial pressures of oxygen did not differ between groups. Compliance of the respiratory system (CRS) significantly decreased and driving pressure significantly increased during pneumoperitoneum in both groups. However, the changes in CRS and driving pressure were significantly less in the intervention group. Transpulmonary pressure during expiration was maintained in the intervention group while it decreased significantly in the control group. CONCLUSION: PEEP setting guided by Poeso measurement showed no beneficial effects in terms of oxygenation but respiratory mechanics were better during laparoscopic gynaecological surgery. TRIAL REGISTRATION: ClinicalTrials.gov identifier: NCT03256396.


Assuntos
Laparoscopia , Mecânica Respiratória , Adulto , Feminino , Procedimentos Cirúrgicos em Ginecologia , Humanos , Respiração com Pressão Positiva , Respiração Artificial
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA