Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Biosens Bioelectron ; 215: 114551, 2022 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-35839622

RESUMO

Monitoring food freshness/spoilage is important to ensure food quality and safety. Current methods of food quality monitoring are mostly time-consuming and labor intensive processes that require massive analytical equipment. In this study, we developed a portable bioelectronic nose (BE-nose) integrated with trace amine-associated receptor (TAAR) nanodiscs (NDs), allowing food quality monitoring via the detection of food spoilage indicators, including the biogenic amines cadaverine (CV) and putrescine (PT). The olfactory receptors TAAR13c and TAAR13d, which have specific affinities for CV and PT, were produced and successfully reconstituted in ND structures. TAAR13 NDs BE-nose-based side-gated field-effect transistor (SG-FET) system was constructed by utilizing a graphene micropattern (GM) into which two types of olfactory NDs (TAAR13c ND and TAAR13d ND) were introduced, and this system showed ultrahigh sensitivity for a limit of detection (LOD) of 1 fM for CV and PT. Moreover, the binding affinities between the TAAR13 NDs and the indicators were confirmed by a tryptophan fluorescence quenching assay and biosimulations, in which the specific binding site was confirmed. Gas-phase indicators were detected by the TAAR13 NDs BE-nose platform, and the LODs for CV and PT were confirmed to be 26.48 and 7.29 ppb, respectively. In addition, TAAR13 NDs BE-nose was fabricated with commercial gas sensors as a portable platform for the measurement of NH3 and H2S, multiplexed monitoring was achieved with similar performance, and the change ratio of the indicators was observed in a real sample. The integration of commercial gas sensors on a BE-nose enhanced the accuracy and reliability for the quality monitoring of real food samples. These results indicate that the portable TAAR13 NDs BE-nose can be used to monitor CV and PT over a wide range of concentrations, therefore, the electronic nose platform can be utilized for monitoring the freshness/spoilage step in various foods.


Assuntos
Técnicas Biossensoriais , Receptores Odorantes , Técnicas Biossensoriais/métodos , Cadaverina , Nariz Eletrônico , Putrescina , Receptores Odorantes/química , Reprodutibilidade dos Testes
2.
Biosens Bioelectron ; 200: 113908, 2022 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-34972042

RESUMO

Monitoring food spoilage is one of the most effective methods for preventing food poisoning caused by biogenic amines or microbes. Therefore, various analytical techniques have been introduced to detect low concentrations of cadaverine (CV) and putrescine (PT), which are representative biogenic polyamines involved in food spoilage (5-8 ppm at the stage of initial decomposition after storage for 5 days at 5 °C and 17-186 ppm at the stage of advanced decomposition after storage for 7 days at 5 °C). Although previous methods showed selective CV and PT detection even at low concentrations, the use of these methods remains challenging in research areas that require in-situ, real-time, on-site monitoring. In this study, we demonstrated for the first time an in-situ high-performance chemical receptor-conjugated graphene electronic nose (CRGE-nose) whose limits of detection (LODs), 27.04 and 7.29 ppb, for CV and PT are up to 102 times more sensitive than those of conventional biogenic amine sensors. Specifically, the novel chemical receptors 2,7-bis(3-morpholinopropyl)benzo[lmn][3,8] phenanthroline-1,3,6,8(2H,7H)-tetraone (NaPhdiMor (NPM)) and 2,7-bis(2-((3-morpholinopropyl)amino)ethyl)benzo[lmn][3,8]phenanthroline-1,3,6,8(2H,7H)-tetraone (NaPhdiEtAmMor (NPEAM)) were designed on the basis of density functional theory (DFT) calculations, and their interaction mechanism was characterized by a DFT 3D simulation. Interestingly, the CRGE-nose was connected on a micro sim chip substrate via wire bonding and then integrated into wireless portable devices, resulting in a cost-effective, high-performance prototype CRGE-nose device capable of on-site detection. The portable CRGE-nose can be used for in-situ monitoring of CV and PT concentration changes as low as 27.04 and 7.29 ppb in real meats such as pork, beef, lamb and chicken.


Assuntos
Técnicas Biossensoriais , Grafite , Animais , Aminas Biogênicas , Cadaverina , Bovinos , Nariz Eletrônico , Putrescina , Ovinos
3.
J Environ Sci (China) ; 103: 148-156, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33743897

RESUMO

Indoor air quality (IAQ) directly affects the health of occupants. Household manufacturing equipment (HME) used for hobbies or educational purposes is a new and unexplored source of air pollution. In this study, we evaluated the characteristics of particulate and gaseous pollutants produced by a household laser processing equipment (HLPE). Various target materials were tested using a commercial HLPE under various operating conditions of laser power and sheath air flow rate. The mode diameters of the emitted particles gradually decreased as laser power increased, while the particle number concentration (PNC) and particle emission rate (PER) increased. In addition, as the sheath air flow rate quadrupled from 10 to 40 L/min, the mode diameter of the emitted particles decreased by nearly 25%, but the effect on the PNC was insignificant. When the laser induced the target materials at 53 mW, the mode diameters of particles were <150 nm, and PNCs were >2.0 × 104 particles/cm3. Particularly, analyses of sampled aerosols indicated that harmful substances such as sulfur and barium were present in particles emitted from leather. The carcinogenic gaseous pollutants such as acrylonitrile, acetaldehyde, 1,3-butadiene, benzene, and C8 aromatics (ethylbenzene) were emitted from all target materials. In an actual indoor environment, the PNC of inhalable ultrafine particles (UFPs) was >5 × 104 particles/cm3 during 30 min of HLPE operation. Our results suggest that more meticulous control methods are needed, including the use of less harmful target materials along with filters or adsorbents that prevent emission of pollutants.


Assuntos
Poluentes Atmosféricos , Poluição do Ar em Ambientes Fechados , Poluentes Ambientais , Poluentes Atmosféricos/análise , Poluição do Ar em Ambientes Fechados/análise , Monitoramento Ambiental , Gases , Lasers , Tamanho da Partícula , Material Particulado/análise
4.
Lab Chip ; 20(18): 3435-3444, 2020 09 21.
Artigo em Inglês | MEDLINE | ID: mdl-32789372

RESUMO

In this work, a 3D-printed metal column was developed for micro gas chromatography (GC) applications and its properties and gas separation performances were characterized. By using a Ti6Al4V grade 23 powder, a square spiral one meter-long column (3D-column) was 3D-printed on a planar substrate of 3.4 × 3.3 × 0.2 cm and then perhydropolysilazane (PHPS) was deposited as a pre-treatment agent, followed by a coating of stationary phase (OV-1) onto the inner wall of the micro-channel. The 500 µm-diameter circular channel and two 800 µm-wide ports of the 3D-column were confirmed to be uniform by 3D X-ray microscopy without any distortion. The physical and thermal properties of the 3D-column were found to be very similar to that of the standard Ti6Al4V grade 23 alloy with near zero porosity (∼0.07%). The 3D-column with pre-treatment and stationary coating demonstrated efficient separation performance of gas mixtures containing alkanes, aromatics, alcohols, and ketones compared to a bare or only pretreated 3D-column in terms of the peak shape, broadening, and resolution (R > 1) within 2-3 min. The well-matched thermal responses to the target temperatures were demonstrated at the ramping rates of 10-20 °C min-1 upto 200 °C with uniform heat distribution over the 3D-column. In addition, the column bleed profiles showed that the 3D-column with PHPS had a 71% lower baseline intensity at 350 °C than that without PHPS. The 3D-column was then employed to separate a gas mixture of twelve alkanes (C9-C18, C22, C24) without any significant column bleeding and peak tailing. Therefore, the thermal responses and stability of the 3D-column promise its applicability in high temperature GC applications.

5.
Anal Chem ; 91(19): 12181-12190, 2019 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-31478373

RESUMO

Field-effect transistor (FET) devices based on conductive nanomaterials have been used to develop biosensors. However, development of FET-based biosensors that allow efficient stability, especially in the gas phase, for obtaining reliable and reproducible responses remains a challenge. In this study, we developed a nanodisc (ND)-functionalized bioelectronic nose (NBN) based on a nickel (Ni)-decorated carboxylated polypyrrole nanoparticle (cPPyNP)-FET that offers the detection of liquid and gaseous cadaverine (CV). The TAAR13c, specifically binding to CV, which is an indicator of food spoilage, was successfully constructed in NDs. The NBN was fabricated by the oriented assembly of TAAR13c-embedded NDs (T13NDs) onto the transistor with Ni/cPPyNPs. The NBN showed high performance in selectivity and sensitivity for the detection of CV, with excellent stability in both aqueous and gas phases. Moreover, the NBN allowed efficient measurement of corrupted real-food samples. It demonstrates the ND-based device can allow the practical biosensor that provides high stability in the gas phase.


Assuntos
Cadaverina/análise , Nariz Eletrônico , Nanopartículas/química , Técnicas Biossensoriais/instrumentação , Desenho de Equipamento , Escherichia coli/genética , Contaminação de Alimentos/análise , Gases/análise , Limite de Detecção , Níquel/química , Espectroscopia Fotoeletrônica , Polímeros/química , Pirróis/química , Receptores Odorantes/genética , Proteínas Recombinantes/química , Proteínas Recombinantes/genética , Sensibilidade e Especificidade , Transistores Eletrônicos , Proteínas de Peixe-Zebra/genética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA