Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-38520897

RESUMO

Extraction of vitamin D, including its hydroxylated and esterified metabolites, from soft tissues such as the liver is challenging due to the lipophilic character of matrix and analytes that are expected in very low concentration levels. In this study, we aimed at the optimization of two-step extraction using solid-liquid extraction as the first step, followed by solid-phase extraction. Various solvents, including ethanol, acetonitrile, methanol, acetone, heptane, and heptane with isopropanol, were investigated to isolate vitamin D compounds from liver tissue in the first step. Acetone was finally selected as the most suitable solvent for the solid-liquid extraction, with the highest recovery in the range of 67 - 98% for polar hydroxylated forms and 3 - 28% for lipophilic vitamin D and esters. Two solid phase extraction (SPE) based on the (i) "bind and elute strategy" and (ii) "removal strategy" using hydrophilic-lipophilic balanced SPE sorbent were optimized as a proceeding step for acetone extracts to increase the method selectivity. Finally, two optimized methods, combining solid-liquid extraction and individual SPE strategy, were examined in terms of sensitivity, recovery, matrix effect, accuracy, and precision. The limits of quantification were in the range of 1 - 10 ng/mL and 3 - 20 ng/mL analyzed by ultra-high performance supercritical fluid chromatography and ultra-high performance liquid chromatography hyphenated a with tandem mass spectrometer, respectively. The absolute recovery determined for the "bind and elute strategy" protocol was in the range of 3 - 24 %. Nevertheless, this method was free of matrix effects, which were determined to be in the 73 - 120 % range. On the contrary, the "removal strategy" approach provided higher recovery values for all compounds (47 - 123 %), but the results for nonpolar vitamin D and esters were strongly affected by signal suppression (matrix effects 3 - 51 %). Both methods fulfilled the criteria for accuracy and precision requested by the European Medicine Agency Guideline on Bioanalysis. "Removal strategy" SPE with decreased manual intervention and lower solvent consumption was finally applied to mouse liver tissue to determine vitamin D and its hydroxylated and esterified metabolites for the first time. The results, i.e., vitamin D esters detected in liver tissue, supported the notion that esters of vitamin D can be stored in lipophilic tissues to release vitamin D.


Assuntos
Espectrometria de Massas em Tandem , Vitamina D , Animais , Camundongos , Espectrometria de Massas em Tandem/métodos , Acetona , Cromatografia Líquida de Alta Pressão/métodos , Solventes , Vitaminas , Fígado , Heptanos , Extração em Fase Sólida/métodos
2.
Artigo em Inglês | MEDLINE | ID: mdl-38513431

RESUMO

Fat-soluble vitamin D is an essential bioactive compound important for human health. Insufficient vitamin D levels can result not only in bone disease but also in other disorders, such as cancer, metabolic disorders, and diseases related to poor immune function. The current methods commonly used for vitamin D analysis are often applied to determine the levels of the most abundant metabolite in plasma, i.e., 25-OH-D2/D3. These methods do not consider the presence of other hydroxylated and esterified metabolites, including isomers and epimers, which are typically found in low concentrations. In this study, we developed a fast and selective ultra-high performance supercritical fluid chromatography (UHPSFC) method using a 150 mm long 1-amino anthracene (1-AA) column and a mobile phase consisting of carbon dioxide and methanol/isopropanol (1/1, v/v) mixed with 8 % water. After thorough optimization of column temperature and back pressure, the separation of four vitamin D3 esters, vitamin D3 and D2, and eight mono- and di-hydroxylated metabolites, including three groups of isomers, was achieved in 10 min. Two ion sources, atmospheric pressure chemical ionization (APCI) and atmospheric pressure photoionization optimized within this study, were compared in tandem mass spectrometry (MS/MS) detection. No significant sensitivity differences were observed. Subsequently, the same 1-AA column chemistry was examined in ultra-high performance liquid chromatography (UHPLC) as the stationary phase that could hypothetically bring different selectivity in the separation of vitamin D and its metabolites. However, this hypothesis was rejected, and C18 was used as a stationary phase in the final optimized UHPLC-MS/MS method. Despite detailed optimization, the final 15 min UHPLC method was not able to separate di-hydroxylated isomers of vitamin D3, while it enabled better resolution of esterified forms compared to UHPSFC. Optimized methods provided similar repeatability of retention times and peak areas, with RSD < 2 % and 10 %, respectively. The lowest limits of quantification were in the range of 1.2 - 4.9 ng/mL for UHPSFC-APCI-MS/MS, while for UHPLC-APCI-MS/MS, they were typically in the range of 2.6 - 9.6 ng/mL. Based on the obtained results, the UHPSFC-APCI-MS/MS method was the most promising approach for fast, selective, and sensitive analysis that could be applied in the analysis of biological samples with emphasis on the separation of both hydroxylated and esterified metabolites, including isomeric forms.


Assuntos
Cromatografia com Fluido Supercrítico , Vitamina D , Humanos , Espectrometria de Massas em Tandem/métodos , Cromatografia Líquida de Alta Pressão/métodos , Cromatografia com Fluido Supercrítico/métodos , Vitaminas , Colecalciferol
3.
Anal Chem ; 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38300751

RESUMO

Complex analysis of plant extracts usually requires a combination of several analytical approaches. Therefore, in this study, we developed a holistic two-injection approach for plant extract analysis, which is carried out within one instrument without the need for any manual intervention during the analysis. Ultrahigh-performance supercritical fluid chromatography (UHPSFC) was employed for the analysis of 17 volatile terpenes on a porous graphitic carbon column within 7.5 min, followed by analysis on short diol column where flavonoids, phenolic acids, and terpenoic acids were analyzed within 15.5 min. A multimodal ionization source combining electrospray and atmospheric pressure chemical ionization (ESCi) was selected for mass spectrometry detection as a simultaneous ionization of both lipophilic and polar compounds was required. The quantitative aspects of the final UHPSFC-ESI/ESCi-MS/MS two-injection approach were determined, and it was applied to the analysis of Eucalyptus sp. extracts prepared by supercritical fluid extraction. Current methods reported in the literature typically require a labor-intensive combination of liquid and gas chromatography for the complex analysis of plant extracts. We present for the first time a new UHPSFC approach requiring only a single instrument that provides an alternative approach to the analysis of complex plant extracts.

4.
J Sep Sci ; 46(18): e2300431, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37568246

RESUMO

Within this review, we thoroughly explored supercritical fluid chromatography (SFC) columns used across > 3000 papers published from the first study carried out under SFC conditions in 1962 to the end of 2022. We focused on the open tubular capillary, packed capillary, and packed columns, their chemistries, dimensions, and trends in used stationary phases with correlation to their specific interactions, advantages, drawbacks, used instrumentation, and application field. Since the 1990s, packed columns with liquid chromatography and SFC-dedicated stationary phases for chiral and achiral separation are predominantly used. These stationary phases are based on silica support modified with a wide range of chemical moieties. Moreover, numerous unconventional stationary phases were evaluated, including porous graphitic carbon, titania, zirconia, alumina, liquid crystals, and ionic liquids. The applications of unconventional stationary phases are described in detail as they bring essential findings required for further development of the supercritical fluid chromatography technique.

5.
Anal Chim Acta ; 1251: 340966, 2023 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-36925276

RESUMO

A sample preparation method involving tandem implementation of protein precipitation and salting-out homogenous liquid-liquid extraction was developed for the determination of beta-blockers in serum. The entire procedure was automated using a computer-controlled syringe pump following the Lab-In-Syringe approach. It is based on the denaturation of serum proteins with acetonitrile followed by salt-induced phase separation upon which the proteins accumulate as a compact layer at the interphase of the solutions. The extract is then separated and diluted in-syringe before being submitted to online coupled UHPLC-MS/MS. A 1 mL glass syringe containing a small stir bar for solution mixing at up to 3000 rpm, was used to deal with sample volumes as small as 100 µL. A sample throughput of 7 h-1 was achieved by performing the chromatographic run and sample preparation procedure in parallel. Linear working ranges were obtained for all analytes between 5 and 100 ng mL-1, with LOD values ranging from 0.4 to 1.5 ng mL-1. Accuracy values in the range of 88.2-106% and high precision of <11% RSD suggest applicability for routine analysis that can be further improved using deuterated standards.


Assuntos
Seringas , Espectrometria de Massas em Tandem , Cromatografia Líquida de Alta Pressão/métodos , Extração Líquido-Líquido/métodos , Cloreto de Sódio
6.
Foods ; 12(4)2023 Feb 19.
Artigo em Inglês | MEDLINE | ID: mdl-36832968

RESUMO

New extraction protocols, gas-expanded liquid extraction (GXLE), and ultrasound extraction (UE) have been optimized with an emphasis on using green solvents and maximizing the extraction of 14 selected phenolic compounds, including flavonoid-based compounds and phenolic acids from dried apples. The design of the experiments' approach was applied to optimize the main extraction parameters. Fine tuning included optimization of the flow rate in GXLE and the extraction time for GXLE and UE. Optimized GXLE was carried out with CO2-ethanol-water (34/53.8/12.2; v/v/v) at a flow rate of 3 mL/min at a temperature of 75 °C and pressure of 120 bar for 30 min. UE with ethanol-water 26/74 (v/v) lasted for 10 min at 70 °C. Both methods differed in solvent consumption and sample throughput, while providing a comparable total phenolic content of 2442 µg/g with an RSD < 10% and 2226 µg/g with RSD < 6%, for GXLE and UE, respectively. Both methods were used in determining the phenolic compounds in five apple cultivars, 'Angold', 'Artiga', 'Golden Delicious', 'Meteor', and 'Topaz'. Phenolic profiles were plotted with chlorogenic acid, catechin, epicatechin, hirsutrin, phloridzin, and guaiaverin as the main components. Statistical evaluation, including pair t-test, Bland-Altman test, and linear regression did not reveal any differences between UE and GXLE results.

7.
Anal Chim Acta ; 1232: 340452, 2022 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-36257737

RESUMO

We developed a fast, selective, and sensitive method for the determination of various neutral and acidic phytocannabinoids with an emphasis on the separation of structurally related compounds. Optimized ultra-high performance supercritical fluid chromatography (UHPSFC) allowed the separation of 2 groups of structural isomers, including isomers of m/z 357: cannabidiolic and Δ9-tetrahydrocannabinolic acid, and isomers of m/z 315: cannabichromene, Δ9-tetrahydrocannabinol, Δ8-tetrahydrocannabinol, cannabicyclol, and cannabidiol only in mere 3.5 min followed by 1.5 min equlibration. The 2-ethylpyridine functionalized stationary phase and gradient elution using mobile phase comprising carbon dioxide and methanol: acetonitrile (25:75) + 5% water mixture were selected after the optimization. Tandem mass spectrometry (MS/MS) with electrospray ionization in positive and negative modes with methanol + 5% water as a make-up solvent provided adequate selectivity and sensitivity needed for analysis of phytocannabinoids in complex matrices. The limits of quantification were in the range 0.01-0.5 ng/mL for most of the monitored cannabinoids. The optimized UHPSFC-MS/MS method was then used for the determination of cannabinoids in various products, such as dietary supplements, nutraceuticals, and cosmetics. Solvent extraction methods were optimized for the cosmetic and nutraceutical products with the accuracy in the range 80.4-120.6% and precision 0.5-18.9%. To extract cannabinoids from the herbal infusion matrix, supercritical fluid extraction (SFE) and pressurized liquid extraction (PLE) methods were developed using environmentally friendly solvents water, ethanol, and carbon dioxide. The detailed optimization of extraction solvent composition, temperature, and pressure was carried out with the emphasis on avoiding the thermal degradation of cannabinoids. Optimized SFE and PLE methods were compared and applied to different herbal infusions to confirm declared cannabinoids content.


Assuntos
Canabidiol , Canabinoides , Cannabis , Cromatografia com Fluido Supercrítico , Espectrometria de Massas em Tandem/métodos , Cannabis/química , Dronabinol/análise , Canabidiol/análise , Metanol/química , Dióxido de Carbono/química , Canabinoides/análise , Cromatografia com Fluido Supercrítico/métodos , Solventes/análise , Água , Etanol , Acetonitrilas , Cromatografia Líquida de Alta Pressão/métodos
8.
Plant Methods ; 18(1): 87, 2022 Jun 23.
Artigo em Inglês | MEDLINE | ID: mdl-35739596

RESUMO

BACKGROUND: Quercetin is one of the most important bioflavonoids having positive effects on the biological processes and human health. Typically, it is extracted from plant matrices using conventional methods such as maceration, sonication, infusion, and Soxhlet extraction with high solvent consumption. Our study aimed to optimize the environmentally friendly carbon dioxide-based method for the extraction of quercetin from quince fruit with an emphasis on extraction yield, repeatability, and short extraction time. RESULTS: A two-step design of experiments was used for the optimization of the key parameters affecting physicochemical properties, including CO2/co-solvent ratio, co-solvent type, temperature, and pressure. Finally, gas expanded liquid combining CO2/ethanol/H2O in a ratio of 10/81/9 (v/v/v) provided the best extraction yield. Extraction temperature 66 °C and pressure 22.3 MPa were the most suitable conditions after careful optimization, although both parameters did not significantly affect the process. It was confirmed by experiments in various pressure and temperature conditions and statistical comparison of obtained data. The optimized extraction procedure at a flow rate of 3 mL/min took 30 min. The repeatability of the extraction method exhibited an RSD of 20.8%. CONCLUSIONS: The optimized procedure enabled very fast extraction in 30 min using environmentally friendly solvents and it was successfully applied to 16 different plant samples, including 14 bulbs and 2 fruits from South Africa. The quercetin content in extracts was quantified using ultra-high performance liquid chromatography (UHPLC) with tandem mass spectrometry. UHPLC hyphenated with high-resolution mass spectrometry was used to confirm chemical identity of quercetin in the analyzed samples. We quantified quercetin in 11 samples of all 16 tested plants. The quercetin was found in Agapanthus praecox from the Amaryllidaceae family and its presence in this specie was reported for the first time.

9.
Crit Rev Clin Lab Sci ; 59(8): 517-554, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35575431

RESUMO

Vitamin D has a well-known role in the calcium homeostasis associated with the maintenance of healthy bones. It increases the efficiency of the intestinal absorption of dietary calcium, reduces calcium losses in urine, and mobilizes calcium stored in the skeleton. However, vitamin D receptors are present ubiquitously in the human body and indeed, vitamin D has a plethora of non-calcemic functions. In contrast to most vitamins, sufficient vitamin D can be synthesized in human skin. However, its production can be markedly decreased due to factors such as clothing, sunscreens, intentional avoidance of the direct sunlight, or the high latitude of the residence. Indeed, more than one billion people worldwide are vitamin D deficient, and the deficiency is frequently undiagnosed. The chronic deficiency is not only associated with rickets/osteomalacia/osteoporosis but it is also linked to a higher risk of hypertension, type 1 diabetes, multiple sclerosis, or cancer. Supplementation of vitamin D may be hence beneficial, but the intake of vitamin D should be under the supervision of health professionals because overdosing leads to intoxication with severe health consequences. For monitoring vitamin D, several analytical methods are employed, and their advantages and disadvantages are discussed in detail in this review.


Assuntos
Raquitismo , Deficiência de Vitamina D , Humanos , Vitamina D/metabolismo , Vitamina D/uso terapêutico , Cálcio , Deficiência de Vitamina D/complicações , Deficiência de Vitamina D/tratamento farmacológico , Vitaminas , Raquitismo/complicações , Raquitismo/tratamento farmacológico , Cálcio da Dieta
10.
Anal Chem ; 94(7): 3065-3073, 2022 02 22.
Artigo em Inglês | MEDLINE | ID: mdl-35138814

RESUMO

In this study, an analytical method has been developed that, for the first time, allows simultaneous determination of vitamin D2 and vitamin D3 along with their hydroxylated and esterified forms. A group of 12 vitamin D analogues including vitamin D2 and vitamin D3, seven hydroxylated metabolites, and three ester forms were separated in a single 8.0 min run using ultrahigh-performance supercritical fluid chromatography coupled with triple quadrupole tandem mass spectrometry. Electrospray ionization and atmospheric pressure chemical ionization were investigated as ion sources, of which the latter showed a higher ionization efficiency. Chromatographic conditions were thoroughly evaluated by a step-by-step method, whereas an experimental design was applied for the optimization of the ionization parameters. Calibration and repeatability studies were carried out to validate the instrumental methodology showing determination coefficients higher than 0.9992 and good intra- and interday precision with relative standard deviations for areas and retention times lower than 10 and 2.1%, respectively, for all target analytes. Limits of quantification were below 3.03 µg/L for all compounds. The methodology was then validated and applied for the evaluation of human plasma samples in order to demonstrate its applicability to the analysis of vitamin D analogues in biological samples. Samples of five individuals were analyzed. Results show that linoleate-D3, vitamin D2, vitamin D3, 25-hydroxyvitamin D2, 24,25-dihydroxyvitamin D3, and 1,25-dihydroxyvitamin D3 could be detected in most samples, while the two latter also were quantified in all analyzed samples.


Assuntos
Cromatografia com Fluido Supercrítico , Espectrometria de Massas em Tandem , Calcifediol , Humanos , Espectrometria de Massas em Tandem/métodos , Vitamina D , Vitaminas
11.
Biomed Pharmacother ; 129: 110506, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32768979

RESUMO

Special attention is required when pharmacological treatment is indicated for a pregnant woman. P-glycoprotein (MDR1) is a well-known transporter localized in the maternal blood-facing apical membrane of placental syncytiotrophoblast and is considered to play an important role in protecting the developing fetus. Maraviroc, a MDR1 substrate that is registered for treatment of HIV infection, shows a low toxicity profile, suggesting favorable tolerability also if administered to pregnant women. Nevertheless, there is only poor understanding to date regarding the extent to which it permeates across the placental barrier and what are the transport mechanisms involved. Endeavoring to clarify the passage of maraviroc across placenta, we used in this study the method of closed-circuit perfusion of maraviroc across human placental cotyledon. The data obtained confirmed slight involvement of MDR1, but they also suggest possible interaction with other transport system(s) working in the opposite direction from that of MDR1. Complementary in vitro studies, including cellular experiments on choriocarcinoma BeWo cells as well as transporter-overexpressing MDCKII and A431 cell lines and accumulation in placental fresh villous fragments, revealed maraviroc transport by MRP1, OATP1A2, and OATP1B3 transporters. Based on mRNA expression data in the placental tissue, isolated trophoblasts, and fetal endothelial cells, especially MRP1 and OATP1A2 seem to play a crucial role in cooperatively driving maraviroc into placental tissue. By the example of maraviroc, we show here the important interplay of transporters in placental drug handling and its possibility to overcome the MDR1-mediated efflux.


Assuntos
Fármacos Anti-HIV/metabolismo , Maraviroc/metabolismo , Proteínas Associadas à Resistência a Múltiplos Medicamentos/metabolismo , Transportadores de Ânions Orgânicos/metabolismo , Placenta/metabolismo , Membro 1B3 da Família de Transportadores de Ânion Orgânico Carreador de Soluto/metabolismo , Subfamília B de Transportador de Cassetes de Ligação de ATP/antagonistas & inibidores , Subfamília B de Transportador de Cassetes de Ligação de ATP/genética , Subfamília B de Transportador de Cassetes de Ligação de ATP/metabolismo , Acridinas/farmacologia , Animais , Fármacos Anti-HIV/sangue , Fármacos Anti-HIV/farmacologia , Linhagem Celular Tumoral , Cães , Interações Medicamentosas , Feminino , Regulação da Expressão Gênica , Humanos , Células Madin Darby de Rim Canino , Maraviroc/sangue , Proteínas Associadas à Resistência a Múltiplos Medicamentos/genética , Transportadores de Ânions Orgânicos/antagonistas & inibidores , Transportadores de Ânions Orgânicos/genética , Perfusão , Placenta/efeitos dos fármacos , Circulação Placentária , Gravidez , Ritonavir/farmacologia , Membro 1B3 da Família de Transportadores de Ânion Orgânico Carreador de Soluto/antagonistas & inibidores , Membro 1B3 da Família de Transportadores de Ânion Orgânico Carreador de Soluto/genética , Tetra-Hidroisoquinolinas/farmacologia
12.
Anal Bioanal Chem ; 412(24): 6529-6541, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32468279

RESUMO

The new ultra-high performance liquid chromatography method with tandem mass spectrometry detection (UHPLC-MS/MS) has been optimized to allow fast, selective, and high-throughput analysis of two Candida albicans quorum sensing molecules (QSM), farnesol and tyrosol. The problem of the presence of the interference in the samples and system was successfully solved by careful optimization of chromatographic conditions. Charged hybrid stationary phase modified with pentafluorophenyl group and optimized gradient elution provided adequate separation selectivity and peak shapes. The impurity was identified as dibutyl phthalate and had the same m/z ions as farnesol leading to an important interference on selected reaction monitoring channel. Two different types of biological matrices originating from vaginal fluid, supernatant and sediment, were analysed. Micro-solid phase extraction in pipette tips was optimized for the selective isolation of QSM from the supernatant. The insufficient retention of farnesol on the extraction sorbent was improved when 1% of organic solvent was added prior to extraction, while the retention of tyrosol was only possible when using combined C8 and polymer sorbent type. Strong retention of farnesol had to be solved by increasing elution solvent strength and volume up to 600 µL. However, this approach did not allow the pretreatment of sediment samples due to the sorbent clogging. Therefore, our previously developed protein precipitation method was modified and validated to analyse the sediments. New developed UHPLC-MS/MS method provided suitable accuracy and precision for the determination of QSM in vaginal fluid while using only 50 µL sample volume and two different sample preparation methods.


Assuntos
Farneseno Álcool/análise , Álcool Feniletílico/análogos & derivados , Espectrometria de Massas em Tandem/métodos , Vagina/microbiologia , Adulto , Candida albicans/isolamento & purificação , Cromatografia Líquida de Alta Pressão/métodos , Feminino , Humanos , Limite de Detecção , Pessoa de Meia-Idade , Álcool Feniletílico/análise , Vagina/química , Adulto Jovem
13.
Vascul Pharmacol ; 111: 36-43, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30118763

RESUMO

SCOPE: The flavonoid quercetin reduces arterial blood pressure in animals and humans but the mechanisms remains elusive. The aim of this study was to test the activity of flavonoid microbial metabolites, which can participate on the final vasorelaxant effect. METHODS AND RESULTS: Both ex vivo (isolated rat thoracic aorta and mesenteric artery) and in vivo (normotensive and spontaneously hypertensive rats) approaches were used in this study. 4-methylcatechol and 3,4-dihydroxyphenylacetic acid (DHPA) had greater vasorelaxant effects on mesenteric artery than 3-(3-hydroxyphenyl)propionic acid, the previously reported metabolite with vasorelaxant effect. In vivo testing confirmed their blood pressure decreasing effect given both as bolus and slow infusion. Their mechanism at molecular level was different. CONCLUSIONS: This study is the first to show that flavonoid metabolites DHPA and 4-methylcatechol decrease arterial blood pressure and hence a mixture of microbial metabolites formed in the gastrointestinal tract may be responsible for or contribute to the effect of orally ingested quercetin.


Assuntos
Ácido 3,4-Di-Hidroxifenilacético/farmacologia , Anti-Hipertensivos/farmacologia , Aorta Torácica/efeitos dos fármacos , Pressão Arterial/efeitos dos fármacos , Catecóis/farmacologia , Hipertensão/tratamento farmacológico , Artérias Mesentéricas/efeitos dos fármacos , Vasodilatação/efeitos dos fármacos , Vasodilatadores/farmacologia , Animais , Modelos Animais de Doenças , Hipertensão/fisiopatologia , Técnicas In Vitro , Masculino , Ratos Endogâmicos SHR , Ratos Wistar
14.
Talanta ; 185: 71-79, 2018 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-29759252

RESUMO

Fast, selective, and sensitive ultra-high performance liquid chromatography method with tandem mass spectrometry detection for the determination of quercetin and its metabolites with various physico-chemical properties such as molecular weight, lipophilicity, and acid-base properties has been developed. These compounds included small hydrophilic phenolic acids and more lipophilic metabolites with preserved flavonoid structure in small amount of rat plasma. The developed method enables selective separation of phenolic acids and a pair of isomers tamarixetin and isorhamnetin with satisfactory peak shapes and a high sensitivity using mass spectrometry detection. In addition, two sample preparation procedures including protein precipitation and microextraction in packed sorbent (MEPS) were optimized. The sample acidification included in protein precipitation as well as optimizing of MEPS sorbents and elution solvents improved isolation of quercetin and related compounds from rat plasma. Finally, both methods developed for sample preparation were fully validated to demonstrate sufficient accuracy and precision and acceptable matrix effects. Both sample preparation approaches combined with mass spectrometry-based quantification allowed the simultaneous determination of quercetin and its metabolites from a small amount of biological samples of only 50 µL. Due to the fast and non-selective parallel sample preparation, the protein precipitation was eventually applied to plasma samples derived from pharmacokinetic studies.


Assuntos
Quercetina/sangue , Animais , Cromatografia Líquida de Alta Pressão , Quercetina/metabolismo , Ratos , Ratos Wistar , Espectrometria de Massas em Tandem
15.
J Exp Bot ; 69(10): 2569-2579, 2018 04 27.
Artigo em Inglês | MEDLINE | ID: mdl-29514302

RESUMO

Auxin (indole-3-acetic acid, IAA) plays fundamental roles as a signalling molecule during numerous plant growth and development processes. The formation of local auxin gradients and auxin maxima/minima, which is very important for these processes, is regulated by auxin metabolism (biosynthesis, degradation, and conjugation) as well as transport. When studying auxin metabolism pathways it is crucial to combine data obtained from genetic investigations with the identification and quantification of individual metabolites. Thus, to facilitate efforts to elucidate auxin metabolism and its roles in plants, we have developed a high-throughput method for simultaneously quantifying IAA and its key metabolites in minute samples (<10 mg FW) of Arabidopsis thaliana tissues by in-tip micro solid-phase extraction and fast LC-tandem MS. As a proof of concept, we applied the method to a collection of Arabidopsis mutant lines and identified lines with altered IAA metabolite profiles using multivariate data analysis. Finally, we explored the correlation between IAA metabolite profiles and IAA-related phenotypes. The developed rapid analysis of large numbers of samples (>100 samples d-1) is a valuable tool to screen for novel regulators of auxin metabolism and homeostasis among large collections of genotypes.


Assuntos
Arabidopsis/genética , Sequenciamento de Nucleotídeos em Larga Escala/métodos , Ácidos Indolacéticos/metabolismo , Mutação , Proteínas de Plantas/análise , Arabidopsis/metabolismo , Cromatografia Líquida , Análise Multivariada , Extração em Fase Sólida , Espectrometria de Massas em Tandem
16.
Int J Pharm ; 541(1-2): 224-233, 2018 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-29474897

RESUMO

Potential positive effects of flavonol quercetin on humans were suggested by many studies. However, it is not clear if these effects are mediated by quercetin or its metabolites. The in vivo confirmation of quercetin effects is largely hindered by its low water solubility and thus impossibility to test directly its impact. Therefore, a solid dispersion of quercetin with polyvinylpyrrolidone (PVP) was developed to prepare an injectable formulation of water-soluble quercetin. The optimized formulation provided a 20,000-fold increase in quercetin solubility. This formulation was tested on conventional and spontaneously hypertensive rats; it lowered their blood pressure in both short- and long-term basis. Pharmacokinetic data are also provided. This study reports for the first time an injectable water-soluble formulation of quercetin suitable for confirmation of its vascular effect in vivo.


Assuntos
Anti-Hipertensivos/farmacologia , Pressão Sanguínea/efeitos dos fármacos , Composição de Medicamentos/métodos , Povidona/química , Quercetina/farmacologia , Animais , Anti-Hipertensivos/química , Anti-Hipertensivos/uso terapêutico , Disponibilidade Biológica , Química Farmacêutica , Modelos Animais de Doenças , Humanos , Hipertensão/tratamento farmacológico , Injeções Intravenosas , Masculino , Tamanho da Partícula , Quercetina/química , Quercetina/uso terapêutico , Ratos , Ratos Endogâmicos SHR , Ratos Wistar , Solubilidade , Água/química
17.
Bioanalysis ; 9(11): 887-901, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28617093

RESUMO

AIM: Micro-SPE in pipette tips (µ-SPE-PT) with particle sorbent has never been used in small-molecule drug analysis. Methodology & results: µ-SPE-PT was used for the extraction of statins from biological materials followed by UHPLC-MS/MS. The commercial and homemade µ-SPE-PT tips filled with particle sorbent were compared. While the homemade tips enabled direct serum sample loading into the sorbent, protein precipitation (PP) had to be implemented before µ-SPE-PT procedure using commercial tips. Three µ-SPE-PT methods were developed and validated: method A: µ-SPE-PT with homemade tips; method B: PP + µ-SPE-PT with homemade tips; and method C: PP + µ-SPE-PT with commercial tips. Method A enabled a simple high-throughput approach (48 samples in 90 min) compared with methods B and C that required three-times longer time. However, PP increased the recoveries of protein-bound analytes and extracts purity in methods B and C. The matrix effects without internal standards correction for method C were significantly higher than those for the methods A and B. CONCLUSION: Compared with commercial tips, homemade tips filled with particles were found to be more suitable for drug analysis. Commercial tips tested in this study were found challenging but the conditions under which they could be applicable were also defined.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Preparações Farmacêuticas/sangue , Microextração em Fase Sólida/métodos , Espectrometria de Massas em Tandem/métodos , Desenho de Equipamento , Humanos , Limite de Detecção , Microextração em Fase Sólida/instrumentação
18.
Redox Rep ; 22(2): 78-90, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27077454

RESUMO

OBJECTIVES: Rutin, quercetin-3-O-rutinoside, a natural flavonol glycoside, has shown various in vitro benefits with potential use treating human diseases, especially cardiovascular system disorders. Antioxidant properties are assumed to underlie the majority of these benefits. Yet rutin pro-oxidant properties have been reported as well. Our research group has recently shown aggravating effects on isoprenaline (ISO)-induced cardiotoxicity in Wistar:Han rats after 24 hours. METHODS: This study was designed to examine in more detail the reasons for the negative effects of rutin (11.5 and 46 mg/kg, i.v.) after administration of ISO (100 mg/kg, s.c.) in rats within 2 hours of continuous experiment and in the H9c2 cardiomyoblast-derived cell line. RESULTS: Like our previous findings, rutin did not (11.5 or 46 mg/kg, i.v.) reduce the ISO-induced mortality within 2 hours although the lower dose significantly reduced cardiac troponin T (cTnT) and partly improved the histological findings. In contrast, the higher dose increased the mortality in comparison with solvent (1.26% w/v sodium bicarbonate). This was not caused by any specific haemodynamic disturbances. It appears to be associated with oxidative stress as rutin enhanced intracellular reactive oxygen species formation in vitro and had the tendency to increase it in vivo. CONCLUSIONS: Rutin, likely due to its pro-oxidative effects, can exacerbate catecholamine cardiotoxicity depending on the dose used.


Assuntos
Cardiotoxicidade/etiologia , Isoproterenol/efeitos adversos , Rutina/efeitos adversos , Animais , Cardiotoxicidade/mortalidade , Linhagem Celular , Dinoprosta/análogos & derivados , Dinoprosta/sangue , Relação Dose-Resposta a Droga , Eletrocardiografia , Glutationa/sangue , Coração/efeitos dos fármacos , Injeções Intravenosas , Estimativa de Kaplan-Meier , Masculino , Miocárdio/patologia , Ratos Wistar , Espécies Reativas de Oxigênio/metabolismo , Rutina/administração & dosagem , Rutina/farmacocinética
19.
Artigo em Inglês | MEDLINE | ID: mdl-27650942

RESUMO

The new microextraction technique named parallel artificial liquid membrane extraction (PALME) was introduced as an alternative approach to liquid-liquid extraction of charged analytes from aqueous samples. The concept is based on extraction of analytes across a supported liquid membrane sustained in the pores of a thin polymeric membrane, a well-known extraction principle also used in hollow fiber liquid-phase microextraction (HF-LPME). However, the new PALME technique offers a more user-friendly setup in which the supported liquid membrane is incorporated in a 96 well plate system. Thus, high-throughput is achievable, in addition to the green chemistry offered by using PALME. The consumption of organic solvent is minimized to 3-5µL per sample. With a sample volume of 250µL and acceptor solution volume of 50µL, a maximal enrichment factor of five is achievable. Based on these parameters, a new method for extraction of polar basic drugs was developed in the present work. The basic drugs hydralazine, ephedrine, metaraminol, salbutamol, and cimetidine were used as model analytes, and were extracted from alkalized human plasma into an aqueous solution via the supported liquid membrane. The extraction was promoted by a carrier dissolved in the membrane, creating a temporary ion-pair complex between the hydrophilic drug and the carrier. As the model analytes were extracted directly into an aqueous solution, there was no need for evaporation of the extract before injection into LC-MS. Hence, the sample preparation is performed in one step. With optimized conditions, the extraction recoveries were in the range 50-89% from human plasma after 45min extraction. The data from the method evaluation were satisfactory and in line with current guidelines, and revealed an extraction method with substantial potential for high throughput bioanalysis of polar basic drugs.


Assuntos
Cromatografia Líquida/métodos , Extração Líquido-Líquido/métodos , Espectrometria de Massas/métodos , Membranas Artificiais , Preparações Farmacêuticas/sangue , Preparações Farmacêuticas/isolamento & purificação , Humanos , Limite de Detecção , Modelos Lineares , Preparações Farmacêuticas/química , Reprodutibilidade dos Testes
20.
Anal Chim Acta ; 934: 252-65, 2016 Aug 31.
Artigo em Inglês | MEDLINE | ID: mdl-27506367

RESUMO

The goal of this study was to develop an effective supercritical fluid chromatography method using single quadrupole MS for analysis of all isomeric forms of vitamin E. Finally, two fast and effective methods, the high resolution one and the high speed one, for the determination of 8 vitamin E isomers in human serum were developed. Rapid high-throughput liquid-liquid extraction was selected as a sample preparation step. Sample pretreatment of 100 µL human serum was consisted of protein precipitation with 200 µL ethanol and liquid-liquid extraction by 400 µL hexane/dichloromethane (80/20, v/v). The separation was performed on BEH 2-EP (3.0 × 100 mm, 1.7 µm) stationary phase, using isocratic elution with carbon dioxide and 10 mM ammonium formate in methanol in the ratio 98:2 for high resolution method with run time 4.5 min and in the ratio 95:5 for high speed method, where the run time was 2.5 min. The method development included optimization of key parameters: the choice of the suitable stationary phase and the composition of mobile phase, where an influence of various modifiers, their ratio and additives were tested, and optimization of fine tunning parameters including BPR pressure, flow-rate and column temperature. Quantification of all isomeric forms was performed using SIM (single ion monitoring) experiments in ESI positive ion mode. Both high speed and high resolution chromatographic methods were validated in terms of precision, accuracy, range, linearity, LOD, LOQ and matrix effects using the same LLE procedure. The high resolution method provided more sensitive results (LOD: 0.017-0.083 µg mL(-1)) and better linearity (r(2) > 0.9930) than the high speed one (LOD: 0.083-0.25 µg mL(-1), r(2) > 0.9877) at the cost of double time of analysis.


Assuntos
Cromatografia com Fluido Supercrítico , Tocoferóis/sangue , Tocotrienóis/sangue , Humanos , Extração Líquido-Líquido , Espectrometria de Massas , Conformação Molecular , Tocoferóis/química , Tocotrienóis/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA